ID# 20250111114257157
PRELIMINARY RESULTS - SUBMITTED SAMPLE ANALYTICAL REPORT
SGS Reference: BS25-014.001
Client Reference: PT. GBR QQ PT. BARATAMA INTI ENERGI Date Issued: 11 January 2025
Client Reference 2.: Sample ID provided by client Date(s) Tested: 10 January 2025
Sample Type: Coal Principal: PT. BARATAMA INTI ENERGI (BIE)-IRI GROUP., JSC
Sample Received From: Client Address: RIZQIN GASTRO PTE., LTD.
Sample Description: Packed in plastic bag, good condition without seal Perumahan Palm Hills City, Jl. Raya Daksa
Date Sample received: 5 January 2025_[Link] PM City, State, Postal: Sepinggan, Balikpapan, Kalimantan Timur
Seal Numbers: - Country: Indonesia
Sample Confirmation: 9 January 2025 Attention: Mr. Ardiansyah
The sample(s), to which the findings recorded herein (the "FINDINGS") relate, was (were) drawn and / or provided by the Client or a third party acting on Client's directions.
The Findings constitute no warranty of the sample's representativity of all the goods and strictly relate to the sample(s). The Company accepts no liability with regard to the
origin or source from which the sample(s) is /are said to be extracted.
Additional Information
9.862 kg coal sample supplied by PT. BARATAMA INTI ENERGI (BIE) - IRI GROUP., JSC - RIZQIN GASTRO PTE., LTD.
Sample appeared to contain no stone or rock, nominal top size is around 75 mm
Analysis performed in accordance with ASTM Standards or other International Standards and SGS Procedures.
As-Received As-Determined Dry Basis (db) Dry Ash-Free
Basis (ar) Basis (ad) Basis (daf)
Proximate Analysis Moisture % 6.46 4.20 ----- -----
Moisture (Total) * Ash * % 15.37 15.74 16.43 -----
Moisture (as-determined) * ASTM Volatile Matter * % 41.18 42.17 44.02 52.67
Fixed Carbon (calculation by difference) % 36.99 37.89 39.55 47.33
Total Sulfur * % 0.81 0.83 0.87 1.04
Gross Calorific Value * kcal/kg 6176 6325 6602 7900
ASTM D5865 Net CV, constant pressure kcal/kg 5889 6045 6336 -------
ASTM D5865 NCV(p) requires Full Ultimate Analysis
1 of 3
ID# 20250111114257157
PRELIMINARY RESULTS - SUBMITTED SAMPLE ANALYTICAL REPORT
SGS Reference: BS25-014.001
Client Reference: PT. GBR QQ PT. BARATAMA INTI ENERGI Date Issued: 11 January 2025
Client Reference 2.: Sample ID provided by client Date(s) Tested: 10 January 2025
Ultimate Analysis Moisture (Total) * Moisture (as-determined) * As-Received As-Determined Dry Basis (db) Dry Ash-Free
Basis (ar) Basis (ad) Basis (daf)
Total Carbon * % 61.31 62.79 65.54 78.43
Total Hydrogen (includes H in moisture) * % 5.60 5.47 5.22 6.25
Total Nitrogen * % 1.07 1.10 1.15 1.37
Total Sulfur * % 0.81 0.83 0.87 1.04
Ash * % 15.37 15.74 16.43 -----
Oxygen by diff.(includes O in moisture) % 15.84 14.07 10.79 12.91
Total % 100.00 100.00 100.00 100.00
Moisture % (6.46) (4.2) ------- -------
Hydrogen (excludes H in moisture) % 4.88 5.00 DB & DAF H & O values exclude H & O in
Oxygen (excludes O in moisture) % 10.10 10.34 moisture
FSI / CSN 1
Plastic Properties of Coal by the Constant-Torque Gieseler Plastometer # Not Detected -
Hardgrove Grindability Index * 39
Signed and dated For and on behalf of
PT. SGS Indonesia - Banjarmasin Akhmad Fauzi (Coal Lab Supervisor)
11 January 2025
Akhmad Fauzi (Coal Lab Supervisor) Natural Resources Jl. [Link] km 12.9 No.105 Gambut, Kab. Banjar, Kalimantan Selatan
+62 (0)511 422 0113 [Link]
Member of SGS Group
This document is issued by the Company under its General Conditions of Service accessible at following link: [Link]
Attention is drawn to the limitation of liability, indemnification and jurisdictional issues defined therein.
