BX243UBX243CU

The installation manual for the BX243U/BX243CU sliding gate operator emphasizes the importance of safety and proper installation procedures to prevent injury or death. It outlines specific installation requirements, safety instructions, and maintenance recommendations, including the necessity for qualified professionals to handle the installation. Additionally, the document details the manufacturer's limited warranty and conditions of use for the gate operator.

Uploaded by

BRAULIO SOFTWARE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views36 pages

BX243UBX243CU

The installation manual for the BX243U/BX243CU sliding gate operator emphasizes the importance of safety and proper installation procedures to prevent injury or death. It outlines specific installation requirements, safety instructions, and maintenance recommendations, including the necessity for qualified professionals to handle the installation. Additionally, the document details the manufacturer's limited warranty and conditions of use for the gate operator.

Uploaded by

BRAULIO SOFTWARE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

AUTOMATION FOR SLIDING GATES

SERIES
BX

INSTALLATION MANUAL
BX243U/BX243CU
IMPORTANT UL-325 SAFETY INSTRUCTIONS
BX Series
It is extremely important that all parties involved in the installation and operation of the gate operator system read and understand
the following warning instructions.

WARNING – To reduce the risk of injury or death:


1. READ AND FOLLOW ALL INSTRUCTIONS.

Pag. 2 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
2. Never let children operate or play with gate controls. Keep the remote control away from children.

3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.

4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates
the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and
retest the gate operator properly can increase the risk of injury or death.

5. Use the emergency release only when the gate is not moving.

6. KEEP GATES PROPERLY MAINTAINED. Read the installation manual and have a qualified service person make repairs
to gate hardware.

7. The entrance is for vehicles only. Pedestrians must use separate entrance.

8. SAVE THESE INSTRUCTIONS.

Instructions regarding intended installation of the gate operator.

A. Install the gate operator only when:

1. The operator is appropriate for the construction of the gate and the usage Class of the gate.

2. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of
4 feet (1.22m) above the ground to prevent a 2-1/4 inch (57.2mm) diameter sphere from passing through the
openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open
position.

3. All exposed pinch points are eliminated or guarded.

4. Guarding is supplied for exposed rollers.

B. The operator is intended for installation only on gates for vehicles. Pedestrians must be supplied with a separate access
opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that
persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.

C. The gate must be installed in a location so that enough clearance is supplied betweehbe employed, and adjacent
structures when openening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.

D. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.

E. For gate operators utilizing Type D protection:

1. The gate operator controls must be placed so that the user has full view of the gate area when the gate is not
moving.

2. The placard provided marked in letters at least 1/4 - in (6.4mm) high with the word “WARNING” and the
following statement or equivalent: “Moving Gate Can Cause Serious Injury or Death” shall be placed adjancent
to the controls.

3. An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed.

4. No other activation device shall be connected.


F. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22m)
above the ground to prevent a 2-1/4 inch (57.2mm) diameter sphere from passing through the openings anywhere in the gate,
and in that portion of the adjacent fence that the gate covers in the open position.

G. All exposed pinch points are eliminated or guarded.

H. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent
structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access area.
Pag. 3 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

I. Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and
where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily
accessible controls shall have a security feature to prevent unauthorized use.

K. FOR GATE OPERATORS UTILIZING A NON-CONTACT SENSOR:

1. See instructions on the placement of non-sontact sensors for each type of application.

2. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while
the gate is still moving

3. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as
the perimeter reachable by a moving gate or barrier.

L. FOR A GATE OPERATOR UTILIZING A CONTACT SENSOR:

1. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as the
leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate.

2. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.

3. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.

4. A hardwired contact sensor shall be located and its wiring arranged so that the communication between the
sensor and the gate operator is not subjected to mechanical damage.

5. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate.
Additionally, if the bottom edge of a swing gate is greater than 6 inches (152mm) above the ground at any
point in its arc of travel, one or more contact sensors shall be located on the bottom edge.

M. A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.

N. All gate operators systems should include safety devices such as reversing edges or photocells in order to provide
added protection. These safety devices should be installed in accordance to the design and application of the system
being installed.

