0% found this document useful (0 votes)
29 views7 pages

Catalogue-Pump Beta

The document describes the solenoid-driven metering pump beta, which is designed for liquid media metering in water treatment and chemical processes, with a capacity range of 0.74 – 32 l/h and a pressure range of 25 – 2 bar. It features a virtually wear-free solenoid drive for long service life, optional external control, and various material combinations for compatibility with different chemicals. Technical specifications, applications, and dimensional drawings are also provided for various pump types and configurations.

Uploaded by

hdendi82
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views7 pages

Catalogue-Pump Beta

The document describes the solenoid-driven metering pump beta, which is designed for liquid media metering in water treatment and chemical processes, with a capacity range of 0.74 – 32 l/h and a pressure range of 25 – 2 bar. It features a virtually wear-free solenoid drive for long service life, optional external control, and various material combinations for compatibility with different chemicals. Technical specifications, applications, and dimensional drawings are also provided for various pump types and configurations.

Uploaded by

hdendi82
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

1.

1 Solenoid-Driven Metering Pumps

1.1.2 Solenoid-Driven Metering Pump beta


Equipped with all the features and properties for superior process management.

Capacity range 0.74 – 32 l/h, 25 – 2 bar

9 All-purpose solenoid-driven metering pump for metering liquid media in water treatment and chemical
processes: Solenoid-driven metering pump beta. Cost-effective, overload-proof and adaptable to existing
signal transducers.

A range of different pump types and material combinations are available for virtually all metering applications.
The virtually wear-free solenoid drive guarantees an exceptionally long service life even under maximum load.

Your Benefits
„ Optional external control via 0/4 – 20 mA and potential-free contacts with pulse step-up and step-down of
64:1 to 1:64
„ Simple adjustment of metering capacity via stroke rate and stroke length
„ Adaptation to existing signal transducers by external control via potential-free contacts with pulse step-up
and step-down
„ Suitable for use with almost all liquid chemicals thanks to the available material combinations: PP, PVDF,
clear acrylic, PTFE and stainless steel
beta b „ Self-bleeding dosing head design in clear acrylic/PVC and PP
„ Virtually wear-free solenoid drive: economical and overload-proof
„ Economical operation with up to 50% energy-savings, thanks to higher pump efficiency
„ Everything in sight and under control: 3 LED display for operating, warning and error messages

Technical Details
„ External control via potential-free contacts with pulse step-up and step-down to adapt to existing signal
transducers of 64:1 to 1:64
„ Optional external control via 0/4 – 20 mA and potential-free contacts with pulse step-up and step-down of
32:1 to 1:32
„ Stroke rate adjustment in 10% increments of 10 – 100% corresponds to 18 – 180 strokes/minute
„ Continuous stroke length adjustment of 0 – 100% (recommended 30 – 100%)
„ Connector for 2-stage level switch
„ Wide-range electrical connection: 100 – 230 V, 50/60 Hz
„ Optional relay module, can also be retrofitted easily and securely
„ Low voltage design 12 – 24 V DC

Field of Application
„ Metering liquid media in water treatment and chemical processes

Low-pressure Metering Technology

01.01.2024 Product Catalogue Volume 1 15


1.1 Solenoid-Driven Metering Pumps

Dimensional drawing of beta, PP material version


Type E F
1000 19.5 179
1000 19.5 179
1000 19.5 179 10.85

1601 19.5 179


1601 19.5 179
1601 19.5 179

M
148 / 153
F
Type K L ØM

95 / 101
1000 71 105.5 70
1000 71 105.5 70
1000 71 105.5 70

E
1601 71 105.5 70
1601 71 105.5 70 10 / 15 41 / 36
1601 71 105.5 70 80 81 / 85 K
92 / 102 131.5 / 135.5 L

Dimensional drawing of beta, Material version PP - dimensions in mm

Dimensional drawing of beta, material version NP


Type E F
1000 19 172
1000 19 172 12.9

1000 19 172
1000 19 172
1000 19 172
1000 19 172

M
148 / 153
F

Type K L ØM
95 / 101

1000 77 105 70
1000 77 105 70
1000 77 105 70
1000 77 105 70
E

1000 77 105 70
10 / 15 41 / 36
1000 77 105 70
80 81 / 85 K

92 / 102 131.5 / 135.5 L

Dimensional drawing of beta, Material version NP - dimensions in mm

Dimensional drawing of beta, material version PV


Type E F
1000 19 179
1000 19 179
29.3
1000 19 179
1000 19 179
Low-pressure Metering Technology

