R&S FSH-Z28 Datasheet
R&S FSH-Z28 Datasheet
Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
Spectrum Analyzers, Signal Generators, Oscilloscopes, Power Meters, Network Analyzers
etc from all the major suppliers such as Keysight, Tektronix, Anritsu and Rohde & Schwarz.
We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. We fully test & refurbish equipment in our in-house, traceable
Lab. Items are supplied with manuals, accessories and typically a full no-quibble 1 year
warranty. Our staff have extensive backgrounds in T&M which enables us to deliver
industry-leading service and support. We endeavour to be customer focused in every way
right down to the detail, such as offering free delivery on sales, presenting flexible technical +
commercial solutions and supplying a loan unit during warranty repair, if available.
As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.
We are based in at Oakley, Bedfordshire in the UK from where we supply test equipment
worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own
in-house Lab.
- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our 40GHz in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.
Email: info@[Link]
Web: [Link]
R&S®FSH
Handheld Spectrum Analyzer
The all-in-one handheld platform
year
Test & Measurement
2
R&S®FSH Handheld Interference analysis, geotagging and indoor
mapping
❙❙ Spectrogram measurements with R&S®FSH-K14 and
Channel power measurement. ACLR measurement on a 3GPP WCDMA signal with four carriers.
4
Spectrum emission mask measurement on an LTE signal. Measurement of spurious emissions (spectrum
emission mask)
The R&S®FSH measures spurious emissions of a base sta-
tion using the spectrum emission mask (SEM) function.
Spurious emissions can interfere with adjacent trans-
mit signals, resulting in reduced signal quality and lower
data rates. By means of the SEM function, the R&S®FSH
tests whether the signal lies within the limits defined by
the wireless communications standard. The R&S®FSH
offers a wide range of predefined masks, e.g. for 3GPP
WCDMA, CDMA2000®, WiMAX™, LTE, TD-SCDMA,
WLAN and WiBro. New masks with user-defined settings
can be created and utilized quickly and easily with the
R&S®InstrumentView software.
6
The CDMA2000® code domain power measurement provides an overview For in-depth analysis, the R&S®FSH-K46E option is avail-
of the key signal parameters. able for code domain power measurements. This option
permits the graphical display of the channel power of
occupied and unoccupied channels. The resulting sum-
mary provides an overview of key signal parameters, e.g.
RF channel power, channel power, Rho and EVM. Channel
power is displayed relative to the total power or relative to
the power of the pilot channel.
1)
Available for R&S®FSH with serial numbers ≥ 105000.
NB-IoT
NB-IoT
●●● ●●● ●●●
8
TD-SCDMA time domain power display is available with the The R&S®FSH-K48E measurement application enables fast
R&S®FSH-K48E option. and reliable in-depth analysis of TD-SCDMA/HSDPA sig-
nals. The time domain power display shows the received
power, C/I and composite EVM of each active slot within
the TD-SCDMA subframe. The results are simultaneously
displayed in a table and in a diagram. Display lines and
numbering help the user easily check whether the power
and timing of each subframe meet specifications.
The code domain power display shows the active and in-
active TD-SCDMA codes within the selected frequency
channel. The channel table display shows the main pa-
rameters of the TD-SCDMA and HSDPA channels. The
Sync ID display shows the signals coming from different
base stations.
2)
Not applicable to R&S®FSH13 and R&S®FSH20.
3)
Applicable only to R&S®FSH models with built-in VSWR bridge
(models .23/.24/.28/.30).
Distance-to-fault measurements
The distance-to-fault, caused by a pinched cable or by
loose or corroded cable connections, is determined quickly
and precisely. The built-in threshold function ensures that
only true cable faults, i.e. faults that exceed a tolerance
limit, are listed. This considerably simplifies measurement
evaluation.
