Orikam Product Catalogue
Orikam Product Catalogue
Towards
Best in
Dentistry
Product Catalog
[Link]
INDEX
Neoglide 12
Neoendo Flex Glide | Pedoflex 13
K File | H File 14
C Pro | Neoprobe 15
Finishing File | Side Vent Needle 16
E-Flex Files 17-23
Neoendo Gutta Percha Points | Absorbent Paper Points 24
INDEX
Eighteeth Devices
Airotors
J1 & J1 Plus | J5 | J45 51-53
Others
Tun Ultrasonic Tips 54
Neofill Composites
Neofill Ultra 55
Neofill Flowable 56
Impression Material
Neoendo Chemicals
Neoendo Flex Files utilize a proprietary heat treatment which gives them a very
unique flexibility, flutes do not open when the stress levels are reached, yet the files
do not present shape memory.
Flexibility
To Negotiate
Any Canal
Gold Thermal Calibrated
Treatment Length Marking
Enhances
Cutting Efficiency
Safety Tip
Non-cutting Tip
Taper Indicator Triangular to Minimize Apical
Single Ring 4% Taper Cross-section Transportation
Double Ring 6% Taper Sharp Cutting Edges
KNOW
01 MORE
The Next Level of Performance
Use Flex Files/ Flex Glide Files with gentle touch, never force the file and always
use the recommended speed & torque setting
Use the file in brushing motion. Take the file passively to the point of light
resistance and brush out of the canal. Repeat the procedure until working length
is achieved
Available Sizes
Color Tip Size Taper (%) Length [mm] Speed Torque Pcs
17 4 - 21 25
20 4 6 21 25
25 4 6 21 25 Speed:
350 rpm
30 4 6 21 25
35 4 6 21 25 6 Pcs
Torque:
40 4 6 21 25
1.5 NCm
Coronal Flaring File 8 19
Assorted Pack: 17/4 | 20/4 | 25/4 | 20/6 | 25/6 | CF* 21 25 31
Assorted Big: 30/4 | 30/6 | 35/4 | 35/6 | 40/4 | 40/6 21 25
02
Progressive Variable Taper Files
Neotaper shares the same fundamental metallurgy, heat treatment and triangular
cross-section as Neoendo Flex File with a new sequence of variable taper files
High Cutting E ciency Ideal Balance of Strength and Flexibility
Minimally Invasive CTA Wire – Controlled Thermal Activation
Triangular cross-section 5%
has proven to be work
horse of rotary
endodontics
4%
Adequate area to
auger debris
Sharp
Optimized cutting edges
core size
Available Sizes Sx, S1, S2, F1, F2, F3, F4, F5 (21mm & 25mm)
KNOW
03 MORE
Progressive Variable Taper Files
Sx
Specialty instrument designed to shape and open the canal orifice.
Sx is designed to cut from the middle part.
Non-cutting tip of Sx enables it to glide through the soft tissue easily
Sx provides a safe entry path into the canal for next files- S1, S2
Finishers
Shapers
Shapers are designed with narrow tapers in the apical Finishers are designed with higher tapers
third and higher and increasing tapers in the middle in the apical third and decreasing taper
and coronal third in the middle and coronal third
Shapers are for preparing the middle and coronal third Finishers are for apical third
Narrow taper in shaping files create a path for finishers The taper decreases in coronal portion
to reach the apical third easily and clean the apical reducing chances of taper lock
third e ciently F1, F2, F3, F4, F5
S1, S2
S1 F1
S2 F2
Sx
Use Neotaper Files with gentle touch, never force the file and always use the recommended speed
and torque setting
Use the file in brushing motion Take the passively to the point of light resistance and brush out of the
canal. Repeat the procedure until working length is achieved
04
S
S-cross Section- Higher Cutting Efciency
Usage Protocol
Finishing with Neoendo S Files
Narrow 20/ 4%
Canal or 20/ 6%
Orifice Opener
(17/ 4%)
(15/2%)
K File
Medium 25/ 4%
Canal or 25/ 6%
Large 30/ 4%
Canal or 30/ 6%
Available Sizes