1601 19 179
1601 19 179
M
148 / 153
F

Type K L ØM
95 / 101

1000 71 83 70
1000 71 83 70
6x4
1000 71 83 70
E

1000 71 83 70
1601 71 83 70 10 / 15 41 / 36
1601 71 83 70 80 81 / 85 K
92 / 102 131.5 / 135.5 L

Dimensional drawing of beta, Material version PV - dimensions in mm

16 Product Catalogue Volume 1 01.01.2024


1.1 Solenoid-Driven Metering Pumps

Technical Data
Pump type Pump capacity at Delivery rate at medi- Stroke Connector Suction Average Shipping weight
max. back pressure um back pressure rate size lift* power con-
oØxiØ sumption
PP, NP, PV, TT SS
bar l/hml/ bar l/h ml/ Strokes/ mm m WC W kg kg
stroke stroke min
Metering pumps with non-self-bleeding dosing head
BT4b 1000 ** 10 0.74 0.07 5.0 0.82 0.08 180 6x4 6.0 7.2 2.9 3.6
BT4b 1601 ** 16 1.1 0.10 8.0 1.4 0.13 180 6x4 6.0 9.6 2.9 3.6
BT4b 1602 ** 16 2.2 0.20 8.0 2.5 0.24 180 6x4 6.0 11.2 2.9 3.6
BT4b 0708 ** 7 7.1 0.66 3.5 8.4 0.78 180 8x5 4.0 15.2 3.1 3.9
BT4b 0220 2 19.0 1.76 1.0 20.9 1.94 180 12 x 9 2.0 15.2 3.3 4.4
BT4b 0413 4 12.3 1.14 2.0 14.2 1.31 180 8x5 3.0 15.2 3.1 3.9
BT4b 1604 ** 16 3.6 0.33 8.0 4.3 0.40 180 6x4 5.0 15.2 3.1 3.9
BT5b 0232 2 32 2.96 1.0 36.2 3.35 180 12 x 9 2.0 19.2 5.1 6.6
BT5b 0420 4 17.1 1.58 2.0 19.1 1.77 180 12 x 9 3.0 19.2 4.7 5.8
BT5b 0713 7 11 1.02 3.5 13.1 1.21 180 8x5 3.0 19.2 4.5 5.3
BT5b 1008 10 6.8 0.63 5.0 8.3 0.76 180 8x5 3.0 19.2 4.5 5.3
BT5b 2504 25 *** 2.9 0.27 10.0 5.0 0.46 180 8 x 4 **** 4.0 19.2 4.5 5.3
Metering pumps with self-degassing dosing head (dosing head design 7)
BT4b 1602 ** 10 1.4 0.13 8.0 1.7 0.16 180 6x4 1.8 11.2 2.9 -
BT4b 1604 ** 10 2.7 0.25 8.0 3.6 0.33 180 6x4 1.8 15.2 3.1 -
BT4b 0220 2 16.2 1.50 1.0 18.0 1.67 180 12 x 9 2.0 15.2 3.3 -
BT4b 0413 4 10.8 1.00 2.0 12.6 1.17 180 8x5 1.8 15.2 3.1 -
BT4b 0708 ** 7 6.6 0.61 3.5 7.5 0.69 180 8x5 1.8 15.2 3.1 -
BT5b 0713 7 10.5 0.97 3.5 12.3 1.14 180 8x5 1.8 19.2 4.5 -
BT5b 0420 4 15.6 1.44 2.0 17.4 1.61 180 12 x 9 1.8 19.2 4.7 -
BT5b 1008 10 6.3 0.58 5.0 7.5 0.69 180 8x5 1.8 19.2 4.5 -

* Suction lift with a filled dosing head and filled suction line, with a self-bleeding dosing head with air in the
suction line.
** Pressure-reduced pump types are available in the pressure stages 4, 7 and 10 bar for special applica-
tions, for example in the swimming pool sector. More detailed information is available upon request.
*** 25 bar variant only available with a NP or SS dosing head material.
**** With stainless steel design, 6 mm connector width.

! beta b metering pumps with dosing heads for higher-viscosity media have a 10 – 20 % lower capacity and
are not self-priming with all feed chemicals. G 3/4-DN 10 connector with d 16-DN 10 hose nozzle.

! The vPTFE diaphragm is limited to a maximum operating pressure of 10 bar. The pump capacities of the
metering pumps with vPTFE diaphragm may be 10-20 % lower than those with a standard diaphragm.

All data calculated with water at 20 °C.

Materials in Contact with the Medium


Identity code of Dosing head Connection on suction/ Ball seat Seals Balls
material discharge side
PVT PVDF PVDF PVDF PTFE Ceramic
Low-pressure Metering Technology

PPT Polypropylene PVDF PVDF PTFE Ceramic


PPE Polypropylene Polypropylene EPDM EPDM Ceramic
PPB Polypropylene Polypropylene FKM A FKM A Ceramic
NPT Clear acrylic PVDF PVDF PTFE Ceramic
NPE Clear acrylic PVC EPDM EPDM Ceramic
NPB Clear acrylic PVC FKM A FKM A Ceramic
SST Stainless steel 1.4404 Stainless steel 1.4404 Ceramic PTFE Ceramic
TTT Carbon-filled PTFE Carbon-filled PTFE Ceramic PTFE Ceramic

Metering reproducibility: ± 2% when used according to the operating instructions.