Vector voltmeter
The R&S®FSH-K45 vector voltmeter option displays the
magnitude and phase of a DUT at a fixed frequency. There-
fore, the R&S®FSH (models .23/.24/.28/.30) can replace a
conventional vector voltmeter for many applications. Be-
cause the required signal source and bridge are already
Distance-to-fault measurements (DTF). available in the R&S®FSH, costs are saved and the test
setup is significantly simplified, making the R&S®FSH-K45
the right choice for field use. For relative measurements,
the measurement results of a reference DUT are stored at
the press of a button.
Comparison measurements, e.g. between different RF ca-
bles and a reference cable (golden device), can be quickly
and easily performed.
Typical applications:
❙❙ Adjustment of electrical cable length
❙❙ Checking of phase-controlled antennas such as used in
an instrument landing system (ILS) in air traffic control
10
Highly accurate power measurements up to Channel power meter
110 GHz with terminating power sensors This standard function enables the R&S®FSH to mea-
Equipped with the R&S®NRP USB power sensors, the sure channel power without an external power sen-
R&S®FSH becomes a highly accurate RF power meter up to sor at the same accuracy as in spectrum analyzer
110 GHz with a dynamic range from –70 dBm to +45 dBm. mode. The measurement amplitude range goes up
to +30 dBm. The frequency range depends on the
Directional power measurements up to 4 GHz R&S®FSH spectrum analyzer model. The channel
The R&S®FSH-Z14 and R&S®FSH-Z44 directional power bandwidth can be set up to 1 GHz and allows measur-
sensors transform the R&S®FSH into a full-featureddirec- ing all types of signals, including modulated signals
tional power meter for the frequency ranges from 25 MHz such as LTE, WCDMA, etc.
to 1 GHz and from 200 MHz to 4 GHz. The R&S®FSH can
then simultaneously measure the output power and the Pulse analysis with wideband power sensors
matching of transmitter system antennas under operating When equipped with the R&S®FSH-K29 option and
conditions. The power sensorsmeasure average power a R&S®NRP-Z81/-Z85/-Z86 wideband power sensor,
up to 120 W and normally eliminate the need for any extra the R&S®FSH can measure peak power and the main
attenuators. They are compatible with the common GSM/ pulse parameters up to 44 GHz.
EDGE, 3GPP WCDMA, cdmaOne, CDMA2000® 1x, DVB-T
and DAB standards. In addition, the peak envelope power Optical power measurement with optical
(PEP) up to max. 300 W can be determined. power sensor
When attached with an R&S®HA-Z360/Z361 optical
power sensor, R&S®FSH power meter mode reads
out optical absolute power in dBm as well as relative
power in dB.
Pulse analysis with R&S FSH-K29 and R&S NRP-Z81 wideband power
sensors. Optical power measurement.
12
Time and frequency markers can be added during the The mapping feature uses the triangulation technique to
post-analysis stage and for documentation. This long time locate the interferer. Using the R&S®OSM wizard, Open
recording spectrogram allows unmanned recording, col- Street Maps (OSM) can be easily downloaded for use with
lection of activities over a long period and facilitates post- the R&S®FSH.
analysis, which is useful for interference hunting and spec-
trum observation. The tone feature helps users acoustically find the direction
where the interference is coming from without needing to
Interference analysis with R&S®FSH-K15 and constantly look at the map or watch the signal levels.
directional antennas
Equipped with the R&S®FSH-K15 option and a directional The R&S®HE400 is the perfect handheld antenna for in-
antenna such as the R&S®HE400, the R&S®FSH helps net- terference hunting with the R&S®FSH. The antenna mod-
work operators and regulatory bodies to successfully de- ules cover frequencies between 8.3 kHz and 8 GHz and
tect and characterize interfering signals and find interfer- is equipped with GPS and an electronic compass. There
ence sources. is a toggle button on top of the R&S®HE400 handle to
switch on the R&S®FSH preamplifier and a trigger button
In addition to the spectrogram and standard spectrum that can be used to save the screen shot or position coor-
analyzer measurements, interference specific measure- dinates and bearing information. The R&S®HE400 weighs
ments such as carrier to noise (C/N), carrier to interference only 1 kg and has a small footprint, which makes it very
(C/I) and trace mathematics (diff mode) help users to easily handy for interference hunting in the field together with
find, monitor and characterize interfering signals. the R&S®FSH.
