Load calculation
1. Live Load
LL < 3KN
i. Roof Live Load 0.75 kN/m2
ii. Office Area 2.5 kN/m2
LL > 3KN
i. Restaurant 4 kN/m2
ii. Staircase 3 kN/m2
2. Tank Load
Capacity of Water tank 1000 Litre = 1 m3
No. of tank 4
Density of water 1000 kg/m3
Volume/area of material (per 1m2) 0.13
Weight per unit area 0.5 kN/m2
Truss Load
Weight of member / meter
Length of member
Weight of truss / meter
oad calculation
Tile finishing (per 1m2)
Unit Weight Volume/
Total
SN Material area of
Weight Unit weight
material
2 35 mm screed for tiles 20.40 KN/m3 0.035 0.71
3 10 mm ceramic tiles 26.70 KN/m 2
0.010 0.27
4 12.5 mm Ceiling Plaster 20.40 KN/m3 0.013 0.26
5 False Ceiliing 17.25 KN/m 3
0.015 0.26
Grand Total (KN/m2) 1.50
Wall Load Calculation
For 9" Brick wall ( Per meter length)
Total
Breadth Height Quantity Density
SN Material Weight
(m) (m) (m2) (KN/m3)
(KN/m)
1 Brick work in 1:6 mortar 0.23 3.0528 0.7 19.0 13.3
2 12.5 mm wall plaster ( Both sides) 0.0125 3.0528 0.08 20.4 1.63
Total 14.93
35% opening 9.70
15% 12.69
For 4.5" partition wall ( Per meter length)
Total
Breadth Height Quantity Density
SN Material Weight
(m) (m) (m2) (KN/m3)
(KN/m)
1 Brick work in 1:6 mortar 0.115 3.0528 0.35 19.0 6.65
2 12.5 mm wall plaster ( Both sides) 0.0125 3.0528 0.08 20.4 1.63
Total 8.28
15% opening 7.04
30% 5.80
For Toughened glass wall ( Per meter length) Total
Breadth Height Quantity Density
SN Material Weight
(m) (m) (m2) (KN/m3)
1 Toughened Glass 0.013 1 0.01 25.0 (KN/m)
0.25
Total 0.25
15% opening 0.21
30% 0.18
For parapet wall ( Per meter length)
Total
Breadth Height Quantity Density
SN Material Weight
(m) (m) (m2) (KN/m3)
(KN/m)
1 Parapet 0.152 1 0.15 25.0 3.75
Total 3.75
For 8" AAC block wall ( Per meter length)
Total
Breadth Height Quantity Density
SN Material Weight
(m) (m) (m2) (KN/m3)
(KN/m)
1 AAC Block 0.2 4 0.8 8.0 6.4
2 12.5 mm wall plaster ( Both sides) 0.0125 4 0.1 20.4 2.04
Total 8.44
35% opening 5.49
15% 7.17
Wall Load Calculation
For 4" Dry wall ( Per meter length)
Total
Breadth Height Quantity Density
SN Material Weight
(m) (m) (m2) (KN/m3)
(KN/m)
1 Dry wall 0.016 3.06 0.05 13.0 0.65
Total 0.65
35% opening 0.42
15% 0.55
For 14" Brick wall ( Per meter length)
Height Quantity Density
Remarks SN Material Breadth (m)
(m) (m2) (KN/m3)
1 Brick work 0.23 3.15 0.72 19.0
2 12.5 mm wa 0.0125 3.15 0.08 20.4
KN/m Total
KN/m 35% opening
KN/m 15%
For 14" Brick wall ( Per meter length)
Height Quantity Density
Remarks SN Material Breadth (m)
(m) (m2) (KN/m3)
1 Brick work 0.2032 3.86 0.78 19.0
2 150 mm R 0.15 3.86 0.58 20.4
KN/m Total
KN/m 35% opening
KN/m 15%
1.36
Remarks
KN/m
KN/m
KN/m
Remarks
KN/m
Remarks
KN/m
KN/m
KN/m
Remarks
KN/m
KN/m
KN/m
For 24 Gauge CGI Sheet ( Per meter length)
Length Breadth
SN Material Thk (m)
(m) (m)
1 CGI Sheet 4.445 2.7096 0.00051
T
Total
Weight Remarks
(KN/m)
13.68
1.63
15.31 KN/m