Color Tip Size Taper (%) Length [mm] Speed Torque Pcs
17 4 - 21 25
Speed:
20 4 6 21 25
400 rpm
25 4 6 21 25
6 Pcs
30 4 6 21 25
Torque:
35 4 6 21 25
2 NCm
Coronal Flaring File: 30/8 19
Assorted Pack: 17/4 | 20/4 | 20/6 | 25/4 | 25/6 | CF* 21
KNOW
05 MORE
Flexibility
To Negotiate Any
Canal
Calibrated
Length Marking
Safety Tip
Non-cutting Tip
to Minimize Apical
Taper Indicator Triangular Transportation
Single Ring 4% Taper Cross-section
Double Ring 6% Taper Sharp Cutting Edges
Usage Protocol
Finishing with Neoblue Files
Narrow 20/ 4%
Orifice Opener
Canal or 20/ 6%
Optional
(17/ 4%)
(15/2%)
Medium 25/ 4%
K File
Canal or 25/ 6%
Large 30/ 4%
Canal or 30/ 6%
Available Sizes
Color Tip Size Taper (%) Length [mm] Speed Torque Pcs
17 4 - 21 25
20 4 6 21 25
Speed:
25 4 6 21 25
350 rpm
30 4 6 21 25
6 Pcs
35 4 6 21 25
Torque:
40 4 6 21 25
1.5 NCm
Coronal Flaring File 8 19
Assorted Pack: 17/4 | 20/4 | 25/4 | 20/6 | 25/6 | CF* 21 25
KNOW
MORE 06
Redening Endodontics
Adequate area to 5%
augur debris
4%
Sharp Optimized Innovative Dual Surface
cutting edges core size
Thermal Treatment-
Optimized thermal
treatment properties
as per the section
of file and it’s usage
13 mm
11 mm
KNOW
07 MORE
Redening Endodontics
Usage Protocol
Narrow
#20
Canal
Orifice Opener
Neoglide File
(FWD Mode)
#25
Optional
Medium
Canal
#30
Wide
#40
Canal
Establish the working length with the help of Electronic apex locator
For obliterated, calcified canals use Neoprobe and Neoglide to achieve proper
glide path
For constricted coronal third, use Neoendo Flex Coronal Flare File
Available Sizes
Sizes: #20 | #25 OR #30 | #40 | Assorted #20, #25, #30 in 21mm and 25mm length
Corresponding GP & PP Available
08
Off-Centered Rectangular Cross-section
Usage Protocol
Finishing with Neohybrid Files
Narrow 20/ 4%
Canal or 20/ 6%
Orifice Opener
(17/ 4%)
(15/2%)
K File
Medium 25/ 4%
Canal or 25/ 6%
Large 30/ 4%
Canal or 30/ 6%
Available Sizes
File Tip Size Taper (%) Length [mm] Speed Torque Pcs
17 4 - 21 25
20 4 6 21 25 Speed:
25 4 6 21 25 350 rpm
30 4 6 21 25 4 Pcs
35 4 6 21 25 Torque:
40 4 6 21 25 1.5 NCm
KNOW
09 MORE
Size 30 | Taper 9% | Length 16mm
Rotary file sequence for e ective removal of gutta percha, resin and other
obturation material.
Three simple steps in crown down sequence for quick and easy retreatment
procedure.
Unique file design (parallelogram cross-section with active cutting tip) increases
cutting e ciency and flexibility makes it compatible with all types of canal.
Provides solutions for obturation removal, cleaning and shaping of canal during
retreatment procedure.
Usage Protocol
KNOW
MORE 10
Sharp Triangular Inactive
Cutting Edge Cross-section Safety Tip
Usage Protocol
Initial shaping with Neoendo Ultimo Files Finishing with Neoendo Flex Files
10/4% 15/5%
Narrow 25/ 4%
Canal or 20/ 6%
Orifice Opener
Optional
Medium 30/ 4%
Canal or 25/ 6%
Large 35/ 4%
Canal or 30/ 6%
Available Sizes
KNOW
11 MORE
#16
Inactive, non-ISO
2% standard tip
4%
Square Variable progressive
cross-section taper- Combine work
of multiple files into
one NeoGlide file
6%
Increased core
area for better
strength 7%
Gold thermal
treated flexible file
Save time-
Use one file
instead of multiple
files for glide path
13 mm
11 mm
preparation
11 mm short handle
for better access in
SPEED: 200 rpm narrow mouth opening
TORQUE: 1 NCm
KNOW
MORE 12
GLIDE KNOW
MORE
Due to the enhanced flexibility, small taper size (2%) and non-ISO standard tip sizes,
Neoendo Flex Glide files save time and e ort and also reduce the risk of canal
aberrations (ledges, zips and transportation).