Indoor mapping
The indoor mapping function helps users measure indoor
coverage in a simple and reliable way.
Geotagging results display with R&S®FSH-K16. With the indoor mapping option (R&S®FSH-K17), the user
can easily import indoor maps into the R&S®FSH and
record the signal strength distribution in environments
where a GPS signal is not available, such as buildings
or tunnels, while keeping the information of the location
where measurements have been done.
OpenStreetMap (OSM)
OpenStreetMap (OSM) is a user-editable world map that is available
at the following Internet address:
[Link]
14
Measurements of Due to its large frequency range of up to 20 GHz, the
R&S®FSH covers all common wireless communications
services, including GSM, CDMA, W CDMA, LTE, DECT,
The fold-out stand turns the R&S®FSH into a desktop EMC precompliance measurements and channel
analyzer for work in the lab or in service. scan
Equipped with the R&S®FSH-K43 option, the R&S®FSH can
be operated as a receiver for precompliance EMC applica-
tions and monitoring tasks. Measurements are performed
at a predefined frequency with adjustable measurement
time.
The R&S®FSH with fold-out stand for desktop use. In the channel scan mode, the R&S®FSH sequentially
measures the levels at various frequencies defined in
a channel table. The channel tables are generated with
the R&S®InstrumentView software and loaded into the
R&S®FSH. There are predefined tables for a large number
of mobile communications standards and TV transmitters.
CISPR bandwidths of 200 Hz, 9 kHz, 120 kHz and 1 MHz
are available for EMI emission measurements. Peak, aver-
age, RMS and quasi-peak detectors can be selected.
16
AM modulation depth measurements Location of EMC problems
The R&S®FSH measures the modulation depth of an AM- The R&S®HZ-15/-17 near-field probes are used as diag-
modulated signal at the push of a button. The AM modu- nostic tools for locating EMC problems, e.g. on circuit
lation depth measurement function positions one marker boards, integrated circuits, cables and shielding. The
each on the carrier, the upper sideband and the lower side- R&S®HZ-15/-17 near-field probe set is ideal for emission
band, and uses sideband suppression to determine the measurements from 30 MHz to 3 GHz. The R&S®HZ-16
modulation depth. The modulation frequency can be pre- preamplifier improves measurement sensitivity up to
defined to selectively determine the modulation depth of 3 GHz, with approx. 20 dB gain and a noise figure of
a two-tone signal, for example by starting with the 90 Hz 4.5 dB. In combination with the R&S®FSH, the preamplifier
sideband and then moving to the 150 Hz sideband of an and near-field probe set are a cost-effective means
ILS signal. of analyzing and locating disturbance sources during
development.
Measurement of signal distortions caused by
harmonics
The R&S®FSH determines the harmonics of a device under
test, e.g. an amplifier, with the harmonic distortion mea-
surement function. In addition to the graphical display of
the harmonics, the R&S®FSH also calculates and displays
the total harmonic distortion (THD).
18
❙❙ InstrumentView supports the following editors: Remote control via LAN or USB
■■ Transducers The R&S®FSH can be remotely controlled via the USB or
■■ Cable Models
LAN interface and integrated into user-specific programs.
■■ Calibration Kits
The SCPI-compatible remote control commands are acti-
■■ Limit Lines
vated by the R&S®FSH-K40 option. The remote display in-
■■ Channel Tables
cluded with the R&S®InstrumentView software shows the
■■ Standards
R&S®FSH screen in realtime and allows users to operate
■■ Quick Name Tables
the instrument remotely via USB or LAN for training and
■■ AM/FM Limits
presentation purposes.
■■ Wizard Sets
■■ (Indoor) Maps
❙❙ Compatible with
■■ Windows Vista (32/64 bit)
20
Easy configuration of instrument setup. Test report in just a few steps with the R&S®FSH
wizard
When an antenna is installed or a transmit station is com-
missioned, the customer usually requests a test report.
