0% found this document useful (0 votes)
50 views2 pages

High-Strength Concrete Lintel Guide

The document provides specifications for high-strength prestressed concrete lintels, detailing their applications, loading capacities, and installation requirements. It includes load-span tables with dimensions, weights, and uniform distributed loads (UDL) for various lintel sizes. Important notes emphasize checking loadings, correct installation orientation, and the availability of longer lintel lengths for specific applications.

Uploaded by

wlhuyler
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views2 pages

High-Strength Concrete Lintel Guide

The document provides specifications for high-strength prestressed concrete lintels, detailing their applications, loading capacities, and installation requirements. It includes load-span tables with dimensions, weights, and uniform distributed loads (UDL) for various lintel sizes. Important notes emphasize checking loadings, correct installation orientation, and the availability of longer lintel lengths for specific applications.

Uploaded by

wlhuyler
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PRESTRESSED CONCRETE

HIGH-STRENGTH

APPLICATION IMPORTANT NOTES


Designed to support: • The loading figures published in the load-
• Masonry loads span tables represent the Uniform Distributed
• Uniformly distributed timber floor loads Serviceable Load (UDL) in kN/m which can be
• Uniformly distributed roof loads supported by the lintel without the provision
• Concrete floor loads of structural brickwork/blockwork over. This is
• Attic truss loads known as Independent Design.
• Point loads: compound trusses, steel beams, • Lintel lengths shown greyed out within the
etc load-span table are available in longer
lengths than the maximum clear span would
ALWAYS CHECK LOADINGS AGAINST OUR normally allow. These longer lengths lintels
LOAD-SPAN TABLE should be used over a series of openings
(with intermediate supports) NOT exceeding
INSTALLATION NOTES the maximum clear span and NOT simply
For general installation notes please refer supported at each end (i.e. all 70mm
to page 67. deep lintels must not clear span more than
1800mm).
Additional installation requirements for lintels • Lintels are marked TOP and must be used in
supporting concrete floor units the correct orientation
• Check that the correct lintel has been
installed. ABBREVIATIONS:
• Minimum recommended lintel depth is UDL – Uniform Distributed Load (Serviceable)
140mm in order to absorb the shock loading RM – Resistance Moment (Serviceable)
of concrete floor. Precast flooring units should
be laid on a mortar bed across the whole
wall width and should not be dragged over
supports.

ADVANTAGES
% 01455 272457
If in doubt please contact our
technical department on

• A cost effective, high performance range of


lintels
• Easy to install and suitable for a variety of
applications: internal partitions, external
cavity walls, garages, over services.
HIGH-STRENGTH

• We offer a wide range of lintels from


100 x 70 through to 215 x 215.
• If required, Stressline can schedule and
deliver in house plots.

© Stressline Limited 2016


52
STANDARD 900 1200 1350 1500 1650 1800 2100 2400 2700 3000 3300 3600 4050 4200 100 x 140
LENGTHS (mm) HIGH-STRENGTH
Clear Span (mm) 600 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 3900 100

Weight (Kg/m) 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0

140
UDL (kN/m) 68.7* 40.6 35.0 27.0 21.9 17.7 12.5 9.2 7.1 5.6 4.5 3.7 3.1 2.6

RM (kNm) 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8

*UDL is restricted by shear


Minimum manufactured length is 900mm Maximum manufactured length is 4200mm

STANDARD 900 1200 1350 1500 1650 1800 2100 2400 2700 3000 3300 3600 4050 4200 100 x 215
LENGTHS (mm) HIGH-STRENGTH
Clear Span (mm) 600 900 1050 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 3900 100

Weight (Kg/m) 53.9 53.9 53.9 53.9 53.9 53.9 53.9 53.9 53.9 53.9 53.9 53.9 53.9 53.9

215
UDL (kN/m) 78.5* 63.2 57.4 49.2 43.1 36.9 27.2 21.5 16.7 13.3 10.8 9.0 7.5 6.4

RM (kNm) 14.4 14.4 14.4 14.4 14.4 14.4 14.4 14.4 14.4 14.4 14.4 14.4 14.4 14.4

*UDL is restricted by shear


Minimum manufactured length is 900mm Maximum manufactured length is 4200mm

140 x 140 STANDARD 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200
HIGH-STRENGTH LENGTHS (mm)
140
Clear Span (mm) 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900

Weight (Kg/m) 48.0 48.0 48.0 48.0 48.0 48.0 48.0 48.0 48.0 48.0 48.0 48.0 48.0
140

UDL (kN/m) 67.5* 57.9 52.1 39.2 26.5 18.6 13.8 10.6 8.4 6.7 5.6 4.6 3.8

RM (kNm) 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8 8.8

*UDL is restricted by shear


Minimum manufactured length is 900mm Maximum manufactured length is 4200mm

140 x 215 STANDARD 900 1200 1350 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200
HIGH-STRENGTH LENGTHS (mm)
140
Clear Span (mm) 600 900 1050 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900

Weight (Kg/m) 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4 75.4

UDL (kN/m) 101.2* 81.2 73.5 63.2 46.3 33.2 24.9 19.4 15.4 12.5 10.3 8.6 7.3

RM (kNm) 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8 16.8

*UDL is restricted by shear


Minimum manufactured length is 900mm Maximum manufactured length is 4200mm

215 x 215 STANDARD 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 4050 4200
HIGH-STRENGTH LENGTHS (mm)
215
Clear Span (mm) 600 900 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900

Weight (Kg/m) 113.2 113.2 113.2 113.2 113.2 113.2 113.2 113.2 113.2 113.2 113.2 113.2

UDL (kN/m) 143.0* 112.4* 77.8 51.6 36.5 27.1 20.9 16.5 13.3 10.9 9.0 7.6

RM (kNm) 17.7 17.7 17.7 17.7 17.7 17.7 17.7 17.7 17.7 17.7 17.7 17.7

*UDL is restricted by shear


Minimum manufactured length is 900mm Maximum manufactured length is 4200mm