SR Series
Spring Return dosing pump
D - mechanical diaphragm
The right dosing choice
SR Series
Type D
Spring Return
Mechanical Diaphragm
Dosing Pumps
MAIN ELEMENTS TO SUPPORT OUR FEATURES
PRODUCTS Mechanical Diaphragm pumps are
suitable for use when:
Versatility
Different diaphragm sizes are available
- The dosed liquid contains small
amounts of suspended solids
- The dosed liquid contains a toxic
solution
- A drip proof/air tight application is
to suit different applications, starting required
from 4 until 574 l/h - High pressure is not required
Reliability
The high degree of accuracy and
Each pump is fitted a standard
gearbox reduction system and with a
vertical mounted B14 shaped electric
motor in accordance with UNEL-MEC
specifications.
reproducibility with high quality
materials selected make the mechanical The motor power range is from 0.18
diaphragm SR series to assure the Kw up to 0.37 KW as the European
maximum reliability. standard: 3 phase voltages of 230/400V
@ 50/60Hz, 4 pole and 1 phase voltages
Quality
The best performance for the
of 230/50/60 Hz or 110/60 Hz.
As motors conform to UNEL-MEC
specifications, there are many
alternative option available, including
applications is achieved by optimal different voltages, insulation class and
selection of material and diaphragm special explosion proof versions.
design.
The gearbox is a standard wormwheel
reduction system with all bearings
supported within a fully lubricated
gearbox.
The mechanism for variation of the
stroke length a positive stroke spring
return that is operated by an eccentric.
SR Series
Type D
PUMPING HEADS Stroke adjustment can be carried out:
Pumping heads are made in standard - Manual: by a linear micrometer screw
executions: S.S. 316, PVC and PP. - Electrical: via servo motor with
4-20 mA signal upon request
A wide range of other materials like interface PROFIBUS or other BUS
HASTELLOY, ALLOY, PTFE, PVDF are - Pneumatic: by a pneumatic servo
according to the liquid to be dosed. control with signal from 3 to 15 PSI
Standard liquid handled maximum
temperature MULTIPLE HEADED PUMPS
- 60° C with S.S. 316 pump head Different multiple heads units are
- 40° C with PVC pump head available on request.
Jacketed pump head for either Each pumping element has independent
cooling or heating are available to suit adjustment while running or at
requirements. standstill.
DIAPHRAGM “D” series Mechanical Diaphragm
There are made in PTFE / NBR pumps are available in different sizes:
- D 50 N Stroke lengh 5 mm
SUCTION AND DISCHARGE - D 100 N Stroke lengh 10 mm
CONNECTIONS - D 101 N Stroke lengh 10 mm
Normally are threaded, but they can be - D 121 N Stroke lengh 12.50 mm
supplied also flanged.
For these four types, different
All the pumps have a ball valve diaphragm sizes are available to suit
standard: single and double balls by the different applications for capacity and
function of the diaphragm diameter or pressure.
the material execution.
STROKE ADJUSTMENT
Flow rate adjustment is possible while
running or at standstill. The movement
of the diaphragm is based on a precise
reciprocating gearbox, which provides
an exact volumetric displacement.
