DOMETIC REFERENCE GUIDE VERSION 1.

13
104 lbs. 14.4”
83 lbs. 119 lbs.

27.6”
29.6”

71 lbs.

11.5”

105 lbs. 90 lbs. 128 lbs.


Has been obsolete for a few years The CCC 4 BUTTON has been The CCC 5 BUTTON, while
BI-METAL obsolete for many years. It technically an older version of
now. Replaced by a special CT
Thermostat – NOT to was (and still can be) the multi-zone controls, it is
Control Kit (noted in the CT section of
be confused with the replaced by the CCC 5 still supported and available The CCC 2 10 BUTTON is the current
Analog Thermostat the Cheat Sheet – PN: 3316155.700).
This kit is NLA so the customer can BUTTON for purchase. multi-zone control system.
120VAC System
try aftermarket or get a Honeywell
stat if JUST the stat is needed.

If a replacement is needed of For NEW installations, we


It is directly replaced by the
either the thermostat or the should really push the
CT Thermostat depending
control box, the customer has customer to a CCC2 10
The ANALOG Thermostat on Cool Only, Heat Pump, or
the option to go to a 5 BUTTON, unless the OLD
has been obsolete for Heat Strip.
BUTTON or a 10 BUTTON. IF remaining AC unit or ANY
several years.
the unit (or any of the units) other AC unit in the Multi-
is an older first-generation zone setup is an older, first-
Heat Pump, they can ONLY go generation Heat Pump.
to the 5 BUTTON. The 10
BUTTON is NOT compatible to
older first gen Heat Pumps.
3106986.007 CABLE ADAPTER KIT
CONVERSION TO COMFORT CONTROL CENTER
This kit will convert Plug-n-Play units using the old Digital Control that used a 10-pin ribbon cable through the wall between the thermostat
and the control box to work with a CCC 5 Button or CCC II 10 Button (depending on what upper unit they have - Cool Only vs. Heat Pump).
If upper unit is a First-Generation Heat Pump, they If upper unit is a Cool Only or anything Second Gen, they can use
will need 5 Button Equipment (T-Stat & Control BOX): 10 Button Equipment (T-Stat & Control BOX):
Control Box = 3109226.005 Control Box = 3312020.000
T-Stat (Black) = 3109228.019 T-Stat (Black) = 3314082.000 -or- T-Stat (White) = 3314082.011
T-stat PCB

T-stat Base
Wall
Thermostat

RJ-11
10-Pin Ribbon to Cable
Upper Control Box
Customers that need replacement of a Penguin with controls matching the image
below (either on a flip down on the ADB or wall control) will need to consider it a
“complete replacement”. They will need a new roof top unit, new controls, and to
run new wiring appropriate for that control type through the wall.
REMOTE Dometic does not offer a wireless remote for Air Conditioning currently. If a replacement is needed, the direction we
should advise the customer depends on the location of the “RECEIVER” (picture below).

If the Receiver is located on the wall (comparable to where a wall thermostat could be located), this will be the easiest
replacement. The Receiver uses the same RJ-11 cable that the Multi-Zone control systems (CCC 5 Button & CCC2 10 Button)
do. In this case, if it is a COOL only – NON-Heat Pump order CCC2 equipment (Control Box & Wall Thermostat). If it was a
Heat Pump, order CCC 5 Button equipment (Control Box & Wall Thermostat).
CCC2 10 Button Control Box = 3312020.000
CCC2 10 Button White Thermostat = 3314082.011
CCC2 10 Button Black Thermostat = 3314082.000

CCC 5 Button Control Box = 3109226.005


CCC 5 Button Black (White NLA) Thermostat = 3109228.019

If the Receiver is located on the ceiling (normally near the ADB or Quick Cool Vent), then the customer can choose to either
install a CT Single Zone system or CCC2 system as wiring will need to be ran down the wall to an acceptable wall thermostat
location (54” from the floor, on an inside wall, that has good air movement, but is NOT affected by ducts / vents).
CT Cool / Furnace Control Kit White = 3316230.700
CT Cool / Furnace Control Kit Black = 3316230.714
CT Heat Strip Control Kit White = 3316232.700
CT Heat Strip Control Kit Black = 3316232.714
CT Heat Pump Control Kit White = 3316234.700
CT Heat Pump Control Kit Black = 3316234.714
PN :[Link] PN: 3314851.000 PN: FJXADBMWH
PN: [Link] PN: 3314852.000 (HP) *compatible to FreshJet 3000s,
PN: [Link] (HE) PN: 3314853.000 (65001X Penguin II) Brisk II, High Performance, & Blizzard*
PN: [Link] (Penguin I) PN: 3314854.000 (HE)
PN: [Link] (Penguin I) *compatible to all generations*

PN: [Link] PN: 3314850.000 PN: FJXADBNWH


*compatible to all generations* *compatible to FreshJet 3000s
Brisk II, High Performance, & Blizzard*
NOTES: Keep in mind, with some of these kits becoming NLA from our supplier, if a customer is in need of one of the
above conversions, and we do not have any to offer, the customer can either look online / aftermarket, or…
potentially “build the kit”. For example;
The 3313107.107 kit consists of three individual things; the 5-Button Board, Conversion Instructions, and
the Old Style Outdoor Ambient sensor…
- 5-Button Board PN: 3311557.000
- Outdoor Ambient Sensor PN: 3310732.007
- Conversion Instructions are located in the “Common Files”
If we have the individual parts (or the customer can find the parts online) we can email them the conversion
instructions and the customer would have everything they need from the NLA 3313107.107 kit.
FJX 0 0 0 0 A BC DE F G H IJ -K
Model Family : FJX
Technology : 3=Fixed speed compressors with single motor, 4=Fixed speed compressors with dual motor, 5=Triac, 6=Inverter with
single motor, 7=Inverter with dual motor
Compressor size² : 1=up to 1000W (3.5kBTU), 2=up to 2000W (7kBTU), 3=up to 3000W (10kBTU), 4=up to 4000W (14kBTU), 5=up to
5000W (17kBTU)
Height³ : 3=up to 230mm (9in), 5=from 231mm (9.1in) to 270mm (10.6in), 7=from 271mm (10.7in)
Footprint⁴ : 3=up to 0.525m2 (5.7ft2), 5=from 0.526m2 (5.7ft2) to 0.660m2 (7.1ft2), 7=from 0.661m2 (7.1ft2)
Mechanical/El : M=mechanical, E=FS electronics, T=triac, I=inverter
Climate Application : Blank (no letter to be written)=no heating, HP=heat pump, HE=high efficiency, EH=electrical heater
Color : BK=black, WH=white, RD=red, BL=blue, GY=grey, GR=green
Refrigerant : A=R410a, B=R407c, C=R32
Top or bottom mount : S=dual mount (bottom and top mount), B=bottom mount only, T=top mount only
External LED : Blank (no letter to be written)=no external LED, L=LED white, R=LED multicolor
Packaging : Blank (no letter to be written)=no industrial packaging, IP=Industrial packaging (bulk packaging)
Segment : Blank (no letter to be written)=AMERICAS, -A=EMEA version, -B=APAC version
x x xxx x . xxxxx
Configuration:
Air Conditioner
7915 = 13,500 BTU
7935 = 13,500 BTU w/ Heat Strip
Generation: 9516 = 15,000 BTU
4 = Brisk 9536 = 15,000 BTU w/ Heat Strip
B = Brisk II 9530 = Hi Efficiency
Heat Pump (Energized in Cool Mode)
9136 = 15,000 BTU, CCC (5 Button)
9146 = 15,000 BTU, Analog
Grade: 9156 = 15,000 BTU, SZLCD / CT
5 = Standard Heat Pump (Energized in Heat Mode)
7 = Commercial 9186 = 15,000 BTU, CCC2 (10 Button)
9196 = 15,000 BTU, SZLCD / CT

Place Holder & Shroud Color:


XX1C0 = White Shroud
XX1J0 = Black Shroud
*(XX is replaced by 71 on data tag)
WHAT IS YOUR MODEL NUMBER?
NEW MODEL NUMER ENDING
WHAS = WHITE SHROUD
57908 = 7,100 BTU = NLA 57912 = 11,000 BTU = NLA 57915 / 457915 / B57915 ► FJX3473M = 13,500 BTU 59516 / 459516 / B59516 ► FJX3573M = 15,00 BTU BKAS = BLACK SHROUD