KNOW
MORE
13
K-File KNOW
MORE
Description
Material: Stainless steel. ISO color coded hand end, made up of plastic
with serration for better grip. Passivated to prevent rusting
Cross-section: Square cross-section hand files
Tip: Non-active tip to prevent ledge formation in curved canals
High elastic & tensile strength: Less potential of file separation
Technical Features
ISO Sizes: 6 to 40, Assorted Pack 15-40 Taper of 2%
Length: 21, 25, 31 mm Packaging: x 6 Pcs
H-File KNOW
MORE
Description
Material: Stainless steel, ISO color coded, hand-end made up of plastic
with serration for better grip. Passivated to prevent rusting
Cross-section: Tear shaped cross-section with extremely sharp edges
Tip: Non-active tip to prevent ledge formation in curved canals
High elastic & tensile strength: Flexible with less potential of separation
Technical Features
ISO Sizes: 10 to 40 Taper of 2%
Length: 21, 25 mm Packaging: x 6 Pcs
14
C Pro KNOW
MORE
Description
Material: Made up of high quality carbon stainless steel. Passivated to
prevent rusting
Cross-section: Square cross-section hand files provide more bulk to the
core of the file
Tip: Active cutting tip to engage the dentin in calcified canal
High elastic & tensile strength: Sti er file with less potential of separation
Technical Features
ISO Sizes: 6, 8, 10, 12, 15 Taper of 2%
Length: 21, 25 mm Packaging: x 4 Pcs
NEOPROBE KNOW
MORE
Tip Dia: 12
Taper: 1%
nt
t i n strume
firs als
Your re t h e can
lo
to exp Calcified Canals
Blocked/Curved Canals
15
FINISHING FILE KNOW
MORE
Rounded tip
One lateral vent
Specifications
Closed front-end Guage: 30 G
Luer lock & luer hub Length: 25 mm
Sterile, single use only Hub Colour: Yellow
Encapsulated in plastic Packaging: 50/100 Pcs
container
Ideal tool for irrigation
Prevents extrusion of
irrigation solution into
periapical tissue
Eliminates the hydraulic
pressure and ensure safe
delivery of solution
16
E-FLEX GOLD
Gold Heat Treatment allows safe navigation of any curved canal
Available Sizes
19 2
15 4
20 4
350 rpm
25 4 21/25/31
2.5 Ncm
30 4
35 4
KNOW
MORE 18
REFLECTYS
Universal Composite for anterior and posterior restorations
Advantages Packging
REFLECTYS FLOW
Universal composite uid
Advantages Packging
KNOW
19 MORE
TOTAL C-RAM
Self-etching and self-adhesive resin cement- special ceramic
Advantages
Packging
TOTALCEM
Self-etching and self-adhesive resin cement- Special metal
Advantages
Packging
KNOW
19 MORE
PURE OFFICE
Professional intracanal tooth whitening kits
Advantages
Packaging
MTA BIOREP
Bioceramic repair cement
Advantages
Packaging
KNOW
19 MORE
MTA BIOSEAL
Bioceramic permanent root canal obturation cement
Advantages
Packaging
OBTURYS
Permanent root canal obturation cement
Advantages
Packging
KNOW
19 MORE
DENTOCORE BODY
Core build-up and post cementation composite material
Advantages
Packaging
1 automix 9 gm syringe +
10 mixing tips + 10 thin intraoral
tips + 10 extra thin intra oral tips
DENTOCROWN HD
Temporary restoration material
Advantages
Packaging
KNOW
19 MORE
Gutta Percha & Absorbent Paper Points
KNOW KNOW
MORE MORE
Sizes: F1, F2, F3, Assorted Sizes: F1, F2, F3, Assorted
Excellent radiopacity Sterile
Length marked Length marked
24
Helios 600
Intraoral Scanner
Lighter
198gm, one of the most lightweight
scanners in the market, well-balanced,
ergonomically designed and easy to carry.
Faster
With Helios 600 you can take a full arch scan
in less than 30 seconds.
Smarter
AI technology filters the soft and moving
tissues, o ering users a smooth scanning
experience and generating a natural-looking
treatment outcomes.
More accurate
As one of the most accurate scanners in the
market, Helios 600 has reached the
state-of-the-art accuracy level- the average
deviation of a in-vivo full arch scan is
around 20μm.
KNOW
25 MORE
Helios 600
Intraoral Scanner
L
16mm x 14mm
Not only a comprehensive
S
intraoral scanner,
but also an intraoral camera! 12mm x 12mm
Removable scanner tip-
2 optional sizes
26
Plug & Scan with Helios 600!
Online 3D viewer
Full-arch 20.0μm
22 x 18mm (L)
Tip Tip size (Front part)
18.6 x 16.7mm (S)
Length 1.8m
Connectivity
Type USB 3.0
27
HyperLight
Portable X-ray Unit
Subject
Penumbra Detector
HyperLight
E ect of focal spot size
28
Designed with Safety in Mind
2.5 Exposures
of HyperLight =
(average length of exposure
for D-speed=0.50s)
Specifications
29
Comparative Data for Whole Body Exposure
1.00mSv General Public Dose Limit (Excluding Natural Background & Medical Care)
0.16 – 0.37mSv Range of Exposure for Dental Personnel Using Conventional X-rays 2
0.12mSv NOMAD Average Exposure Using NOMAD with F-Speed Film or Digital Sensor 4
1
Standards for Protection Against Radiation, 10 CFR 20 (US Federal Standards), 1994 (see also NCRP Report No. 116) | 2 NCRP Report no. 160 (National Council
on Radiation Protection and Measurements), p 211-212 | 3 “Estimated Cosmic Radiation Doses for Flight Personnel,”Feng YJ et al, Space Medicine and Medical
4
Engineering, 15(4) 2002, p 265-269 | Normalized average assumes 7,200 exposures per year, and the average length of exposure for D-Speed=0.50 seconds,
F-Speed=0.25 seconds, Digital Sensor=0.20 seconds. Distance: 20cm from the focal spot.
