WS2CI
WATER
SPECIALIST
CONTROL
VALVE
Certified to NSF/ANSI/CAN 61 and NSF/ANSI/CAN 372.
• 2” Top mount control valve suited for commercial/industrial applications
• Epoxy coated lead free brass valve body
• Economical stainless steel optional meter assembly
• Service flow rate of 435 lpm (26.1 m3/h) (115 gpm),
backwash 303 lpm (18.2 m3/h) (80 gpm)
• Solid state microprocessor with easy access front panel settings
• Front panel display for time of day, days until next regeneration,
volume remaining and current flow rate. Optional 2" Meter
• Four methods to initiate regeneration; meter immediate, meter delayed,
time clock delayed or pressure differential
• Program in ppm, French degrees, German degrees, or cubic meters
• Fully programmable regeneration cycle sequence (maximum 9)
• Programmable regeneration cycle times
• Days override feature; 1-28 days available
• Coin Cell Lithium battery back-up with an 24 hour carry over
• Level VI 15-volt output DC power supply provides safe and easy installation
• Pre or Post treated water regenerant refill
• 24 Hour Clock
• Reliable and proven DC drive
• One piece expanding seal spacer stack assembly
• Linearly reciprocating piston operation
Water Specialist 2” CI Control Specifications
Inlet/Outlet (1)............................................................................................ 2” Female BSPT or NPT
Cycles ....................................................................................................... Up to 9
Valve Material............................................................................................ Lead free brass
Regeneration............................................................................................. Downflow
CONTROL VALVE FLOW RATES
Service @ 1 bar/15 psi drop......................................................... 435 lpm (26.1 m3/h) (115 gpm)
Backwash @ 1.7 bar/25 psi drop................................................. 303 lpm (18.2 m3/h) (80 gpm)
Cv Service..................................................................................... 29.7
Cv Backwash................................................................................ 16.0
OPERATING PRESSURES
Minimum/Maximum...................................................................... 1.4 - 8.6 bar (20 psi - 125 psi)
OPERATING TEMPERATURES
Minimum/Maximum...................................................................... 4º - 43º C (40º - 110º F)
METER SPECIFICATIONS
Accuracy....................................................................................... ± 5%
Flow Rate Range........................................................................... 5.7 - 568 lpm (1.5 - 150 gpm)
Volume Range............................................................................... 0.02 - 5,700 m3
Totalizer......................................................................................... 1 - 99,999 m3
(264 - 26,417,000 gallons)
DIMENSIONS & WEIGHT
Distributor Pilot
Valve bodies with 2" Female BSPT Inlet & Outlet................ 50mm OD
Valve bodies with 2" Female NPT Inlet & Outlet.................. 1.90” OD (1.5" NPS)
Drain Line Connection.................................................................. 1.5” Female NPT
Brine Line Adapters Included....................................................... 1” Male NPT elbow,
¾” x 1” solvent weld elbow and
1
⁄2" OD Poly Tube Compression
Mounting Base.............................................................................. 4” - 8 UN
Height From Top Of Tank.............................................................. 216 mm (8.5”)
Shipping Weight With Meter........................................................ 13 Kg (29 lbs.)
ELECTRICAL SPECIFICATIONS POWER SUPPLY
U.S. International
Supply Voltage.................................................................... 100VAC to 120VAC.... 200VAC to 240VAC
Supply Frequency............................................................... 50/60 Hz..................... 50/60 Hz
Output Voltage.................................................................... 15VDC........................ 15VDC
Output Current.................................................................... 500 mA....................... 500 mA
TANK APPLICATIONS
Water Softener.............................................................................. 12” - 48” diameter
Water Filter (2)............................................................................... 12” - 36” diameter
CYCLES OF OPERATION
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
Cycle Range of values
Backwash...................................................................................... 1 - 120 minutes
Rinse.............................................................................................. 1 - 120 minutes
Pause (service).............................................................................. 1 - 480 minutes
Brine (co-current).......................................................................... 1 - 180 minutes
Refill (softener).............................................................................. 0.1 - 99.0 minutes
Refill (filter).................................................................................... 0.1 - 99.0 minutes
Options: Backwash Filter, Weather Cover
Compatible with the following typical concentrations of regenerants or chemicals: Sodium chloride, potassium
chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines
1. See Distributor Pilot
2. Filter tank size calculated @ 407 lpm per m2 of bed area /10 gpm of backwash per square foot of bed area
Form No. 2828 • 9/23/2021