IF THE UNIT IS CONTROLLED MANUALLY WITH AN ADB (KNOBS ON THE CEILING BOX) IF THE UNIT IS CONTROLLED WITH A WALL THERMOSTAT

REPLACING A/C OR ADB? OPTIONAL HEAT STRIP PART NUMBER ARE YOU REPLACING THE A/C, ADB, CONTROL BOX OR THERMOSTAT?
3314998.000
*FreshJets ONLY COMPATIBLE with Heat Strips
using either Universal ADBs ORDER: ADB
ORDER: A/C ORDER: ADB ORDER: A/C FJXADBNWH CONTROL BOXES
3314851.000 (mechanical)
FJX3473M = 13.5K FJXADBMWH
–or- FJX3473M = 13.5K *Not 1st Gen Compatible* & THERMOSTATS
- OR - *Not 1st Gen Compatible* FJX3573M = 15K - OR –
3314850.000 with corresponding control/stat
FJX3573M = 15K - OR – 3314850.000
3314851.000
WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
NOTE: WHEN
HEAT STRIP CONTROL KIT W/ T-STAT CONTROL BOX REPLACING AN OLDER
3316232.700 = WHITE (WITHOUT T-STAT) BRISK ONE (1ST GEN)
3316232.710 = BLACK 3109226.005 WITH A BRISK TWO
OR A FRESHJET UNIT,
A NEW ADB MUST BE
INSTALLED AS WELL.
120VAC
HOW MANY BTU’S DO YOU WANT?

NEW MODEL NUMER ENDING


WHAS= WHITE SHROUD
FJX3473M = 13,500 BTU FJX3573M = 15,00 BTU BKAS = BLACK SHROUD

DO YOU WANT MECHANICAL CONTROLS (KNOBS ON ADB – NO WALL THERMOSTAT)? DO YOU WANT A WALL THERMOSTAT?

FOR MECHANICALLY CONTROLLED INSTALLATIONS OPTIONAL HEAT STRIP PART NUMBER FOR WALL THERMOSTAT INSTALLATIONS
3314998.000
*FreshJets ONLY COMPATIBLE with Heat Strips
using either Universal ADBs
ORDER: A/C ORDER: ADB 3314851.000 (mechanical) ORDER: A/C ORDER: ADB CONTROL BOXES
FJX3473M = 13.5K FJXADBMWH –or- FJX3473M = 13.5K FJXADBNWH & THERMOSTATS
- OR - - OR – 3314850.000 with corresponding control/stat FJX3573M = 15K - OR –
FJX3573M = 15K 3314851.000 3314850.000

WHAT THERMOSTAT DO YOU NEED?

C/T NOTE: CCC II (10 BUTTON)


NOTE: MULTI-ZONE INSTALLATIONS
SINGLE ZONE INSTALLATIONS USE A DATA CABLE THERMOSTAT ONLY
CONTROL KIT (BOX & T-STAT) FOR
ONLY USE (3) 16-22 GUAGE THROUGH THE WALL THAT 3314082.011 = WHITE
COOL / FURNACE
WIRES THROUGH THE WALL. LOOKS LIKE STANDARD 3314082.000 = BLACK
3316230.700 = WHITE
3316230.714 = BLACK TELEPHONE CABLE.
HOWEVER, POLARITY IS CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY DIFFERENT AND A 3312020.000
3316250.700 = WHITE STANDARD TELEPHONE
3316250.712 = BLACK CABLE WILL NOT WORK.

STRAIGHT THROUGH
COMMUNICATION CABLE
PART NUMBERS:
18 FT. = 3106614.013
40 FT. = 3308013.022
WHAT IS YOUR MODEL NUMBER? NEW MODEL NUMER ENDING
WHAS = WHITE SHROUD
BKAS = BLACK SHROUD

57908 = 7,100 BTU = NLA 57912 = 11,000 BTU = NLA 57915 / 457915 / B57915 ► FJX3473M = 13,500 BTU 59516 / 459516 / B59516 ► FJX3573M = 15,00 BTU

ARE YOU REPLACING THE A/C, CONTROL BOX, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL)?

REPLACING A/C CEILING ASSEMBLY (RETURN AIR GRILL) CONTROL KIT, BOX, OR THERMOSTAT

OPTIONAL HEAT STRIP PART


NUMBER ORDER: A/C ORDER
3315450.000 FJX3473M = 13.5K 3317404.000
*ONLY COMPATIBLE WITH - OR -
BRISK II AC UNITS AND NON-FJ FJX3573M = 15K
ADB – Heat Strips are NOT
compatible with FJ units in a
DUCTED application. WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
HEAT STRIP CONTROL KIT W/ T-STAT CONTROL BOX
3316232.700 = WHITE (WITHOUT T-STAT)
3316232.710 = BLACK 3109226.005

120VAC
HOW MANY BTU’S DO YOU WANT?

NEW MODEL NUMER ENDING


WHAS = WHITE SHROUD
FJX3473M = 13,500 BTU FJX3573M = 15,00 BTU BKAS = BLACK SHROUD

WHAT THERMOSTAT DO YOU WANT?

NOTE:
SINGLE ZONE INSTALLATIONS C/T NOTE: CCC II (10 BUTTON)
ONLY USE (3) 16-22 GUAGE MULTI-ZONE INSTALLATIONS USE A
CONTROL KIT (BOX & T-STAT) FOR DATA CABLE THROUGH THE WALL THAT THERMOSTAT ONLY
WIRES THROUGH THE WALL.
COOL / FURNACE LOOKS LIKE STANDARD TELEPHONE 3314082.011 = WHITE
3316230.700 = WHITE CABLE. HOWEVER, POLARITY IS 3314082.000 = BLACK
3316230.714 = BLACK DIFFERENT AND A STANDARD
TELEPHONE CABLE WILL NOT WORK. CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY 3312020.000
3316250.700 = WHITE
STRAIGHT THROUGH COMMUNICATION RETURN AIR GRILLE (QUICK COOL
3316250.712 = BLACK
CABLE PART NUMBERS: VENT)
RETURN AIR GRILLE (QUICK COOL 18 FT. = 3106614.013 3317404.000
VENT) 40 FT. = 3308013.022
3317404.000

NOTE: Heat Strips are


NOT compatible with
FreshJet units in a
DUCTED application.
WHAT IS YOUR MODEL NUMBER?

459146 / B59146 = 15,000 BTU = NLA 459156 = 15,000 BTU = NLA 459196 ► B59196 = 15,000 BTU 459186 / B59186 = 15,000 BTU = NLA 59136 / 459136 = 15,000 BTU = NLA

ARE YOU REPLACING THE A/C, AIR DISTRIBUTION BOX (ADB), CONTROL BOX, OR THERMOSTAT?