O. A qualified professional installer should install a gate operator system, its safety accessories and should observe these
minimum procedures:

a. Power should be disconnected before installing or servicing a gate operator.


b. All electrical wiring should comply with all local building and electrical codes.
c. All entrapment zones and pinching points should be covered.
d. All safety devices should be tested to assure their proper functionality.
e. The operation of the gate system: operator, controls and safety devices should be reviewed with the end user
or owner, who should be informed of the need for periodic maintenance of the safety and control equipment.
f. All installation operating and safety manuals should be left with the owner.
CAME AMERICAS AUTOMATION, LLC
MANUFACTURER’S LIMITED 3-YEAR WARRANTY

Verification of the warranty period requires copies of receipts or other proof of purchase.
Warranty cannot be honored without proof of purchase. Please retain these records.

Came Americas Automation, LLC (“CAME®”) products are warranted by CAME® against defects in materials and manufacturer
workmanship for a period of thirty-six (36) months from the date of purchase, provided the recommended installation manual and
procedure have been followed. CAME®’s sole obligation under this warranty is limited to repairing or replacing, at our option, any
parts which shall be determined by CAME® to be defective, and is conditioned upon CAME® receiving notice of any such defect
within the warranty period. Claims under this warranty may only be made by a purchaser of CAME® products (the “Customer”).

Pag. 4 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
CAME® reserves the right to make the final determination as to whether there is a defect in the materials and/or workmanship, and
whether or not a product is within the warranty period. CAME® is not responsible for any damages or other costs caused by, or which
may result from installation, handling, non-recommended operation, product abuse, or modifications not authorized by CAME® or for
any damages which may arise out of the use of CAME® products.

CAME® sells its products through authorized distributors. This warranty on CAME® products is NOT VALID if the products have been
purchased from an unauthorized distributor, reseller, online E-tailer ( e.g., E-bay®), or if a product serial number has been altered,
removed, or replaced in any way. To verify that you are buying from an authorized CAME distributor or reseller please
call +1 305-433-3307.

In the case of product failure due to defective material or manufacturer workmanship within the thirty-six (36) months warranty
period, the product will be repaired or replaced (at the manufacturer’s option) at no charge to the Customer, if returned, freight
prepaid, to CAME AMERICAS AUTOMATION, LLC, 11345 NW 122nd Street Medley, Florida 33178.
IMPORTANT: Obtain a Return Goods Authorization (RGA) number before returning item(s) to our facilities by submitting a warranty
claim and request for RGA with our customer service department. Products shipped without an RGA number will not be accepted.
Replacements or repaired parts are covered by this warranty for the remainder of the thirty-six (36) month warranty for the original
product or six (6) months from the date of repair or replacement, whichever is greater. CAME® will pay shipping costs at the ground
transport rate for the return to owner of item(s) repaired under warranty.

The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or the
reinstallation of these parts after repair. Use of any (00021996.doc V.2) components that are not CAME® specified (e.g. batteries, light
bulbs, drive belts, chains or transformers) will void the warranty. This warranty shall be void if damage to the product(s) was due to
improper installation or use, neglet, accident, use of non-CAME® specified or approved components or replacement parts, connection
to an improper power source, tampering, or if damage was caused by lighting, strikes, power surges, wind, fire, floor, insects, or other
natural agents or disasters.

This warranty gives you specific legal rights, and you may also have other rights, which vary from state
to state (or jurisdiction to jurisdiction.) CAME's responsibility for malfunctions and defects in equipment
is limited to repair and replacement as set forth in this warranty statement.

THE CUSTOMER ACKNOWLEDGES AND AGREES THAT THIS WARRANTY IS MADE


EXPRESSLY IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES FOR THE
PRODUCT(S), INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES AND
CONDITIONS OF MERCHANTABLE QUALITY, MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, OR ANY OTHER EXPRESS OR IMPLIED WARRANTY ARISING
OUT OF LAW, STATUTE, USAGE OF TRADE OR COURSE OF DEALINGS.