Spring Return
Mechanical Diaphragm
Dosing Pumps
SOME STANDARDS EXECUTIONS FOR MECHANICAL DIAPHRAGM PUMPS
EXECUT. PUMPHEAD VALVE (ball) VALVE SEATS DIAPHRAGM VALVES GASKETS
11 S.S. 316 S.S. 316 S.S. 316 PTFE/NBR FPM
12 PP/FRV PYREX PP/FRV PTFE/NBR FPM
13 PVC PYREX PVC PTFE/NBR FPM
16 PVC S.S. 316 PVC PTFE/NBR FPM
17 PP S.S. 316 PP PTFE/NBR FPM
23 PVDF PYREX PVDF PTFE/NBR FPM
FPM = fluoroelastomer S.S 316 = stainless steel 316 C.O. = Chromium Oxide PP/FRV = polypropylene + glass fibber
Difference executions on request
Glossary and numbering system to identify pumps type
D 100N 70/ B 11 DV
1ST group 2nd group 3rd group 4th group 5th group 6th group
“D” series Reduction ratio group
Diaphragm diameter Materials in touch with Not standard-special
Mechanical diaphragm Stroke length (N° of strokes/min)
in mm the fluid code
dosing pump F(1/24) B (1/12)
In case of pumps supplied without motor add: W/M
GENERAL OVERALL DIMENSIONS
D050 D100 D101 D121
A 57 57 68 68
B 90 90 100 100
C 70 70 65 65
D 75 75 73 73
E
E 375 375 410 410
F 90 90 90 90 H
G 75 75 75 75 I
H 115 115 125 125
I 65 65 65 65
G
F
O
D
L 7 7 7 7
M 130 130 170 170
L
N 33 33 33 33
O 80 80 78 78 A B C N
General dimensional quote are indicative and adverted to the maximum acceptable pump dimension
SR Series
Type D 050N
TECHNICAL CHARACTERISTICS
Reducer ratio Capacity (*2) Max Press. Kg / cm2 Connections Net Weights Kg
SPM (*1) L/1’ L/h Kg/cm2 (*3)
Motor ø mm Stroke (*4)
Pump type
(*1) Features Diaphrag. Lenght
SS 316+ PVC-
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz SS 316 PP+FV PVC SS 316
PVC+PP PP+FV
I 35 42 0,066 0,08 4 4,8
Kw
F 58 70 0,116 0,140 7 8,4 0.18
D-050N-30 14 // 10 3 Ph 30 11
C 96 116 0,191 0,230 11,5 13,8
~1400
B 116 139 0,233 0,270 14 16,8 rpm
1/2”
or 5 8
I 35 42 0,233 0,280 14 16,8 G.m.
Kw
0.18
F 58 70 0,400 0,480 24 28,8
D-050N-50 10 1 ph 50 12
C 96 116 0,683 0,820 41 49,2 ~1400
rpm
B 116 139 0,816 0,970 49 58,8
(*1) Piston’s strokes number during 1 minute with 4 poles installed motor (~1400 rpm 1’)
I = Reducer ratio 1 : 40 = 35 strokes at 50 Hz / 42 strokes at 60 Hz
F = Reducer ratio 1 : 24 = 58 strokes at 50 Hz / 70 strokes at 60 Hz
C = Reducer ratio 1 : 14,5 = 96 strokes at 50 Hz / 116 strokes at 60 Hz
B = Reducer ratio 1 : 12 = 116 strokes at 50 Hz / 139 strokes at 60 Hz
(*2) The indicated capacity value is subject to change due to the working pressure, dosed liquid, viscosity and
installation asset.
(*3) Different ranges of connections are available on request
(*4) The weight is approximate and it is the value of the pump fitted with a totally enclosed fan- cooled outdoor motor.
(5) The pumps can be supplied with accessories if requested
(6) The pumps are epoxy coated RAL 7030
Spring Return
Mechanical Diaphragm
Type D 100N
TECHNICAL CHARACTERISTICS
Reducer Ratio Capacity (*2) Max Press. (*3)
Connections (*4) Motor ø mm Stroke Net Weights (*5)
Pump type SPM (*1) L/1’ L/h Kg/cm2
(*1) Features Diaphrag. Lenght
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz SS 316 PVC SS 316 PVC SS 316 PVC
I 35 42 0,75 0,9 45 54
F 58 70 1,25 1,50 75 90
D-100N-70 5 1/2” G.m. 70 11 8
C 96 116 2,06 2,50 124 150
B 116 139 2,50 3,00 150 180
I 35 42 1,15 1,38 69 82,8
F 58 70 1,91 2,30 115 138 Kw
D-100N-90 3 0.18 90 12 8
C 96 116 3,16 3,83 190 230
3 Ph
B 116 139 3,83 4,59 230 276 or
3/4” G.m. Kw 10
I 35 42 1,56 1,87 94 112,3 0.18
1 ph
F 58 70 2,60 3,12 156 187,2
D-100N-105 ~1400 105 12 8.5
C 96 116 4,30 4,96 258 298 rpm
B 116 139 4,96 5,95 298 357,6
1,5
I 35 42 1,78 2,12 106 127,4
F 58 70 2,95 3,54 177 212,4
D-100N-120 1” G.m. 120 14 10
C 96 116 4,86 6,23 292 374
B 116 139 6,23 7,47 374 448,8
(*1) Piston’s strokes number during 1 minute with 4 poles installed motor (~1400 rpm 1’)
I = Reducer ratio 1 : 40 = 35 strokes at 50 Hz / 42 strokes at 60 Hz
F = Reducer ratio 1 : 24 = 58 strokes at 50 Hz / 70 strokes at 60 Hz
C = Reducer ratio 1 : 14,5 = 96 strokes at 50 Hz / 116 strokes at 60 Hz
B = Reducer ratio 1 : 12 = 116 strokes at 50 Hz / 139 strokes at 60 Hz
(*2) The indicated capacity value is subject to change due to the working pressure, dosed liquid, viscosity and installation asset.
(*3) Different ranges of connections are available on request
(*4) The weight is approximate and it is the value of the pump fitted with a totally enclosed fan- cooled outdoor motor.
(5) The pumps can be supplied with accessories if requested
(6) The pumps are epoxy coated RAL 7030
SR Series
Type D 101N
and D 121N
TECHNICAL CHARACTERISTICS
Reducer Ratio Capacity (*2) Max Press. Net Weights Kg
Connections (*3) Motor ø mm Stroke
Pump type SPM (*1) L/1’ L/h Kg/cm2 (*4)
(*1) Features Diaphrag. Lenght
50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz SS 316 PVC SS 316 PVC SS 316 PVC
F 70 84 1,50 1,80 90 108
D-101N-70 C 96 116 2,05 2,46 123 147,6 8 1/2” G.m. 70 11,5 8
B 120 144 2,56 3,07 154 184,8
F 70 84 2,46 2,96 148 177,6 Kw
D-101N-90 C 96 116 3,36 4,04 202 242,4 5 0.25 90 13,5 10
3 Ph
B 120 144 4,25 5,10 255 306 or
3/4” G.m. Kw 10
F 70 84 3,35 4,02 201 241,2 0.25
1 ph
D-101N-105 C 96 116 4,58 5,50 275 330 105 14,5 11
~1400
B 120 144 5,51 6,61 331 397,2 rpm
3
F 70 84 3,75 4,50 225 270
D-101N-120 C 96 116 5,13 6,16 308 369,6 1” G.m. 120 18 12
B 120 144 6,80 8,16 408 489,6
F 70 84 5,36 6,44 322 386,4
Kw
D-121N-120 C 96 116 7,30 9,56 438 525,6 3 1” G.m. 120 12,5 18 12
0.37
B 120 144 9,56 11,47 574 688,8
(*1) Piston’s strokes number during 1 minute with 4 poles installed motor (~1400 rpm 1’)
F = Reducer ratio 1 : 20 = 70 strokes at 50 Hz / 84 strokes at 60 Hz
C = Reducer ratio 1 : 14,5 = 96 strokes at 50 Hz / 116 strokes at 60 Hz
B = Reducer ratio 1 : 11,5 = 120 strokes at 50 Hz / 144 strokes at 60 Hz
(*2) The indicated capacity value is subject to change due to the working pressure, dosed liquid, viscosity and
installation asset.
(*3) Different ranges of connections are available on request
(*4) The weight is approximate and it is the value of the pump fitted with a totally enclosed fan- cooled outdoor motor.
(5) The pumps can be supplied with accessories if requested
(6) The pumps are epoxy coated RAL 7030
Spring Return
Mechanical Diaphragm
Dosing Pumps
Accessoriability
SAFETY VALVES
PULSATION
BACK PRESSURE
DAMPENERS
VALVES
FILTERS
Each metering pump can be supplied with accessories 3.- BACK PRESSURE VALVES
in order to improve the operation and accuracy of the Back pressure valves apply positive discharge pressure
units. to a metering pump system to prevent siphoning and
The benefits of fluid control assure eliminate varying down-stream pressure.
- Increase efficiency and pump life
- Decrease maintenance and operation costs 4.- PULSATION DAMPENER
Metering pumps have a pulsating flow.