Permissible ambient temperature –10 °C to +45 °C.

Degree of protection: IP 66, insulation class F

9 Scope of supply
Metering pump with mains cable, connector kit for hose/tube connector as per table.

01.01.2024 Product Catalogue Volume 1 17


1.1 Solenoid-Driven Metering Pumps

Identity Code Ordering System for Product Range beta, Version b


BT4b Type Capacity
1000 10 bar 0.74 l/h
1601 16 bar 1.10 l/h
1602 16 bar 2.20 l/h
1604 16 bar 3.60 l/h
0708 7 bar 7.10 l/h
0413 4 bar 12.30 l/h
0220 2 bar 19.00 l/h
Liquid end/valve material
PP Polypropylene/polypropylene
NP Acrylic/PVC
PV PVDF/PVDF
TT PTFE with carbon, PTFE
SS Stainless steel 1.4404/1.4404
Material of seals/diaphragm
T PTFE, diaphragm PTFE coated
F FDA-compliant design, only for PV and SS heads
G EC 1935/2004-compliant design, only for SS
M With vPTFE diaphragm + PTFE valve seats. Design for PV heads only
E EPDM, diaphragm PTFE coated. EPDM ball seats, only for PP and NP heads
B FKM, diaphragm PTFE coated. FKM ball seats, only for PP and NP heads
Liquid end version
0 Non-bleed, without valve spring, for TT, SS and type 0232 only
1 Non-bleed, with valve spring, for TT, SS and type 0232 only
2 With bleed valve, without valve spring , PP, PV, NP only, not type 0232
3 With bleed valve, with valve spring , PP, PV, NP only, not type 0232
4 Design for higher-viscosity media (10-20 % lower metering rate possible), only PVT, types 1604, 0708, 1008, 0413,
0713, 0220, 0420
7 Self-bleeding without bypass, Only for NPT and PVT, not for types 1000 and 1601
Hydraulic connections
0 Standard according to technical data
5 Connector for 12/6 hose, delivery side only
9 Connector for 10/4 hose, delivery side only
Version
0 Standard
Logo
0 With ProMinent logo
Electrical Connection
U 100-230 V, ±10%, 50/60 Hz
M 12 – 24 V DC, Only for BT4b
Cable and plug
A 2 m European
B 2 m Swiss
C 2 m Australian
D 2 m USA
1 2 m, open-ended
Relay
0 No relay
1 Fault indicating relay, normally energised, 1 x changeover contact 230 V - 2 A
3 Fault indicating relay, normally de-energised, 1 x changeover contact 230 V - 2 A
4 As 1 + pacing relay 2 x normally open contacts 24 V - 100 m
5 As 3 + pacing relay 2 x normally open contacts 24 V - 100 mA
Accessories
0 No accessories
1 With foot and metering valve, 2 m PVC suction line, 5 m PE metering line
5 1+ universal control cable
Low-pressure Metering Technology

Control type
0 No lock
1 With lock: manual operation locked when external cable plugged in
Control Variants
0 Without analogue control
A With analogue control 0/4 – 20 mA
Options on request
00 No options