The warranty hereunder is limited in time to the term of the limited warranty period reflected in this
limited warranty. No warranties, whether express or implied, will apply after the limited warranty period
has expired. Some states do not allow limitations on the term of an implied warranty, so this limitation
may not apply to you.
CAME® DOES NOT ASSUME, AND SPECIFICALLY DISCLAIMS, ANY LIABILITY OR OBLIGATION WHATSOEVER IN THE SALE OF THE
PRODUCT(S), INCLUDING ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, PUNITIVE OR SPECIAL DAMAGES TO YOU OR ANY OTHER
PERSON OR ENTITY, INCLUDING, WITHOUT LIMITATION, ANY LIABILITY FOR THIRD-PARTY CLAIMS AGAINST YOU FOR DAMAGES. THE
CUSTOMER ACKNOWLEDGES THAT THIS LIMITED WARRANTY PROVIDED IN LIEU OF ALL OTHER WARRANTIES AND CUSTOMER’S
WAIVER OF SPECIAL, INCIDENTAL AND CONSEQUENTIAL DAMAGES IS COMMERCIALLY NECESSARY AND REASONABLE, AN ESSENTIAL
AND MATERIAL ELEMENT OF THIS TRANSACTION, AND UPON WHICH BOTH THE CUSTOMER AND CAME® HAVE RELIED AND HAVE HAD
THE OPPORTUNITY TO NEGOTIATE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you. CAME®‘s liability will be no more than the amount you paid for the product that is the subject of a claim.
This is the maximum amount recoverable under this warranty. The limitations in this section shall apply whether or not the alleged
Pag. 5 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

breach or default is a breach of a fundamental or material condition or term, or a fundamental or material breach.

CAME AUTOMATIC GATES UL 325 CLASSES

CLASS DUTY CYCLE BX Series


I Residential Vehicular Gate Operator
Typical use: Home, 1-4 apartment condominium. INTENSIVE X
Limited public access.
II Commerical/ General Access Vehicular Gate Operator
Typical use: Condominiums, hotels, parking lots. INTENSIVE X

III Industrial/ Limited Access Vehicular Gate Operator


Typical use: industrial location, Factory, Loading Dock. INTENSIVE X
No general public access.

IV Restricted Access Vehicular Gate Operator


Typical use: Security area with restricted access. INTENSIVE X
No general public access.

Power Connection
CAUTION

Be sure that the circuit breaker for the line input power is turned off before connecting the input power to the unit.

Warning: CAME SPA is not responsible for researching and complying with local building codes. Be sure to check these codes
before installation.

The installer must use 14AWG conductors and ½” conduit for the power connection.
“IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS”
“CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”
“THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS”

1 Legend of symbols
This symbol tells you to read the section with particular care.
This symbol tells you that the sections concern safety issues.

Pag. 6 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
This symbol tells you what to say to the end-users.

2 Conditions of use
2.1 Intended use
The BX243U/BX243CU operator is designed to power sliding gates in residential and condominium settings.

Do not install or use unless as otherwise shown in this manual.

2.2 Limitations to use

For intensive or condominium use: max gate weight 660lb with max gate length 28 ft.

3 Reference standards
The company CAME cancelli automatici is ISO 9001:2000 quality certified; it has also obtained the ISO 14001 environmental safeguarding
certification. CAME engineers and manufactures all of its products in Italy.
This product complies with the following standards: UL-325 and CSA C22.2 NO.247-92.

4 Description

4.1 Operator

This product is engineered and manufactured by CAME CANCELLI AUTOMATICI S.p.A. in compliance with current safety
standards. The operator is made of a cast aluminium part inside of which operates the irreversible, electromechanical
gearmotor and an ABS plastic lining which holds the electronic card, transformer and battery rack.

4.2 Technical features

Control panel power supply: 120V A.C. 50/60Hz


Operator power supply: 24V D.C.
Draw: 7A max.
Power: 1/4HP
Reduction ratio: 1/50
Thrust: 300N
Max speed.: 12m/min max.
Duty cycle: intensive use
Protection rating: IP54
Insulation class: I
Weight: 26lb

131°F

-4°F
4.3 Description of parts

1) Top cover 12 10
1
2) Motor
3) Transformer
4) Trap door to access manual release of gearmotor
5) Securing plate
6) Securing bolt 14
7) Securing nut and washer
8) ZN5U electronic card
9) Card and battery rack support
Pag. 7 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

2 11
7
NOTE: for BX243U (Rack & Pinion) 3 8
Do Not Include Items: 10, 11, 12, 13, 14
13

NOTE: for BX243CU (Chain - Drive) 4


9
Include Items: 10, 11, 12, 13, 14
5

4.4 Dimensions
4.49”
13 “

4.13”

4.63”
.93”

5.87” 5.87” 6.37”


measurements in inches
11.7” 8.35”

5 Installation
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.

5.1 Preliminary checks

Before installing, do the following:


• Make sure that the gate is stable, and that the castors are in good working order and properly greased.
• The ground rack must be well secured to the ground, entirely above the surface and free of any irregularities that may
obstruct the gate’s movement.
• The upper guide rails must not create any friction.
• Make sure that there is a closing and an opening endstops.
• Make sure that the operator is attached to a solid surface and protected from any impacts;
• Make sure you have a suitable omnipolar cut-off device with contacts more than 1/32” in (3 mm) apart, and independent
(sectioned off) power supply;
• Check that any connections inside the container (that provide continuity to the safety circuit) are fitted with
additional insulation compared to other internal live parts;
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against
mechanical damage.
5.2 Tools and materials

Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and
compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed by the
installer.

Pag. 8 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
BX243CU (Chain - Drive)
Note: A hacksaw is needed for the installation of the BX243CU

5.3 Cable list and minimum thickness

Length of cable Length of cable Length of cable


Connection Type of cable
3 < 32ft 32 < 65ft 65 < 100ft
Control panel power supply 120V 3G x 14AWG 3G x 14AWG 3G x 14AWG
Flashing light 2 x 20AWG 2 x 20AWG 2 x 20AWG
Photocell transmitter UL LISTED 2 x 20AWG 2 x 20AWG 2 x 20AWG
Photocell receiver CABLE/WIRE 4 x 20AWG 4 x 20AWG 4 x 20AWG
Accessories power supply 2 x 20AWG 2 x 20AWG 2 x 20AWG
Safety and control devices 2 x 20AWG 2 x 20AWG 2 x 20AWG
Antenna connection RG58 max. 32ft

Note: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of
the actual power draw by the connected devices and depending on local electrical codes.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power
draw and distances. When connecting products that are not specified in this manual, please follow the
documentation provided with said products.
3
5.4 Standard Installation for BX243U (Rack & Pinion)

1) BX243U assembly
2) Rack 5
3) Antenna 4
4) Keyswitch selector
9
5) Safety photocells
6) Electric cable junction box
7) Mechanical endstops
8) Guide rails 8
Pag. 9 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

9) Sensitive edge 7

5.4 Standard installation for BX243CU (Chain - Drive)

1) BX243CU assembly
2) Chain 5
3) Antenna 4
4) Keyswitch selector
9
5) Safety photocells
6) Electric cable junction box
7) Mechanical endstops
8) Guide rails 8
9) Sensitive edge 7

6
5.5 Securing the plate and installing the assembly the BX243U (Rack & Pinion)

The following applications are only examples, as the space for installing the ratiomotor and accessories varies
according to obstructions. It is thus up to the system installer to select the most suitable solution.
- Dig a pit to the side of the gate (see measurements from diagram).
Prepare the corrugated tubes you will need when making connections coming from the shunt pit.
Note: The number of tubes depends on the type of system and the accessories you will hook up.

Pag. 10 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
1.57”

9.44”

15.74”

12” Conduits for electric


cables

Shunt pit

- Prepare a form box that is larger in size than the securing plate and insert it into the pit. The form box should jut 1 3/4” in (50mm)
above ground level.
Insert an iron grid inside the from box to reinforce the concrete.
Prepare the securing plate, insert the bolts into the holes and lock them using the supplied nuts and washers. Extract the preformed
brackets using a screw driver or a set of pliers.
1.97” in

- Position the plate on top of the grid. Careful! The tubes need to pass through the apposite holes.
To position the plate in relation to the rack please see the measurements on the diagram.
Fill the form box with cement and wait for at least 24 hours for it to solidify.

3.54”

1.97”

4.13”
26
Remove the form box (1), fill the pit around the cement block with soil (2) and unbolt the nuts and washers from the bolts (3). The
securing plate must be clean, perfectly aligned and with the bolt threads completely on the surface.
Insert the electric cables into the tubes until they exit about 15 3/4” in (400mm) (4).

1)
3)

2)
Pag. 11 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

4)

- Remove the cover from the gearmotor by loosening the side bolts, perforate the cable shafts using a screwdriver or a pair of
scissors and position the gearmotor atop the plate. Careful! The electric cables must pass through the cable shafts.

cable shafts

- Lift the gearmotor from the securing plate by about 3/16” to 25/64” in (5 to 10mm) by using the threaded steel-levelling feet to
allow any later adjustments between the pinion and the rack.

Levelling feet
- The following illustrations for the securing the rack, are just examples of applications. It is up to the installer to choose the best solution.
- Releasing the gearmotor (see paragraph on manual release). Rest the rack on the gearmotor pinion.
Weld or secure the rack to the gate along its entire length.
- To assemble the rack modules, use an excess piece of rack and place it under the joining point, then block it using two C-clamps (3).
Note: If a rack is already in place, then just adjust the pinion-to-rack distance.

Pag. 12 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
- Open and close the gate manually and register the pinion-to-rack distance using the threaded steel-levelling feet (for vertical
adjusting) and the slotted holes (horizontal adjusting). This prevents the weight of the gate from bearing on the operator.

Rack
1/32” - 5/64” in

Slotted holes

Coupling
distance

Pinion
Levelling feet

Once adjustments are finished, secure the assembly using the nuts and washers.
Insert the cover after performing the adjustments and settings on the electronic card.
5.6 Adjusting the mechanical stops for BX243U (Rack & Pinion)
Adjusting the opening mechanical stops:
- With the motor in release mode, fully open the gate. Activate the opening-microswitch, turning the white cam clockwise. Secure
the cam by turning the screw.

Opening-microswitch
Pag. 13 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

White cam

Adjusting the closing endstop:


- With the motor in release mode, fully close the gate. Activate the closing-microswitch, turning the red cam
counter-clockwise. Secure the cam by turning the screw.

Red cam

Closing-microswitch

5.7 Manually releasing the gearmotor the BX243U (Rack & Pinion)

- insert the customised key and turn it couter-clockwise. Open the trap door and pull on the release lever.

1
5.5 Securing the plate and installing the assembly for BX243CU (Chain - Drive)

The following applications are only examples, as the space for installing the ratiomotor and accessories varies
according to obstructions. It is thus up to the system installer to select the most suitable solution.
- Dig a pit to the side of the gate (see measurements from diagram).
Prepare the corrugated tubes you will need when making connections coming from the shunt pit.
Note: The number of tubes depends on the type of system and the accessories you will hook up.

Pag. 14 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
1.57”

9.44”

15.74”

12”

Conduits for electric


cables

Shunt pit

- Prepare a form box that is larger in size than the securing plate and insert it into the pit. The form box should jut 1 3/4” in (50mm)
above ground level.
Insert an iron grid inside the from box to reinforce the concrete.
Prepare the securing plate, insert the bolts into the holes and lock them using the supplied nuts and washers. Extract the preformed
brackets using a screw driver or a set of pliers.
1 3/4” in

- Position the plate on top of the grid. Careful! The tubes need to pass through the apposite holes.
To position the plate with respect to the gate, follow the measurements on the drawing.
Fill the form box with cement and wait for at least 24 hours for it to solidify.
1.97”

2.17”
- Remove the form box, fill the pit around the cement block with soil and unbolt the nuts and washers from the bolts. The securing
plate must be clean, perfectly aligned and with the bolt threads completely on the surface.
Pag. 15 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

5.6 Fixing the chain for BX243CU (Chain - Drive)

- At a height of 4.33” in (110 mm) from the anchoring base surface, perforate the extremities of the gate sides to fix the hook brackets.


.43

” .43
.18
4.33”

1 1.1
8”

mm
30

- Insert the bushings into the holes and fix the brackets using screws and washers (see drawing).
- Fix the chain via the hooks onto the two brackets. If the chain is too long, cut off the excess length.

Pag. 16 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
- Note: If needed, fix the extension bracket on the back part of the gate to allow the gate a full run.

- Adjust the tightness of the chain using the outer nut. Then fix it using both inner nuts.
5.7 Installing the unit for BX243CU (Chain - Drive)
- Insert the electrical cables into the tubes until about 15/3/4” in (400 mm) stick out the other end. Remove the gearmotor cover
by unscrewing the side screws.
Pag. 17 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

- Perforate the cable shaft using a screwdriver or scissors. Remove the upper pulley support by unscrewing the four screws.

cable shafts

- Position the gearmotor on top of the plate. Warning! The electrical cables must pass through the cable shafts.
Align the pulley with the chain.
- Adjust the coupling with the built-in adjusting system using steel, rifled feet (vertical adjustments) and the slots (horizontal
adjustments).

(vertical adjustments) (horizontal adjustments)

Pag. 18 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
Levelling feet Slotted holes

- Once adjustment is complete, fix the unit using the nuts and bolts. Insert and fix the pulley support.

- The cover needs to be inserted and fixed after any adjustments and settings on the electrical card.
5.8 Manually releasing the gearmotor for BX243CU (Chain - Drive)

- Insert the customised key and turn it counter-clockwise. Open the trap door and pull on the release lever.

2
Pag. 19 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

5.9 Adjusting the mechanical stops for BX243CU (Chain-Drive)


Adjusting the opening mechanical stops:
- With the motor in release mode, fully open the gate. Activate the opening-microswitch, turning the white cam clockwise. Secure
the cam by turning the screw.

Opening-microswitch

White cam

Adjusting the closing endstop:


- With the motor in release mode, fully close the gate. Activate the closing-microswitch, turning the red cam
counter-clockwise. Secure the cam by turning the screw.

Red cam

Closing-microswitch
6 Control board
6.1 General description

Use 120V A.C. to power the electronic card using the L-N terminals, at a max 50/60Hz frequency.
Use 24V D.C. to power the command devices and accessories. Careful! The accessories cannot exceed 37W of overall power.
The card is fitted with an amperometric device which constantly monitors the motors drive. When the gate runs into an obstacle, the
amperometric sensor immediately detects the overload on the drive and so inverts the gates movement:

Pag. 20 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
- Re-opens the gate while is in closing-mode (1) - it recloses the gate while is in opening-mode.

(1) Warning: After 3 obstacle detections, the gate stops when in opening-mode and excludes automatic-closing mode; to regain
movement press the command button or use the remote control.

All connections are protected by quick-fuses – see table.

FUSE TABLE ZN5U


To protect: Fuse:
Motor 8A-F
Control board (line) 3.15 A-F
Accessories 1.6 A-F
Command devices 1A-F

The card handles the following functions:


- Automatic closing after an opening command.
- Obstacle detection when gate is still at any point.
- Constant monitoring of photocell operations.
- Opening/closing.
- Opening/closing in maintained action mode.
- partial opening.
- total stop.
After detecting an obstacle, the photocells will trigger:
- The reopening of a closing gate.
- The partial stop of a moving gate followed by its automatic closing (if this function has been selected).
After an obstacle is detected the sensitive edges will:
- Reopen the gate if it is closing;.- Close the gate if it is opening.
Apposite trimmers regulate:
- The automatic closing’s running time.
- The partial opening.
- The amperometric device’s detection sensitivity, in both normal and brake modes.
- the speed of both the normal gate run and the brake mode run.
6.2 Main components

1) Power supply terminals 1 3 14 4 2 13


2) Endstop terminals
3) Motor terminals
L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
4) Encoder terminals
5) Accessory fuse
6) Card fuse L N L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
7) Button for memorising the radio code LINE FUSE C. BOARD CONTROL
230V=1.6A-F 12
8) Radio-code signalling LED indicator 120V=3.15A-F
FUSE
1A-F ZN5
9) 120V-power signalling LED 11 ZN5U
Pag. 21 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

1
C1

10) Control and signalling LED group C3


C7
C8 10
11) Function selector DIP switch MOTOR FUSE ACCESSORIES
BX243=8A-F FUSE
ON
PWR

12) Socket for connecting the remote BX246=10A-F 1.6A-F


1 2 3 4 5 6 7 8 9 10
9
control’s radiofrequency card
13) Antenna terminal 16 15 5 6
PROG.

14) Accessories’ and command device’s 7


terminals + SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -

15) Motor fuse


16) Line fuse 17
17) Setting trimmer
8

6.3 Electrical connections

Gearmotor, endstop and encoder

Factory electrical connections for left-hand installations

24V (DC) motor


with encoder
White
COM Orange Brown
Green
NC White

COM Orange
Red
NC Red Green

Opening microswitch Closing microswitch

FC FA F + E - M N

To change installation handside, invert the gearmotor (M-N) and (FA-FC) endstop phases.

