Microscopic Examination of Cell Structure
Microscopic Examination of Cell Structure
Learning Goals:
To name the parts of the basic light microscope, and be able to explain their functions
To view specimens with the compound light microscope in the correct focal plane
To calculate magnifications and visual field diameters for different objective lenses
To estimate the lengths of cells and structures in a microscope field
To understand the relationship between linear dimensions of a cell and its volume
To understand the similarities and differences between prokaryotes and eukaryotes
Background info:
Unicellular life comes in a variety of shapes and sizes. Among the prokaryotes,
there are rod-shaped organisms, spherical, spiral-shaped, and even square ones.
Eukaryotic single-celled organisms show tremendous diversity in intracellular
organization. In this exercise we will observe several different types of microbes.
Because they are too small to be seen with the unaided eye, they must be observed
using a microscope.
We have discussed the concept that the cell is the smallest unit that has the
characteristics of life. Multicellular organisms that are big enough to see with your naked
eye are still made up of many smaller cells. In order to understand how living
organisms function, you need to understand how individual cells function. It's important
for you to become familiar with the use of the compound light microscope to better
understand cell biology. In lab you will learn about two types of cells. Prokaryotic cells
lack a nucleus and membrane-bound organelles and tend to be 0.5-5 um in size.
Eukaryotic cells have a membrane-enclosed nucleus that serves to contain and
separate the DNA and other nuclear components from the remainder of the cell. Other
organelles, such as mitochondria and chloroplasts, are also surrounded by membranes
within the eukaryotic cell. Eukaryotic cells are usually between 5-50 um in size. In
today’s lab you will learn to locate, visualize, and measure individual cells using a
compound light microscope.
Reminder: What is the mathematical formula for calculating the surface area of a
sphere? What is the formula for the volume of a sphere?
Surface area =
Volume =
volume
What would these differences in surface area and volume mean for nutrient distribution
and waste exchange for each of these cells?
Bonus: By what factor would the cell mass change as a cell’s length goes from 1 um to
10 um, assuming the cytoplasm would have the same density for both cell sizes?
Microscope Parts:
Arm: Supports the lenses, stage, and nosepiece and provides a carrying handle. Take
special care when moving or carrying the microscope. Place one hand
under the microscope and the other hand should be grasping the arm.
Base: The bottom of the microscope which sits on the table. It contains the power
controls, power cord, and the light source.
Ocular lenses: The lenses you look through. Ocular lenses have a magnification of
10X. Note the ridged diopter adjustment ring around the base of the left
ocular—this can be used to adjust the microscope focus independently for the
left and right eyes (see procedure later in this lab packet).
Objective lenses: There are 4 objective lenses on your microscope each with a
different magnifying power. You will find this number stamped on the side of the
objective lens. Multiply the magnification of the ocular lens times the
magnification of the objective lens to calculate the total magnifying power of the
combined lenses. The 4 lenses are:
4X or scanning objective. Use this for scanning the whole slide and pinpointing
the area to be observed. This is the shortest of the objective lenses so there is a
greater distance between slide and the objective. When the slide is in focus, there is
still space between the slide and the objective lens so it won’t be possible to rotate
the objective lens into the slide and break it. It is possible to bash into the slide with
the higher objectives and damage the scope. That is why this and the 10X
objective are the only objectives you can use with the coarse adjustment
knob. Always start and finish your microscope use with the 4X objective.
10X or low power objective: Allows you to view objects in greater detail. This is a
longer lens so you need to be careful using it.
40X or high dry objective: Allows you to view objects in even greater detail. This
is a longer lens so you need to be careful using it. Use only the fine adjustment
knob with this lens.
Nosepiece: Holds the objectives and rotates them into position. Start with the 4X
objective in the viewing position and rotate in a clockwise circle to the next
highest powered objective. To prevent damage to your slide and to the
microscope, Never rotate the nosepiece unless you are looking directly at
the slide and objective lenses with your naked eye!
Mechanical stage: A movable platform that holds the slide and brings it up to viewing
distance.
Stage clips: Stage clips hold the microscope slide in place on the mechanical stage
with a spring-loaded clamp. Open the movable arm of the clip and place the
slide between the clips. Gently release the arm. Snapping the arm onto the
slide can chip the slide. Never lift the stage clips up. The slide fits between
the clips, not under the clips.
