The document contains detailed specifications for various components related to hydrogen service in a plant, including flow rates, pressures, temperatures, and design conditions. It outlines engineering notes regarding maximum conditions, insulation specifications, and inspection requirements. Additionally, it provides a field type explanation for data input guidelines in the LDT system.

Uploaded by

Mufleh Idris
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
115 views1 page

LDT Sample

The document contains detailed specifications for various components related to hydrogen service in a plant, including flow rates, pressures, temperatures, and design conditions. It outlines engineering notes regarding maximum conditions, insulation specifications, and inspection requirements. Additionally, it provides a field type explanation for data input guidelines in the LDT system.

Uploaded by

Mufleh Idris
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd

LINE NUMBER NORMAL CONDITIONS LINE INFORMATION DESIGN CONDITIONS REF. DWGS.

SERVICE INFORMATION REV


MAX. OPERATING CODE DESIGN EXP

PLANT TRAIN COM. NO. SIZE CLASS MASS VOLUME SOLIDS VAPOUR PRESS. TEMP VISC. DENSITY VELOC. DP EFF. TOTAL NOTE 1 NOTE 2 NOTE 3 TEST NOTE 4 HOLD TRACE INSULATION
P & ID FLUID FROM TO Comments
FLOW FLOW /1000ft LENGTH DP PRESS TEMP PRESS TEMP TEMP PRESS X-RAY TEMP
NPS LBS/HR WT% Vol% PSIG °C cP LB/FT3 FT/SEC PSI FT PSI PSIG °C PSIG °C °C PSIG % REQ'D °C NOTE 5 NOTE 6, 7

Integer (7)
Integer(2) Integer(1) Char(4) Integer(4) Char(5) Char(4) Integer(12) Integer(4) Integer(4) Integer(6) Integer(4) Char(6) Char(6) Integer(6) Integer(4) Integer(6) Integer(4) Integer(6) Integer(4) Integer(6) Integer(4) Integer(4) Integer(6) Integer(4) Integer(4) Char(8) Char(7) Char(30) Char(60) Char(2) Char(1) Char(4) Char(12) Char(2) Char(1) Char(4) Char(12) Char(2) Char(40)
Char(5)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

27 1 H 2001 16 XXXX No No 27-1A-212/5 HYDROGEN 21 H 2001 27 1 H 2002 E


45100 106 ACFS 0 100 340 40 2 Phase 2Phase 107 1.67 700 1.17 420 54

27 1 H 2002 1 1/2 CC2D No IW1.5CA 27-1-A-5/30-1 HYDROGEN 27 1 TP 3 27 1 C 32 E


45100 106 ACFS 0 100 340 40 0.010 0.118 107 1.67 700 1.17 420 54

27 1 H 2002 10 CC2D No IW1.5CA 27-1-A-5/30-1 HYDROGEN 27 1 TP 3 27 1 C 32 E


22550 53 ACFS 0 50 340 40 2 Phase 2 Phase 120 3.63 100 0.36 420 54

27 1 H 2003 10 CC2D 5 ET IW1.5CA 27-1-A-5/34-1 HYDROGEN 27 1 H 2002 27 1 C 50 E


22550 53 ACFS 0 50 340 40 2 Phase 2 Phase 120 3.63 100 0.36 420 54

27 1 H 2004 8 XXXX 5 ETS IW1.5CA 27-1-A-5 HYDROGEN 27 1 TP 20 27 1 H 2001 E


10605 89 ACFS 0 100 350 43 0.09 0.033 76 2.16 200 0.44 420 57

27 1 H 2006 2 1/2 CC2H 5 ET PP1.0CA 27-1-A-30-1 HYDROGEN 27 1 C 33 27 1 E 11B E


22550 30.5 ACFS 0 100 761 121 0.011 0.205 128 7.90 100 0.79 840 135

27 1 H 2007 8 CC2H No No 27-1-A-30-1/32-1 HYDROGEN 27 1 E 11B 27 1 C 41B E


22550 24.5 ACFS 0 100 751 38 0.010 0.256 108 6.62 100 0.66 840 54

27 1 H 2008 8 CG4D 5 ETS WT1.5CA 27-1A-212/39-1 HYDROGEN 21 H 2005 27 1 E 10 E


21950 12.8 ACFS 0 100 393 97 0.013 0.475 41 2.5 700 1.73 470 114

27 1 H 2009 8 CG4D 5 SL1-1-33 WT1.5CA 27-1-A-1 HYDROGEN 27 1 TP 26 27 1 H 2010 E


44100 26.7 ACFS 0 100 383 40 0.011 0.459 87 10.1 100 1.01 470 54

27 1 H 2010 8 CG4D 5 SL1-1-33 WT1.5CA 27-1-A-1 HYDROGEN 27 1 H 2009 27 1 TP 27 E


44100 27.7 ACFS 0 100 383 40 0.011 0.459 87 10.1 100 1.01 470 54

27 1 H 2011 8 CC2H No IW1.5CA 27-1-A-32-1 HYDROGEN 27 1 C 41B 27 1 C 34 E


22550 24.5 ACFS 0 100 750 38 0.010 0.256 108 6.64 100 0.66 840 54

ENGINEERING NOTES:
(1) MAXIMUM CONDITIONS OF COINCIDENT PRESSURE AND TEMPERATURE. (5) SPECIFY ELECTRIC TRACING AS:
l ET ELECTRIC TRACING - NOT STEAMOUT COMPATIBLE
(2) DETERMINE ASME CODE DESIGN CONDITIONS AS PER SPEC L-2 AND ASME B31.1 l ETS ELECTRIC TRACING - STEAMOUT COMPATIBLE
SECTION 101, OR B31.3 SECTION 301. STEAM TRACERS SHALL BE SPECIFIED BY TRACER CODE PER SPEC L-10.
OCCASIONAL OVERPRESSURE IN ACCORDANCE WITH ASME B31.3
PARAGRAPH 302.2.4 (f), OR B31.1 PARAGRAPH 102.2.4, IS NOT ALLOWED.
LINE DESIGNATION TABLE
(6) SPECIFY INSULATION CODE PER SPEC N-6. PIPING DESIGNER SHALL MODIFY
(3) SHOW MAXIMUM TEMPERATURE POSSIBLE DUE TO UPSET, STEAMOUT, ETC. INSULATION CODE ON PIPING DRAWINGS FOR LOCALIZED VARIATIONS,
FOR EXPANSION STRESS CHECK. i.e., HIGH MECHANICAL ABUSE AREAS, FIRE HAZARDOUS AREAS, ETC. H - HYDROGEN

(4) SHOW THE FREQUENCY OF X-RAY INSPECTION REQUIRED FOR BUTTWELDS (7) Insulation to be finalized during detailed design
DWG TYPE PLANT TRAIN SUB DS NUMBER SHT REV
AS DEFINED IN SPEC.W-15. (8) Equivalent Lengths to be confirmed during detailed design
REV. DATE REVISION BY CHK APPD DS 27 01 A 138 83 E

LDT field type explaination

Each field has been defined as a character or integer field.


This field type representation is a guideline for input into the LDT and not actually field type definition within Notia.
Many of these values in Notia are predefined picklist and are therefore not specifically defined as integer or char.