0% found this document useful (0 votes)
94 views2 pages

High-Precision KERN CFS Counting Scales

Uploaded by

Manuel Moutinho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
94 views2 pages

High-Precision KERN CFS Counting Scales

Uploaded by

Manuel Moutinho
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Counting scale KERN CFS

A C

Professional, high-resolution counting scale with 100 item


memories and second balance interface, counting resolution
up to 75,000 points
Features · Second balance interface to construct a Accessories
09 · Memory (PLU) for 100 items with additional
high-resolution counting system, standard,
· Protective working cover, scope
e.g. with weighing bridges KERN
text, reference weight and tare weight, e.g. of delivery: 5 items, for models
· Protective working cover included with
of a container with weighing plate size A, B,
delivery, for models with weighing plate size
· Precise counting: The automatic reference KERN CFS-A02S05
A, B
weight optimisation of reference weight gradu- · Rechargeable battery pack internal,
ally improves the average piece weight value operating time up to 70 h without
Technical data
· Programmable using numerical key pad: backlight, charging time approx. 14 h,
- required reference quantity · Large backlit LCD displays, digit height 20 mm KERN GAB-A04
- known reference weight · Dimensions weighing surface · Signal lamp for visual support of
· Three displays for weight display (verifiable), A ∅ 80 mm weighing with tolerance range,
reference weight, total pieces B W×D 300×225 mm, see larger picture KERN CFS-A03
· Weighing with tolerance range (check- C W×D 365×240 mm · Y-cable for parallel connection of two terminal
weighing): a visual and audible signal helps · Overall dimensions W×D×H devices to the RS-232 interface on the scale,
with portioning, dispensing or grading A 320×350×180 mm (incl. draught shield) e.g. signal lamp or barcode reader and
· Audible Fill-to-target: target quantity B 320×350×125 mm printer, KERN CFS-A04
or target weight can be programmed, C 365×240×125 mm · WLAN interface for wireless connection of
e. g. for checkweighing. When the target · Permissible ambient temperature the balance to networks and WLAN capable
value is reached, a signal will sound 0 °C/40 °C devices, such as tablets, laptops or smart-
· PRE-TARE function for manual subtraction phones, must be ordered at purchase,
of a known container weight, useful for KERN CFS-A05
checking fill-levels · Further details, plenty of further accessories
and suitable printers see Accessories
KERN Balances & Test services catalogue 2018

STANDARD OPTION FACTORY

MULTI

Model Weighing range Readout Smallest part Counting Net weight Weighing plate Options
weight resolution DAkkS Calibr. Certificate
[Max] [d] [Normal] approx.
KERN kg g g/piece Points kg KERN
CFS 300-3 0,3 0,001 0,05 60.000 2,6 A 963-127
CFS 3K-5 3 0,01 0,5 60.000 3,4 B 963-127
CFS 6K0.1 6 0,1 1 60.000 3,4 B 963-128
CFS 15K0.2 15 0,2 2 75.000 3,4 B 963-128
CFS 30K0.5 30 0,5 5 60.000 3,4 B 963-128
CFS 50K-3 50 1 10 50.000 4,4 C 963-128

76 Counting scales/Counting systems [Link]


Order Hotline:
· OrderGo
hotline
to back [0] 7433
+49page of catalogue
KERN & SOHN GmbH • Ziegelei 1 • 72336 Balingen • Germany • Tel. + 49-[0]7433-9933-0 • Fax + 49-[0]7433-9933-149 • [Link]• info@[Link]
9933 - 0
KERN Pictograms
Internal adjusting: Quick setting up of the GLP/ISO log: The balance displays serial Suspended weighing: Load support with
balance‘s accuracy with internal adjusting number, user ID, weight, date and time, hook on the underside of the balance
weight (motor­driven) regardless of a printer connection

Adjusting program CAL: For quick setting GLP/ISO log: With weight, date and time. Battery operation: Ready for battery
up of the balance‘s accuracy. External Only with KERN printers operation. The battery type is specified
adjusting weight required for each device

Memory: Balance memory capacity, e.g. Piece counting: Reference quantities Rechargeable battery pack:
for article data, weighing data, tare weights, selectable. Display can be switched from Rechargeable set
PLU etc. piece to weight