A/C ONLY A/C ONLY A/C ONLY A/C ONLY A/C ONLY
• IF UNIT IS USING A MECHANICAL ORDER: ORDER: ORDER: ORDER:
ADB (KNOBS IN THE CEILING B59196.XX1C0 = WHITE B59196.XX1C0 = WHITE 651816HXX1C0-01 = WHITE 651816HXX1C0-01 = WHITE
ASSEM.) ORDER: 650016 B59196.XX1J0 = BLACK B59196.XX1J0 = BLACK 651816HXX1J0-01 = BLACK 651816HXX1J0-01 = BLACK
CXX1C = WHITE – CXX1J0 = BLACK AND NEW ADB: IF ORIGINAL MODEL WAS 459196; IF ORIGINAL MODEL WAS 459186; ORDER NEW ADB: FJXADBNWH
& NEW UNIVERSAL ADB: FJXADBNWH ORDER NEW ADB: FJXADBNWH ORDER NEW ADB: FJXADBNWH *IF THE UNIT WAS ISOLATED TO JUST
3314853.000 ONE ZONE CHANGE THE WALL
• IF THE UNIT IS USING AN ANALOG THERMOSTAT ONLY THERMOSTAT ONLY THERMOSTAT ONLY THERMOSTAT TO A 10 BUTTON CCC II.
WALL THERMOSTAT ORDER: 3314082.011 = WHITE T-STAT
651916 ORDER: ORDER: ORDER: 3314082.000 = BLACK T-STAT
HXX1C0-01=WHITE/HXX1J0-01=BLACK 3316250.700 = WHITE T-STAT 3316250.700 = WHITE T-STAT 3314082.011 = WHITE T-STAT *IF THE UNIT WAS IN LINE WITH
& A NEW C/T WALL THERMOSTAT 3316250.712 = BLACK T-STAT 3316250.712 = BLACK T-STAT 3314082.000 = BLACK T-STAT MULTIPLE ZONES, ORDER
& NEW ADB: CONVERSION KIT FOR THE NEW AC
3316250.700 = WHITE T-STAT CONTROL BOX ONLY CONTROL BOX ONLY CONTROL BOX ONLY CONVERSOIN KIT: 3313107.119
3316250.712 = BLACK T-STAT
ORDER COMPLETE KIT: ORDER COMPLETE KIT: ORDER:
FJXADBNWH = NEW ADB THERMOSTAT ONLY
3316234.700 = WHITE T-STAT 3316234.700 = WHITE T-STAT 3312020.000
THERMOSTAT OR CONTROL BOX 3316234.716 = BLACK T-STAT 3316234.716 = BLACK T-STAT ORDER:
OPEN CONTROL BOX AND 3109228.001 = WHITE T-STAT (NLA)
IF EITHER FAIL, NEED TO REPLACE MOVE REV VALVE WIRE FROM 3109228.019 = BLACK T-STAT
BOTH WITH COMPLETE CT KIT Y5 TO Y10
3316234.700 = WHITE T-STAT CONTROL BOX ONLY
3316234.716 = BLACK T-STAT ADB ONLY ADB ONLY ADB ONLY
OPEN CONTROL BOX AND MOVE REV ORDER: 3109226.005
VALVE WIRE FROM Y5 TO Y10 ORDER: ORDER: ORDER:
FJXADBNWH FJXADBNWH FJXADBNWH ADB ONLY
AIR DISTRIBUTION BOX *Not 1st Gen Compatible* *Not 1st Gen Compatible* *Not 1st Gen Compatible*
- OR – - OR – - OR – ORDER:
MECHANICAL: 3314852.000
3314850.000 3314850.000 3314850.000 FJXADBNWH – Not 1st Gen Compatible
NON-MECHANICAL: FJXADBNWH
- OR –
- OR –
3314850.000
NON-MECHANICAL: 3314850.000
WHAT IS YOUR MODEL NUMBER?

45914 / B59146 = 15,000 BTU = NLA 459156 = 15,000 BTU = NLA 459196 ► B59196 = 15,000 BTU 459186 / B59186 = 15,000 BTU = NLA 59136 / 459136 = 15,000 BTU = NLA

ARE YOU REPLACING THE A/C, RETURN AIR GRILL, CONTROL BOX, OR THERMOSTAT?

A/C ONLY A/C ONLY A/C ONLY A/C ONLY A/C ONLY
ORDER: 651916 ORDER: ORDER: ORDER: ORDER:
HXX1C0-01=WHITE/HXX1J0-01=BLACK B59196.XX1C0 = WHITE B59196.XX1C0 = WHITE 651816HXX1C0-01 = WHITE 651816HXX1C0-01 = WHITE
& A NEW C/T WALL THERMOSTAT B59196.XX1J0 = BLACK B59196.XX1J0 = BLACK 651816HXX1J0-01 = BLACK 651816HXX1J0-01 = BLACK
3316250.700 = WHITE T-STAT *IF THE UNIT WAS ISOLATED TO JUST
3316250.712 = BLACK T-STAT THERMOSTAT ONLY THERMOSTAT ONLY THERMOSTAT ONLY ONE ZONE CHANGE THE WALL
THERMOSTAT TO A 10 BUTTON CCC II.
THERMOSTAT OR CONTROL BOX ORDER: ORDER: ORDER: 3314082.011 = WHITE T-STAT
3316250.700 = WHITE T-STAT 3316250.700 = WHITE T-STAT 3314082.011 = WHITE T-STAT 3314082.000 = BLACK T-STAT
IF EITHER FAIL, NEED TO REPLACE 3316250.712 = BLACK T-STAT 3316250.712 = BLACK T-STAT 3314082.000 = BLACK T-STAT *IF THE UNIT WAS IN LINE WITH
BOTH WITH COMPLETE CT KIT MULTIPLE ZONES, ORDER
3316234.700 = WHITE T-STAT CONTROL BOX ONLY CONTROL BOX ONLY CONTROL BOX ONLY CONVERSION KIT FOR THE NEW AC
3316234.716 = BLACK T-STAT CONVERSOIN KIT: 3313107.107
OPEN CONTROL BOX AND MOVE REV ORDER COMPLETE KIT: ORDER COMPLETE KIT: ORDER:
VALVE WIRE FROM Y5 TO Y10 3316234.700 = WHITE T-STAT 3316234.700 = WHITE T-STAT 3312020.000
3316234.716 = BLACK T-STAT 3316234.716 = BLACK T-STAT THERMOSTAT ONLY
RETURN AIR GRILL ONLY OPEN CONTROL BOX AND ORDER:
MOVE REV VALVE WIRE FROM 3109228.001 = WHITE T-STAT (NLA)
ORDER: 3317404.000 Y5 TO Y10 3109228.019 = BLACK T-STAT

RETURN AIR GRILL ONLY RETURN AIR GRILL ONLY RETURN AIR GRILL ONLY CONTROL BOX ONLY
ORDER: 3317404.000 ORDER: 3317404.000 ORDER: 3317404.000 ORDER: 3109226.005

RETURN AIR GRILL ONLY


ORDER: 3317404.000
NO HEAT STRIP WHAT IS YOUR MODEL NUMBER?
OPTION AVAILABLE
FOR THIS *NEW MODEL NUMER ENDING
INSTALLATION TYPE .XX1C0 = WHITE SHROUD
52528/59529 = NLA UPGRADE TO B59530 59530/459530 ► B59530 .XX1J0 = BLACK SHROUD

IF THE UNIT IS CONTROLLED MANUALLY WITH AN ADB (KNOBS ON THE CEILING BOX) IF THE UNIT IS CONTROLLED WITH A WALL THERMOSTAT

REPLACING A/C OR ADB? ARE YOU REPLACING THE A/C, ADB, CONTROL BOX OR THERMOSTAT?

ORDER: A/C ORDER: ADB ORDER: A/C ORDER: ADB CONTROL BOXES
B59530 3314854.000 B59530 FJXADBNWH & THERMOSTATS
- OR –
3314850.000

WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
CONTROL BOX
(WITHOUT T-STAT)
3109226.005

120VAC
NO HEAT STRIP B59530
OPTION AVAILABLE *NEW MODEL NUMER ENDING
FOR THIS .XX1C0 = WHITE SHROUD
INSTALLATION TYPE WHAT TYPE OF INSTALLATION DO YOU WANT? .XX1J0 = BLACK SHROUD

DO YOU WANT MECHANICAL CONTROLS (KNOBS ON ADB – NO WALL THERMOSTAT)? DO YOU WANT A WALL THERMOSTAT?

FOR MECHANICALLY CONTROLLED INSTALLATIONS FOR WALL THERMOSTAT INSTALLATIONS

ORDER: A/C ORDER: ADB ORDER: A/C ORDER: ADB CONTROL BOXES
B59530 3314854.000 B59530 FJXADBNWH & THERMOSTATS
- OR –
3314850.000

WHAT THERMOSTAT DO YOU NEED?

C/T NOTE: CCC II (10 BUTTON)


NOTE: MULTI-ZONE INSTALLATIONS
SINGLE ZONE INSTALLATIONS USE A DATA CABLE THERMOSTAT ONLY
CONTROL KIT (BOX & T-STAT) FOR
ONLY USE (3) 16-22 GUAGE THROUGH THE WALL THAT 3314082.011 = WHITE
COOL / FURNACE
WIRES THROUGH THE WALL. LOOKS LIKE STANDARD 3314082.000 = BLACK
3316230.700 = WHITE
3316230.714 = BLACK TELEPHONE CABLE.
HOWEVER, POLARITY IS CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY DIFFERENT AND A 3312020.000
3316250.700 = WHITE STANDARD TELEPHONE
3316250.712 = BLACK CABLE WILL NOT WORK.

STRAIGHT THROUGH
COMMUNICATION CABLE
PART NUMBERS:
18 FT. = 3106614.013
40 FT. = 3308013.022
NO HEAT STRIP WHAT IS YOUR MODEL NUMBER? * NEW MODEL NUMER ENDING
OPTION AVAILABLE .XX1C0 = WHITE SHROUD
FOR THIS .XX1J0 = BLACK SHROUD
INSTALLATION TYPE
52528/59529 = NLA UPGRADE TO B59530 59530/459530 ► B59530

ARE YOU REPLACING THE A/C, CONTROL BOX, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL)?