The required measurements are defined in test instruc-
tions. The R&S®FSH wizard makes this procedure easy for
the user and eliminates the need to consult the installa-
tion instructions. The dialog-based wizard guides the user
through the measurements and automatically saves the
results.
Additional connectors (e.g. for LAN and USB) are protected by hinged covers.
22
Front view
RF input
Tracking generator output
Connector for headphones Connector for power sensor
Kensington lock
Screenshot
Cursor keys
4)
Interface integrated into instruments with serial numbers ≥ 105000.
For connecting R&S®NRP-Zxx power sensors and USB sticks.
24
R&S®FSH standard functions
Models .04/.08/.13/.20 Models .14/.18 Models .24/.28 Models .23/.30
TDMA power measurements • • • •
Channel power measurements • • • •
Field strength measurements/ • • • •
measurements with isotropic antennas
Occupied bandwidth measurements • • • •
Frequency settings via channel tables • • • •
Scalar transmission measurements – • • –
Scalar reflection measurements – – • –
Vector transmission (S12) and reflection (S22) measurements – – • •
One-port cable loss measurements – – – •
Channel power meter • • • •
R&S®FSH options
Models .04/.08/.13/.20 Models .14/.18 Models .24/.28 Models .23/.30
Spectrogram measurements R&S®FSH-K14 R&S®FSH-K14 R&S®FSH-K14 R&S®FSH-K14
Interference analysis R&S®FSH-K15 R&S®FSH-K15 R&S®FSH-K15 R&S®FSH-K15
Geotagging R&S®FSH-K16 R&S®FSH-K16 R&S®FSH-K16 R&S®FSH-K16
Indoor mapping R&S®FSH-K17 R&S®FSH-K17 R&S®FSH-K17 R&S®FSH-K17
Receiver mode and channel scan measurements R&S®FSH-K43 R&S®FSH-K43 R&S®FSH-K43 R&S®FSH-K43
Analysis of GSM/GPRS/EDGE transmit signals R&S®FSH-K10 R&S®FSH-K10 R&S®FSH-K10 R&S®FSH-K10
Analysis of WCDMA/HSDPA/HSPA+ transmit signals R&S®FSH-K44 R&S®FSH-K44 R&S®FSH-K44/ R&S®FSH-K44
R&S®FSH-K44E R&S®FSH-K44E R&S®FSH-K44E R&S®FSH-K44E
Analysis of CDMA2000® signals R&S®FSH-K46 R&S®FSH-K46 R&S®FSH-K46 R&S®FSH-K46
R&S®FSH-K46E R&S®FSH-K46E R&S®FSH-K46E R&S®FSH-K46E
Analysis of 1xEV-DO signals R&S®FSH-K47 R&S®FSH-K47 R&S®FSH-K47 R&S®FSH-K47
R&S®FSH-K47E R&S®FSH-K47E R&S®FSH-K47E R&S®FSH-K47E
Analysis of TD-SCDMA/HSDPA signals R&S®FSH-K48 R&S®FSH-K48 R&S®FSH-K48 R&S®FSH-K48
R&S®FSH-K48E R&S®FSH-K48E R&S®FSH-K48E R&S®FSH-K48E
Analysis of LTE FDD signals R&S®FSH-K50 5) R&S®FSH-K50 5) R&S®FSH-K50 5) R&S®FSH-K50 5)
R&S®FSH-K50E R&S®FSH-K50E R&S®FSH-K50E R&S®FSH-K50E
Analysis of LTE TDD signals R&S®FSH-K51 5) R&S®FSH-K51 5) R&S®FSH-K51 5) R&S®FSH-K51 5)
R&S®FSH-K51E R&S®FSH-K51E R&S®FSH-K51E R&S®FSH-K51E
Analysis of NB-IoT downlink signals R&S®FSH-K56 5) R&S®FSH-K56 5) R&S®FSH-K56 5) R&S®FSH-K56 5)