30
NanoPix
Intraoral X-ray Sensor
Unique Design
Ergonomic design
Cupped cable connection ensures
comfortable finger positioning
4.4mm
AED Technology
From Chest Radiography
Compatible with almost all DC & AC X-Ray
generators
Digital images are captured automatically
when the sensor detects X-Ray
KNOW
31 MORE
Specification (available in 2 sizes)
NanoPix 1 NanoPix 2
AD Conversion (bit)
25.4*36.8*4.4
16
30.4*41.9*4.4
16
IP68
Data Interface USB 2.0 USB 2.0 Ingress
Protection
Protection IP68 IP68 Against
Solids
Against
Liquid
3s to complete entire
Step 3: View Image Step 4: Generate ‘Report’ imaging process
50000+ Exposures
with no quality loss
Smart Software
Easy to install Faster image acquisition & better quality images
User-friendly interface Optional image preference
32
NanoPix-E 1.3
Intraoral X-ray Sensor
22 mm
Average Size 30 mm
of Molar
Specifications
Detector Technology : APS CMOS
Scintillator : CsI
Pixel Matrix : 1200*1600
Theoretical Resolution : 25lp/mm
True Resolution : 20lp/mm
Active Area (mm) : 22.5*30
Mechanical Size (mm) : 27.5*38*4.8
Data Interface : USB 2.0
33
E-connect
Cordless Endomotor
KNOW
MORE 34
E-pex
Apex Locator
Display
Value 12 09 00 -3
Meaning The corresponding scale It indicates that the It indicates that the It indicates that the
value is 2, indicating the distance from the apex endo file has root canal file has
distance from the apex is about 1.5mm reached the apex exceeded the
is about 2mm apex
Alarm Beep alarm sound for a Beep alarm sound Uninterrupted Very rapid beep
long time interval interval becomes short long beep alarm sound
KNOW
35 MORE
E-connect + E-pex
A Auto Start 3
Apical 3
Apical Screen Cast/
& Stop 2
1 Reverse 2
1 Slow Down Mirroring**
KNOW
MORE 36
E-xtreme
Taking it to the E-xtreme
Smaller | Lighter | Quieter than ever
360° contra-angle
340° rotation
Regular
head & neck
Specifications
Weight : 99 gram
Torque range : 0.5 Ncm-4.0 Ncm
Power supply : 100 V-240 V
Frequency : 50 Hz / 60 Hz
Output : DC 5 V/ 1 A
KNOW
37 MORE
AirPex
Wireless Apex Locator
KNOW
MORE 38
E-connect S
Endomotor with Built-in
Apex Locator
Apex Locator
Apical control with rotary instruments
Manual canal measurement
Multi-frequency technology with high accuracy
& precision
Apex locator flash bar with zoom-in function
Working Modes
FWD - Clockwise Continuous Rotation ATC - Adaptive Torque Control
REV - Anti-clockwise Continuous Rotation
Torque Below Pre-set Limit Torque Reaches Pre-set Limit Torque Below Pre-set Limit
REC - Reciprocation Movement
First-in-class cordless open system motor with
adjustable angles of rotation ranging from Forward Rotation Reciprocation Forward Rotation
30° to 370° for reciprocation as per user's need. (ATC Mode Active)
KNOW
39 MORE
Motorturbo
Long Lasting Brushless Electric Motor
with Cooling System
Forward/ Reverse
Speed Adjustment
Specifications
KNOW
MORE 40
E-ASP 1
High-Speed Hand-piece
Specifications
41
Ultra X
Cordless Ultrasonic
Activator
In Action
Cavitation E ect: It is the process of formation of millions
of gas bubbles in the irrigation solution. These bubbles
grow in size, oscillate in di erent directions & explode into
the liquid, producing powerful cleaning action
Acoustic Streaming: It is a unidirectional flow of liquid
produced by ultrasonic waves. Movement of tip produces
special e ect called acoustic turbulence which
accelerates the movement of liquid inside the root canal
Indications
Smear Layer Removal: E ective in removal of smear
layer and unplugging of dentinal tubules
Dentin Chips Removal: Ultrasonic agitation forms
suspension of residual dentinal chips and tissue remnants
with irrigant and facilitates their easy removal
Biofilm Disruption: Ultrasonic cavitation disrupts the
biofilm and helps to reduce bacteria load in the canal
Cleaning of Complex Anatomy: Ultrasonic activation helps
irrigants to flush into undetected or un-instrumented canal
anatomy like isthmus, fins, lateral canals, apical
ramification etc. Also helps to remove vapour lock
Key Features
KNOW
MORE 42
X Pro
UltraPack
Fast
Down Pack Device
Temperature Range
Wide temperature range of 90° to 300°
