Technical Datasheet

Revision No.: 6.2


Revision Date: 20.04.2021
Document Code: TE-101-207 H2S SCAVENGER P [Link]

Description
H2S Scavenger P is a powder zinc-based mixture which is used as hydrogen sulfide scavenger for water-based muds. H2S
Scavenger P reduce corrosion of downhole tools and surface equipment in oil-field which is related to H2S gas. H2S Scavenger P
reacts relatively fast and is optimum for removing H2S in shortest time.

Application
Main function of H2S Scavenger P is decreasing the corrosion rate of drilling fluids and brines, reducing H2S scavenger, and
minimize the possibility of drill pipe or casing wear-out. It is recommended to be used in wells as a pre-treatment that are
possible to produce H2S gas. The product of reactions between H2S gas and H2S Scavenger P is inert ZnS sediments. H2S
Scavenger P is compatible with different types of drilling and workover fluids.

Advantages Limitations
• Compatible with different types of drilling fluids • It is recommended to be used in fluids with pH
and oil-field brines (monovalent and divalent ions) range of 11.5 to 12.5.
• Effective in different salinities • In fluids with high pH (>11.5), excessive use of H2S
• Fast reactions Scavenger P may cause rheological fluctuations.
• Minimum effect on filtration and rheological • H2S Scavenger P should not be used is drilling fluid
properties of fluids with pH less than 7, as it may cause H2S generation.
• No foam generation in water

Treatment
Dependent to the environment of fluids, treatments may differ from 1 to 3 ppb as a pretreatment or treatment. 3.5 pound per
barrel of H2S Scavenger P can eliminate 500-600 ppm of H2S gas. In drilling, completion or workover fluids, it is recommended,
to use corrosion inhibitors and Oxygen-scavengers alongside with H2S SCAVENGER P. Running pilot tests before adding H2S
Scavenger P is recommended.

Typical Properties Packaging


APPEARANCE White Powder H2S Scavenger P is available in 25-KG SXS.
SPECIFIC GRAVITY (20 Celsius
3.5-4.3
degrees)
pH (1% Solution) Min 7
Max.5% in water
Solubility
100% in HCl (10%)
Purity (Zinc content) Min 47% wt

The above information is believed to be correct but does not


purport to be all inclusive and shall be used only as a guide.
The information in this document is based on the present state
of our knowledge and is applicable to the product with regard
to appropriate safety precautions. It does not represent any
Address: No. 43, Souri St., 43 Ashrafi Esfahani Expressway guarantee of the properties of the product. TEAM Chemicals
and its Affiliates shall not be held liable for any damage
resulting from handling or from contact with the above
Telephone: +44 (0)207 408 7700 - +98 912 3717539 product.

Email: sales@[Link]

Website: [Link]