Distance-to-fault (DTF) measurements – – R&S®FSH-K41 R&S®FSH-K41
Vector reflection and transmission measurements – – R&S®FSH-K42 –
(S11, S22, S21, S12)
One-port cable loss measurements – – R&S®FSH-K42 –
Vector voltmeter – – R&S®FSH-K45 R&S®FSH-K45
Power measurements up to 110 GHz see power sensors on page 25
Directional power measurements up to 1 GHz/4 GHz R&S®FSH-Z14 R&S®FSH-Z14 R&S®FSH-Z14 R&S®FSH-Z14
R&S®FSH-Z44 R&S®FSH-Z44 R&S®FSH-Z44 R&S®FSH-Z44
Pulse measurements with power sensor 6) R&S®FSH-K29 R&S®FSH-K29 R&S®FSH-K29 R&S®FSH-K29
Remote control via LAN or USB R&S®FSH-K40 R&S®FSH-K40 R&S®FSH-K40 R&S®FSH-K40
Models
Frequency range Preamplifier Tracking generator Built-in VSWR bridge DC voltage supply
(bias) for port 1/2
R&S®FSH4, model .04 9 kHz to 3.6 GHz • – – –
R&S®FSH4, model .14 9 kHz to 3.6 GHz • • – –
R&S®FSH4, model .24 100 kHz to 3.6 GHz • • • •
R&S®FSH8, model .08 9 kHz to 8 GHz • – – –
R&S®FSH8, model .18 9 kHz to 8 GHz • • – –
R&S®FSH8, model .28 100 kHz to 8 GHz • • • •
R&S®FSH13, model .13 9 kHz to 13.6 GHz • – – –
R&S®FSH13, model .23 9 kHz to 13.6 GHz • • • –
R&S®FSH20, model .20 9 kHz to 20 GHz • – – –
R&S®FSH20, model .30 9 kHz to 20 GHz • • • –
5)
Available for R&S®FSH analyzers with serial numbers ≥ 105000.
6)
R&S®FSH-Z129 required for R&S®FSH4/8/13/20 with serial numbers as indicated in the data sheet.
1)
With carrying handle.
26
Vector network analysis 2)/vector voltmeter 3)
R&S®FSH4 R&S®FSH8 R&S®FSH13/20
Frequency range models .24/.28/.23/.30 300 kHz to 3.6 GHz 300 kHz to 8 GHz 100 kHz to 8 GHz
Output power (port 1) 0 dBm to –40 dBm –
Output power (port 2) 0 dBm to –40 dBm 0 dBm to –40 dBm
Reflection measurements (S11, S22)
Directivity 300 kHz to 3 GHz > 43 dB nominal > 43 dB nominal > 43 dB nominal 4)
3 GHz to 3.6 GHz > 37 dB nominal > 37 dB nominal > 37 dB nominal 4)
3.6 GHz to 6 GHz – > 37 dB nominal > 37 dB nominal 4)
6 GHz to 8 GHz – > 31 dB nominal > 31 dB nominal 4)
Display modes vector reflection and trans- magnitude, phase, magnitude + phase, Smith chart, VSWR, reflection c
oefficient, mρ,
mission measurement one-port cable loss, electrical length, group delay
(R&S®FSH-K42)
vector voltmeter magnitude + phase, Smith chart
(R&S®FSH-K45)
Transmission measurements
Dynamic range (S21) 100 kHz to 300 kHz 70 dB typ. 70 dB typ. –
300 kHz to 3.6 GHz > 70 dB, 90 dB typ. > 70 dB, 90 dB typ. –
3.6 GHz to 6 GHz – > 70 dB, 90 dB typ. –
6 GHz to 8 GHz – 50 dB typ. –
Dynamic range (S12) 100 kHz to 300 kHz 80 dB typ. typ. 80 dB typ. 80 dB
300 kHz to 3.6 GHz > 80 dB, 100 dB typ. > 80 dB, 100 dB typ. > 80 dB, 100 dB typ.