Five memory programs to customize temperature and cut-o time as per obturation material
used or any other intended use of the device
Experience Ergonomics
360° start/stop ring allows holding the device in any angle comfortable for you
Left- right handed operation
Comfortable grip, light in weight
Powerful Battery
Highly e cient 2600 mAh Li-ion battery 15 minute turbo charge to 30% battery
Direct Plug & Play- In case of low battery, use the device directly with adaptor
Specifications
Heating Time : 0.2 seconds for 200° C Charging Time : 2 hours to complete charge
0.5 seconds for 250° C Operating Time : 4 hours of continuous
Cooling Time : 2 seconds for cooling operation at 300°C
KNOW
43 MORE
X
UltraFill
Fast
Motorized Back-ll
Highly Flexible
23 Gauge 25 Gauge
Large Small Highly Durable
Motorized GP Flow
Provides consistent flow of GP at desirable rate
Precludes voids and makes obturation homogeneous
Eliminates hand fatigue that resulted from earlier gun type devices
Comprehensive Display
T 1 2 0 0 oC Three customizable memory programs - T1 to T3 GP flow rate- Low, Medium, High
GP 80%
Specifications
Heating Time : 20 seconds to 200° C Hexagonal Wrench : Use the wrench to bend the
Charging Time : 4 hours to complete tip, rotate the tip and clean
charge the device
KNOW
MORE 44
Curing Pen
4 LEDs Curing Light
Technical Parameters
Dimension :
24*21*230(mm)
Net Weight 109g:
Lens Size 11mm:
Power Supply :
>1200 times,
3 Sec Maximum light intensity
Light Intensity : 1000 mw/cm , 1500 mw/cm ,
2300 mw/cm , 600 mw/cm ( detect mode )
Smart Controller : Keeps light output consistent
Chip
Wavelength : 385-515 nm
410nm 470nm 3 Blue, 1 Violet, 10w LED
385 400 420 440 460 480 500
1000
0 5 10 15 20 Time(s)
1000
KNOW
45 MORE
Curing Pen-E
3 LEDs Curing Light
Technical Parameters
Dimension : 19 x 16.5 x 7.5cm
Net Weight : 120g
Lens Size : 8mm
Power Supply : >1200 times,
3000 mw/cm , 3 Sec
Light Intensity : 3000 mw/cm
(Maximum Light Intensity)
Spectral Range : 380-515 nm
Features
Working Modes
P1 P2 P3
Normal Mode High Mode Ultra Mode
Light Intensity: 1200mw/cm2 Light Intensity: 2000mw/cm2 Light Intensity: 3000mw/cm2
Time Setting: 5-40 Sec Time Setting: 1s, 3s, 5s, 10s Time Setting: 1s, 3s, 5s
P4 P5
Pulse Mode Light Intensity (mw/cm2) Ramp Mode Light Intensity (mw/cm2)
1200 1200
KNOW
MORE 46
UltraMint & UltraMint Pro
All round Ultrasonic Scaler
Scaling | Periodontic
& Endodontic
1
6
7
8
9
10
KNOW
47 MORE
Soft Perio Power for Ultimate Comfort
*Applicable for
Autoclavable plastic box-
2 tips*6, universal wrench*1, Satelec type handpiece*1
all tips from
Eighteeth
6
700ml
600ml
500ml
900ml
makes it convenient for formulating liquid.
400ml
300ml
200ml
100ml
0ml
48
Brilliance Loupes
Flip-up Loupes
Specifications
Magnifications : 3x
Working Distance : 350mm, 400mm, 450mm, 500mm
Field of View : 68mm, 76mm, 84mm, 92mm
Depth of Field : ≥90mm, ≥100mm, ≥115mm, ≥135mm
Net Weight : 71g
KNOW
49 MORE
Softouch
Surgical Headlight
Super Light
Top Class Light Source
Touch Control Design and Stepless Dimming
Short touch to turn on/ o the light, long press to adjust
steplessly the brightness
Safe to Use
High-level short-circuit & open-circuit protection
Specifications
KNOW
MORE 50
J1 & J1 PLUS Patented Bur-Lock Technology Handpiece
Triple Water Spray Push-button Type The Global Unique Super Torque Cutting
(Separated Water & Air) Patent Technology
Specification J1 Plus J1
KNOW
51 MORE
J45 Patented Bur-Lock Technology Handpiece
Specification J45
KNOW
MORE 52
J5 LED Handpiece 2.0
German Bearing Zero-retraction System, Triple Water Spray New Lamp Beads Can Work
Zero Pollution (Separated Water & Air) at Higher Temperatures
Specification J5
KNOW
53 MORE
Ultrasonics
Unique Design
Water Port
Medical-Grade Stainless Steel
KNOW
MORE 54
Resin Based Dental Restorative Material
Neofill™ Ultra resin based restorative material is visible light cured composite based on
BIS-GMA resin & inorganic fillers with average particle diameter of 1.40 microns. The
composite is high strength, abrasion resistant, highly radiopaque, esthetic with high
gloss polishability and excellent color stability.
