PRODUCT APPROVAL SUPPORTING CALCULATIONS
Premium Atlantic Vinyl Impact Horizontal Slider
REPORT TO:
JELD-WED WINDOWS & DOORS
3737 LAKEPORT BLVD
KLAMATH FALLS, OREGON
REPORT NUMBER: NCTL-110-22068-1
REPORT DATE: 04/08/19
_____________________
Joseph A. Reed, PE
FL PE 58920
2019.05.15 07:55:46 -04'00'
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 1 of 10
Scope
National Certified Testing Laboratories was contracted by Jeld-Wen Windows & Doors to
evaluate alternate installation methods for their Premium Atlantic Vinyl Impact Horizontal
Sliding windows. The evaluation is based on physical testing and product certifications.
Reference standards utilized in this project include:
Florida Building Code, Building. International Code Council.
ANSI/AWC National Design Specification (NDS) for Wood Construction. American
Wood Council.
AISI S100 North American Specification for the Design of Cold-Formed Steel
Structural Members. American Iron and Steel Institute.
ICC-ES Report ESR-1976 ITW Buildex TEKS Self-Drilling Fasteners. ICC Evaluation
Service.
NOA 16-1222.06 Tapcon Concrete and Masonry Anchors with Advanced
Threadform Technology. Miami-Dade County Product Control Section.
The anchorage analyses presented herein do not address the water resistance, water
penetration or air infiltration performance of the installation method or the installed
product. In addition, the analyses rely on the assumption that the building substrate
is capable of withstanding incurred loads.
Certification of Independence
In accordance with Rule 61G20-3 Florida Administrative Code, National Certified Testing
Laboratories hereby certifies the following:
National Certified Testing Laboratories does not have, nor does it intend to acquire
or will it acquire, a financial interest in any company manufacturing or distributing
products tested or labeled by the agency.
National Certified Testing Laboratories is not owned, operated or controlled by any
company manufacturing or distributing products it tests or labels.
Joseph A. Reed, P.E. does not have nor will acquire, a financial interest in any
company manufacturing or distributing products for which the reports are being
issued.
Joseph A. Reed, P.E does not have, nor will acquire, a financial interest in any
other entity involved in the approval process of the product.
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 2 of 10
Analyses
Summary of Test Results
The following table summarizes the various Premium Atlantic Vinyl Impact Horizontal
Sliding Window products and their corresponding performance levels which have been
established by testing or product certification.
Table 1 Summary of Test Results
Test Report Product Size
Series/Model Number Certification (W x H) Performance
Premium Atlantic Vinyl NCTL 210-4010-01 +50/-55 psf
NI013719 111" x 54"
(XOX) (Rev. -, 04/19/17) Large Missile
Testing documented in Table 1 was conducted by the National Certified Testing
Laboratories laboratory in Orlando, Florida (Florida Department of Business &
Professional Regulation Test Lab No. TST1589, A2LA Certificate 3054.02).
As-Tested Installation Analysis
For air/water/structural and impact/cycle testing the test specimen was secured to a
2x Spruce-Pine-Fir buck. The as-tested installation method is evaluated on page 3 to
page 6. These capacities will be used to prove acceptable alternate anchors and
substrates for the windows.
Alternate Anchorages
Calculations on page 7 through page 9 determine the design capacity of alternate
through frame installation anchorages for the window.
Anchorage Requirements
The alternate through frame anchorage capacities exceed the as-tested through frame
anchorage. Thus, they are valid substitutions for the as-tested anchorage at the as-tested
anchorage spacing. It must be determined the anchorages are not overloaded for the
approved window size and design pressures. Calculations presented on page 10 show
the as-tested anchor spacing is adequate for the established anchor capacities.
Anchorage requirements are presented in Drawing D009346 (attached).
