PRODUCT DATASHEET

PRODUCT SPEC SHEET


SCADA SOLUTIONS
MOTOTRBO™
DEP™450- PORTABLE
ACE1000 RADIOS

SCADA SOLUTIONS - RELIABLE COMMUNICATIONS OVER LARGE AREAS

ACE1000 REMOTE
USER BENEFITS
• E asy to Install and
Manage

TERMINAL UNIT
• Interoperability with
current systems
• Better processing power
• L arge FLASH & RAM
Whether there is a leaking pipe or a damaged power grid breaker miles away from your Memory
control center, you need to know about it as soon as possible. The sooner you get the • A
 TEX Regulatory
information, the faster you can fix the problem and avoid negative consequences. Compliance
• Power-saving features
You need technology that works seamlessly with its software and connects to your
equipment to ensure reliable, well-timed communications over a large area. You can’t
be in multiple places at once, but with a reliable SCADA solution you can monitor your
system as if you were.
The versatile and powerful ACE1000 will deliver the timely communications you need,
without having to completely replace your current system. In a new, compact package,
the ACE1000 is the Remote Terminal Unit (RTU) that will facilitate higher reliability and
interoperability at a lower cost.
PRODUCT DATASHEET
PRODUCT SPEC SHEET
MOTOTRBO
SCADA DEP™450ACE1000
SOLUTIONS-

PORTABLE RADIOS

COMMUNICATE EFFORTLESSLY SEAMLESS CONFIGURATION KEY FEATURES


Complex communication links from your central to remote The ACE1000 is easy to install and has the processing power
sites are what make up a reliable and secure SCADA to function in demanding environments and complicated • M
 otorola Radio Support
system. The ACE1000’s unique connection capabilities allow networks. Its user-friendly configuration tools allow you to (Digital Trunked ASTRO,
your system to communicate using a variety of outputs set up your whole system, rather than each unit individually, Digital MOTOTRBO,
(slow dial-up, medium speed RF, and high speed wireless), so you can maintain it yourself. Easy-to-use applications such TETRA)
at no extra cost. as the new menu-driven GUI and the “Easy Programming
Tool” reduce the amount of time and money needed for • Easy-Programming Tool
Designed for a wireless environment, the ACE1000 assures training, so your employees can get to work sooner. Your site (via WEB Browser)
reliable communications over RF, LAN/WAN networks, so can be supported remotely, reducing the amount of site visits • RTC Back-up Battery
you can be sure your data is being transferred securely. The you have to make.
ACE1000 allows RTU-central and RTU-RTU communications, • 2 56 MB of FLASH
along with advanced networking abilities, which can The ACE1000’s programming tools allow for easy Memory
be used to pass messages between RTUs in the system configuration, so your system can be adapted to demanding
• IECEx/ ATEX - EXnA IIC
so you don’t have to purchase additional repeaters or applications or stand alone. Your current platform can be
expensive antennas. Its communication flexibility gives you leveraged to provide the benefits of both standardization T4 (Cat 3/Zone 2)*
the freedom to customize your system that’s easy on your and interoperability without starting from scratch. Whether • 2 56 MB of RAM
budget. you need to collect and transmit information from existing Memory
sensors or IEDs, the ACE1000 is perfect for the job.
INTELLIGENT PERFORMANCE • 9 -30 VDC Input Voltage
Complicated control processes can be time consuming RUGGED AND READY FOR THE FIELD Range
and difficult to keep track of. The ACE1000 allows you to Not only will your transferred data be safe and secure, but
• Sleep/Low-power Mode
automate processes such as multiple high speed control your equipment will too. The ACE1000 RTU is designed to
loops, event capture, and data storage, so you don’t need to withstand harsh conditions, unlike the average PLC, which • 3 rd Party Modem
spend time doing it yourself. The ACE1000 even offers a low is built for the factory floor. Temperature, altitude, and Support
power and sleep mode option for when you’re operating on humidity are no match for the ACE1000, which meets rugged
solar power. Process automation improves efficiency and specifications. Whether it’s installed at an offshore drilling *w/o radio, in ATEX approved
plant safety and you can be sure the important tasks are platform or an Arctic power station, the environment won’t enclosure
being completed at the right time. This will free up your affect the performance of your system.
employees to do other tasks and as a result, streamline your
facility’s routine. OPTIONAL
FEATURES
• Din Wall|
Mounting Bar

ACE1000 Remote Terminal Unit without cover ACE1000 Remote Terminal Unit with covers

PAGE 2
PRODUCT DATASHEET
PRODUCT SPEC SHEET
SCADA SOLUTIONS
MOTOTRBO ™
DEP™450- ACE1000
PORTABLE RADIOS

GENERAL SPECIFICATIONS CPU


Operating Temperature -40 º C to + 70 º C (excluding radios) Processor Sitara CPU (Cortex-A8)
Storage Temperature -55 ºC to + 85 ºC (excluding radios) Clock 300 MHz
Operating Humidity 5% to 95% RH @ 50 ºC OS Linux
Operating Altitude -400 meters to +4000 meters Memory:
Dimensions 2.95 in. (w) x 6.3 in. (h) x 4.4 in. (d) Flash 256 MB, 32 MB for User
RAM 256 MB, 16 MB for User
Weight 450 grams (without expansions)
Wall Mount Option Yes (using DIN rail) RTC YES

Construction Modular Ports:

Power Consumption: RS232/RS485 Up to 1 port on CPU board (shared with RS485)


(<115.2Kbps) Non-Isolated
Typical Runtime ~170mA at 12v
RS232 Only 2 ports on plug-in board (<115.2Kbps) Isolated
Power Saving Mode 65mA at 12v Ethernet 1 port on CPU board 10/100MB

Sleep Mode ~5.5mA at 12v


POWER MANAGEMENT
RTC Back-up Battery:
Modes Disabled
Type Coin Rechargeable Battery (30 days)
Run Mode
Temperature - 40 ºC to + 70 ºC
Idle Sleep Mode
AUX Power Connector:
Low Power Sleep Mode
1 AUX Power Output Port 5v, 7.5v, 9.5v, 12v, V-IN (on plug-in) V-AUX <>
V-IN (CPU is off)

SDIO Card Up to 32 GB Wake-Up Triggers 3 Assigned DIs (CPU Board)


Manual Push-Button
UART Yes
Real-Time Clock
USB HOST Yes
C App
USB OTG Yes
Voltage Management Power up occurs if the voltage is in range,
USB Device Shared with USB OTG
or else a safe power down is performed
LAN Port (10/100Mbps) Yes automatically when voltage is too low. The unit
returns to its previous mode (run or idle sleep)
INPUTS/OUTPUTS (I/OS) when input power returns to predefined value.
I/Os: Power Voltage Reduced/ Radio/Auxilary Power Supply
CPU I/Os 3DI + 1DO Disabled¹ External I/Os
Two I/O Expansion Types 12DI + 8AI (isolated) Piggyback (All Components, or each serial port)
8DO + 2AO (isolated)
Serial Main Board Ports
Performances: USB HOST
DI Fast Counter 2Khz For All Inputs USB OTG
DI Time Tagging No Wire LAN
DI Event Capture ~ 100 msec
Wireless LAN
DO Control ~ 100 msec (w/out relay delay)

¹ This is statically configured (not via C App) and cannot be changed without a reboot to the LTR

PAGE 3
PRODUCT SPECSHEET
PRODUCT SPEC SHEET
MOTOTRBO
SCADA DEP™450- ACE1000
SOLUTIONS

PORTABLE RADIOS

SOFTWARE LED INDICATIONS


SW Tool: LEDS:
Mixed System Configuration - STS Tools Main CPU 4 General Function LEDs
SW Download - Web Interface Input/Output 4 General Function LEDs + 24 I/O LEDs
Diag/ErrorLogger/Partial Field View CPU Power (physical indication)
HW test - Yes ERR (physical indication, detailed error can be
LTR Only System Configuration/Monitoring - Web Interface seen in error logger)
HW Test- Yes LOAD (UI Indication)

MDLC Networking: CONF (UI Indication)

Networking Only in Mixed Systems APPL (UI Indication)

Direct Link Yes MON (UI Indication)

Central to RTU Yes- Built in Application RST Process (Indication on the PWR Lead)

RTU Burst Reporting Yes- Built in Application Ports Tx/Rx on main RS232 (dedicated physical LED)
RTU - RTU Communication Mixed System - Yes Tx/Rx on Piggyback RS232 (UI Indication)
LTR Only System- Via C Application Main I/Os Main DIs (represent on one of the 4 main board
MDLC Store and Forward Mixed System - Yes LEDS)

LTR Only System - No Main DO (represent on one of the 4 main board


LEDS)
Broadcast Sending (RTU-RTU) Mixed System - Yes
Expansion I/Os Modules DI
LTR Only System - Via C Application
DO
Failsafe Mechanism Yes
Input Card: 12 DI/8AI
Error Logger Yes
Output Card: 8 DO/2AO
HW Test Local (via CLI), not remote AI: Range/Out of Range, Current/Voltage (UI
HW Diag and Calibration 1) Digital Input Test Loop Indication, Automatic)

2) CPU Battery Level Calibrated (UI Indication)

3) Enhanced Power Management Test AO: On/Off (physical Indication), Current/Voltage


(UI, Manual Calibration)
User Programming 1) Rule-based easy programming
LEDs Tests Yes
2) C + Linux Functionality
CPU Fail Indication there is a fault on the fault LED
3) IEC61131-3 with External Communication
Interface INFRASTRUCTURES
MDLC ² via Ethernet Yes
Security MDLC password, Authentication Login, Firewall, MDLC via Terminal Server (SLIP) Yes
HTTPS, SFTP, SSH
MDLC over ASTRO [Link] (IV&D) Yes
Protocols MDLC, MODBUS over RS232/RS485/IP
MDLC over Null Modem Yes
Time Synchronization MDLC Time Sync (20 mS resolution with
MDLC over GPRS Yes
password)
MDLC over Standard (line) Yes
Set Date/Time Yes (with Time Zone and Daylight-Savings) Modem
Table Monitoring Utility Mixed System - No MDLC over Digital MOTOTRBO Yes
LTR Only System - Yes MDLC over IP Site Paging Yes
MDLC over IP Yes
Network Configuration Utility No
Services DNS - Yes
DHCP - Yes - Slave

² Motorola Data Link Communication (MDLC)

MOTOROLA, MOTO, MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings, LLC and are
used under license. All other trademarks are the property of their respective owners. © 2014 Motorola Solutions, Inc. All rights reserved. LDC R3-11-2038B

You might also like