CX15
Patient Monitor
Version 1.1
Main Unit Specification
Physical Specifications Interfaces and Others
Dimension 383.3 mm (W) × 268.7 mm (H) × 182.4 mm (D) Analog Output 1
Weight 5.0 kg (Standard configuration with battery, Defibrillator 1
excluding recorder and accessories) Synchronization
Nurse Call 1
Power Supply USB Interfaces 2
AC Voltage 100 V to 240 V Video Output Interface 1
Input Current 0.6 A to 0.3 A Ethernet interface
Frequency 50 Hz/60 Hz (RJ-45) 1
Over Current Fuse Support
Protection ECG
Lead Mode 3 Electrodes: I, II, III
Battery 5 Electrodes: I, II, III, aVR, aVL, aVF, V
Battery Type Rechargeable lithium-ion battery 6 Electrodes: I, II, III, aVR, aVL, aVF, and leads
corresponding to Va Vb
Operating Time One battery ≥3h
10 Electrodes: I, II, III, aVR, aVL, aVF, V1-V6
(2550 mAh)
Lead naming style AHA, IEC
One battery ≥6h
(5100 mAh) Display Sensitivity ×0.125, ×0.25, ×0.5, ×1,×2,×4, AUTO gain
Charge Time One battery ≤ 3.5 h (monitor is off) Sweep 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
(2550 mAh) ≤ 5.5 h (monitor is on or standby) Bandwidth (-3 dB) Diagnosis: 0.05 Hz to 150 Hz
One battery ≤ 6.5 h (monitor is off) ST: 0.05 Hz to 40 Hz
(5100 mAh) ≤ 11 h (monitor is on or standby) Monitor and Monitor (Hi-Fi): 0.5 Hz to 40 Hz
Surgery: 1 Hz to 20 Hz
Enhanced: 2 Hz ~18 Hz
Display
Customized: High-pass Filter and Low-pass Filter
Display screen 15.6-inch color TFT, supporting touch screen (See Changing the ECG Filter Settings)
Resolution 1920 × 1080 CMRR Diagnosis: > 95 dB
Messages A maximum of 12 waveforms ST: > 105 dB
Monitor and Monitor (Hi-Fi): > 105 dB
Recorder Surgery: > 105 dB
Enhanced: > 105 dB
Record Width 48 mm
Customized: > 105 dB (Low-pass Filter < 40 Hz)
Record Paper Width 50 mm > 95 dB (Low-pass Filter > 40 Hz)
Paper Speed 12.5 mm/s, 25 mm/s, 50 mm/s In diagnosis, ST, monitor, surgery, enhanced and
Hum Filter
Number of waveform A maximum of 3 customized modes: 50 Hz/60 Hz (Hum Filter can
channels be turned on or off manually)
Recovery Time After < 5 s (measured without electrodes as IEC60601-
Defibrillation 2-27:2011, Sect. 201.8.5.5.1 requires.)
Data Storage
ESU Protection Cut mode: 300 W
Trend data 48 hours @ 1 s
Coagulation mode: 100 W
240 hours @ 1 min
Restore time: ≤10 s
NIBP Measurement At least 1600 sets
Pace pulse detection one among I, II, III, aVR, aVL, aVF, V1-V6
Alarm Events Up to 1800 sets
Full Disclosure 48 hours @ 1 s
Waveform Heart Rate
Range ADU: 15 bpm to 300 bpm
PED/NEO: 15 bpm to 350 bpm
Wi-Fi
Accuracy ±1% or ±1 bpm, whichever is greater
IEEE 802.11a/b/g/n
Resolution 1 bpm (For display and alarm limit)
Frequency Band 2.4 G/5 G
Features and specifications are subject to change without prior notice. No reproduction, copy or transmission may be made without written
permission. Not all products or features are available in all countries, contact Edan for local availability.