Coarse adjustment knob: This is the large knob which is located on both sides of the
microscope arm. It rapidly raises the mechanical stage up to viewing distance
and brings the slide into focus. Use only with the 4X objective.
Fine adjustment knob: This is the small knob located in front of the coarse adjustment
knob. It barely moves the mechanical stage. Use it to fine tune your focus with
any objective.
Mechanical stage control knobs: They are located on the right hand side of the
mechanical stage and move the microscope slide position. The top knob
controls front to back movement and the bottom knob controls left to right
movement.
Condenser: The lens system below the stage that focuses the beam of light from the
light source up to the slide. It contains the iris diaphragm. There is a height
adjustment knob for the condenser on the left side of the stage. Students
frequently mistake this knob for the stage control knobs. You shouldn’t need to
use this knob if the condenser is set high in the stage.
Iris diaphragm: It is located in the condenser and has a lever that opens and closes
it. Use this lever to adjust the light level up and down when you change
Light source: A light bulb located in the base that provides light for viewing the
specimen.
Power switch: Located on the front of the microscope base. Make sure the rheostat
is turned down before you turn on the power switch. This helps lengthen the
life of the bulb.
Rheostat: A dial located on the right side of the microscope base that adjusts the
intensity of the light. Set it on 7 or 8 to start viewing your slide. Most light
adjustments after that should be made with the iris diaphragm.
Objectives lenses have different lengths and the distance between the objective
and the slide is called the working distance. The lowest power objective is shorter
than the higher ones so there is a greater working distance to the slide. You can use
the coarse adjustment on 4X because the working distance is so large that you can't
lower the objective into the slide and break it. This is not true with the higher
objectives. If you use the coarse adjustment on the higher powers, you can break
the slide, scratch the objective, and damage the microscope. Please be careful—
only use the coarse focus adjustment knob with the 4X objective!
Let your instructor know immediately if you break a slide so that your microscope
can be checked. If small pieces of glass get into the controls they can strip the gears
and ruin the scope. Never force any part of a microscope that isn't moving easily. Let
us know that there is a problem.
Ideally, microscope objectives are parfocal. This means that once an objective
has been focused, you can rotate to the next highest objective and the image will stay in
coarse focus. You will only need to adjust the fine focus knob to see a clear image.
Ideally, microscopes are also parcentral. This means that if you have your slide
specimen in the center of your field of view it will remain in the center of view as you go
up in magnifying power.
The field of view (diameter of field) is the circle of light you see when you look
through the microscope. As you go up in magnification, your field of view gets
smaller. If your specimen isn't centered it will be outside your field of view when you
increase the magnifying power. If you lose your specimen at the higher powers, go
back to the 4X objective and find your specimen and start over with it well
centered. Center the specimen each time you increase magnification.
Microscope slides have depth. The depth of field is the distance you can move
through the specimen and have it remain in focus. With a thick specimen you may have
to adjust the fine focus repeatedly to see the different features of a specimen.
Sometimes when you are having trouble focusing you may be focusing on the cover slip
instead of the specimen. It is important to understand how the depth of field affects
viewing your specimen.
You may notice a needle in your field of view that does not move when the stage
is moved. The pointer may be used to show someone else a particular item of interest
on a slide. Microscope pointers are built into one of the oculars.
A. Procedure for the Care and Use of the Compound Light Microscope
Get a slide of the letter “e” from the front desk to use with these general
instructions for using your microscope.
1. Clear your work area. Remove the microscope from the cabinet always supporting it
with 2 hands; one holding the arm and the other supporting the base. Gently
place it on the table. Always pick the microscope up when moving it. Dragging it
across the counter causes vibrations that can break some small parts inside the
scope.
3. Plug in microscope. Put plastic cover back in cabinet. Make sure cabinet door is
closed.
4. Make sure the 4X objective is in place, the mechanical stage is lowered all the way
down as you look at it with your naked eye, and the iris diaphragm is all the way
opened (lever all the way to the left).
5. Clean all lenses with lens paper before use. The lens paper can be found in the
drawer above your microscope cabinet. Never clean microscope lenses with
anything but lens paper. Other types of paper or tissue contain small
sharp fibers that can permanently scratch the high-quality optical glass in
the eyepieces or objective lenses.
6. Turn on the light with the switch. Turn up the light with the rheostat to a setting of 7
or 8. Open the iris diaphragm. Once the rheostat is set, leave it alone and use
the iris diaphragm to adjust light if more adjustment is necessary.