18 Product Catalogue Volume 1 01.01.2024


1.1 Solenoid-Driven Metering Pumps

BT5b Type Capacity


2504 25 bar 2.90 l/h
1008 10 bar 6.80 l/h
0713 7 bar 11.00 l/h
0420 4 bar 17.10 l/h
0232 2 bar 32.00 l/h
Liquid end/valve material
PP Polypropylene/polypropylene
NP Acrylic/PVC
PV PVDF/PVDF
TT PTFE with carbon, PTFE
SS Stainless steel 1.4404/1.4404
Material of seals/diaphragm
T PTFE, diaphragm PTFE coated
F FDA-compliant design, only for PV and SS heads
G EC 1935/2004-compliant design, only for SS
M With vPTFE diaphragm + PTFE valve seats. Design for PV heads only
E EPDM, diaphragm PTFE coated. EPDM ball seats, only for PP and NP heads
B FKM, diaphragm PTFE coated. FKM ball seats, only for PP and NP heads
Liquid end version
0 Non-bleed, without valve spring, for TT, SS and type 0232 only
1 Non-bleed, with valve spring, for TT, SS and type 0232 only
2 With bleed valve, without valve spring, PP, PV, NP only, not type 0232
3 Bleed version, with valve spring, PP, PV, NP only, not type 0232
4 Design for higher-viscosity media (10-20 % lower metering rate possible), only PVT, types 1604, 0708, 1008, 0413,
0713, 0220, 0420
7 Self-bleeding without bypass, Only for NPT and PVT, not for types 1000 and 1601
Hydraulic connections
0 Standard according to technical data
5 Connector for 12/6 hose, delivery side only
9 Connector for 10/4 hose, delivery side only
Version
0 Standard
Logo
0 With ProMinent logo
Electrical Connection
U 100-230 V, ±10%, 50/60 Hz
N 24 V DC, Only for BT5b
Cable and plug
A 2 m European
B 2 m Swiss
C 2 m Australian
D 2 m USA
1 2 m, open-ended
Relay
0 No relay
1 Fault indicating relay, normally energised, 1 x changeover contact
3 Fault indicating relay, normally de-energised, 1 x changeover contact
4 As 1 + pacing relay 2 x normally open contacts
5 As 3 + pacing relay 2 x normally open contacts
Accessories
0 No accessories
1 With foot and metering valve, 2 m PVC suction line, 5 m PE metering line
5 1+ universal control cable
Control type
0 No lock
1 With lock: manual operation locked when external cable plugged in
Low-pressure Metering Technology

Control Variants
0 Without analogue control
A With analogue control 0/4 – 20 mA

01.01.2024 Product Catalogue Volume 1 19


1.1 Solenoid-Driven Metering Pumps

Spare Parts Kits for Solenoid-Driven Metering Pump beta


Spare parts kits for beta b, consisting of:

„ 1 metering diaphragm
„ 1 suction valve assembly
„ 1 discharge valve assembly
„ 1 connector kit
Stainless steel design without suction valve assembly and without discharge valve assembly, with valve seats,
seals and valve balls
Type Materials in Contact with the Order no.
Medium
Type 1000 PPE 1001644
PPB 1001652
NPE 1001713
NPB 1001721
PPT, NPT, PVT 1023107
PVF 1083549
SST 1001729
Type 1601 PPE 1001645
PPB 1001653
NPE 1001714
NPB 1001722
PPT, NPT, PVT 1023108
PVF 1083547
SST 1001730
Type 1602 PPE 1001646
PPB 1001654
NPE 1001715
NPB 1001723
PVT, PPT, NPT 1023109
PVF 1083550
SST 1001731
PVT7, NPT7 1047830
Type 1604 and type 2504 PPE 1039989
PPB 1039987
NPE 1039988
NPB 1039986
PVT, PPT, NPT 1035332
PVF 1083548
PVT4 1035342
SST 1035331
PVT7, NPT7 1047858
Type 0708 and type 1008 PPE 1001648
PPB 1001656
NPE 1001717
NPB 1001725
PVT, PPT, NPT 1023111
PVF 1083564
PVT4 1019067
SST 1001733
PVT7, NPT7 1047832
Low-pressure Metering Technology

Type 0413 and type 0713 PPE 1001649


PPB 1001657
NPE 1001718
NPB 1001726
PVT, PPT, NPT 1023112
PVF 1083551
PVT4 1019069
SST 1001734
PVT7, NPT7 1047833
Type 0220 and type 0420 PPE 1001650
PPB 1001658
NPE 1001719
NPB 1001727
PVT, PPT, NPT 1023113
PVF 1083552
PVT4 1019070
SST 1001735
PVT7, NPT7 1047837

20 Product Catalogue Volume 1 01.01.2024


1.1 Solenoid-Driven Metering Pumps

Type Materials in Contact with the Order no.


Medium
Type 0232 PPE 1001651
PPB 1001659
NPE 1001720
NPB 1001728
PVT, PPT, NPT 1023124
PVF 1083553
SST 1001736

Spare Diaphragms for Solenoid-Driven Metering Pump beta


Materials in Contact With Order no.
the Medium
Type 1000 all materials 1000244
Type 1601 all materials 1000245
Type 1602 all materials 1000246
Type 1604 and type 2504 all materials 1034612
Type 0708 and type 1008 all materials 1000248
Type 0413 and type 0713 all materials 1000249
Type 0220 and type 0420 all materials 1000250
Type 0232 all materials 1000251

Accessories
„ Foot valves for low-pressure metering pumps, see page →137
„ Injection valves for low-pressure metering pumps, see page →139
„ Hoses and pipework for low-pressure metering pumps, see page →196
„ Suction lances and suction assemblies for solenoid-driven metering pumps see page →161
„ Connectors, fittings, connector kits, seals, see page →200

Spare Parts
„ Special valve balls/special valve springs, see page →216

Low-pressure Metering Technology

01.01.2024 Product Catalogue Volume 1 21

You might also like