Indications
Direct restorations of class I to V cavities
Restoration of deciduous teeth
Packaging
Kit- 4 x 4.5gm Syringes (A1, A2, A3, B2),
3 ml 5th Gen Bonding Agent Bottle,
3gm Neoetch Gel Syringe, 15 Brush Tips,
1 Brush Holder, 5 Dispensing Tips, 1 Mixing Pad
Refill- 4.5gm Refill Syringes (A1, A2, A3, B2)
KNOW
55 MORE
Resin Based Dental Restorative Material
Highly polishable, 67% filled, esthetic composite used for all types of cavity
preparations. Neofill™ Flowable has a nominal particle size of 0.7 micron. Easy to polish
to a high luster. Has high compressive strength as well as low shrinkage, resists wear
and staining. Radiopaque for easy identification in radiographs.
Indications
Restorative therapy for mini-cavities of all types
Small Class I and II fillings in areas not subjected to masticatory forces
Classes III, IV, V restorations
Small repair of direct and indirect restorations as per suitable bonding protocols
Packaging
Kit- 4 x 2gm Syringes (A2, A3, A3.5, B2), 20 Dispensing Tips
Refill- 2gm Refill Syringes (A2, A3, A3.5, B2)
KNOW
MORE 56
A-Silicone Impression Material
KNOW
57 MORE
A-Silicone Impression Material
Technical Data
Base- Green
Color Orange Blue
Catalyst- White
Packaging
Putty- 1x 400gm Base, 1x 400gm Catalyst
Light Body- 2x 78gm Light Body Cartridges,
12 Mixing Tips, 12 Intra-oral Tips SAVE
Bite Registration- 2x 78gm Bite Registration UPTO
58
C-Silicone Impression Material
Features
Good flowability and rigidity
Good visibility- the color contrast of the putty & light body ensures better
impression interpretation
High impression accuracy and precision
High tear strength- minimizes the risk of the impression tearing while removing
from the patient’s mouth
Balance between the working and setting time
Biocompatible- allows to use safely on patients with damaged mucosa
High dimensional stability even after disinfection
Good final hardness- ensures accurate model
Pleasant taste- mint flavor & odor
KNOW
59 MORE
C-Silicone Impression Material
Indications
Fixed and removable prostheses
Crowns, bridges, onlays, and inlays
Complete dentures
Technical Data
Packaging
Putty- 1500gm Light Body Tube- 140gm
Catalyst- 70gm
60
Alginate Impression Material
Description
Neoalgin is a high precision alginate impression material for detailed reproduction
of dental impressions.
Features Advantages
Colour change pattern: Non-chromatic Elastic impression
(no colour change) Optimum dimensional stability
Sky blue colour High precision for detailed
Spearmint flavor for high acceptance reproduction of dental
Dust-free formulation anatomy
Thixotropic
Normal working and setting time
Simple and fast mixing without bubbles
Suitable for manual or automatic mixing
Safe disinfection
KNOW
61 MORE
Alginate Impression Material
Key Specifications
Mixing Time 60 sec Time in Mouth 60 sec
Working Time 30 sec Total Working Time 2 min 30 sec
Indications
Removable prosthesis
Study models
Temporary crown & bridges impression
Antagonist models in the fixed and removable prosthesis.
Storage
After opening the pack, store the Neoalgin alginate powder in airtight container.
The container has to be stored at a temperature of 5-27 °C.
After every usage always close the container.
For dispensing Neoalgin always use dry scoop and dry mixing bowl.
Store in cool and dry place.
62
Glass Ionomer Cement- Luting & Lining
Luting & Lining glass ionomer cement. Powder contains mixture of Silica and fluorides of aluminum,
calcium & sodium. Liquid contains polyacrylic acid and copolymer in water.
Indications
Used for cementation of metal or porcelain fused to metal crowns, bridges, inlays
Cementation of stainless steel crowns
For cementation of orthodontic appliances retained with stainless steel crowns
Cementation of orthodontic bands
As Base or liner under restoration
Features
Less technique sensitive Good wettability provides good marginal seal
Long shelf life Low solubility makes it insoluble in the oral
Robust bottle cavity
Fluoride releasing Chemical Adhesion to both tooth structure
Free-flowing liquid provides
(enamel, dentin) and metal
smooth paste and good consistency
Radiopaque makes post-operative diagnosis
Odor-free
Good color match easy
Good biocompatibility and non-irritant Cost-e ective
to the tissues Thin film thickness provides easy seating
High Mechanical strength of crown
Technical Specifications
Mixing Time: 30sec Working time: 2min Setting time: 2min 30sec
KNOW
63 MORE
Universal Restorative Glass Ionomer Cement- High Strength
Compressive
Strength
230 MPa
Universal restorative glass ionomer cement. Powder contains mixture of Silica and fluorides of
aluminum, calcium & sodium. Liquid contains polyacrylic acid and copolymer in water
Indications
Restoration of deciduous teeth. Restorations of Class III, V, and limited
Core build-up Class I cavities.
For atraumatic restorative treatment Used in lamination/sandwich technique
Features
Less technique sensitive Good wettability provides good marginal seal
Long shelf life Low solubility makes it insoluble in the oral cavity
Robust bottle High flexural strength reduces the risk of
Fluoride releasing restoration fracture
Free-flowing liquid provides smooth Chemical adhesion to both tooth structure
paste and good consistency (enamel, dentin) and metal
Odor-free Radiopaque
Good biocompatibility and nonirritant Cost-e ective
to the tissues Film thickness
High mechanical strength
Technical Specifications
Mixing Time: 30sec Working time: 1min 30sec Setting time: 2min 30sec
KNOW
MORE 64
KNOW
17% EDTA Gel with 10% Carbamide Peroxide MORE
Lubricate Clean
Prevents risk of instrument fracture Carbamide peroxide creates e ervescence
Helps in smooth working of endodontic files e ect with water and sodium hypochlorite
Helps in easy removal of vital and necrotic
Chelate pulp tissue remnant, debris & dentinal flakes
Liquid KNOW
17% EDTA Solution | For Smear Layer Removal MORE
Indications
Surface preparation of canal
Debridement of canal
Smear layer removal
Unclogging of dentinal tubules
Advantages
Removes inorganic substances like dentinal
chips & facilitates their easy removal by
chelation of calcium ions
E ective in removal of smear
layer and unplugging of
dentinal tubules-enhances
adhesion of filling material
like sealer
65
Calcium Hydroxide Paste with Barium Sulphate KNOW
MORE
Radiopaque, Multipurpose Root Canal Filling Material
Indications Advantages
Temporary root canal Premixed Formulation: Saves time and has easy application
filling material Paste Type Consistency: Provides superior control during application
Pulp capping Water Soluble Paste: Helps in easy cleaning and removal from canal
Weeping canals Temporary Filling: Temporary filling material between appointments
High pH: High pH of >12.5 creates unfavourable
Root resorption cases
environment for microbes
High Radiopacity: Helps in radiological examination
KNOW
Calcium Hydroxide Paste with Iodoform MORE
Indications Advantages
Temporary & long term root Non-hardening oil based paste
canal filling material Specially designed dispensing tips
Apexification Easy handling and straight forward application
Pulp capping Radiopaque formulation with barium sulphate
Weeping canals & exudation control Best rheology gives smooth and complete filling
Root resorption cases
Periapical lesions
66
KNOW
37% Phosphoric Acid | For Enamel & Dentin MORE
Indications Advantages
Composite restorations High etching rate
Adhesive cementation of inlays, crowns, bridges, Removes contaminants
veneers, posts & cores, splints, pit and fissure sealing Aids wettability
Bonding of orthodontic attachments (e.g. brackets) Achieves high bond strength
KNOW
Gutta Percha Solvent MORE
Indications
Softening of gutta percha based obturating
materials during the root canal retreatment
procedures
Advantages
100% natural
Non-toxic
Biocompatible
Only 2 drops needed
67
KNOW
Temporary Restorative Material MORE
Indications
Temporary filling material of cavities before
permanent restoration
Cementing material for temporary crowns
Advantages
Self curing in cavity
Excellent adhesion with dentin
High marginal seal
Leak proof formulation
Long lasting
Easy application and removal
KNOW
Micronized Methylene Blue Solution | Canal & Caries Detector MORE
Indications
Use to identify root canal orifices during
endodontic treatment
Helps to detect enamel and dentinal cracks
To detect dentinal fractures
68
KNOW
All Purpose Handpiece Lubrication Spray MORE
Advantages
E ective lubrication and reduced debris collection
Protects from corrosion, reduces friction & wear-rate
increasing the lifespan of the instruments
Applications
500 ml
For high-speed, low-speed dental hand-piece
equipments like air turbine, air motor, heads,
prophy angle/ contra angle etc
100 ml
10 ml
100 gm
100 gm
69
Orikam Healthcare India Pvt Ltd
Gurugram O ice : Mumbai O ce :
3rd Floor, Arogyam Building, OHI Marketing, 4050, Eaze Zone
Subhash Nagar, New Railway Mall, Malad (W), Opp. Rustomjee
Road, Gurugram-122001 (Hr.) Ozone, Mumbai- 400064 (Mh.)