PVCs DIA: 10 mmHg to 200 mmHg
Range ADU: 0 to 300 PVCs/ min MAP: 15 mmHg to 215 mmHg
PED/NEO: 0 to 350 PVCs/ min Neonatal Mode SYS: 25 mmHg to 140 mmHg
Resolution 1 PVCs/min (For display and alarm limit) DIA: 10 mmHg to 115 mmHg
MAP: 15 mmHg to 125 mmHg
Cuff Pressure 0 mmHg to 300 mmHg
Pause/min Measuring Range
Range ADU/PED/NEO: (0 to 30) pauses/min Pressure Resolution 1 mmHg (For display and alarm limit)
Resolution 1 pause/min (For display and alarm limit) Maximum Mean Error ±5 mmHg
Maximum Standard 8 mmHg
ST value Deviation
Range -2.0 mV to +2.0 mV Maximum Measuring Adult/ Pediatric: 120 s
Accuracy -0.8 mV to +0.8 mV: ±0.02 mV or 10%, Period Neonatal: 90 s
whichever is greater. Typical Measuring iCUFS measurement: 20 s to 35 s
Beyond this range: not specified. Period iFAST measurement: 15 s
Resolution 0.01 mV (For display and alarm limit) Dual Independent Adult: (297±3) mmHg
Channel Overpressure Pediatric: (245±3) mmHg
QT measurement Protection
Neonatal: (147±3) mmHg
Range 200 ms ~ 800 ms
Resolution 4 ms (For display) EDAN Module SpO2
Accuracy ± 30 ms Measuring Range 0% to 100%
Resolution 1%
QTc measurement Data update period 1s
Range 200 ms ~ 800 ms Accuracy Adult/Pediatric: ±2% (70% to 100% SpO2)
Resolution 1 ms (For display and alarm limit) Undefined (0% to 69% SpO2)
Neonatal: ±3% (70% to 100% SpO2)
ΔQTc measurement Undefined (0% to 69% SpO2)
Range -600 ms ~ 600 ms
Resolution 1 ms (For display and alarm limit) PI (Perfusion Index)
Measuring Range 0.05% to 20%, invalid PI value is -?-.
Arrhythmia analysis Resolution 0.01% (0.05%-9.99%)
Asystole, V-Fib/V-Tach, Couplet, Vent Rhythm, PVC Bigeminy, PVC 0.1% (10.0%-20.0%)
Trigeminy, Tachy, R on T, PVC, Irr Rhythm, Brady, Missed Beat, Pacer not
Pacing, Vent Brady, Pacer not Capture, VEB, Run PVCs, Acc. Vent Rhythm,
IPVC, Non-Sustain VT, Non-Sustain VT, Pauses/min High, Pause, Afib, PAC PR
Bigeminy, PVCs High, Low Voltage(Limb), ExtremeBrady, PAC Trigeminy, PR (SpO2)
Wide QRS Tachy, Sustain VT, ExtremeTachy, V-Tach Measuring range 20 bpm to 300 bpm
Accuracy 2 bpm
RESP Resolution 1 bpm (For display and alarm limit)
Method Impedance between RA-LL, RA-LA PR (NIBP)
Measurement lead Options are lead I and II. The default is lead II. Measuring range 40 bpm to 240 bpm
Measuring range 0 rpm to 200 rpm Accuracy ±3 bpm or 3.5%, whichever is greater
Resolution 1 rpm (For display and alarm limit) Resolution 1 bpm (For display)
Accuracy 0 rpm to 120 rpm: ±1 rpm PR (IBP)
121 rpm to 200 rpm: ±2 rpm 20 bpm to 300 bpm
Measuring range
Gain Selection ×0.25, ×0.5, ×1, ×2, ×3, ×4, ×5 30 bpm to 300 bpm: 2 bpm or 2%, whichever is
Accuracy
Sweep 6.25 mm/s, 12.5 mm/s, 25.0 mm/s, 50.0 mm/s greater
No Breath Detected 10 s, 15 s, 20 s (Default), 25 s, 30 s, 35 s, 40 s 20 bpm to 29 bpm: Undefined
Alarm Time Setup Resolution 1 bpm (For display and alarm limit)
EDAN Module NIBP TEMP
Method Oscillometry Channel 2
Mode Manual, Auto, Continuous, Sequence Sensor Type YSI-10K and YSI-2.252K
Measuring Interval in 1/2/2.5/3/4/5/10/15/30/60/90/120/180/240/360/48 Technique Thermal resistance
Auto Mode 0 min and User Define
Measure Parameter T1, T2, TD (the absolute value of T2 minus T1)
Continuous 5 min, interval is 5 s
Position Skin, cavity
Measuring Type SYS, DIA, MAP, PR
Unit °C, ºF
Measuring Range
Measuring Range 0°C to 50°C (32ºF to 122ºF)
Adult Mode SYS: 25 mmHg to 290 mmHg
Resolution (For display 0.1°C (0.1ºF)
DIA: 10 mmHg to 250 mmHg
and alarm limit)
MAP: 15 mmHg to 260 mmHg
Accuracy (1) Sensor accuracy: 25°C ~45°C: ±0.1;
Pediatric Mode SYS: 25 mmHg to 240 mmHg Others: ±0.2°C
Features and specifications are subject to change without prior notice. No reproduction, copy or transmission may be made without written
permission. Not all products or features are available in all countries, contact Edan for local availability.
