Format No: SALLGN/TRF/GEN
Issue No:01, Issue Date: 01-04-2017
Page 1 of 3
CIN:U74220DL1998PLC092698 TEST REPORT
Test Report Issued To:
Test Report No: M200122016/M200122016-2
MM2MM PRODUCTS Date of Issue: 30-Jan-2020
A-611, GROMA HOUSE, PLOT NO. 14C, SECTOR-19,
VASHI, NAVI MUMBAI - 400705., NAVI MUMBAI,
MAHARASHTRA, INDIA, 400705,
Sample Booking/Receipt Date: 22-Jan-2020
Date of Start of Testing: 29-Jan-2020
Date of Completion of Test: 30-Jan-2020
Customer Relationship Number 52824
Sample Description :
ALUMINIUM FRAME (400 X 400 MM) EASY ACCESS
Customer Reference No :
TRF DT.
Kind Attention : MR. KISHOR SHAH
E-Mail: sales@[Link] Contact No: 9322671190
Sample Condition : GOOD CONDITION
Sample Quantity (Approx) : 1 NO Sample Size (Approx) : -
SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED
Digitally signed by
SAURABH KUMAR
SRIVASTAVA
Date: 2020.01.30
[Link] +05:30
Report Issued by
ULR-TC631420000002274F
Authencity of report can be verified by mail at verification@[Link]
This is a Digitally Signed Report and hence doesn't require Physical Signature.
Spectro Analytical Labs Limited S-1, GNEPIP, Surajpur Industrial Area,Phase-V, Kasna, Greater Noida-201308 (India)
Phone : +91-120-2341250,2341251 || URL : [Link] || Email: care@[Link]
BIS & DDA Approved, ISO 9001:2015, ISO 14001:2015 & ISO 45001:2018 Certified Laboratory
Please refer to our Website [Link] for Terms & Condition
Format No: SALLGN/TRF/GEN
Issue No: 01, Issue Date: 01.04.17
CIN: U74220DL1998PLC092698
TEST REPORT Page 2 of 3
Report No M200122016/M200122016-2
ID – M200122016-2
Mechanical Testing
[Link]. Test Parameter Observed Result Test Method
1 Ultimate tensile strength 272.9 IS 1608(Part-1) - 2018
(MPa)
2 Yield stress (MPa) 201.2 IS 1608(Part-1) - 2018
3 Elongation (%) 12.2 IS 1608(Part-1) - 2018
[GL – 50]
************
Digitally signed by
SAURABH KUMAR
ULR-TC631420000002274F SRIVASTAVA
Date: 2020.01.30
[Link] +05:30
Analyst Signature Testing(TC-6314) Authorised Signatory
BIS & DDA Approved, ISO 9001:2015, ISO 14001:2015 & ISO 45001:2018 Certified Laboratory
Format No: SALL/TRF/GEN
Issue No:01, Issue Date: 01-04-2017
Page 3 of 3
CIN: U74220DL1998PLC092698 TEST REPORT Report No M200122016/M200122016-2
ALUMINIUM ALLOY
Date: 1/29/2020 [Link]PM Program: Al-20-X
Sample ID: ID-M200122016-2 Comment: Al-Alloy
Element % TestMethod
*Aluminium 98.77 SOP/CHE/00-AL
Copper <0.005 ASTM E1251-2017a
Magnesium 0.556 --do--
Silicon 0.435 --do--
Iron 0.157 SOP/CHE/00-AL
Nickel <0.008 --do--
Manganese <0.012 ASTM E1251-2017a
Zinc <0.010 --do--
Lead 0.003 SOP/CHE/00-AL
Tin <0.002 --do--
Titanium 0.022 ASTM E1251-2017a
Chromium <0.005 --do--
Vanadium 0.019 --do--
Note : * (Element not covered in NABL Scope)
--- --- --- --- --- --- ---
-- End of Test Report --
Digitally signed
by JAI
ULR-TC631420000002274F BHAGWAN
Date: 2020.01.29
[Link] +05:30
Analyst Signature Testing(TC-6314) Authorised Signatory
Spectro Analytical Labs Limited S-1, GNEPIP, Surajpur Industrial Area, Phase-V, Kasna, Greater Noida - 201308 (India)
Phone : +91-120-2341250,2341251 || URL : [Link] || Email : care@[Link]
BIS & DDA Approved, ISO 9001:2015, ISO 14001:2015 & ISO 45001:2018 Certified Laboratory
Format No: SALLGN/TRF/GEN
Issue No:01, Issue Date: 01-04-2017
Page 1 of 2
CIN:U74220DL1998PLC092698 TEST REPORT
Test Report Issued To:
Test Report No: M200122016/M200122016-1
MM2MM PRODUCTS Date of Issue: 28-Jan-2020
A-611, GROMA HOUSE, PLOT NO. 14C, SECTOR-19,
VASHI, NAVI MUMBAI - 400705., NAVI MUMBAI,
MAHARASHTRA, INDIA, 400705,
Sample Booking/Receipt Date: 22-Jan-2020
Date of Start of Testing: 27-Jan-2020
Date of Completion of Test: 28-Jan-2020
Customer Relationship Number 52824
Sample Description :
GYPSUM MR BOARD (400 X 400 MM) EASY ACCESS TRAP
DOOR
Customer Reference No :
TRF DT.
Kind Attention : MR. KISHOR SHAH
E-Mail: sales@[Link] Contact No: 9322671190
Sample Condition : GOOD CONDITION
Sample Quantity (Approx) : 1 NO Sample Size (Approx) : -
SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED
Digitally signed
by ANSHUL
KUMAR
Date: 2020.01.28
[Link] +05:30
Report Issued by
Authencity of report can be verified by mail at verification@[Link]
This is a Digitally Signed Report and hence doesn't require Physical Signature.
Spectro Analytical Labs Limited S-1, GNEPIP, Surajpur Industrial Area,Phase-V, Kasna, Greater Noida-201308 (India)
Phone : +91-120-2341250,2341251 || URL : [Link] || Email: care@[Link]
BIS & DDA Approved, ISO 9001:2015, ISO 14001:2015 & ISO 45001:2018 Certified Laboratory
Please refer to our Website [Link] for Terms & Condition
Format No: SALLGN/TRF/GEN
Issue No: 01, Issue Date: 01.04.17
CIN: U74220DL1998PLC092698
TEST REPORT Page 2 of 2
Report No. M200122016/M200122016-1
GYPSUM MR BOARD
Observed
[Link]. Test Parameter Test method
Value
1.
Water Resistance ,% 35 ASTM C 473
2. Nail Pull Resistance,N 120 ASTM C 473
-- End of Test Report --
Digitally signed
by ANSHUL
KUMAR
Date: 2020.01.28
[Link] +05:30
Analyst Signature Authorised Signatory
BIS & DDA Approved, ISO 9001:2015, ISO 14001:2015 & ISO 45001:2018 Certified Laboratory