Electric Garage Door Opener Manual
Electric Garage Door Opener Manual
USER MANUAL
INDEX
1. Warnings 2
2. Product description 3
2.1 Applications 3
2.2 Description of the automation 3
3. Installation 4
3.1 Inventory of a garage door opener 4
3.2 Rail assembly 5
3.3 Attach the rail to the motor 6
3.4 Attach the rail on the header wall and ceiling 6
3.5 Connect release section to the garage door 7
3.6 Final steps before system learning 8
3.7 Introduction of the emergency release 8
4. Operation 9
4.1 Accessory connection 9
4.2 Door position for start-up phase 9
4.3 Transmitter memorizing and erasing process 10
4.4 System learning, reset process, and LED display 10
4.5 Programmable function indication LED 12
4.6 How to set the parameter 12
4.7 Programmable function setting 13
5. Function of terminals 14
5.1 Photocells 14
5.2 Installation of Photocells 14
6. Specification 15
7. Wi-Fi Box User Manual 16
8. Accessory 17
1. WARNINGS
WARNING :
Please read this instruction manual carefully before the installation.
This manual is exclusively for qualified installation personnel. TMT Automation Inc. is not responsible for
improper installation and failure to comply with local electrical and building regulations.
Keep all the components for the garage door opener and this manual in hand for further consultation.
● In this manual, please pay extra attention to the contents marked by the symbol:
● Be aware of the hazards that may exist in the procedures of installation and operation of the garage door opener.
Besides, the installation must be carried out inconformity with local standards and regulations.
● If the system is correctly installed and followed all the regulations, it will ensure a high degree of security.
● Make sure that the door works properly before installing the garage door opener and confirm the doors are
appropriate for the application.
● Do not let children operate or play with the garage door opener.
● Do not cross the path of the garage door opener when it is in operation.
● Please keep all the control devices and any other pulse generator away from children to avoid the system being
activated accidentally.
● Do not make any modifications to any components except that it is mentioned in this manual.
● Do not try to manually open or close the doors before you release the opener.
● If there is a failure that cannot be solved and is not mentioned in this manual, please contact a professional installer.
● Do not use the garage door opener before all the procedures and instructions have been carried out and
thoroughly read.
● Install warning signs (if necessary) on the both sides of the door to warn the people in the area of potential hazards.
2.1 APPLICATIONS
Garage door opener is applied for residential automation of up and over doors and sectional doors. It has to be operat-
ed with electricity. It’s forbidden to be operated by back-up batteries for normal [Link]-up batteries are only allowed
for emergent operation when there is a power failure, and the carriage can be released by pulling the cord to move the
door manually.
4
1
3
1 Garage Door Opener
5
2 Photocells (Optional accessories)
3 Flashing Light (Optional accessories)
2 2 4 Key selector (Optional accessories)
6
5 Push Button (Optional accessories)
6 Transmitter
1 2 3 4 5 6 7
C Rail Front hold Rear Pulley Support Front Pulley Release Rope
Tensioner
8 9 10 11 12 13 14 15
16
Hardware Inventory
17
18 19 20 21 22
Blocker x1 Locking x2 Screws x4 M8*20 M6*14
Optional for 1pcs x 1M Rail Plate HEX bolt x4 HEX bolt x4
23 24 25
Junction x2 Clevis Pin x2 M8*8 Nut x4 M6*6 Nut x8 27 Cotter Pin
1. The (6) Inner trolly assy and the (5) Chain and index are already in the Rail. 18
3 2. Make sure the metal index is on right side of the rail. 8
3. Fasten the (8) Outer trolly assy on the (6) Inner trolly assy with (18) Screws 4pcs
6 5
Inner trolly assy Chain and index
4
Remove the nut and the spring in the (4) Front pulley tensioner. Make sure the metal chain is placed in the gap of the
pulley on the two sides. Insert the (2) Front hold bracket against the rail. Use the spring and the nut to adjust the
tightness of the (5) Chain.
2
Completion
4
5
Note: Remember to lubricate the front and rear pulley before use.
1 2 3
25 Nut
13
Ceiling
bracket
9 Motor
hold bracket
10 Ceiling 24
hold bracket Nut
CAUTION
(11)
Header Bracket To prevent damage, place the garage door on the top
(11) section to create a temporary support.
Header
Bracket
Long Clevis
Pin
Garage
Door
1
Connect the (7) Emergency release rope on the
(8) Outer trolley assy
WARNING
To prevent possible SERIOUS INJURY or DEATH from a falling
ENGAGED Secure handle with overhand knot garage door:
and heat seal rope.
• If possible, use emergency release handle to disengage trolley ONLY
when garage door is CLOSED. Weak or broken springs or
unbalanced door could result in an open door falling rapidly and/or
unexpectedly.
Rope • NEVER use emergency release handle unless garage doorway is
RELEASED
7 Emergency clear of persons and obstructions.
Release Handle Overhand • NEVER use handle to pull door open or closed. If rope knot
Knot becomes untied, you could fall.
2 Pull the (7) Release rope to disengage the 3 Connect (15) Straight door arm to Release trolley
(8) trolley
Pull Down
to Release
23
Trolley Clevis Pin
19
Locking Plate
15
Straight
Arm
Fasten the (12) Door bracket and (16) Door bracket locator Connect the (14) Curved arm and
4 on the center of the garage door. Connect (14) Curved arm 5 the (15) straight arm with bolts and nuts.
to (12) Door bracket.