REPLACING A/C CEILING ASSEMBLY (RETURN AIR GRILL) CONTROL KIT, BOX, OR THERMOSTAT

ORDER: A/C ORDER


B59530 3317404.000

WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
CONTROL BOX
(WITHOUT T-STAT)
3109226.005

120VAC
NO HEAT STRIP
OPTION AVAILABLE * MODEL NUMER ENDING
FOR THIS .XX1C0 = WHITE SHROUD
B59530
INSTALLATION TYPE .XX1J0 = BLACK SHROUD

WHAT THERMOSTAT DO YOU WANT?

NOTE:
SINGLE ZONE INSTALLATIONS C/T NOTE: CCC II (10 BUTTON)
ONLY USE (3) 16-22 GUAGE MULTI-ZONE INSTALLATIONS
CONTROL KIT (BOX & T-STAT) FOR USE A DATA CABLE THERMOSTAT ONLY
WIRES THROUGH THE WALL.
COOL / FURNACE THROUGH THE WALL THAT 3314082.011 = WHITE
3316230.700 = WHITE LOOKS LIKE STANDARD 3314082.000 = BLACK
3316230.714 = BLACK TELEPHONE CABLE.
HOWEVER, POLARITY IS CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY 3312020.000
DIFFERENT AND A
3316250.700 = WHITE
STANDARD TELEPHONE RETURN AIR GRILLE (QUICK COOL
3316250.712 = BLACK
CABLE WILL NOT WORK. VENT)
RETURN AIR GRILLE (QUICK COOL 3317404.000
VENT) STRAIGHT THROUGH
3317404.000 COMMUNICATION CABLE
PART NUMBERS:
18 FT. = 3106614.013
40 FT. = 3308013.022
B57935 (13.5k) = NLA – REPLACE WITH FJX3473 * MODEL NUMER ENDING
MWHAS = WHITE SHROUD
B59536 (15k) = NLA – REPLACE WITH FJX3573 MBKAS = BLACK SHROUD

CUSTOMER CAN USE EXISITING HEAT STRIP AND CONTROL BOX /


THERMOSTAT FROM DEFECTIVE UNIT AS LONG AS THERE IS NOTHING
WRONG WITH THOSE ITEMS.

IF REPLACEMENT HEAT STRIP IS NEEDED ORDER - 3315450.000 IF REPLACEMENT CONTROL KIT OR


THERMOSTAT IS NEEDED:
THERMOSTAT ONLY
3316250.700 = WHITE
3316250.712 = BLACK
HEAT STRIP CONTROL KIT W/ T-STAT
3316232.700 = WHITE
3316232.710 = BLACK
WHAT IS YOUR MODEL NUMBER?

*NEW MODEL NUMER ENDING


.XX1C0 = WHITE SHROUD
477915 = 13,500 BTU – NLA UPGRADE TO 15,000 = B79516 479516 ► B79516 = 15,000 BTU .XX1J0 = BLACK SHROUD

IF THE UNIT IS CONTROLLED MANUALLY WITH AN ADB (KNOBS ON THE CEILING BOX) IF THE UNIT IS CONTROLLED WITH A WALL THERMOSTAT

REPLACING A/C OR ADB? ARE YOU REPLACING THE A/C, ADB, CONTROL BOX OR THERMOSTAT?
OPTIONAL HEAT STRIP
PART NUMBER
3314998.000 ORDER: ADB
ORDER: A/C ORDER: ADB *ONLY COMPATIBLE WITH ORDER: A/C FJXADBNWH CONTROL BOXES
B79516 – IF UNIT FJXADBMWH NEWER UNIVERSAL ADB B79516 *Not 1st Gen Compatible* & THERMOSTATS
WAS 477915 AND *Not 1st Gen Compatible* - OR –
USED OLDER ADB – - OR – 3314850.000
MUST ALSO 3314851.000
REPLACE NEW WHAT THERMOSTAT DO YOU HAVE?
UNIVERSAL ADB –
FJXADBMWH

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE
3316250.712 = BLACK 3109228.019 = BLACK
HEAT STRIP CONTROL KIT W/ T-STAT CONTROL BOX
3316232.700 = WHITE (WITHOUT T-STAT)
3316232.710 = BLACK 3109226.005

120VAC
B79516 = 15,00 BTU

*NEW MODEL NUMER ENDING


.XX1C0 = WHITE SHROUD
WHAT TYPE OF INSTALLATION DO YOU WANT? .XX1J0 = BLACK SHROUD

DO YOU WANT MECHANICAL CONTROLS (KNOBS ON ADB – NO WALL THERMOSTAT)? DO YOU WANT A WALL THERMOSTAT?

FOR MECHANICALLY CONTROLLED INSTALLATIONS FOR WALL THERMOSTAT INSTALLATIONS


OPTIONAL HEAT STRIP
PART NUMBER
3314998.000
ORDER: A/C ORDER: ADB *ONLY COMPATIBLE WITH ORDER: A/C ORDER: ADB CONTROL BOXES
B79516 = 15K BTU FJXADBMWH BRISK II AC UNITS AND B79516 = 15K BTU FJXADBNWH & THERMOSTATS
- OR – NON-FJ ADB - OR –
3314851.000 3314850.000

WHAT THERMOSTAT DO YOU NEED?

C/T NOTE: CCC II (10 BUTTON)


NOTE: MULTI-ZONE INSTALLATIONS
SINGLE ZONE INSTALLATIONS USE A DATA CABLE THERMOSTAT ONLY
CONTROL KIT (BOX & T-STAT) FOR
ONLY USE (3) 16-22 GUAGE THROUGH THE WALL THAT 3314082.011 = WHITE
COOL / FURNACE
WIRES THROUGH THE WALL. LOOKS LIKE STANDARD 3314082.000 = BLACK
3316230.700 = WHITE
3316230.714 = BLACK TELEPHONE CABLE.
HOWEVER, POLARITY IS CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY DIFFERENT AND A 3312020.000
3316250.700 = WHITE STANDARD TELEPHONE
3316250.712 = BLACK CABLE WILL NOT WORK.
HEAT STRIP CONTROL KIT W/ T-STAT
3316232.700 = WHITE STRAIGHT THROUGH
3316232.710 = BLACK COMMUNICATION CABLE
PART NUMBERS:
18 FT. = 3106614.013
40 FT. = 3308013.022
WHAT IS YOUR MODEL NUMBER? * NEWMODEL NUMER ENDING
.XX1C0 = WHITE SHROUD
.XX1J0 = BLACK SHROUD
477915 = 13,500 BTU – NLA UPGRADE TO 15,000 = B79516 479516 ► B79516 = 15,000 BTU

ARE YOU REPLACING THE A/C, CONTROL BOX, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL)?

REPLACING A/C CEILING ASSEMBLY (RETURN AIR GRILL) CONTROL KIT, BOX, OR THERMOSTAT

OPTIONAL HEAT STRIP ORDER: A/C ORDER


PART NUMBER B79516 = 15K BTU 3317404.000
3315450.000
NOT INTERCHANGABLE

WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
HEAT STRIP CONTROL KIT W/ T-STAT CONTROL BOX
3316232.700 = WHITE (WITHOUT T-STAT)
3316232.710 = BLACK 3109226.005

120VAC
* MODEL NUMER ENDING
B79516 = 15,000 BTU .XX1C0 = WHITE SHROUD
.XX1J0 = BLACK SHROUD

WHAT THERMOSTAT DO YOU WANT?