Alibi memory: Secure, electronic archiving Recipe level A: The weights of the recipe Universal mains adapter: with universal input
of weighing results, complying with the ingredients ­can ­be added together and the and optional input socket adapters for
ALIBI 2014/31/EU standard. total weight of the recipe can be printed out MULTI A) EU, GB
B) EU, GB, CH, USA
C) EU, GB, CH, USA, AUS

Data interface RS-232: To connect the Recipe level B: Internal memory for com- Mains adapter: 230V/50Hz in standard
balance to a printer, PC or network plete recipes with name and target value version for EU. On request GB, USA or AUS
of the recipe ingredients. User guidance version available
through display
RS-485 data interface: To connect the Recipe level C: Internal memory for com- Power supply: Integrated in balance.
balance to a printer, PC or other peripherals. plete recipes with name and target value 230V/50Hz standard EU. More standards
Suitable for data transfer over large distances. of the recipe ingredients. User guidance e.g. GB, USA or AUS on request
Network in bus topology is possible through display, multiplier function, adjust-
ment of recipe when dosages are exceeded
or barcode recognition
USB data interface: To connect the balance Totalising level A: The weights of similar Weighing principle: Strain gauges Electrical
to a printer, PC or other peripherals items can ­be added together and the total resistor on an elastic deforming body
can be printed out

Bluetooth* data interface: To transfer data Percentage determination: Determining Weighing principle: Tuning fork A resonating
from the balance to a printer, PC or other the deviation in % from the target value (100 %) body is electromagnetically excited, causing it
peripherals to oscillate

WLAN data interface: To transfer data Weighing units: Can be switched to e.g. Weighing principle: Electromagnetic force
from the balance to a printer, PC or other nonmetric units at the touch of a key. See compensation Coil inside a permanent
peripherals balance model. Please refer to KERN‘s magnet. For the most accurate weighings
website for more details
Control outputs (optocoupler, digital I/O): Weighing with tolerance range: (Check- Weighing principle: Single cell technology
To connect relays, signal lamps, valves, etc. weighing) Upper and lower limiting can be Advanced version of the force compensation
programmed individually, e.g. for sorting principle with the highest level of precision
and dosing. The process is supported by
Interface for second balance: For direct an audible or visual signal, see the relevant Verification possible: The time required for
connection of a second balance model verification is specified in the pictogram

Network interface: For connecting the Hold function: (Animal weighing program) DAkkS calibration possible (DKD): The time
scale to an Ethernet network When the weighing conditions are un­stable, a required for DAkkS calibration is shown in
stable weight is calculated as an average value days in the pictogram

Wireless data transfer: between the Protection against dust and water Package shipment: The time required for
weighing unit and the evaluation unit using splashes IPxx: The type of protection is internal shipping preparations is shown in
an integrated radio module shown in the pictogram. days in the pictogram

KERN Communication Protocol (KCP): It Stainless steel: The balance is protected Pallet shipment: The time required for inter-
is a standardized interface command set for against corrosion nal shipping preparations is shown in days
KERN balances and other instru­ments, which in the pictogram
allows retrieving and controlling all relevant
parameters and functions of the device. KERN
devices featuring KCP are thus easily integra-
ted with computers, industrial controllers and
other digital systems

KERN – Precision is our business Your KERN specialist dealer:


To ensure the high precision of your balance KERN offers you the the appropriate
test weight in the international OIML error limit classes E1-M3 from 1 mg - 2500 kg.
In combination with a DAkkS calibration certificate the best pre-requisite for
proper balance calibration.

The KERN DAkkS calibration laboratory today is one of the most modern and
best-equipped DAkkS calibration laboratories for balances, test weights and force-
measurement in Europe.
Thanks to the high level of automation, we can carry out DAkkS calibration of
balances, test weights and force-measuring devices 24 hours a day, 7 days a week.

Range of services:
• DAkkS calibration of balances with a maximum load of up to 50 t
• DAkkS calibration of weights in the range of 1 mg – 2500 kg
• Volume determination and measuring of magnetic susceptibility (magnetic
characteristics) for test weights
• Database supported management of checking equipment and reminder service
• Calibration of force-measuring devices
• DAkkS calibration certificates in the following languages DE, GB, FR, IT, ES, NL, PL *The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by
• Conformity evaluation and reverification of balances and test weights KERN & SOHN GmbH is under license. Other trademarks and trade names are those of their respective owners.

You might also like