OVAL GEAR METER

► TECHNICAL SPECIFICATION
Size 10A – 200A
Material Cast iron, Cast steel, Stainless steel

Flange type – JIS 10K RF (Standard)


Connection
ANSI, DIN (Option)

Accuracy ±0.5% of rate / ±0.2% (Option)


Fluid Temperature -20℃ ~ +100℃/ 200℃(Option)

► FLOW RANGE
3
Flow Range(m /h)
Size Petroleum Products Chemical liquids
0.8~2(mPa·s) 2~8(mPa·s) 8~200(mPa·s) 0.8~200(mPa·s)

10A 0.08-0.4 0.04-0.4 0.08-0.4


15 A 0.3-1.5 0.15-1.5 0.3-1.5
20 A 1-3 0.4-3 0.3-3 0.6-3
25 A 2-6 0.8-6 0.6-6 1.2-6
40 A 5-15 2-15 1.5-15 2.4-12
50 A 8-24 3-24 2.4-24 3.8-19
65 A 15-40 5-40 4-40 8-30
80 A 20-60 6-60 6-60
100 A 34-100 10-100 10-100
150 A 64-190 19-190 19-190
200 A 114-340 34-340 34-340

Note: 1. The flow meter should be selected in accordance with the flow range, but not in accordance with the pipe
diameter;
2. If the temperature of the measured liquid is between 100-200℃( the max), the flow rate must subtract by
10%;
3. While the measured liquid is not petroleum product, if its viscosity is equivalent to that listed in the table,
the flow range is also equivalent to that listed above;
4. For chemical, high temperature and high viscosity liquid, please consult the factory;
5. While the measured media is of strong corrosive, the max flow rate must reduce by 1/3.
► DIMENSION

● Dimension for Cast iron Oval meter

DN(mm) L(mm) H(mm) B(mm) A(mm) D(mm) D1(mm) n-ф(mm) Weight(kg)


10 150 100 213 168 90 65 4-15 6
15 170 118 226 178 95 70 4-15 8
20 200 150 238 185 100 75 4-15 11
25 260 180 246 186 125 90 4-19 18
40 245 180 271 194 140 105 4-19 20
50 340 250 379 291 155 120 4-19 46
65 420 325 441 323 175 140 4-19 87
80 420 325 441 323 185 150 8-19 87
100 515 418 467 336 210 175 8-19 160
150 540 515 565 355 280 240 8-23 245
200 650 650 624 377 330 290 12-23 400

● Dimension for Cast steel Oval meter


DN(mm) L(mm) H(mm) B(mm) A(mm) D(mm) D1(mm) n-ф(mm) Weight(kg)

15 200 138 220 167 95 70 4-15 12


20 250 164 245 182 100 75 4-15 18
25 300 202 255 187 125 90 4-19 22
40 300 202 285 202 140 105 4-19 27
50 384 262 400 312 155 120 4-19 66
80 450 337 460 342 185 150 8-19 118
100 555 442 485 354 210 175 8-19 210
150 540 515 565 355 280 240 8-23 260
200 650 650 625 378 330 290 12-23 430

※ Supplied as JIS 10K standard (OEM offered with other standard).


※ For insulating jacket type, Column A,B will add 300mm on data in the above table.
► Stainless steel Oval meter

Media Corrosive fluid


B SS304
Material
C SS316
Accuracy ±0.5%
Fluid Temperature -20℃ ~ +80℃

● Flow Range
3
Flow Range(m /h)
Size 0.8~2 2~8 8~200 200~1000 1000~2000
(mPa·s) (mPa·s) (mPa·s) (mPa·s) (mPa·s)

10A 0.25-0.75 0.15-0.75 0.13-0.75 0.06-0.6 0.03-0.3


15 A 0.5-1.5 0.3-1.5 0.25-1.5 0.1-1 0.075-0.75
20 A 1-3 0.6-3 0.5-3 0.2-2 0.15-1.5
25 A 2-6 1.2-6 1-6 0.4-4 0.3-3
40 A
2.5-20 2-20 2-20 2-20 1-10
50 A
65 A 5-40 4-40 4-40 2.8-28 2-20
80 A 12-60 8-60 6-60 4.5-45 3-30
100 A 34-100 20-100 16-100 14-70 5-50
150 A 64-190 38-190 32-190 28-135 9.5-95
200 A 114-340 68-340 56-340 48-238 17-170

● Dimension for Stainless Steel Oval meter


DN(mm) L(mm) H(mm) B(mm) A(mm) D(mm) D1(mm) n-ф(mm) Weight(kg)
10 170 100 216 171 90 60 4-14 7
15 200 120 226 178 95 65 4-14 11
20 230 150 238 180 105 75 4-14 17
25 280 195 249 185 115 85 4-14 21
40 265 178 370 278 150 110 4-18 24
50 265 178 370 278 165 125 4-18 24
65 365 265 460 335 180 145 4-18 60
80 420 305 459 326 200 160 8-18 82
100 515 400 554 373 220 180 8-18 127
150 540 515 607 397 280 240 8-23 280
200 650 650 646 399 340 295 12-23 435

※ Supplied as our basic model (OEM offered with other standard).