NOTE: C/T NOTE: CCC II (10 BUTTON)


SINGLE ZONE INSTALLATIONS MULTI-ZONE INSTALLATIONS
CONTROL KIT (BOX & T-STAT) FOR USE A DATA CABLE THERMOSTAT ONLY
ONLY USE (3) 16-22 GUAGE
COOL / FURNACE THROUGH THE WALL THAT 3314082.011 = WHITE
WIRES THROUGH THE WALL.
3316230.700 = WHITE LOOKS LIKE STANDARD 3314082.000 = BLACK
3316230.714 = BLACK TELEPHONE CABLE.
HOWEVER, POLARITY IS CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY 3312020.000
DIFFERENT AND A
3316250.700 = WHITE
STANDARD TELEPHONE RETURN AIR GRILLE (QUICK COOL
3316250.712 = BLACK
CABLE WILL NOT WORK. VENT)
HEAT STRIP CONTROL KIT W/ T-STAT 3317404.000
3316232.700 = WHITE STRAIGHT THROUGH
3316232.710 = BLACK COMMUNICATION CABLE
OPTIONAL HEAT STRIP PART
PART NUMBERS:
RETURN AIR GRILLE (QUICK COOL NUMBER
18 FT. = 3106614.013
VENT) 3315450.000
40 FT. = 3308013.022
3317404.000

OPTIONAL HEAT STRIP PART


NUMBER
3315450.000
(MUST HAVE CORRESPONDING
CONTROL KIT ABOVE)
x x x x x x x NEW MODEL NUMBER
ENDINGS:
XX1C0 = WHITE SHROUD
XX1J0 = BLACK SHROUD

. = Standard
A = Special Top Mount
C = China Built
Family: H = Molex Connector (120VAC)
6 = Penguin K = Rev A Board for CCC II

Type:
4 = Cool Only BTU Capacity:
5 = Heat Pump 0 = Hi Efficiency
2 = 11, 000 BTU
Pre-installed Control Availability: 5 = 13,500 BTU
0 = No pre-installed Control Board 6 = High Capacity (15k equivalent)
1 = Control Board Pre-installed
Control Type:
3 = None
Built in Heat Strip Availability:
4 = Analog
1 = No Heat Strip
5 = CCC
3 = Heat Strip Installed
8 = CCC II
9 = SZLCD / CT
WHAT IS YOUR MODEL NUMBER?

NEW MODEL NUMBER ENDINGS:


CXX1C0 = WHITE SHROUD
600315 ► 640315 - 13,500 BTU CXX1J0 = BLACK SHROUD

IF THE UNIT IS CONTROLLED MANUALLY WITH AN ADB (KNOBS ON THE CEILING BOX) IF THE UNIT IS CONTROLLED WITH A WALL THERMOSTAT

REPLACING A/C OR ADB? ARE YOU REPLACING THE A/C, ADB, CONTROL BOX OR THERMOSTAT?
OPTIONAL HEAT STRIP PART
NUMBER
3314998.000
ORDER: A/C ORDER: ADB ORDER: A/C ORDER: ADB CONTROL BOXES
*ONLY COMPATIBLE WITH
640315 = 13,500 BTU 3314851.000 640315 = 13,500 BTU 3314850.000 & THERMOSTATS
NEWER UNIVERSAL ADB
640316 = HIGH CAPACITY 640316 = HIGH CAPACITY

WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
HEAT STRIP CONTROL KIT W/ T-STAT CONTROL BOX
3316232.700 = WHITE (WITHOUT T-STAT)
3316232.710 = BLACK 3109226.005

120VAC
HOW MANY BTU’S DO YOU WANT?

NEW MODEL NUMBER ENDINGS:


CXX1C0 = WHITE SHROUD
640315 = 13,500 BTU 640316 = HIGH CAPACITY
CXX1J0 = BLACK SHROUD

DO YOU WANT MECHANICAL CONTROLS (KNOBS ON ADB – NO WALL THERMOSTAT)? DO YOU WANT A WALL THERMOSTAT?

FOR MECHANICALLY CONTROLLED INSTALLATIONS FOR WALL THERMOSTAT INSTALLATIONS


OPTIONAL HEAT STRIP
PART NUMBER
3314998.000
ORDER: A/C ORDER: ADB *ONLY COMPATIBLE WITH ORDER: A/C ORDER: ADB CONTROL BOXES
640315 = 13,500 BTU 3314851.000 NEWER UNIVERSAL ADB 640315 = 13,500 BTU 3314850.000 & THERMOSTATS
640316 = HIGH CAPACITY 640316 = HIGH CAPACITY

WHAT THERMOSTAT DO YOU NEED?

C/T NOTE: CCC II (10 BUTTON)


NOTE: MULTI-ZONE INSTALLATIONS
SINGLE ZONE INSTALLATIONS USE A DATA CABLE THERMOSTAT ONLY
CONTROL KIT (BOX & T-STAT) FOR
ONLY USE (3) 16-22 GUAGE THROUGH THE WALL THAT 3314082.011 = WHITE
COOL / FURNACE
WIRES THROUGH THE WALL. LOOKS LIKE STANDARD 3314082.000 = BLACK
3316230.700 = WHITE
3316230.714 = BLACK TELEPHONE CABLE.
HOWEVER, POLARITY IS CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY DIFFERENT AND A 3312020.000
3316250.700 = WHITE STANDARD TELEPHONE
3316250.712 = BLACK CABLE WILL NOT WORK.
HEAT STRIP CONTROL KIT W/ T-STAT
3316232.700 = WHITE STRAIGHT THROUGH
3316232.710 = BLACK COMMUNICATION CABLE
PART NUMBERS:
18 FT. = 3106614.013
40 FT. = 3308013.022
NO HEAT STRIP WHAT IS YOUR MODEL NUMBER?
OPTION AVAILABLE
FOR THIS NEW MODEL NUMBER ENDINGS:
INSTALLATION TYPE CXX1C0 = WHITE SHROUD
600315 ► 640315 – 13,500 BTU CXX1J0 = BLACK SHROUD

ARE YOU REPLACING THE A/C, CONTROL BOX, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL)?

REPLACING A/C CEILING ASSEMBLY (RETURN AIR GRILL) CONTROL KIT, BOX, OR THERMOSTAT

ORDER: A/C ORDER


640315 = 13,500 BTU 3317404.000
640316 = HIGH CAPACITY
WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
FAILS BOTH MUST BE REPLACED.
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
CONTROL BOX
(WITHOUT T-STAT)
3109226.005

120VAC
HOW MANY BTU’S DO YOU WANT?

NEW MODEL NUMBER ENDINGS:


CXX1C0 = WHITE SHROUD
640315 = 13,500 BTU 640316 = HIGH CAPCITY
CXX1J0 = BLACK SHROUD

WHAT THERMOSTAT DO YOU WANT?

NOTE: C/T NOTE: CCC II (10 BUTTON)


SINGLE ZONE INSTALLATIONS MULTI-ZONE INSTALLATIONS
CONTROL KIT (BOX & T-STAT) FOR USE A DATA CABLE THERMOSTAT ONLY
ONLY USE (3) 16-22 GUAGE
COOL / FURNACE THROUGH THE WALL THAT 3314082.011 = WHITE
WIRES THROUGH THE WALL.
3316230.700 = WHITE LOOKS LIKE STANDARD 3314082.000 = BLACK
3316230.714 = BLACK TELEPHONE CABLE.
HOWEVER, POLARITY IS CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY 3312020.000
DIFFERENT AND A
3316250.700 = WHITE
STANDARD TELEPHONE
3316250.712 = BLACK
CABLE WILL NOT WORK. RETURN AIR GRILLE (QUICK COOL
VENT)
RETURN AIR GRILLE (QUICK COOL STRAIGHT THROUGH 3317404.000
VENT) COMMUNICATION CABLE
3317404.000 PART NUMBERS: NO HEAT STRIP OPTION AVAILABLE
18 FT. = 3106614.013 FOR THIS INSTALLATION TYPE
40 FT. = 3308013.022
NO HEAT STRIP OPTION AVAILABLE
FOR THIS INSTALLATION TYPE
NO HEAT STRIP WHAT IS YOUR MODEL NUMBER?
OPTION AVAILABLE
FOR THIS *NEW MODEL NUMER ENDING
INSTALLATION TYPE CXX1C0 = WHITE SHROUD
600312/640312 11K ► 640310 HIGH EFFICIENCY CXX1J0 = BLACK SHROUD

IF THE UNIT IS CONTROLLED MANUALLY WITH AN ADB (KNOBS ON THE CEILING BOX) IF THE UNIT IS CONTROLLED WITH A WALL THERMOSTAT

REPLACING A/C OR ADB? ARE YOU REPLACING THE A/C, ADB, CONTROL BOX OR THERMOSTAT?