(2) Without sensor accuracy: ±0.1°C Compliant with IEC 60601-1; IEC 60601-1-2; EN 60601-1;
Transient Response Standards EN 60601-1-2; IEC 80601-2-49
Time ≤30 s Anti-electroshock Type Class I equipment and internal powered equipment
Anti-electroshock CF
IBP Degree
Channel 2 Ingress Protection IPX1
Technique Direct invasive measurement
Measuring Range -50 ~ +360 mmHg Environmental Specifications
Resolution 1 mmHg (For display and alarm limit) Temperature Working: +0°C to +40°C (32ºF ~ 104ºF)
Accuracy ±2% or ±1 mmHg, whichever is greater Transport and storage: -20°C to +60°C (-4ºF ~
(not including sensor) 140ºF)
Unit kPa, mmHg, cmH2O Relative Humidity Working: 15%RH to 95%RH (non-condensing)
Transport and storage: 10%RH to 95%RH (non-
condensing)
EDAN G2 Sidestream Module CO2
Barometric Pressure Working: 57 kPa to 107.4 kPa
Intended patient Adult, pediatric, neonatal
Transport and storage: 16 kPa to 107.4 kPa
Measure Parameters EtCO2, FiCO2, AwRR
Unit mmHg, %, kPa
Measuring Range EtCO2: 0 mmHg to 152 mmHg
FiCO2: 0 mmHg to 50 mmHg
AwRR: 0 rpm to 150 rpm
Resolution EtCO2: 1 mmHg
FiCO2: 1 mmHg
AwRR: 1 rpm
EtCO2 Accuracy
Typical conditions: ±2 mmHg, 0 to 40 mmHg
Ambient temperature: ±5% of reading, 41 to 70 mmHg
(25 3) C
±8% of reading, 71 to 100 mmHg
Barometric pressure:
(760 10) mmHg ±10% of reading, 101 to 150 mmHg
Balance gas: N2
Sample gas flowrate: 100
ml/min
AwRR Accuracy ±1 rpm
Sample Gas Flowrate 50 ml/min, 70 ml/min or 100 ml/min (optional),
accuracy: ±15 ml/min
Warm-up Time Display reading within 20 s; reach to the designed
accuracy within 2 minutes.
Response Time < 4 s (with 2 m gas sampling tube, sample gas
flowrate: 100 ml/min&70 ml/min)
< 5.5 s (with 2 m gas sampling tube, sample gas
flowrate: 50 ml/min)
Barometric Pressure Automatic (The change of barometric pressure
Compensation will not add additional errors to the measurement
values.)
Zero Calibration Support
Calibration Support (It is recommend to be operated by
trained personal.)
No Breath Detected 10 s, 15 s, 20 s (Default), 25 s, 30 s, 35 s, 40 s
Alarm Delay
C.O.
Technique Thermodilution Technique
Measure Parameters C.O.: TB, TI
Measuring Range C.O.: 0.1 L/min to 20 L/min
TB: 23°C to 43°C (73.4ºF to 109.4ºF)
TI: -1°C to 27°C (30.2ºF to 80.6ºF)
Resolution (For C.O. : 0.1 L/min
display and alarm TB, TI : +0.1°C (+0.1ºF)
limit)
Accuracy C.O.: ±5% or ±0.2 L/min, whichever is greater
TB: ±0.1°C (±0.18 ºF) (not including sensor)
TI : ±0.1°C (±0.18 ºF) (not including sensor)
Safety Specifications
Features and specifications are subject to change without prior notice. No reproduction, copy or transmission may be made without written
permission. Not all products or features are available in all countries, contact Edan for local availability.