3.6 GHz to 6 GHz – > 80 dB, 100 dB typ. > 80 dB, 100 dB typ.
6 GHz to 8 GHz – 60 dB typ. 60 dB typ.
Display modes vector reflection and trans- magnitude (attenuation, gain), phase, magnitude + phase, electrical length, group delay
mission measurement
(R&S®FSH-K42)
vector voltmeter magnitude + phase
(R&S®FSH-K45)
2)
Available for models .24/.28/.23/.30 only; models .24/.28 require R&S®FSH-K42 additionally.
3)
For models .24/.28/.23/.30 only, requires R&S®FSH-K45.
4)
Only S22 measurements.
28
Designation Type Order No.
Recommended extras: power sensors
Directional Power Sensor, 25 MHz to 1 GHz R&S®FSH-Z14 1120.6001.02
Directional Power Sensor, 200 MHz to 4 GHz R&S®FSH-Z44 1165.2305.02
Universal Power Sensor, 1 nW to 100 mW, 10 MHz to 8 GHz 1), 2) R&S®NRP-Z211 1417.0409.02
Universal Power Sensor, 1 nW to 100 mW, 10 MHz to 18 GHz 1), 2) R&S®NRP-Z221 1417.0309.02
Wideband Power Sensor, 1 nW to 100 mW, 50 MHz to 18 GHz 1), 2) R&S®NRP-Z81 1137.9009.02
Wideband Power Sensor, 1 nW to 100 mW, 50 MHz to 40 GHz (2.92 mm) 1), 2) R&S®NRP-Z85 1411.7501.02
Wideband Power Sensor, 1 nW to 100 mW, 50 MHz to 40 GHz (2.40 mm) 1), 2)
R&S®NRP-Z86 1417.0109.40
Wideband Power Sensor, 1 nW to 100 mW, 50 MHz to 44 GHz (2.40 mm) 1), 2) R&S®NRP-Z86 1417.0109.44
Three-Path Diode Power Sensor, 100 pW to 200 mW, 10 MHz to 8 GHz R&S®NRP8S 1419.0006.02
Three-Path Diode Power Sensor, 100 pW to 200 mW, 10 MHz to 18 GHz R&S®NRP18S 1419.0029.02
Three-Path Diode Power Sensor, 100 pW to 200 mW, 10 MHz to 33 GHz R&S®NRP33S 1419.0064.02
Three-Path Diode Power Sensor, 100 pW to 200 mW, 50 MHz to 40 GHz R&S®NRP40S 1419.0041.02
Three-Path Diode Power Sensor, 100 pW to 200 mW, 50 MHz to 50 GHz R&S®NRP50S 1419.0087.02
Thermal Power Sensor, 300 nW to 100 mW, DC to 18 GHz R&S®NRP18T 1424.6115.02
Thermal Power Sensor, 300 nW to 100 mW, DC to 33 GHz R&S®NRP33T 1424.6138.02
Thermal Power Sensor, 300 nW to 100 mW, DC to 40 GHz R&S®NRP40T 1424.6150.02
Thermal Power Sensor, 300 nW to 100 mW, DC to 50 GHz R&S®NRP50T 1424.6173.02
Thermal Power Sensor, 300 nW to 100 mW, DC to 67 GHz R&S®NRP67T 1424.6196.02
Thermal Power Sensor, 300 nW to 100 mW, DC to 110 GHz R&S®NRP110T 1424.6215.02
Average Power Sensor, 100 pW to 200 mW, 8 kHz to 6 GHz R&S®NRP6A 1424.6796.02
Average Power Sensor, 100 pW to 200 mW, 8 kHz to 18 GHz R&S®NRP18A 1424.6815.02
Recommended extras: adapter cables for power sensors
USB Adapter (passive), for connecting R&S®NRP-Zxx power sensors to the R&S®FSH R&S-NRP-Z4 1146.8001.02
USB Interface Cable, length: 1.5 m (59 in), to connect R&S®NRP sensors to the R&S®FSH R&S®NRP-ZKU 1419.0658.03
Adapter Cable for R&S®NRP-Z8x power sensors and R&S®FSH-Z29 option R&S®FSH-Z129 1304.5887.00
USB Adapter Cable for R&S®FSH-Z14/-Z44, length: 1.8 m R&S®FSH-Z144 1145.5909.02
Optical power sensor and accessories
OEM USB Optical Power Meter (Germanium) R&S®HA-Z360 1334.5162.00