ORDER: A/C ORDER: ADB ORDER: A/C ORDER: ADB CONTROL BOXES
640310 3314854.000 640310 3314850.000 & THERMOSTATS

WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC_

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
CONTROL BOX
(WITHOUT T-STAT)
3109226.005

120VAC
NO HEAT STRIP 640310
OPTION AVAILABLE *NEW MODEL NUMER ENDING
FOR THIS CXX1C0 = WHITE SHROUD
INSTALLATION TYPE WHAT TYPE OF INSTALLATION DO YOU WANT? CXX1J0 = BLACK SHROUD

DO YOU WANT MECHANICAL CONTROLS (KNOBS ON ADB – NO WALL THERMOSTAT)? DO YOU WANT A WALL THERMOSTAT?

FOR MECHANICALLY CONTROLLED INSTALLATIONS FOR WALL THERMOSTAT INSTALLATIONS

ORDER: A/C ORDER: ADB ORDER: A/C ORDER: ADB CONTROL BOXES
640310 3314854.000 640310 3314850.000 & THERMOSTATS

WHAT THERMOSTAT DO YOU NEED?

C/T NOTE: CCC II (10 BUTTON)


NOTE: MULTI-ZONE INSTALLATIONS
SINGLE ZONE INSTALLATIONS USE A DATA CABLE THERMOSTAT ONLY
CONTROL KIT (BOX & T-STAT) FOR
ONLY USE (3) 16-22 GUAGE THROUGH THE WALL THAT 3314082.011 = WHITE
COOL / FURNACE
WIRES THROUGH THE WALL. LOOKS LIKE STANDARD 3314082.000 = BLACK
3316230.700 = WHITE
3316230.714 = BLACK TELEPHONE CABLE.
HOWEVER, POLARITY IS CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY DIFFERENT AND A 3312020.000
3316250.700 = WHITE STANDARD TELEPHONE
3316250.712 = BLACK CABLE WILL NOT WORK.

STRAIGHT THROUGH
COMMUNICATION CABLE
PART NUMBERS:
18 FT. = 3106614.013
40 FT. = 3308013.022
NO HEAT STRIP WHAT IS YOUR MODEL NUMBER?
OPTION AVAILABLE
FOR THIS
INSTALLATION TYPE 600312/640312 11K ► 640310 HIGH EFFICIENCY

ARE YOU REPLACING THE A/C, CONTROL BOX, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL)?

REPLACING A/C CEILING ASSEMBLY (RETURN AIR GRILL) CONTROL KIT, BOX, OR THERMOSTAT

ORDER: A/C ORDER


640310 3317404.000

WHAT THERMOSTAT DO YOU HAVE?

ANALOG SINGLE ZONE – C/T CCC (5 BUTTON) CCC II (10 BUTTON) BI-METAL (120VAC – Non-12VDC)

ANALOG CONTROL KITS ARE NLA – CONTROL KIT (BOX & T-STAT) FOR NO LONGER OFFERED AS NEW THERMOSTAT ONLY NO LONGER AVAILABLE – CONVERT
SEE SINGLE ZONE – C/T KITS COOL / FURNACE INSTALLATION. CONTROL BOXES AND 3314082.011 = WHITE SYSTEM TO SPECIAL CT KIT (NEW
(INCLUDE THERMOSTAT AND 3316230.700 = WHITE THERMOSTATS ARE AVAILBLE FOR 3314082.000 = BLACK THERMOSTAT AND CONTROL BOX)
CONTROL BOX). IF EITHER ANALOG 3316230.714 = BLACK REPLACEMENT ONLY. CONTROL KIT: 3316155.000
CONTROL BOX OR THERMOSTAT CONTROL BOX (WITHOUT T-STAT) ONLY AVAILABLE IN WHITE T-STAT
FAILS BOTH MUST BE REPLACED. THERMOSTAT ONLY THERMOSTAT ONLY 3312020.000 *NO HEAT STRIP OPTION AVAILABLE
3316250.700 = WHITE 3109228.001 = WHITE (NLA)
3316250.712 = BLACK 3109228.019 = BLACK
CONTROL BOX
(WITHOUT T-STAT)
3109226.005

120VAC
NO HEAT STRIP
OPTION AVAILABLE * MODEL NUMER ENDING
FOR THIS CXX1C0 = WHITE SHROUD
640310
INSTALLATION TYPE CXX1J0 = BLACK SHROUD

WHAT THERMOSTAT DO YOU WANT?

NOTE: C/T NOTE: CCC II (10 BUTTON)


SINGLE ZONE INSTALLATIONS MULTI-ZONE INSTALLATIONS USE
CONTROL KIT (BOX & T-STAT) FOR A DATA CABLE THROUGH THE THERMOSTAT ONLY
ONLY USE (3) 16-22 GUAGE
COOL / FURNACE WALL THAT LOOKS LIKE 3314082.011 = WHITE
WIRES THROUGH THE WALL.
3316230.700 = WHITE STANDARD TELEPHONE CABLE. 3314082.000 = BLACK
3316230.714 = BLACK HOWEVER, POLARITY IS DIFFERENT
AND A STANDARD TELEPHONE CONTROL BOX (WITHOUT T-STAT)
THERMOSTAT ONLY 3312020.000
CABLE WILL NOT WORK.
3316250.700 = WHITE
3316250.712 = BLACK RETURN AIR GRILLE (QUICK COOL
STRAIGHT THROUGH VENT)
RETURN AIR GRILLE (QUICK COOL COMMUNICATION CABLE PART 3317404.000
VENT) NUMBERS:
3317404.000 18 FT. = 3106614.013
40 FT. = 3308013.022
NO HEAT STRIP
OPTION AVAILABLE
FOR THIS * MODEL NUMER ENDING
INSTALLATION TYPE 650016 = High Performance 15K BTU Equivalent CXX1C0 = WHITE SHROUD
CXX1J0 = BLACK SHROUD

THESE UNITS ARE DESIGNED TO ONLY WORK WITH THE MECHANICAL AIR DISTRIBUTION BOX (ADB)

NOTE: MECHANICAL ADB


THERE ARE A HANDFUL OF 3314853.000
THESE UNITS THAT ARE
CONVERTED TO USE A
THIRD-PARTY WALL
CONTROL SYSTEM. THIS WAS
APPROVED AS AN OEM
INSTALLATION ONLY.
WHAT IS YOUR MODEL NUMBER? NEW MODEL NUMBER ENDINGS:
CXX1C0 = WHITE SHROUD
CXX1J0 = BLACK SHROUD

620315 (see below) /620525/641515/641815 ► 641816 – HIGH CAPACITY 620515/641535 ► 641835 W/ PRE-INSTALLED HEAT STRIP – 13.5K 620526/641516 ► 641816 – HIGH CAPACITY

ARE YOU REPLACING THE A/C, CONTROL BOARD, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL), OR DOING A NEW INSTALLATION?

REPLACING OR NEW INSTALL A/C CEILING ASSEMBLY CONTROL BOARD OR THERMOSTAT

ORDER: A/C
641816 = HIGH CAPCITY (NO HS) ORDER
DUCTED: 3317404.000
*IF DOING A NEW INSTALLATION, ORDER NEW 10 BUTTON CCC2 NON-DUCTED: 3314850.000
WALL THERMOSTAT
3314082.011 = WHITE
WHAT THERMOSTAT DO YOU HAVE?
3314082.000 = BLACK

*IF DEFEECTIVE UNIT BEING REPLACED WAS ORIGINALLY USING A


5 BUTTON CCC WALL THERMOSTAT AND HAS MORE THAN ONE CCC (5 BUTTON) CCC II (10 BUTTON)
A/C BEING CONTROLLED BY THE THERMOSTAT, THE NEW AC
UNIT WILL NEED TO BE CONVERTED BACKWARDS TO THE CCC 5 NO LONGER OFFERED AS NEW THERMOSTAT ONLY
BUTTON WITH CONVERSION KIT 3313107.122 INSTALLATION. CONTROL BOARD 3314082.011 = WHITE
AND THERMOSTATS ARE AVAILBLE 3314082.000 = BLACK
*IF THE UNIT WAS USING A 5 BUTTON AND IS ISOLATED TO ONE FOR REPLACEMENT ONLY.
ZONE / ONE AC, CHANGE THE THERMOSTAT TO A 10 BUTTON CONTROL BOARD (WITHOUT T-STAT)
CCC II THERMOSTAT ONLY 3312022.000
3314082.011 = WHITE 3109228.001 = WHITE (NLA)
3314082.000 = BLACK 3109228.019 = BLACK
CONTROL BOARD
620315 units were pre-installed for the 4 Button CCC. When (WITHOUT T-STAT)
replacing a 620315, if the unit is isolated to a single unit / single 3311557.000
zone, order a CCC2 10 Button thermostat with the new 641816. If
the 620315 is installed in a multi-zone setup, EVERYTHING must NOTE: MULTI-ZONE INSTALLATIONS USE A DATA CABLE THROUGH THE WALL
be converted to the 5 Button. THAT LOOKS LIKE STANDARD TELEPHONE CABLE. HOWEVER, POLARITY IS
DIFFERENT AND A STANDARD TELEPHONE CABLE WILL NOT WORK.
10 Button to 5 Button Conversion = 3313107.122
STRAIGHT THROUGH COMMUNICATION CABLE PART NUMBERS:
4 Button to 5 Button Conversion = 3310009.000
18 FT. = 3106614.013 - 40 FT. = 3308013.022
WHAT IS YOUR MODEL NUMBER?
NO HEAT STRIP
OPTION AVAILABLE
NEW MODEL NUMBER ENDINGS:
FOR THIS
HXX1C0-01 = WHITE SHROUD
INSTALLATION TYPE 630035 (plug-n-play) /630515/651515 = 651815 – 13,500 BTU 630516/651516 = 651816 – HIGH CAPACITY HXX1J0-01 = BLACK SHROUD