8. Clean your microscope slide with lens paper before use. Open the movable arm of
the mechanical stage and position the slide between the arms and gently
release the arm. A hard release of the arm can chip the slide. Use the
mechanical stage control knobs to position the area of the slide to be viewed
over the circle of light on the microscope stage.
9. Adjust the width between the ocular tubes by slowly moving them apart and together
until one circle of light is visible through scope. Look at the scale between the
ocular tubes and record this number to save time in setting up your microscope
in the future. This represents your interpupillary distance. Record it here:
10. Look at the stage with your naked eye. Using the coarse focus adjustment knob,
bring the mechanical stage up towards the objective lens until the lens is
almost—but not quite--touching the slide. Make a note of the relationship
between the direction on the focus knob motion and the motion of the stage:
Which way do you have to move the knob to move the stage toward the
objective? _________________________
Note: always begin adjusting the microscope for each new slide by looking with
your naked eye as you bring the objective towards the slide. This is the best
way to avoid breaking slides and damaging the microscope!
11. Look through the oculars and slowly turn the coarse adjustment knob to bring the
mechanical stage down away from the objective lens, and the slide into
focus. The slide will be about an inch (2.5 cm) away from the 4X objective when
it is in focus. Use the fine adjustment knob to fine tune the focus. For some
objects less light may result in a better image; experiment with the iris
diaphragm.
If you wear glasses, you may wish to remove them to avoid scratching them—we
will adjust the eyepieces separately for the strength of each eye below. If you
wear contact lenses, leave them in.
12. Use the coarse adjustment knob only with the 4X objective. Never use it with
the higher powered objectives. Use only the fine focus for the higher
powered objectives. If you cannot get the slide in focus with fine adjustment
on the higher powers, go back to the 4X objective and start over.
Adjust the eyepieces for your own eyes: Close your left eye; look through only
the right eye. Remember which way you need to turn the focus knob to bring the
slide down away from the objectives. CAREFULLY use the focus knob to move
the slide down away from the objectives until it is in fine focus for your right eye.
Now close your right eye, and open your left eye. Rotate the left eyepiece’s
ridged diopter adjustment ring to bring the left eyepiece into focus on the slide.
Finally, open both eyes and make any fine adjustments to the left eyepiece to
make viewing the slide comfortable. If you feel like you are crossing your eyes,
or like moving your eyes around the slide is making you dizzy, you need to
repeat the eyepiece adjustment procedure until both objectives are in focus for
your eyes.
14. Looking directy at the slide and objective lenses with your naked eye, carefully
rotate the nosepiece around until the 10X objective locks into place. Use only
the fine adjustment knob to bring the specimen back into focus.
15. Looking directly at the slide and objective lenses with your naked eye, carefully
rotate the nosepiece until the 40X objective locks into place. Use only the fine
adjustment knob to bring the specimen back into focus.
16. Looking directly at the slide and objective lenses with your naked eye, rotate back
to the 4X objective, lower the mechanical stage (NOT the condenser!) all the way
down, and return your slide to the appropriate tray at the front desk
1. Get a slide of the letter e from the front desk and position it in the stage clips so that it
is readable. Look at the slide and draw the letter e as you see it with your naked
eye.
This is what the letter looks like with the naked eye:______________
2. Now look through the microscope and bring the letter e into focus with the 4x
objective and then bring into focus using the 10x objective. Draw the letter e as it
appears through your microscope.
3. How is the image oriented through the microscope as compared to its orientation on
the slide? Is it upside down or right side up? Is it facing the same way or is it
backwards? Circle the correct answers in the text above.
4. Use the stage control knobs to move the slide to the right while looking through the
scope.
In which direction does the specimen move when the stage moves right? ____
5. Use the stage control knobs to move the slide away from you while looking through
the scope.
In which direction does the image move when the stage moves away?_______
6. Remove the slide and put in the appropriate tray on the front desk.
1. Get a slide of a transparent ruler from the front desk and position it in the stage
clips. What is the total magnification of the scope when using the 4X objective?
Remember that the eyepieces add another factor of 10 to the magnification.
Total magnification when using the 4X objective and 10X eyepiece is _________.
Bring the ruler image into focus with the 4X objective. Position the metric side of
the ruler in the center of the field of view ("field") with one black millimeter line to
the very left of your field view. Count the millimeter lines in your field. This is the
scanning-power diameter of field.