OEM USB Optical Power Meter (filtered InGaAs) R&S®HA-Z361 1334.5179.00
SC Adapter for Optical Power Meter R&S®HA-Z362 1334.5185.00
LC Adapter for Optical Power Meter R&S®HA-Z363 1334.5191.00
2.5 mm Universal Adapter for Optical Power Meter R&S®HA-Z364 1334.5204.00
1.25 mm Universal Adapter for Optical Power Meter R&S®HA-Z365 1334.5210.00
Patch Cord SC-LC SM, SX, length: 1 m R&S®HA-Z366 1334.5227.00
Patch Cord SC-SC SM, SX, length: 1 m R&S®HA-Z367 1334.5233.00
Recommended extras for calibration
Combined Open/Short/50 Ω Load Calibration Standard, for calibrating VSWR and DTF measurements, R&S®FSH-Z29 1300.7510.03
DC to 3.6 GHz
Combined Open/Short/50 Ω Load Calibration Standard, for calibrating VSWR and DTF measurements, R&S®FSH-Z28 1300.7810.03
DC to 8 GHz
Calibration Kit, 3.5 mm male, Open/Short/50 Ω Load/Through combination, 0 Hz to 15 GHz R&S®ZV-Z135 1317.7677.02
Calibration Kit, 3.5 mm female, Open/Short/50 Ω Load/Through combination, 0 Hz to 15 GHz R&S®ZV-Z135 1317.7677.03
Calibration Kit, N male, Open/Short/50 Ω Load/Through combination, 0 Hz to 9 GHz R&S®ZV-Z170 1164.0496.02
Calibration Kit, N female, Open/Short/50 Ω Load/Through combination, 0 Hz to 9 GHz R&S®ZV-Z170 1164.0496.03
30
Designation Type Order No.
Spare parts
Spare USB Cable R&S®HA-Z211 1309.6169.00
Spare LAN Cable R&S®HA-Z210 1309.6152.00
Spare AC Adapter R&S®HA-Z201 1309.6100.00
Spare CD-ROM, with R&S®InstrumentView software and R&S®FSH documentation R&S®FSH-Z45 1309.6246.00
Quick Start Manual for R&S®FSH, printed version, English R&S®FSH-Z46 1309.6269.12
Quick Start Manual for R&S®FSH, printed version, German R&S®FSH-Z47 1309.6269.11
1)
Only for R&S®FSH analyzers with serial numbers ≥ 105000.
2)
For the R&S®NRP-Zxx power sensors, the R&S®NRP-Z4 USB adapter is also required.
3)
Required to charge the battery pack outside the R&S®FSH.
4)
R&S®FSH analyzers with serial numbers ≤ 105000 require an SD memory card for a firmware update.
Warranty
Base unit 3 years
All other items 1 year
Options
Extended Warranty, one year R&S®WE1 Please contact your local
Extended Warranty, two years R&S®WE2 Rohde & Schwarz sales office.
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Rohde & Schwarz is under license.
CDMA2000® is a registered trademark of the Telecommunications Industry Association (TIA-USA).
“WiMAX Forum“ is a registered trademark of the WiMAX Forum. “WiMAX“, the WiMAX Forum logo, “WiMAX Forum Certified“, and the WiMAX Forum Certified logo are
trademarks of the WiMAX Forum.
Regional contact
❙❙ Europe, Africa, Middle East | +49 89 4129 12345
customersupport@[Link]
❙❙ North America | 1 888 TEST RSA (1 888 837 87 72)
[Link]@[Link]
❙❙ Latin America | +1 410 910 79 88
[Link]@[Link]
❙❙ Asia Pacific | +65 65 13 04 88
[Link]@[Link]
❙❙ China | +86 800 810 82 28 | +86 400 650 58 96
[Link]@[Link]
5214048212