(12)+(16)
15
Straight
Arm
19
Locking Plate
23
Clevis Pin 21
(not included in the hardware inventory)
24
Hex Bolt Nut
Connect Curved
Arm to Door Bracket
14
Curved
Door bracket locator Arm
is used when door
panel is required
1 2 3 WARNING
18
Blocker
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:
• Ensure power is not connected to the opener, and
disconnect power from the circuit BEFORE removing
cover to establish permanent wiring connection.
RED • Garage door installation and wiring ARE in
RELEASE
CORO compliance with all local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter, or
RED EMERGENCY
RELEASE KNOB
change plug in ANY way to make it fit an outlet.
Ensure the opener is grounded.
Pull Down
to Release
Trolley
Only establish electrical connections when the electricity supply to the system is OFF.
A. Open the cover in order to access the electronic connection terminal of the garage gate opener.
RX1
1 2 3 5 6
External Device Flashing Light Push Button Photocell Battery
2. Never cut or remove the cable supplied with the Marble Series garage opener. The power socket of Marble garage opener
connection must be fitted by skilled and qualified personnel in strict observance of current legislation,
standards and regulations.
3. The power supply line must be protected from short circuits and ground leakage.
A B
Within 10 sec
3 SEC
10 SEC
A B A B
Memorized
Within 10 sec
Transmitter
Step.1 Step.2
Step.3 Step.4
Step.5
Default Setting
3 SEC
During the system learning process, the control panel will automatically detect the
current consumption from each motor, indicate the resistance level of the gate
whiling the motor operation. If this reading increase instantly or stay in high
reading, please DO check if any object is in between the gate moving area, and
contact your installer for further inspection.
3 SEC
Confirm
Confirm
2-1 A Key
2-2 B Key
2-3 C Key
2-4 D Key
3 3-0 Function off [Link] default setting is "3-2"
4-1 A Key
4-2 B Key
4-3 C Key
4-4 D Key
5 Photocell Function Mode 5-0 Function off [Link] default setting is "5-0 "
5-2 Mode 2
6-2 Function on 2. IF the door left opened for longer than 10mins then buzzer
start beeping and turn off until the door been closed.
7-2 30 sec
7-3 60 sec
7-4 90 sec
7-5 120 sec
7-6 150 sec
7-7 180 sec
7-8 210 sec
7-9 240 sec
8 Lighting 8-1 Function off [Link] default setting is "8-4"
5.1 Photocells
F5-1 Mode 1
Gate Status The reactions of the photocells when obstacles are detected
Closed No effect
Opened 1. Stop till next command is given
2. Stop and reload the auto-closing time if the auto-closing feature is on
Stop during moving 1. Stop till next command is given
2. Stop and reload the auto-closing time if the auto-closing feature is on
Closing Stop till next command is given
Opening Stop till next command is given
F5-2 Mode 2
Gate Status The reactions of the photocells when obstacles are detected
Closed No effect
Opened 1. Stop till next command is given
2. Stop and reload the auto-closing time if the auto-closing feature is on
Stop during moving 1. Not allow to close till next command is given
2. Not allow to close and reload the auto-closing time if the auto-closing feature is on
Closing Stop till next command is given
Opening No effect
The safety photocells are security devices to control automatic gates. It’s consist of one transmitter and one
receiver set in the waterproof covers. It will be triggered when the path of the beam is blocked.
SPECIFICATION:
Detection Method Through Beam
Sensing Range MAX~15m
Input Voltage AC/DC 12~24V
Contact Current TX: 30mA Max , RX: 25 mA Max
Response Time <100mS
Emitting Element Infrared LED/ Wave Length 940nm
Operation Indicator RXRed LED On (beam broken) / Off (beam aligned)
TXRed LED On
Dimensions 63*63*30 mm
Output Method Relay Output
Current Consumption Beam aligned RX<25ma\TX<30ma
Beam broken RX <10ma\TX <30ma
Connection Method Terminal Block
Housing Material ABS / PC
Water Proof IP54
Safety Standard CE
RX TX
Power LED
Indicator
Lens
EXT-
LIT- EXT+
LIT+ PB GND PH +24V GND +BATT
Terminal Block
+ - NO NC COM + -
1 2 3 4 5
Power 1 2
Terminal Block
INSTALLATION:
1. Open the cover and connect the wires.
2. Mount the receiver and transmitter on the proper position.
3. Ensure there are no obstacles between receiver and transmitter.
For optimal efficiency, the receiver and transmitter should be properly aligned.
4. Power-up the photocells and make sure the LED light on receiver and transmitter are ON.
Marble
User Manual
[Link]/marble_manual_en
TM3 Transmitter
Frequency 433.92Mhz
Coding Rolling code
Buttons 4 buttons
Power Supply 3V with one CR2032 button type lithium battery
Operating Temperature -20°C~+50°C
Dimension 37*67.5*12 (mm)
H2 Photocells
Detection type Through beam
Operating distance MAX~15 meters
Response time <100mS
Input voltage AC/DC 12-24V
Operating Temperature -20°C~+50°C
Protection level IP54
Dimension 63*63*30 (mm)
K1 Key Selector
Operating Temperature -20°C~+50°C
Dimension 73.2*73.2*42.3 (mm)
P1 Keypad
Frequency 433.92Mhz
Coding Rolling code
Power Supply 12 ~ 24V DC/AC
Operating Temperature -20°C~+50°C
Dimension 106*53*20 (mm)