Guard 10

The document contains detailed plumbing plans and specifications for a construction project, including drainage and septic systems. It outlines compliance requirements with local plumbing codes and provides guidelines for installation and testing of plumbing fixtures and pipes. Additionally, it emphasizes the importance of coordination with architectural and structural plans to avoid conflicts during construction.

Uploaded by

nicosamson2315
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views1 page

Guard 10

The document contains detailed plumbing plans and specifications for a construction project, including drainage and septic systems. It outlines compliance requirements with local plumbing codes and provides guidelines for installation and testing of plumbing fixtures and pipes. Additionally, it emphasizes the importance of coordination with architectural and structural plans to avoid conflicts during construction.

Uploaded by

nicosamson2315
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

DS

DS

0.10
0.13 0.80 0.13
0.53
0.13 0.53 0.13
INLET SECTION
PLAN
2

0.10
0.10
0.13
INLET

0.23
OUTLET

0.53
INLET

0.57
0.80
0.80
CB

0.53

0.13

0.60
INLET

OUTLET

0.23

0.17
0.13
CB
1

0.13

0.13

0.13
0.10
E CK% 0.23
0.13
0.23
2
O F lD
ope 0.10 0.60 0.10

ROmin.s
OPE
L
CATCH BASIN DETAIL
S
3
P10 SCALE: 1:25 MTS.
A
B PLUMBING NOTES
ISOMETRIC VIEW

0.25
C.O.
400
C.O.
600
C.O. & SPECIFICATION

100
MANHOLE MANHOLE

1. ALL WORKS SHALL COMPLY WITH THE PERTINENT PROVISIONS OF

400
AIR SPACE AIR SPACE
INLET THE LOCAL PLUMBING ORDINANP-1S OF RIZAL ST. DAVAO CITY , THE
CODE OF SANITATION OF THE PHILIPPINES, AND/OR THE NATIONAL

1 2
OUTLET PLUMBING CODE OF THE PHILIPPINES.

2. THE CONTRACTOR IS REQUIRED TO REFER TO THE ARCHITECTURAL,

1500

1500
1750
STRUCTURAL & ELECTRICAL PLANS AND INVESTIGATE ALL POSSIBLE

1100
INTERFERENP-1 & CONDITIONS AFFECTING HIS WORK.
LEACHING CHAMBER DIGESTIVE CHAMBER
5.00 3. WHERE ACTUAL CONDITIONS @ THE JOBSITE NEP-1SSITATE A
DEVIATION OR REARRANGEMENT, THE CONTRACTOR SHALL
5% SLUDGE PIT COORDINATE WITH THE ARCHITECT FOR PROPER DISPOSITION.

150
4. TEST ALL WATER SUPPLY & DISTRIBUTION SYSTEM, DRAINS, SEWER,

100
STORM & VENT SYSTEM.

5. SEWER AND VENT LINES BE POLYVINYL CHLORIDE (PVC) PIPE SERIES

A DS 2000
1000, FOR 50mmØ TO 150mm&&C.

6. HANGERS AND SUPPORTS. HORIZONTAL LINES SHALL BE


CB 2000
SUPPORTED BY WELL SECURED LENGHT HEAVY DUTY STRAP OR
CLEVIS TYPE HANGERS. VERTICAL LINES SHALL BE SECURED

2.00
800 1200 STRONGLY BY HOOKS OR CLAMPS TO THE BUILDING FRAME AND A
SLOPE

SUITABLE BRACKET @ THE FLOORS FROM WHICH THEY START.


ROOF DECK
3.00

3.00
7. PROVIDE PIPE SLEEVES AND PROPERLY SECURED IN PLAP-1 @ ALL
min. slope 2% POINTS WHERE PIPES PASS THROUGH MASONRY OR CONCRETE.

400
C.O.
8. PLUMBING FIXTURES- COORDINATE WITH THE ARCHITECT WHAT
CB TYPE AND COLOR OF FIXTURES TO BE INSTALLED.
1.00

DS

1200

1200
600
B
9. ALL DIMENSIONS USED ON THESE PLANS ARE IN MILLIMETER (MM)
UNLESS OTHERWISE SPECIFIED.
C.O.

400
C.O.
10. SOIL OR WASTE AND STORM DRAIN PIPING SHALL BE LAID @ INCH
1
4

PER FOOT SLOPE UNLESS NOTED OTHERWISE.

4 11. CONTRACTOR SHALL COORDINATED AND HAVE THE


RESPONSIBILTY OF ALL POINT OF CONNECTION WITH OUTSIDE
3.00 2.00 UTILITIES ( STREET SEWER @ COLD WATER LINE).
400 400
2000 12 . WATER PIPE SHOULD BELOW THE MAIN WATER SUPPLY LINE.
5.00

1 STORM DRAINAGE PLAN 2 SEPTIC VAULT DETAIL


P10 SCALE: 1:25 MTS.
P10 SCALE: 1:50 MTS.

SHEET CONTENT: REPUBLIC ACT SECTION (4) ARCHITECT/ENGINEER PROJECT TITLE : REVISIONS Designed By: OWNER SHEET NO.

DRAWN
IGS AND SPECF
IC
IATO
INS DULY SGINED, STAMPED Date Remarks
OR N ISTRUMENTS OF SERVC IE ARE THE PROPERTY

10
DOCUMENTS OF THE ARCHT IECT, WHETHER THE OBJECT Drawn By:
FOR WHC IH THEY ARE MADE IS EXECUTED OR NOT. IT
SHALL BE UNLAWFUL FOR ANY PERSON WITH THE
WRITTEN CONSENT OF THE ARCHT
SAD
I
OTHER
DOCUMENTS
PROJECTS
PARTLY OR IN A WHOLE.
FOR USE N
OR BULIDN IG
IECT
I THE REPETT IO
WHETHER
IN
OR AUTHOR OF
OF AND
EXECUTED REG. NO :
TIN :
P.T.R NO:
DATE :
LOCATION :
ACAD By:
P
C.T.C NO: PLACE : Date: