0% found this document useful (0 votes)
452 views1 page

Air Compressor Risk Assessment Report

The document is a Hazard Identification and Risk Assessment (HIRA) register for an air compressor job site. It outlines various hazards associated with compressor operation, their potential outcomes, existing control measures, and risk levels. The register emphasizes the importance of safety measures and communication to mitigate risks related to equipment failure and operator safety.

Uploaded by

krishan kant
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
452 views1 page

Air Compressor Risk Assessment Report

The document is a Hazard Identification and Risk Assessment (HIRA) register for an air compressor job site. It outlines various hazards associated with compressor operation, their potential outcomes, existing control measures, and risk levels. The register emphasizes the importance of safety measures and communication to mitigate risks related to equipment failure and operator safety.

Uploaded by

krishan kant
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd

Hazard Identification & Risk Assessment (HIRA) Register

Name of the Job Site: Date :


Equipment: AIR COMPRESSOR Ref. No :

Probability
Population
Hazardous

Risk Level

Action By
Residual
Severity
Additional

Rating

Rating
at risk
Sl Event

Risk
Sub activity Hazard Possible Existing Control Measure Control
No
Outcome Measures

Failure of 1-2
Substandard Equipment, Air Compressors are procured from
Incompatibility 1 4 L L
equipment Bursting of reputed vendors with IS make
Container
Trapping, Unguarded 1-2
Entanglement 1 3 L All rotating parts are guarded L
entanglement rotating parts
1-2 Reinforced hoses are used.
incompatibility, Poor
Bursting of Couplers are used to join the hoses.
1 or degradation Condition of 1 4 L L
Compressor Hose Outlet pressure is controlled by
of materials Hose
Operation quick shut valves.
1-2 Pressure Gauges & Pressure relief
Lack of valves are fitted & Ensured working
communication Excessive Bursting of condition.
1 4 L L
or management pressure Cylinders Regular draining of drain valves to
control avoid corrosion & Condensation of
water.
Lack of Cleaning of 1-2
Workers are educated to avoid
communication body by
Injury 2 2 L using compressed air for body, L
or management Compressed
dress cleaning
control Air.

PROJECT MANAGER SECTION-INCHARGE/SITE ENGINEER EHSM/EHSO

You might also like