The control of fluid dynamics is essential to ensure Both spring return plunger dosing pumps and quick
efficient and safe use of process systems. Uncontrolled closing valves start and stop fluids that are in motion.
fluid in motion can physically destroy. A pumping Spring return plunger dosing pumps derive their
system including the pumping, valves, meters, back pumping action by capturing a given amount of fluid in
pressure valves, inline instrumentation and equipment. a chamber and pushing it out the pump’s discharge.
1.- FILTERS Each pump cycle includes a suction stroke during the
We suggest to install filters (on the suction pipe) to fluid flow is stopped.
keep back impurities that can be presented on liquid to This pumping action produces an acceleration/
be dosed or coming from pipeline system. deceleration of the fluid, creating units of uncontrolled
The use of filters assures a trouble-free dosing. energy, resulting in PULSATION, observed as pressure
spikes.
2.- SAFETY VALVES
Safety valves are designed to protect the pump and Pulsation dampener is required for two reasons:
chemical feed system from over pressure damage - Two reduce high, non- permissible pressure
caused by defective equipment or a blockage in the fluctuations.
chemical feed line. - To create a nearly continuous flow.
Accessories
Safety relief valves
Type Pump capacity Connections
TS-10 200 l/h 3/8” or 1⁄2”
TS-13 400 l/h 1⁄2” G.F
TS-21 1000 l/h 1” G.F
Body PVC or S.S. 316
* S.S. 316 Relief - Safety valve setting pressure: max
40 kg/cm2 (588 Psi) higher pressures are available
on request.
PVC Relief safety valve setting pressure: max 10
kg/cm2 (145 Psi).
For higher setting pressures consult our technical
dept.
Pulsation dampeners
Type: HSTX
Body in S.S.316, composed of two
parts assembled by a special hosing
that under dynamic pressures tends
to close itself.
Diaphragms are compatible to the
liquid used. Built in accordance with
ASME VIII° Div. 1 rules.
Type: HSTPVC
Body in PVC, composed of two parts
assembled by a special hosing that
under hydraulic pressures tends to
close itself.
Maximum temperature: + 50 °C.
Diaphragms are compatible with the
process liquid.
Relief valves
Type Pump Capacity Connections
VSCS-6 90 l/h 1⁄2” G.F
VSCS-10 230 l/h 1⁄2” G.F
VSCS-14 420 l/h 3⁄4” G.F
VSCS-22 1050 l/h 1” G.F
Body PVC or S.S. 316
Diaphragm PTFE/NBR
* Relief valve setting pressure: 0÷20 kg/cm2 the
max value change due the size and materials
G.F.= Cylindrical, Female
Back pressure valves
Type Pump Capacity Connections
VSCC-6 90 l/h 1⁄2” G.F
VSCC-10 230 l/h 1⁄2” G.F
VSCC-14 420 l/h 3⁄4” G.F
VSCC-22 1050 l/h 1” G.F
Body PVC or S.S. 316
Diaphragm PTFE/NBR
* Back pressure valve setting pressure:
0÷2.5 kg/cm2
G.F.= Cylindrical, Female
Polyethylene tanks
suitable to be fitted with metering
pump on its top
Our range of production also includes:
SR series:
Hydraulic diaphragm dosing pumps “B”, “BR” and “SD” types
Mechanical diaphragm dosing pumps “FM” types
Plunger dosing pumps “A” types
PDP series:
Positive displacement dosing pump “AI” and ”SDI” types
High pressure positive displacement dosing pump “AP-AI” types
SDP series:
Solenoid dosing pumps “S” type
Solenoid dosing pumps “GA” type
H series:
Automatic plants for dissolution and preparation of powder polyelectrolytes “HA”, “HB” types
EM series:
Electric mixers for chemical mixing “DMT”, “DEM”, “DRV” and “DRC” types
HEAD OFFICE DOSEURO (UK) LTD.
Via G. Carducci 141 Unit 8, East Road Industrial Estate
XNME0PCDG000G0207
20093 Cologno Monzese (MI) Italy Sleaford, Lincolnshire NG34 7EH
Tel.: +39 02 27301324 Tel.: +44 1529 300045
Fax: +39 02 26700883 Fax: +44 1529 410967
e-mail: info@[Link] e-mail: info@[Link]
[Link] [Link]
The right dosing choice