Contact: +91 124 4361189, +91 98212 30028 Contact: +91 98209 57308, +91 63649 87444
The CTA (Controlled Thermal Activation) wire in endodontic files enhances flexibility by allowing the instruments to maintain a balance between rigidity and pliability, which is crucial for navigating curved canals without risk of breakage . Additionally, the off-centered rectangular and triangular cross-section designs reduce the contact area with the canal walls, thereby decreasing friction and enhancing cutting efficiency by focusing force on sharp cutting edges for effective debris removal .
Neoendo S files operate at a speed of 400 rpm and a torque of 2 NCm, allowing for reduced radial wall contact and stress, making them suitable for more delicate canal paths . In contrast, Neoendo Flex files typically operate at 350 rpm and 1.5 NCm , which provides a balance between cutting efficiency and safety by preventing fracture in complex canals. This implies that the Neoendo S files are optimized for flexibility and reduced stress while Neoendo Flex files offer a balance slightly leaning towards cutting efficiency and strength, useful in different clinical scenarios based on canal complexity .
The non-cutting tip design of the Neoendo S rotary file minimizes the risk of apical transportation by allowing the file to glide through the canal path without cutting or altering its trajectory . This feature ensures that the instrument can safely follow the canal path, thereby reducing the risk of perforation or deviation from the natural canal anatomy .
The ergonomic design features in dental loupes, such as ultra-light frames, adjustable magnification levels, and precise inter-pupillary adjustments, significantly enhance user comfort by reducing neck strain and eye fatigue during procedures . These loupes also improve procedural outcomes by providing clearer magnification and more accurate visual details of the treatment area, facilitating precision in complex procedures. This enhanced visibility aids in accurate diagnosis and precise instrumentation, contributing to improved clinical results and practitioner well-being .
Modern dental ultrasonic activators, with features like intelligent control systems, enhance patient safety and treatment efficacy by utilizing cavitation and acoustic streaming to improve cleaning action without excessive mechanical force . The AI-driven system adjusts the pressure and duration of ultrasonic waves based on real-time feedback from the treated surface, thereby reducing the risk of tissue damage while ensuring thorough debridement. This finely-tuned control ensures optimal cleaning efficacy by continuously responding to changes in canal morphology and material interaction without compromising patient comfort .
The E-connect S system offers unique advantages such as adjustable angles of rotation up to 370° in reciprocation mode, enhancing the adaptability of file movement to specific canal shapes, and preventing file separation . The ability to adjust speed and torque settings allows practitioners to tailor the mechanical action of files to specific procedural stages. This includes enhancing cutting efficiency in wider canals while ensuring delicate handling in narrow or curved canals, thus increasing procedural safety and efficiency .
The triangular cross-section in Neotaper files enhances cutting efficiency and reduces the contact area with canal walls, minimizing friction and stress on the file. This cross-sectional design helps in debris removal from the canal, providing an efficaceous cutting action which is crucial for shaping the root canal during endodontic procedures .
Glass ionomer cements, with high dimensional stability and excellent adhesion, offer significant benefits for fixed and removable prostheses by securely bonding to the substrate and reducing microleakage . Their ISO-defined working and setting times provide predictable handling properties essential for clinical efficiency, while their elastic recovery properties minimize stress transmission across the restorations. These attributes, paired with favorable thermal expansion coefficients similar to natural dentine, make them particularly appropriate for use in a wide range of prosthetic applications .
Length and taper indicators on Neoendo endodontic files provide vital information that allows dental clinicians to choose the appropriate file dimension for specific canal anatomies. Single and double-ring taper indicators provide quick visual references for taper size, enabling precise preparation of canals with different dimensions, thus preventing over-instrumentation or under-preparation, which is crucial for maintaining the structural integrity of the canal .
The dual surface thermal treatment enhances the file's cutting efficiency and fracture resistance by optimizing the physical properties across different sections of the file . The S-shaped cross-section minimizes radial contact with the canal walls, reducing fatigue and risk of file separation while maintaining high cutting efficiency. Together, these features contribute to a robust yet delicate balance that improves performance in complex canal shapes and increases longevity and efficiency in clinical applications .