2. Rotate the 10X objective into position as you look at the slide and objectives with
your naked eye. Then examine the slide using the eyepieces.
What is the total magnification when using the 10X objective? __________
Position the ruler so that one black line is to the left of your field. What is the
diameter of your field with the 10X objective (Don’t forget the units)? __________
3. Use the following equation which uses the scanning-power diameter of field to
calculate the low-power diameter of field.
Note: Be sure to use the total magnifications (40X for the 4X objective, 100X for
the 10X objective).
So in this case, to calculate the 100X field diameter, the equation would be
In plain English:
40X field diameter x 40X mag. = 100X field diameter x 100X mag.
10x
40x
100x
Now that you know the diameter of field with each objective, you can determine the
length of an object using one of the following methods:
Estimate the fraction of the field that is taken up by your specimen and use the
formula below to estimate the size of your specimen.
Divide the diameter of field by the number of cells that cross the diameter of field
Microbes may be viewed in either a wet mount or a stained mount. A wet mount
enables microbes to be observed in their natural (living) state, so that characteristics
such as motility, morphology, and intercellular organization can be observed. Simple
staining procedures use a single stain to help visualize the individual cells of
microorganisms that are deposited on a slide by smearing. Most dyes used in this
procedure (crystal violet, methylene blue, or basic fuchsin) contain chromophoric
(colored) cations (positively charged ions). Because the surfaces of bacterial cells have
a slightly negative charge, the positively charged dyes have an affinity for the cells. The
dyes that interact in this fashion with the bacterial cells are referred to as basic dyes.
Other dyes that are anionic, that is, those in which the chromatophore carries a negative
charge, are useful in other staining techniques. In this lab you will prepare and view
microbes in both wet and dry mounts.
The Gram stain was developed in 1884 by Hans Christian Gram, a Dutch
bacteriologist, to help study a group of spherically shaped bacteria isolated from human
lung tissue. The stain differs from other simple stains performed previously in that the
Gram stain is used to differentiate types of bacteria depending on their differing abilities
to retain a particular stain. It is therefore referred to as a differential staining technique.
The results of the Gram stain depend on the age of the culture and the amount
and timing of alcohol decolorization. The age of the culture is an important factor in the
outcome of the Gram stain. Most Gram-positive organisms will lose their Gram-positivity
with age. The Gram stain should always be performed on vigorous, actively
growing cultures (18- to 24-hour cultures usually will give excellent results). To further
complicate interpretation of results, some organisms turn out to be Gram-variable
following Gram staining. This means that some of the cells in the population will stain
purple (gram-positive) and other cells will stain red (gram-negative). Only repeated
staining of the same culture at different times will verify the existence of a truly Gram-
variable culture. Gram-variability is relatively rare; mixed results in the Gram stain most
probably occur from working with an impure culture, or either underdecolorizing or
overdecolorizing with ethanol.
The basis of the Gram stain resides in the differences in cell wall composition of
Gram-positive and Gram-negative bacteria. Be sure to read your textbook for a
complete discussion of the topic. Briefly, Gram-positive organisms have a thick cell
wall composed of peptidoglycan, a polymer containing sugars and amino acids., and a
molecule called teichoic acid. On the other hand, Gram-negative organisms have a
much thinner cell wall and have an outer membrane composed of lipopolysaccharide
and lipoprotein. On proposed mechanism is the shrinkage of pores in the thick
peptidoglycan layer of cell walls of Gram-positive organisms due to exposure to the
alcohol decolorizer. The shrinkage of the pores leads to retention of the dye complex in
gram-positive cells; whereas, the higher porosity of the thin peptidoglycan layer of
Gram-negative organisms leads to more rapid loss of the dye complex.
3. Gently heat-fix the organisms to the slide by passing the dried smears through the
flame of the Bunsen burner. A clothespin or forceps should be used to prevent
burning of fingers. Caution must be exercised not to overheat the slide.
“Cooked” slides may give inaccurate Gram stain results. Remember to heat-fix
gently, and not cook the bacteria on the slide.
4. Place smears on a staining tray rack or over a sink rack and cover the smear with the
crystal-violet stain. Allow the stain to react for 1 min.
5. Using the wash bottle provided, rinse the slide with a small amount of water. Make
sure to remove excess water by shaking the slide.
6. Cover the smear with the Gram’s iodine stain and allow to react for 1 min. Wash off
the stain with water.