Any holder of this document is advised that information contained herein reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders
may be prosecuted to the fullest extent of the law.
2 of 3
METHODS
SGS Reference: BS25-014.001
Client Reference: PT. GBR QQ PT. BARATAMA INTI ENERGI Date Issued: 11 January 2025
Client Reference 2.: Sample ID provided by client Date(s) Tested: 10 January 2025
Sample Type: Coal Principal: PT. BARATAMA INTI ENERGI (BIE)-IRI GROUP., JSC
Sample Received From: Client Address: RIZQIN GASTRO PTE., LTD.
Sample Description: Packed in plastic bag, good condition without seal Perumahan Palm Hills City, Jl. Raya Daksa
Date Sample received: 5 January 2025_[Link] PM City, State, Postal: Sepinggan, Balikpapan, Kalimantan Timur
Seal Numbers: - Country: Indonesia
Sample Confirmation: 9 January 2025 Attention: Mr. Ardiansyah
ACCREDITION STATUS: SGS Laboratory: SELECT * if analysis is included in the SGS Accreditation; Select # if analysis is NOT included in the SGS Accreditation.
Third Party Laboratory (internal or external): SELECT **, if analysis is performed by an Accredited - Third Party Laboratory", SELECT ## if analysis is performed a NON-Accredited Third Party Laboratory.
ACCREDITATION TEST STATUS
* SGS Accredited Test; # SGS Non
Accredited Test, ** Third Party Lab -
Name of Accreditation Body, Type, & Accredited, ## Third Party Lab - Non
Method Standard Executing Laboratory Registration No. Accredited Accreditation Test Status Uncertainty of Measurement
Moisture (Total Moisture)* ASTM D3302/D3302M - 22a SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
Moisture (Analysis Moisture)* ASTM D3173/D3173M - 17a SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
Ash * ASTM D3174 - 12 (2018) e1 SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
ASTM Volatile Matter * ASTM D3175 - 20 SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
Fixed Carbon (calculation by difference) ASTM D3172 - 13 (2021) e1 SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
Total Sulfur * ASTM D4239-18e1 Method A SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
Gross Calorific Value * ASTM D5865/D5865M - 19 SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
Ultimate Analysis (C,H,N, Oxygen calculation by difference)* ASTM D5373 - 21 Method A SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
Hardgrove Grindability Index * ASTM D409/D409M - 16 SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
FSI / CSN ASTM D720/D720M - 22 SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
Plastic Properties of Coal by the Constant-Torque Gieseler Plastometer # ASTM D 2639 - 2023 SGS Banjarmasin - # Non Accredited Test
Physical Attributes of Sample
Sample Preparation * ASTM D2013/D2013M-21 SGS Banjarmasin KAN-ISO 17025:2017-LP-779-IDN * Accredited
NOTE: ALL Tests subcontracted to a Third Party Laboratory (internal or external), or marked as " #, ## Not Accredited ", are not included in the SGS ISO 17025 Laboratory Accreditation.
Additional information required by the Accreditation Body.:-
Signed and dated For and on behalf of
PT. SGS Indonesia - Banjarmasin Akhmad Fauzi (Coal Lab Supervisor)
11 January 2025
Akhmad Fauzi (Coal Lab Supervisor) Natural Resources Jl. [Link] km 12.9 No.105 Gambut, Kab. Banjar, Kalimantan Selatan
+62 (0)511 422 0113 [Link]
Member of SGS Group
This document is issued by the Company under its General Conditions of Service accessible at following link: [Link]
Attention is drawn to the limitation of liability, indemnification and jurisdictional issues defined therein.
Any holder of this document is advised that information contained herein reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Any holder of this document is advised that information contained herein reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
3 of 3