EVOLUTION
IN 4D TREATMENT
SIMULATION PLAN TREATMENT
Innovative 4D SIGRT Solution
Recent advances in treatment planning and delivery systems have led to consistently
achieving optimal results. And now with the revolutionary Catalyst, you can get the same
level of confidence when controlling the only remaining variable – the patient.
The Catalyst system is a revolutionary solution for Surface Image Guided Radiation Therapy
(SIGRT), coupled with application software optimized for workflow integration.
Catalyst offers a complete solution on 3D CRT, IMRT for online patient tracking before
and during treatment delivery, thus ensuring the best possible therapeutic and palliative
treatment outcome without non-prescribed doses.
CATALYST SUPPORTS THE CLINICAL WORKFLOW
PATIENT SETUP AND POSITIONING
Posture errors projected directly on to the patient’s
skin ensure a correct patient setup and a higher
accuracy in the patient's position. With the posture
error correction, time and effort for verification
imaging can also be reduced.
INTRA-FRACTION MOTION DETECTION
With 3D intra-fraction motion detection the initial
accurate position of the patient is maintained
throughout the treatment and permits maximum
dose delivery within the target.
RESPIRATORY GATING
Using the gating solution for both free breathing and
deep inspiration breath hold (DIBH) with Audio Visual Tracks thoracic
Isocentric shift
Coaching and the interface to Major radiotherapy continuously and abdominal
suppliers enables the delivery of precisely-targeted calculated. respiratory motion.
radiation to moving tumors. This assures the most
reproducible outcome and guarantiees maximum
patient safety.
2
IN THE TREATMENT ROOM, THE SYSTEM
PROVIDES THE FOLLOWING BENEFITS
COMPARED TO OTHER SIGRT SOLUTIONS:
• Large patient surface coverage (1300x800x700mm)
• Interactive visual guidance via color map projected on patient body during setup.
• Correct any posture or positioning errors immediately.
• Absolute value calculation with baseline monitoring capability.
• Optional audio-visual coaching helps the patient follow optimal breathing patterns.
• No markers on or around the patient
• Dose-free motion management
• Multi-vendor interfaces have been developed to ensure a seamless clinical workflow, i.e. Varian
TrueBeam, C-series; Elekta VersaHD, Infinity, Synergy.
COLOR
BACKPROJECTION
DIBH INTEGRATION
VISUAL
QA
COACHING
* TrueBeam, C-Series are the trademarks of Varian Medical Systems, Inc. VersaHD, Infinity, Synergy are the trademarks of Elekta AB.
3
CLINICAL BENEFITS
The Innovative 4D SIGRT solution from
C-RAD is an end-to-end treatment
solution for radiation therapy. For Deep
Inspiration Breath Hold treatment, it
starts from the 4DCT simulation in the
CT room and carries all the way through
treatment, including posture correction
and positioning, intra-fraction real-
time motion monitoring, and gating
treatment. It is possible to upgrade
Catalyst to Catalyst HD.
High precision
• 1 mm accuracy
• Posture and position correction
• Reproducibility of breast
position when DIBH treated
• Long-term stability with <0.3 mm shift
per month
High Efficiency
• Non-rigid algorithm avoids
extra steps for ROI design
• Prompt posture correction with
patented color map back projection
• Visual coaching to ensure a smooth
gating delivery
Patient Safety
• Doseless and markerless
• Both posture and position
correction
• Auto patient data retrieval
• Auto couch shift for position correction
• Auto beam control
• Double monitoring on intra-fraction
motion and gating window
For more information please visit:
[Link]
SP-002-110429-001-02
REDEFINING PRECISION IN
ADVANCED RADIATION THERAPY
Light projection
• Wavelengths: 405 nm (near-invisible violet),
528 nm (green), 624 nm (red)
SYSTEM DATA
Performance
Physical dimensions • Scan volume (X * Y * Z): 800 mm x 1300 mm x
• Size (W x D x H): 620 mm x 280 mm x 400 mm 700 mm.
• Weight: 16 kg (35 lbs) • Measurement reproducibility: 0.2 mm
• Long-term stability: 0.3 mm
Power • Warm-up time: 30 minutes
• Input voltage: 100 – 240 VAC • Scan speed: Up to 80 complete 3D surfaces
• Frequency: 47 – 63 Hz per second
• Power consumption: 1.8 A • Registration method: Real-time, non-rigid
with deformable models for computing 6 DOF
Environment isocentric shifts
• Operating temperature: +10 °C to +35 °C • Positioning accuracy: Within 1 mm for rigid body
(50 °F to 95 °F) • Motion detection accuracy: Within 1 mm
*Full system data upon request
C-RAD AB (publ) C-RAD GmbH
C-RAD Positioning AB Wittestr. 30 K, 13509 Berlin, Germany
Sjukhusvägen 12K, SE-753 09 Uppsala, Telephone: +49 30 609847560
Sweden Telephone +46 18-66 69 30
C-RAD (Shanghai)
C-RAD Inc. Medical device Co. Ltd.
70 SE 4th Ave, Delray Beach, FL 33483, USA Block 2 Room 503,
Telephone: +1 561 742 9260 No 608 Shengxia Road
Pudong new Area, Shanghai, China
[Link]