7. Holding the slide at a 45” angle over the sink or staining tray, apply the decolorizer
dropwise at the top of the slide and allow the alcohol to run off the slide. Add a
maximum of 4 to 5 drops of alcohol to the slide to prevent overdecolorization.
Immediately rinse the slide with water. Remove the excess water by shaking.
9. Rinse the water and blot dry by placing between pages of the bibulous pad. Wipe the
bottom of the slide to remove excess stain that may decrease visibility.
Each person in a group of four is responsible for setting up one slide on the microscope
using the oil immersion lens. All group members must view each slide to be able
to compare the sizes and shapes of the organisms.
2. Using the 100X (oil immersion) objective. To use the 100X objective, after you
have finished viewing the specimen with the 40X objective, rotate the nosepiece
halfway between the 40X and 100X objectives, place a drop of immersion oil
onto the specimen and rotate the 100X objective into position. Check to be sure
that the oil is contacting both the lens and the slide.
After each observation at 100X, be careful to wipe the oil off of the 100X
objective using LENS TISSUE. This will help to prevent transfer of oil to the
other, non-oil objectives (the 4X, 10X, and 40X).
3. Sketch the organisms’ shapes and estimate their sizes. Record your data in Table 3.
4. Gently but thoroughly wipe the oil off of the 100X objective using lens tissue.
1. if using bacteria from agar, place a drop of dH2O on the center of slide, touch a
toothpick to bacteria on the agar and mix with the drop of water. If using
suspended liquid cultures; place a drop of liquid culture onto the slide. ,
2. Cover with a glass coverslip, using a kimwipe to absorb any excess liquid.
3. Observe the slides with the 10x and 40x objectives, and sketch them in Table 3.
DO NOT observe these wet mount slides with the 100X objective.
F. Plant cells: Elodea Check to make sure you have Elodea leaves available that
have been separated from their roots for less than 4-5 hours.
Clean all lenses with lens paper, and the stage with kimwipes.
Remove your slide from the stage and return it to the appropriate tray at the front
desk.
Turn the rheostat all the way down and turn off the power switch.
Rotate nosepiece until the 4X objective locks into place.
Lower the stage all the way.
Adjust mechanical stage so the arm isn’t sticking out.
Unplug cord and tuck it between the base and stage.
Replace dust cover.
Using 2 hands, return the microscope to its cabinet. Be careful not to hit the
oculars when replacing or removing the microscope from the cabinet.
volume (m3)
Do you think a human cell could use the same mechanisms as a bacterial cell for
moving things around its cytoplasm, given the huge difference in cell volume?
dimensions organelles
Type of cell diagram(s)
(units) present
Gram stain wet mount
Escherichia coli
(or Serratia
fonticola)
Gram stain
Rhodospirillum (no wet mount)
rubrum
Gram stain only
dimensions organelles
Type of cell diagram(s)
(units) present
Amoeba proteus
wet mount only
Euglena
wet mount only
Paramecium
caudatum
wet mount only
human cheek
cell
wet mount with
methylene blue
Elodea
wet mount
1. Make sure you can identify and name the parts of the microscope.
2. Make sure you have enough practice to be good at finding the correct focal plane
for observing your slides. You will be tested on this ability during the Laboratory
Practical Exam later in the semester. Practice makes proficient!
3. How does the distance between the slide and the objective vary when objectives of
different magnification are used?
4. How does the diameter of the field of view and the amount of light in the field
change with an increase in magnification?
5. If you use a 63X objective and 10X eyepieces, what is the total magnification?
6. If the field diameter using a 5X objective is 100um, what is the field diameter using
a 20X objective? (Hint: don’t forget to account for the total magnification!)
7. If 25 cells fill the field diameter using the 20X objective in the previous question,
how long is each cell, in um?
9. If you filled the cube in question 8 with water, how much would that water weigh?
14. Calculate the volume of a rod-shaped bacterium (rounded ends) that is 3 μm long
and 1 μm in diameter. Hint: the middle of the bacterium is like a cylinder, and
the two rounded ends are like two halves of a sphere.
15. How many of the bacteria above could fit into a spherical white blood cell (d = 15
μm)
16. 1.0 mL of culture containing 3 x 109 bacteria is centrifuged, what would be the pellet
volume, using the individual cell volume calculated in #14 above?
17. What fraction of the total culture do the bacteria make up in question #16 above?