■ LC-T type for Oval Gear Meter with High Temperature
● Material: Cast iron, Cast steel, Stainless steel
● Temperature: + 100℃~+200℃
LC-TA Cast iron LC-TE Cast steel
Pressure (MPa) 1.6 6.4
Temperature (℃) +100~+200
Accuracy 0.5
3 DN10-25 High Temperature
Flow range: m /h
Model DN(mm) 0.8~2 mPa·s 2~8 mPa·s 8~200 mPa·s
LC-T15 15 0.45~1.35 0.36~1.35 0.18~1.35
LC-T20 20 0.9~2.7 0.48~2.7 0.36~2.7
LC-T25 25 1.8~5.4 0.96~5.4 0.72~5.4
LC-T40 40 3.6~13.5 2.4~13.5 1.8~13.5
LC-T50 50 5.8~21.6 3.6~21.6 2.9~21.6
LC-T65 65 9.6~36 6~36 4.8~36
LC-T80 80 15~54 9.6~54 7.2~54
LC-T100 100 24~90 22~90 12~90

DN40-200 High Temperature

DN10-25 High Temperature DN40-200 High Temperature

● Dimension for Cast iron Oval meter (Column B is for type with A6 Reset)
DN(mm) L(mm) H(mm) B(mm) A(mm) D(mm) D1(mm) n-ф(mm) Weight(kg)
10 150 100 213 165 90 65 4-15 6
15 170 118 226 175 95 70 4-15 8
20 200 150 238 180 100 75 4-15 11
25 260 180 246 194 125 90 4-19 18
40 245 180 271 200 140 105 4-19 20
50 340 250 379 285 155 120 4-19 46
80 420 325 441 360 185 150 8-19 87
100 515 418 467 380 210 175 8-19 160
150 540 510 565 400 280 240 8-23 245

200 650 650 624 476 330 290 12-23 400

※ For high temperature type, please add 310mm for column A&B on data in the above table.
■ LC-N type Oval Gear Meter with High Viscosity
● Material: Cast iron, Cast steel, Stainless steel
● Pressure: Cast iron: 1.6MPa;Cast steel: 6.3 MPa (size≤100mm), 2.5 MPa (size>100mm);
Stainless steel: 1.6 MPa, 2.5 MPa
● Viscosity: 200 mPa·s ~2000 mPa·s
● Temperature: -10℃~+100℃

mPa·s
Model DN(mm)
200~2000
LC-N10 10 0.02~0.2
LC-N15 15 0.075~0.75
LC-N 20 20 0.15~1.5
LC-N 25 25 0.3~3
LC-N 40 40 0.75~7.5
LC-N 50 50 1.2~12
LC-N65 65 2~20
LC-N80 80 3~30
LC-N100 100 5~50
LC-N150 150 9.5~95

LC-N200 200 17~170

■ LC-U type Oval Gear Meter with Insulating Jacket

In order to assure normal transfer and measurement of the media, which is easy
to freeze DN10-25 High
under normal Temperature
temperature DN40-200
or easy to condense High Temperature
or crystallize under a degree
temperature, we usually need to heat the media in the pipeline so as to keep the
media melting and insulating at a degree. As direct steam is not permitted to avoid
damage to the oval gear meter, we got this Insulating Jacket type Oval Gear Meter,
that is, add a jacket outside the flow meter body, so we can use hot water, hot oil or
steam less than 200℃ to go through the insulating jacket and then make the media
in the flow meter or strainer melted and kept at a degree, in this way to keep the flow
meter work normally. The strainer in front of the oval gear meter can also adopted
insulating jacket type. The pressure of the jacket is 0.5MPa

● Material: Cast steel, Stainless steel


● Temperature: -20℃~+100℃, +100℃~+200℃
● Size: DN15~DN200
■ LC-ELZ Intelligent Digital Oval Gear Meter

ELZ type LCD counter combined with oval gear meter composes intelligent digital oval gear meter. This counter
adopts new single chip and advanced integrated circuit, which is low power consumption and high accuracy. In addition
to showing totalizer flow, instantaneous flow, it can also output pulse, 4-20mA signal, 485 or 232 communication signal,
which can satisfy modern flow measurement and control demand well.

● Environment Temperature: -10℃~+55℃


● Accuracy: 0.5/0.2
● Size: DN10~DN200

■ LC-13 type Oval Gear Meter

LC-13 type Oval gear meter is composed of body and transmitter, which can transfer the fluid in the pipeline to
Pulse signal or Analog signal output. It can be used together with our display instrument or secondary instrument to
measure and indicate in remote style and adjust record automatically

● Technical Performance

1. Permissible Tolerance(%): ±0.2, ±0.5


2. Viscosity(Mpa·s): ±0.6-200
3. Temperature(℃): -10℃~50℃
4. Max. Working Pressure (MPa): Cast iron: 1.6MPa;
Cast steel: 6.3 MPa (size≤100mm), 2.5 MPa (size>100mm)
5. Main Material: Cast iron, Cast steel, Stainless steel
6. Transmitter: GF type & QF type Pulse Transmitter, MF-Ⅰ
type Analog Transmitter
7. Size: DN10~DN200
LC-W Series Micro-Flow Meter

■ Summary
LC-W Series Micro-Flow meter is a new kind of volumetric flow meter, which is designed according to
the market and has absorbed foreign most advanced technology. It enjoys advantages of micro flow rate,
simple construction, high accuracy, easy operation, and l ong life. It can adapt to the viscosity of the
measured liquid very well and has no requirements on the state and pressure of the measured liquid, so it
can measure even if it flows automatically. The display can indicate total, local, flow rate and has functions
of r eset, s ite di splay and r emote t ransfer, w hich i s es pecially s uitable f or t he ac curate m easurement of
micro flow of motor fuel, bunker fuel, medicine, industrial chemicals, liquor, milk, vegetable oil, etc.

■ Working Principle
LC-W Series Micro-Flow meter is composed of two parts: flow transducer and display. There is one pair

of oval gear in the measurement chamber of transducer, which is taken as measurement unit together with

the chamber. The micro-differential pressure between inlet and outlet makes the gear moving and transfers

the inlet liquid to the outlet constantly after the measurement in chamber (Refer to the following pictures).

At the same time the sensor generates signals accordingly and t ransfers signals to the di splay, and then

the display indicates the flow rate and total rate after analysis.

■ Features
1. Small, light, micro flow rate, high accuracy, long life
2. The body is of stainless steel, which can satisfy all kinds of liquid
3. It em ploys t hree-wire system (positive pow er w ire, s ignal w ire an d p ower ear th-grounded w ire); no
contact; reliable signal; long-distance transfer; square wave output; allowable working voltage DC12V
or 24V.
LC-W Series Micro-Flow Meter

■ Technical Data
1. Output signal: Square wave pulse. When DC12V, high level>9V, low level<1V; When
DC24V, high level>20V, low level<1V;
4-20mA analog signals (Together with Electric liquid counter)
2. Signal frequency is proportional to its flow rate
3. Transmitting distance:1Km
4. Ambient temperature: -10~+65℃
5. Pressure: flow automatically, 0.3, 1.0, 2.0MPa
6. Pulse equivalent: 0.0009L/P, 0.0017L/P (In accordance with practical situation)

If there is any special requirement, please specify separately.

■ Materials
Shell: Stainless steel

Rotor: Copper, Stainless steel

■ Flow Range
Basic type: 55* 55mm M ax. Flow 200L/h
Connection: Screwed G1/4
Pulse output, 3-wire system, without display

Site reading: 70*70mm M ax. Flow 400L/h


Connection: Screwed G1/2
LED display

■ Installation
● All the pipeline should be clean and install strainer before the meter
● Connect with joint or install as to users’ requirements
● In order to repair, by-pass pi peline should be i nstalled and valves should be at tached both f ront and
back of the meter
LC-W Series Micro-Flow Meter

■ Identification

Dia. P
Model — Type Display ∕ Material Connection Explanations
mm MPa
L C Oval gear meter
— —
W Micro type
8 Diameter 8 mm
10 Diameter 10mm
1.0 Pressure 1.0 MPa
Remote display
Y
(With display)
Site display
X
(Output 4-20mA)
∕ /
B Shell, Rotor: SS
Shell: SS;
C
Rotor: Copper
G Screw Connection

J Joint Connection

Site Display Type