ARE YOU REPLACING THE A/C, CONTROL BOARD, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL), OR DOING A NEW INSTALLATION?

REPLACING OR NEW INSTALL A/C CEILING ASSEMBLY CONTROL BOARD OR THERMOSTAT

ORDER: A/C ORDER


651815 = 13,500 BTU DUCTED: 3317404.000
651816 = HIGH CAPCITY NON-DUCTED: 3314850.000

*IF DOING A NEW INSTALLATION, ORDER NEW 10


BUTTON CCC2 WALL THERMOSTAT WHAT THERMOSTAT DO YOU HAVE?
3314082.011 = WHITE
3314082.000 = BLACK
CCC (5 BUTTON) CCC II (10 BUTTON)
*IF UNIT WAS ORIGINALLY USING A 5 BUTTON CCC WALL
THERMOSTAT AND HAS MORE THAN ONE A/C BEING NO LONGER OFFERED AS NEW INSTALLATION. THERMOSTAT ONLY
CONTROLLED BY THE THERMOSTAT, THE NEW AC WILL CONTROL BOARD AND THERMOSTATS ARE 3314082.011 = WHITE
NEED A CONVERSION KIT TO MAKE IT COMPATIBLE WITH AVAILBLE FOR REPLACEMENT ONLY. 3314082.000 = BLACK
THE EXSISTING SYSTEM.
CONVERSION KIT: 3313107.107 THERMOSTAT ONLY CONTROL BOARD (WITHOUT T-STAT)
3109228.001 = WHITE (NLA) 3312022.000
*IF THE UNIT WAS USING A 5 BUTTON AND IS ISOLATED 3109228.019 = BLACK
TO ONE ZONE / ONE AC, CHANGE THE THERMOSTAT TO A
10 BUTTON CCC II CONTROL BOARD
(WITHOUT T-STAT)
3314082.011 = WHITE
3314082.000 = BLACK 3311557.000
FOR 630035 ONLY – IF 4 BUTTON CONTROL BOX
NOTE: MULTI-ZONE INSTALLATIONS USE A DATA CABLE THROUGH THE WALL THAT LOOKS FAILS, REPLACE BOX AND THERMOSTAT WITH 5
LIKE STANDARD TELEPHONE CABLE. HOWEVER, POLARITY IS DIFFERENT AND A STANDARD BUTTON
TELEPHONE CABLE WILL NOT WORK. STRAIGHT THROUGH COMMUNICATION CABLE PART CONTROL BOX = 3109226.005
NUMBERS: 18 FT. = 3106614.013 - 40 FT. = 3308013.022 5 BUTTON THERMOSTAT = 3109228.019
WHAT IS YOUR MODEL NUMBER? NEW MODEL NUMBER ENDINGS:
AXX1C0 = WHITE SHROUD
AXX1J0 = BLACK SHROUD

620415/641415/641915 ► 641916 – HIGH CAPACITY (NO HS) 620415/641435/641935 = NLA & NO DIRECT REPLACEMENT W/ HEAT STRIP 620426/641416 ► 641916 – HIGH CAPACITY (NO HS)

ARE YOU REPLACING THE A/C, CONTROL BOARD, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL), OR DOING A NEW INSTALLATION?

REPLACING OR NEW INSTALL A/C CEILING ASSEMBLY CONTROL BOARD OR THERMOSTAT

ORDER: A/C ORDER


641916 = HIGH CAPCITY (NO HS) DUCTED: 3317404.000
NON-DUCTED: 3314850.000
*IF DOING A NEW INSTALLATION, ORDER NEW CT WALL
THERMOSTAT.
3316250.700 = WHITE WHAT THERMOSTAT DO YOU HAVE?
3316250.712 = BLACK

*IF UNIT WAS ORIGINALLY USING A NON-DIGITAL


ANALOG THERMOSTAT SZLCD / CT (3 BUTTON)
ANALOG WALL THERMOSTAT, CHANGE TO A NEW CT
WALL THERMOSTAT. NEW STAT WILL ONLY USE THREE NO LONGER OFFERED AS NEW THERMOSTAT ONLY
WIRES THROUGH THE WALL. THE LEFT-OVER WIRES WILL INSTALLATION. CONTROL BOARD 3316250.700 = WHITE T-STAT
BE SPARES. AND THERMOSTATS ARE NLA AND 3316250.712 = BLACK T-STAT
3316250.700 = WHITE THE COMPLETE A/C UNIT AND WALL
3316250.712 = BLACK THERMOSTAT WILL NEED CHANGED. CONTROL BOARD (WITHOUT T-STAT)
ORDER A/C: 641916 3313107.076
*IF ORIGINAL UNIT WAS NON-DUCTED, THE CEILING 3316250.700 = WHITE T-STAT
ASSEMBLY WILL ALSO NEED CHANGED. 3316250.712 = BLACK T-STAT
NON-DUCTED ADB: FJXADBNWH *IF UNIT WAS NON-DUCTED, THE
CEILING ASSEMBLY WILL ALSO NEED
CHANGED.
NON-DUCTED ADB: FJXADBNWH
WHAT IS YOUR MODEL NUMBER? NEW MODEL NUMBER ENDINGS:
NO HEAT STRIP HXX1C0-01 = WHITE SHROUD
OPTION AVAILABLE HXX1J0-01 = BLACK SHROUD
FOR THIS 651916 = HIGH CAPACITY
651915 – 13,500 BTU = NLA CHANGE TO 651916 – HIGH CAPACITY
INSTALLATION TYPE

ARE YOU REPLACING THE A/C, CONTROL BOARD, THERMOSTAT, OR CEILING ASSEMBLY (RETURN AIR GRILL), OR DOING A NEW INSTALLATION?

REPLACING OR NEW INSTALL A/C CEILING ASSEMBLY CONTROL BOARD OR THERMOSTAT

ORDER: A/C ORDER


651916 = HIGH CAPCITY DUCTED: 3317404.000
NON-DUCTED: 3314850.000
*IF DOING A NEW INSTALLATION, ORDER NEW CT WALL
THERMOSTAT.
3316250.700 = WHITE WHAT THERMOSTAT DO YOU HAVE?
3316250.712 = BLACK

*IF UNIT WAS ORIGINALLY USING A NON-DIGITAL


ANALOG THERMOSTAT SZLCD / CT (3 BUTTON)
ANALOG WALL THERMOSTAT, CHANGE TO A NEW CT
WALL THERMOSTAT. NEW STAT WILL ONLY USE THREE NO LONGER OFFERED AS NEW THERMOSTAT ONLY
WIRES THROUGH THE WALL. THE LEFT-OVER WIRES WILL INSTALLATION. CONTROL BOARD 3316250.700 = WHITE T-STAT
BE SPARES. AND THERMOSTATS ARE NLA AND 3316250.712 = BLACK T-STAT
3316250.700 = WHITE THE COMPLETE A/C UNIT AND WALL
3316250.712 = BLACK THERMOSTAT WILL NEED CHANGED. CONTROL BOARD (WITHOUT T-STAT)
ORDER A/C: 641916 3313107.077
*IF ORIGINAL UNIT WAS NON-DUCTED, THE CEILING 3316250.700 = WHITE T-STAT
ASSEMBLY WILL ALSO NEED CHANGED. 3316250.712 = BLACK T-STAT
NON-DUCTED ADB: FJXADBNWH *IF UNIT WAS NON-DUCTED, THE
CEILING ASSEMBLY WILL ALSO NEED
CHANGED.
NON-DUCTED ADB: FJXADBNWH
xx x x x x x x NEW MODEL NUMBER
ENDINGS:
XX1C0 = WHITE SHROUD
XX1J0 = BLACK SHROUD