Attachments
Appendix A – Revision Log (1 page)
Appendix B – Drawings (16 pages)
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 3 of 10
As-Tested Installation – Nail Fin to Wood
#10 x 1-1/2" Pan Head Screw
0.062" thick Nail Fin
Spruce-Pine-Fir 2x Wood Substrate Minimum (G=0.42)
Allowable Tension of #10 x 1-1/2" Pan Head Screw
W = 1.0(1.500"-0.062")(95 lb/in) (NDS, Table 11.2B, CD = 1.0 as impact tested)
W = 137 lb
Allowable Pull-Over of #10 x 1-1/2" Pan Head Screw
Validated by Testing
Must maintain anchor spacing and anchor head size
As-tested spacing: 8" on center
As-tested anchor head size: 0.370"
Capacity of Connection is 137 lb
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 4 of 10
As-Tested Installation – Through Frame to Wood
#10 x 1-1/2" Pan Head Screw
0.062" thick Window Frame
1/4" Maximum Shim Space
Spruce-Pine-Fir 2x Wood Substrate Minimum (G=0.42)
Allowable Shear of #10 x 1-1/2" Pan Head Screw
Z' = 98 lb (See Following 2 Pages)
Bearing of #10 x 1-1/2" Pan Head Screw on Window Frame
Validated by Testing
Must maintain anchor spacing and anchor diameter
As-tested spacing: 16" on center
As-tested anchor diameter: 0.190"
Bending of #10 x 1-1/2" Pan Head Screw
L = 1/4" (maximum shim space)
S = πd3/32 = π(0.152)3/32 = 0.000345 in3
Fb = (1.3)(0.6Fy) = (1.3)(0.6)(90,000 psi) = 70,200 psi (1.3 weak axis factor)
Fb = M/S = (VL/2)/S (L/2 for guided bending)
V = 2SFb/L = (2)(0.000345 in)(70,200 psi)/0.25" = 194 lb.
Capacity of Connection is 98 lb
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 5 of 10
Alternate Installation – Through Frame to Wood (Continued)
Lateral Design Strength of Wood Connections
Data
Fastener
Fastener = #10 Wood Screw
Shank Dia = 0.190 in.
Root Dia. = 0.152 in.
Fyb = 80,000 psi
Fastener length = 1.500 in.
Main Member
Material = SPF
G = 0.42
θ = 90 <= (Angle of load to grain 0o < θ < 90o)
Fe = 3,350 psi
Thickness = 1.500 in.
Side Member
Material = 6063 T5 Aluminum USE ALUM FOR THICKNESS ONLY
G = N/A TEST GOVERNS AT FRAME
θ = 0 <= (Angle of load to grain 0o < θ < 90o)
Fes = 27,500 psi
Thickness = 0.062 in.
Calculations
Lateral Bearing Factors
D = 0.152 in.
ℓm = 1.058 in.
Kθ = 1.25
KD = 2.20
Re = 0.122
Rt = 17.06
k1 = 0.8328
k2 = 0.6286
k3 = 13.88
Yield Mode Rd
Im, I s 2.20
II 2.20
IIIm, IIIs, IV 2.20
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 6 of 10
Alternate Installation – Through Frame to Wood (Continued)
Lateral Design Values, Z
Mode Im = 245 lbf
Mode Is = 118 lbf
Mode II = 98 lbf MIN MAIN MEMBER VALUE
Mode IIIm = 124 lbf (SIDE MEMBER PROVEN BY TEST)
Mode IIIs = 94 lbf <====== Minimum Value
Mode IV = 133 lbf
CD = 1 1.0 for IMPACT TEST
Wet Service Factor
Fabrication/In-Service Dry/Dry
CM = 1.0
In service temperature T≤100˚F
Ct = 1.0
Cg = 1.0
C∆ = 1.0
Is fastener installed in end grain? No
Ceg = 1.00
Is fastener part of a diaphragm? No
Cdi = 1.0
Is fastener toe-nailed? No
Ctn = 1.00
Z' = 94 lbf USE 98 LB
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 7 of 10
Alternate Installation – Trough Frame to Steel Stud
#10-16 TEKS Screw
1/4" Maximum Shim Space
Minimum 18 gauge 33 KSI Steel Stud
Allowable Shear of #10-16 TEKS Screw
P s s /Ω = 5 73 lb (ESR-1976)
Bearing of #10-16 TEKS Screw on Frame
Do not exceed as-tested spacing
Bearing of #10-16 TEKS Screw on Steel Stud
Va = 2.7DtFtu/3.0
Va = 2.7(0.190")(0.0428")(45,000 psi)/3.0
Va = 329 lb.
