0% found this document useful (0 votes)
49 views1 page

2 PX 13

This document provides detailed specifications for structural design and fabrication, including dimensions, materials, and coating requirements. It outlines compliance with various Indian standards for construction and design parameters specific to a project in Rampura, Rajasthan. Additionally, it includes notes on tolerances and concrete specifications for foundations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views1 page

2 PX 13

This document provides detailed specifications for structural design and fabrication, including dimensions, materials, and coating requirements. It outlines compliance with various Indian standards for construction and design parameters specific to a project in Rampura, Rajasthan. Additionally, it includes notes on tolerances and concrete specifications for foundations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

1 2 3 4 5 7 8

GENERAL NOTES :-

1. ALL DIMENSION ARE IN MM UNLESS OTHERWISE SPECIFIED.


a 2. DO NOT SCALE THE DWG. ONLY WRITTEN DIMENSIONS SHALL BE a
FOLLOWED.
3. FABRICATION & ERECTION SHALL BE CARRIED OUT IN ACCORDANCE WITH
IS:800 AND IS:802
1NO's-11.5Ø EARTHING HOLE 4. DESIGN LOAD CALCULATION SHALL BE AS PER IS 875.
2NO's-13.5Ø HOLE 2NO's-13.5 HOLE 2NO's-13.5 HOLE
50 FOR M12 BOLT FOR M12 BOLT FOR M12 BOLT 2 NO's-11.5 HOLE 50 25
5. STRUCTURAL DESIGN SHALL BE AS PER IS 801.
FOR M10 BOLT
888 600 200 925 MATERIAL :-

b 1. DIMENSION FOR ALL COLD ROLLED STEEL, HAT, CHANNEL SECTION SHALL b
BE AS PER IS-811.
65

2. STEEL GRADE FOR COLUMNS & BRACING CONNECTING CHANNEL SHALL BE

190
S390GD.
3. STEEL GRADE FOR RAFTER, BRACINGS & PURLINS SHALL BE FY550.
60

4. RAW MATERIAL FOR COLUMN & BRACING CONNECTOR SHALL BE AS PER


EN 10346_2015.
4. RAW MATERIAL FOR RAFTER, BRACINGS & PURLINS SHALL BE AS PER
74 IS:15961 (2012).
2738 5. ALL STRUCTURAL FASTENER SHOULD BE GI GRADE 5.6.
6. MODULE MOUNTING BOLTS SHALL BE STAINLESS STEEL SS304.

VIEW X-X COATING :-

c 1. COLUMNS & BRACING CONNECTING CHANNEL SHALL BE MAGSURE 4.5, c


450GSM.
2. ALL OTHER MEMBERS SHALL BE GALVALUME AZ150 GRADE AND COATING
SHALL BE AS PER IS:15961-2012.

200 100 1338 100 1000


FOUNDATION :-
40

1. ALL CONCRETE MIX M:25 UNLESS OTHERWISE SPECIFIED.

80
2. ALL CONCRETE SHALL BE MACHINE MIXED AND MACHINE VIBRATED.
3. CLEAR COVER TO MAIN STEEL 100MM.

2738 TOLERANCE:-
4NO's-11.5Ø HOLE
1. THICKNESS TOLERANCE AS PER IS: 852-1985.
d FOR M10 BOLT VIEW Y-Y 2. HOLE TO HOLE DISTANCE +/- 1 MM
d
3. EDGE CUTTING +/- 1MM
4. OFFSET +/- 1 MM
5. OVERALL LENGTH +/- 2 MM
6. THE DEVIATION FROM THE ANGLE OF 90 Deg. SHALL NOT EXCEED 1 Deg.

DESIGN PARAMETER :-

1. LOACTION - RAMPURA, HANUMANGARH, RAJASTHAN


2. WIND SPEED - 180KMPH
3. GROUND CLEARANCE - 1000MM
4. TILT ANGLES - 22 DEGREE FIXED.
2 NO's-11.5ØHOLE 5. MODULE MAKE - Renew 545Wp Bifacial
25 50 6. MODULE SIZE - 2278X1134X33.
e FOR M10 BOLT e
1225
A - ISSUED FOR INFORMATION
50

100
B - ISSUED FOR APPROVAL

C - ISSUED FOR CONSTRUCTION

D - AS BUILT
1300

20
VIEW X-X

2
f 190 f

100
2

40

80 BOTTOM COLUMN CL-2


20

100CU40X2
COLUMN CL-1
190CS80X2X20
40

g g
1300

VIEW X-X
Suntrik Solutions

REV. NO. DATE DESCRIPTION MADE CHECK APPROVED DRAWING NAME :


00 18.11.2024 FIRST SUBMISSION NS NS AK COLUMN - CL-1 & CL-2 FOR 2PX26_2PX13
01 14.12.2024 FINAL NS NS AK
h PROJECT NAME : h