Orifice Flow Calculation
Calculating an Orifice Diameter
It is difficult to accurately calculate the flow of a gas or liquid through a tiny orifice due
to the effect of the leading edge of the orifice. In the case of a sharp-edged orifice, the
effective diameter is 0.65 times the actual diameter. However, in the case of an orifice
whose leading edge is rounded with a radius roughly equal to that of the orifice itself,
the factor is approximately 1.0. This factor, which can vary between 0.65 and 1.0 is
known as the orifice coefficient. As the flow of any fluid through an orifice is proportional
to the square of the diameter, the flow is reduced by up to (0.65) = 44% depending on
the shape of the leading edge. Figure A below shows flow through a sharp-edged orifice,
and figure B the flow through a rounded orifice as previously described.
Due to the number of factors involved, the preferred method of arriving at the required
orifice diameter for a given restriction is to estimate the approximate diameter and then
carry out a meaningful set of tests using a range of orifices with diameters around that
estimated. Note that these test orifices should all have the same leading-edge
characteristics. From the results of the test, a constant can be derived that will be
applicable for the particular set of circumstances and units. For example, if a pressure
management point is moved on a gas flow test rig a different constant might have to be
established because pressure varies throughout a moving gas in an irregular channel.
It is easy to measure the diameter of an orifice but almost
impossible to measure the leading edge radius on a tiny
orifice with normally available equipment
Formulae for Liquid Flow
For liquids where the pressure at the orifice is known in units of length (head),
where Q is the mass flow rate in units of mass/time, D is the orifice diameter in units of
length and h is the head also in units of length.
For liquids where the pressure at the orifice is known in units of pressure,
where Q is the mass flow rate in units of mass/time, D is the orifice diameter in units of
length and P is the pressure in units of mass/(length)squared.
Note that the units for the constant, although not relevant, are different for units of
pressure and for units of head.
Formulae for Gases
There are two sets of circumstances for gas flow depending on whether the gas flow is
subsonic or supersonic. Supersonic flow is independent of downstream conditions
because pressure waves cannot travel upstream at greater than the speed of
sound. Airflow is supersonic when the absolute upstream pressure is greater than 1.89
x the absolute downstream pressure.
For supersonic gas flow,
where Q is the mass flow in units of mass/time, D is the orifice diameter in units of
length, P1 is the upstream pressure in units of mass/length_squared, and T1 is the
upstream absolute temperature in whichever temperature scale is chosen.
There is a wide variety of formulae developed for subsonic gas flow. For example,
Rather than use this or any other unwieldy equations and because assumptions would
have to be made, the simple solution is to use the supersonic forumla and allow for a
reduction in flow when making the initial guess.
Formula to derive Formula to calculate
Summary
constant flow
Liquids where head is
known
Liquids where pressure is
known
Supersonic gas flow