Print Date : 15/01/2025 02:26 Fiber Optics : 22.52 File : RX EXP_CUR.sor.

pdf

Cable Id : Cable Fiber Id/Number : Fiber 1


Location A : EXP Location B : CUR
Job ID : Technician Id :

SmartOTDR (S/N 79556) E136FB (S/N 79556) Calibration date : 12/01/2023 Date : 15/01/2025 02:24 (UTC+0)

Test Setup
OTDR Laser Pw Range Acq Time IOR Scatter Coefficient
EXPERT 1310nm 30ns 10km 30.1s 1.46750(G652 G657) -79.0 dB
Alarms
Thresholds None
Summary
Filename Laser nm Link Loss dB Link Orl dB Fiber End Km Direction Avg Loss dB/Km Event Alarms
RX EXP_CUR.sor 1310 9.269 27.49 3.718 EXP -> CUR 2.493 4

1/4 2/4 3/4 4/4

0.000 0.021 2.028 3.718 Km

A : 3.717km -9.558 dB
B : 2.026km -7.638 dB
A-B : 1.692km 1.135 dB/Km 1.920 dB

Event Distance Loss Reflect. Slope Section T. Loss


Km dB dB dB/km Km dB
1 0.000 ~ 3.447 ~ -27.00 0.000 0.000
2 0.021 3.047 -46.14 0.021 3.447
3 2.028 0.006 -11.20 0.514 2.007 7.614
4 3.718 -39.03 0.843 1.690 9.269