Family: . = Standard
H5 = BLIZZARD A = Special Top Mount

Type:
4 = Cool Only
5 = Heat Pump
BTU Capacity:
5 = 13,500 BTU
Pre-installed Control Availability:
6 = 15,000 BTU
0 = No pre-installed Control Board
1 = Control Board Pre-installed

Control Type: Built in Heat Strip Availability:


3 = None 1 = No Heat Strip
8 = CCC II 3 = Heat Strip Installed
9 = SZLCD / CT
HOW MANY BTU’S DO YOU WANT NEW MODEL NUMBER ENDINGS:
AXX1C0 = WHITE SHROUD
AXX1J0 = BLACK SHROUD
541815 ► H541815 = 13,500 BTU 541816 ► H541816 = 15,000 BTU

REPLACING OR NEW INSTALL A/C CEILING ASSEMBLY CONTROL BOARD OR THERMOSTAT

ORDER: A/C ORDER CCC II (10 BUTTON)


H541815 = 13,500 BTU DUCTED: 3317404.000
H541816 = 15,000 BTU NON-DUCTED: FJXADBNWH THERMOSTAT ONLY
- OR – 3314082.011 = WHITE
NON-DUCTED: 3314850.000 3314082.000 = BLACK
NOTE: MULTI-ZONE INSTALLATIONS USE *NOTE: OFTEN TIMES BLIZZARDS ARE
A DATA CABLE THROUGH THE WALL CONTROL BOARD (WITHOUT T-STAT)
INSTALLED AS TOP-DOWN MOUNT AND
THAT LOOKS LIKE STANDARD TELEPHONE 3312022.000
DO NOT UTILIZE A CEILING ASSEMBLY. IT
CABLE. HOWEVER, POLARITY IS WOULD BE EVIDENT THIS IS THE TYPE OF
DIFFERENT AND A STANDARD INSTALLATION USED IF THERE IS NO
TELEPHONE CABLE WILL NOT WORK. ACCESS TO THE BOTTOM OF THE AC
STRAIGHT THROUGH COMMUNICATION FROM THE INSIDE OF THE RV.
CABLE PART NUMBERS:
18 FT. = 3106614.013
40 FT. = 3308013.022
HOW MANY BTU’S DO YOU WANT NEW MODEL NUMBER ENDINGS:
AXX1C0 = WHITE SHROUD
AXX1J0 = BLACK SHROUD
551815 ► H551815 = 13,500 BTU 551816 ► H551816 = 15,000 BTU

REPLACING OR NEW INSTALL A/C CEILING ASSEMBLY CONTROL BOARD OR THERMOSTAT

ORDER: A/C ORDER CCC II (10 BUTTON)


H551815 = 13,500 BTU DUCTED: 3317404.000
H551816 = 15,000 BTU NON-DUCTED: FJXADBNWH THERMOSTAT ONLY
- OR – 3314082.011 = WHITE
NON-DUCTED: 3314850.000 3314082.000 = BLACK
NOTE: MULTI-ZONE INSTALLATIONS USE *NOTE: OFTEN TIMES BLIZZARDS ARE
A DATA CABLE THROUGH THE WALL CONTROL BOARD (WITHOUT T-STAT)
INSTALLED AS TOP-DOWN MOUNT AND
THAT LOOKS LIKE STANDARD TELEPHONE 3312022.000
DO NOT UTILIZE A CEILING ASSEMBLY. IT
CABLE. HOWEVER, POLARITY IS WOULD BE EVIDENT THIS IS THE TYPE OF
DIFFERENT AND A STANDARD INSTALLATION USED IF THERE IS NO
TELEPHONE CABLE WILL NOT WORK. ACCESS TO THE BOTTOM OF THE AC
STRAIGHT THROUGH COMMUNICATION FROM THE INSIDE OF THE RV.
CABLE PART NUMBERS:
18 FT. = 3106614.013
40 FT. = 3308013.022
HOW MANY BTU’S DO YOU WANT NEW MODEL NUMBER ENDINGS:
AXX1C0 = WHITE SHROUD
AXX1J0 = BLACK SHROUD
541915 ► H541915 = 13,500 BTU 541916 ► H541916 = 15,000 BTU

REPLACING OR NEW INSTALL A/C CEILING ASSEMBLY CONTROL BOARD OR THERMOSTAT

ORDER: A/C ORDER SINGLE ZONE / CT


H541915 = 13,500 BTU DUCTED: 3317404.000
H541916 = 15,000 BTU NON-DUCTED: FJXADBNWH THERMOSTAT ONLY
- OR – 3316250.700 = WHITE T-STAT
NON-DUCTED: 3314850.000 3316250.712 = BLACK T-STAT
*NOTE: OFTEN TIMES BLIZZARDS ARE CONTROL BOARD (WITHOUT T-STAT)
INSTALLED AS TOP-DOWN MOUNT AND
3313107.076
DO NOT UTILIZE A CEILING ASSEMBLY. IT
WOULD BE EVIDENT THIS IS THE TYPE OF
INSTALLATION USED IF THERE IS NO
ACCESS TO THE BOTTOM OF THE AC
FROM THE INSIDE OF THE RV.
HOW MANY BTU’S DO YOU WANT

NEW MODEL NUMBER ENDINGS:


AXX1C0 = WHITE SHROUD (NLA)
551916 ► H551916 = 15,000 BTU AXX1J0 = BLACK SHROUD

REPLACING OR NEW INSTALL A/C CEILING ASSEMBLY CONTROL BOARD OR THERMOSTAT

ORDER: A/C ORDER SINGLE ZONE / CT


H551916 = 15,000 BTU DUCTED: 3317404.000
NON-DUCTED: FJXADBNWH THERMOSTAT ONLY
- OR – 3316250.700 = WHITE T-STAT
NON-DUCTED: 3314850.000 3316250.712 = BLACK T-STAT
*NOTE: OFTEN TIMES BLIZZARDS ARE CONTROL BOARD (WITHOUT T-STAT)
INSTALLED AS TOP-DOWN MOUNT AND
3313107.077
DO NOT UTILIZE A CEILING ASSEMBLY. IT
WOULD BE EVIDENT THIS IS THE TYPE OF
INSTALLATION USED IF THERE IS NO
ACCESS TO THE BOTTOM OF THE AC
FROM THE INSIDE OF THE RV.
WHAT IS YOUR MODEL NUMBER?

41001/441001 ► 441003AXX1

REPLACING OR NEW INSTALLATION CONTROL BOARD OR THERMOSTAT REPLACEMENT

A/C WHICH CONTROL SYSTEM DO YOU CURRENTLY HAVE

ORDER: A/C ANALOG SINGLE ZONE / CT


441003AXX1
ANALOG CONTROL BOARD AND THERMOSTAT ONLY
*NOTE THERMOSTAT ARE NLA – IF EITHER FAILS THE 3316250.700 = WHITE T-STAT
IF REPLACING AN OLDER SYSTEM THAT USED THE ANOLOG COMPLETE SYSTEM WILL NEED REPLACED 3316250.712 = BLACK T-STAT
THERMOSTAT, THE WAL THERMOSTAT MUST BE REPLACED AS WELL. (WALL THERMOSTAT AND A/C UNIT)
CONTROL BOARD (WITHOUT T-STAT)
3316250.700 = WHITE T-STAT
3313107.077
3316250.712 = BLACK T-STAT
*USE THE ABOVE THERMOSTATS FOR A NEW INSTALLATION AS WELL

NOTE: Depending on the original installation and setup from the RV


manufacturer, an Installation kit might be needed. Sometimes this was
custom made by the RV OEM.
INSTALLATION KITS:
Black CT Stat & Black Exterior Vent = 3314087.036
Black CT Stat & Black Exterior Vent (NO Deflector) = 3314087.135
White CT Stat, Beige Exterior Vent = 3314087.069
Black Forest River Specific Kit (NO Exterior Vent) = 3314087.101
HARDWARE KIT = 3107662.003 (Hold-down clamps, screws, drain fitting,
and sealant)