9.95 KN/m
13.01 KN/m
Total
Weight Remarks
(KN/m)
14.82
11.83
26.65 KN/m
17.32 KN/m
22.65 KN/m
Total
Quantity Density Weight
Weight Remarks
(m3) (KN/m3) (kN)
(KN/m)
0.0061 78.5 0.4789 0.177
Total 0.177 KN/m
4.420523
AB-23 9" 4.5" Mid-EF (Toilet)
Length (m) 8.113 L B Length (m)
Load (kN/m) 9.76 5.3721 2.2606 Load (kN/m)
Load (kN) 79.18288 0 Load (kN)
Load (kN/m2) 6.5 Load (kN/m2)
DE-56
DE-13 Length (m)
Length (m) 3.048 L B Load (kN/m)
Load (kN/m) 8.28 3.048 5.334 Load (kN)
Load (kN) 25.23744 Load (kN/m2)
Load (kN/m2) 1.56
EF-13
Length (m)
EF-13 Load (kN/m)
Length (m) 3.2766 L B Load (kN)
Load (kN/m) 9.08 5.2578 4.2926 Load (kN/m2)
Load (kN) 29.75153
Load (kN/m2) 1.32
d-EF (Toilet) BC-56
3.2766 1.33985 L B Length (m) 3.8354 L B
13.97 6.985 4.2926 4.1085 Load (kN/m 13.97 3.937 5.5118
55.13295 Load (kN) 53.58054
3.13 Load (kN/m 2.47
BC-56
3.8354 L B Length (m) 3.8354 L B
13.97 3.937 3.1623 Load (kN/m 13.97 6.1659 5.5118
53.58054 Load (kN) 53.58054
4.31 Load (kN/m 1.58
3.8354 L B
11.87 4.7244 3.937
45.5262
2.45
3036 mm2
DWA RESIDENCE
Zone Factor ,Z 0.36 Clause 6.4.2, Table 2
Importance Factor, I 1 Clause 6.4.2, Table 6
Response Reduction Facto, R 5 Clause 6.4.2, Table 7
Height of Structure, H (m) 7.366 m
Time period of structure ( Ta =0.075 H0.75 ) in sec 0.335 Clause 7.6.1 sub clause b
Base dimension in x 22.4409 m
Base dimension in y 13.2588 m
Time period of structure ( Ta =0.09 H/d0.5 ) for x (in sec) 0.117 Clause 7.6.1 sub clause c
Time period of structure ( Ta =0.09 H/d0.5 ) for y (in sec) 0.152 Clause 7.6.1 sub clause c
Average Response Acceleration Coefficeint (S a/g) 2.50 Clause 6.4.2, Figure 2
Design Horozontal Seismic Coefficieent (A h=ZI/2R*sa/g ) 0.0900 Clause 6.4.2
Zone Factor ,Z 0.36 Clause 6.4.2, Table 2
Importance Factor, I 1 Clause 6.4.2, Table 6
Response Reduction Facto, R 5 Clause 6.4.2, Table 7
Height of Structure, H (m) 21.726 m
Time period of structure ( Ta =0.075 H0.75 ) in sec 0.755 Clause 7.6.1 sub clause b
Base dimension in x 15.621 m
Base dimension in y 26.0985 m
Time period of structure ( Ta =0.09 H/d0.5 ) for x (in sec) 0.412 Clause 7.6.1 sub clause c
Time period of structure ( Ta =0.09 H/d0.5 ) for y (in sec) 0.319 Clause 7.6.1 sub clause c
Average Response Acceleration Coefficeint (S a/g) 2.21 Clause 6.4.2, Figure 2
Design Horozontal Seismic Coefficieent (A h=ZI/2R*sa/g ) 0.0796 Clause 6.4.2
2280
Vb 47 m/s
k1 1
k2 1
k3 1
Vz 47
Pz 1.19286 kN/m2
Conference Block B
For 0.9164 m section Live load
Wind load per m 1.093 0.6873
0.018
For 0.9106 m section Live load
Wind load per m 1.086 0.68295
0.018
Conference Block C
For 1.017 m section Live load
Wind load per m 1.213 0.76275
CGI load per m 0.020
For 0.8843 m section Live load
Wind load per m 1.0548 0.663225
CGI load per m 2.070135
For m section Live load
Wind load per m 0.000 0
CGI load per m 0
4.2464
4.2693
16.25803