Tilting of #10-16 TEKS Screw in Steel Stud
Va =4.2(t23D)1/2Ftu2/ns
Va = 4.2(0.0428"3 x 0.190")1/2(45,000 psi)/3.0
Va = 243 lb.
Bending of #10-16 TEKS Screw
L = 1/4" (Maximum Shim Space)
S = πd3/32 = π(0.135)3/32 = 0.000242 in3
Fb = (1.3)(0.6Fy) = (1.3)(0.6)(92,000 psi) = 71,760 psi (1.3 weak axis factor)
Fb = M/S = (VL/2)/S (L/2 for guided bending)
V = 2SFb/L = (2)(0.000242 in3)(71,760 psi)/0.25" = 139 lb.
Capacity of Connection is 139 lb.
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 8 of 10
Alternate Installation – Through Frame to Concrete
3/16" Tapcon Anchor
2-1/2" Minimum Edge Distance, 1-1/4" Minimum Embedment
1/4" Maximum Shim Space
Minimum f'c = 3,000 psi Concrete
Allowable Shear of 3/16" Tapcon Anchor
Pss /Ω = 181 lb (NOA-No. 16-1222.06)
Bearing of 3/16" Tapcon Anchor on Frame
Do not exceed as-tested spacing
Bending of 3/16" Tapcon Anchor
L = 1/4" (Maximum Shim Space)
S = πd3/32 = π(0.170")3/32 = 0.000482 in3
Fb = (1.3)(0.6Fy) = (1.3)(0.6)(137,000 psi) = 106,860 psi (1.3 weak axis factor)
Fb = M/S = (VL/2)/S (L/2 for guided bending)
V = 2SFb/L = (2)(0.000482 in3)(106,860 psi)/0.25" = 412 lb.
Capacity of Connection is 181 lb
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 9 of 10
Alternate Installation – Through Frame to CMU
3/16" Tapcon Anchor
2-1/2" Minimum Edge Distance, 1-1/4" Minimum Embedment
1/4" Maximum Shim Space
Minimum ASTM C90 Concrete Masonry Unit
Allowable Shear of 3/16" Tapcon Anchor
Pss /Ω = 135 lb (NOA-No. 16-1222.06)
Bearing of 3/16" Tapcon Anchor on Frame
Do not exceed as-tested spacing
Bending of 3/16" Tapcon Anchor
L = 1/4" (Maximum Shim Space)
S = πd3/32 = π(0.170")3/32 = 0.000482 in3
Fb = (1.3)(0.6Fy) = (1.3)(0.6)(137,000 psi) = 106,860 psi (1.3 for weak axis bending)
Fb = M/S = (VL/2)/S (L/2 for guided bending)
V = 2SFb/L = (2)(0.000482 in3)(106,860 psi)/0.25" = 412 lb.
Capacity of Connection is 135 lb
Jeld-Wen Windows & Doors NCTL-110-22068-1
Premium Atlantic Vinyl Impact HS Page 10 of 10
Anchorage Requirements – Nail Fin
Window Overall Size: 111" x 54"
Window Overall Area: (111")(54")/144 = 41.6 ft2
Window Overall Wind Load: (55 psf)(41.6 ft2) = 2,288 lb
Installed Anchor Spacing: 8" head; 8" sill; 8" each jamb
Installed Anchors: 14 head + 14 sill + 2(7) jambs = 42 installed anchors
Minimum Anchor Capacity: 137 lb/anchor
Total Anchor Capacity: (42 anchors)(137 lb/anchor) = 5,754 lb > 2,288 lb OK
Anchorage Requirements – Through Frame
Window Overall Size: 111" x 54"
Window Overall Area: (111")(54")/144 = 41.6 ft2
Window Overall Wind Load: (55 psf)(41.6 ft2) = 2,288 lb
Installed Anchors: 9 head + 9 sill + 2(4) jambs = 26 installed anchors
Minimum Anchor Capacity: 98 lb/anchor
Total Anchor Capacity: (26 anchors)(98 lb/anchor) = 2,548 lb > 2,288 lb OK
Appendix A
Revision Log
Identification Date Page & Revision
Original Issue 04/08/19 Not Applicable
Appendix B
Drawings
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019
Apr 10, 2019