COM

NC White

COM
Red
NC Red Green

FC FA F + E - M N
Power supply for accessories

Cable lug with bolt and washer for connecting to earth.

Terminals for powering the following accessories:


- 24V A.C. normally
- 24V D.C. when the emergency batteries are working
Maximum allowed power: 37W

120V (a.c.) Power, 50/60Hz frequency

Pag. 22 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
+ -

10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS

L N
Command and control devices

Stop button (N.C. contact)


- Gate stop button. Excludes automatic closing. For motion to resume,
press the command button or the remote control button.

Key selector and/or partial opening button (N.O. contact)


- Partial gate opening for pedestrian access.

Key selector and/or command button (N.O. contact)


- Gate opening and closing command.
By pressing the button or turning the selector key, the gate
inverts its movement or stops depending on which the
settings on the DIP switches.

10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS

Warning devices

Open-gate status light (contact range: 24V


WARNING DEVICE
– 3W max)
(contact power: 24V A.C. - 25W max)
- Signal that gate is open; turns off when
After the encoder has detected an
gate is closed.
obstacle in the same direction twice
running, the card activates the warning
device and blocks the radio transmitter
for 5 minutes.
After 5 minutes, the alarm is
deactivated and the radio transmitter
restored (the PROG Led goes OFF).
10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS To restore the radio transmitter before
5 minutes, press the total stop key (the
PROG Led goes OFF).
Safety devices
DIR photocells
RX TX
«partial stop» (N.C.) contact
- Compliant with UL325 standards and CSA STD C22.2
No.247 for input safety devices such as photocells. Gate
stops if moving and automatically shuts (if this functions
has been selected).
Pag. 23 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS

DIR photocells
RX TX
(N.C.) contact for «re-open during closing phase»
- Compliant with UL325 standards and CSA STD C22.2
No.247 for input safety devices such as photocells.
If contact is opened, while gate is closing, the gate
inverts its direction.

10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS

RX DOC photcells TX
«partial stop» (N.C.) contact + - NO C NC + -

10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS

RX DOC photcells TX
«Open while closing» (N.C.) contact
+ - NO C NC + -

10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS
DF DF with DFI connections
«Open while closing»(N.C.) contact monitor card
- Compliant with UL325 standard and
CSA STD C22.2 No. 247 for input safety
devices such as sensitive edges. During
gate closing, opening the contact C NO NC 24V 12V 0V C NO NC C NO NC
causes inversion of movement until
gate is fully open; if not used, short
circuit contact 2-C7.

Pag. 24 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS

DF with DFI connections


DF
monitor card
«close while opening» (N.C.)contact
- Compliant with UL325 standard and
CSA STD C22.2 No. 247 for input safety
devices such as sensitive edges. During
C NO NC 24V 12V 0V C NO NC C NO NC
gate opening, opening the contact
causes inversion of movement until gate
is fully close; if not used, short circuit
contact 2-C8.

10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS

6.4 Electrical connection to operate the photocells safety test


(DOC) (DIR)

+ - + -
N.C.
N.O.

C.

FUSIBILE 200mA

+ -
10 2 TX C NC TX
TX 2

+ - -
10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS

At each open/close command, the card checks the photocells efficiency.


Any problems with the photocells will cause the (PROG) Led to flash
on the electronic card, which cancels any commands from the radio
transmitter or push-button. 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS
Electrical connection to operate the photocells safety test:
- The transmitter and receiver, must be connected as shown in the diagram.
- Set DIP switch 7 to ON to activate the test.
IMPORTANT:
When the safety test function is activated, the N.C. contacts:
- If unused – are to be excluded on their relative DIP switches (see chapter 9 “selecting functions”).
ZN5U 1
C1
C3
7 Settings C7
C8
MOTOR FUSE ACCESSORIES
ON
BX243=8A-F FUSE PWR
BX246=10A-F 1.6A-F
1 2 3 4 5 6 7 8 9 10

PROG.

+ -
Pag. 25 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -

SETTING TRIMMER LIST:


- «A.C.T.» Sets the waiting time while open. Once this time has elapsed, closing automatically takes place. The waiting time
may be set from 1 to 150 seconds.
- «PAR.OP.»Sets the gates partial opening. By pushing the partial opening button connected at 2-3P, the gate opens depending on
+ E- «SLOW-S.» FC FA F
the length of the gate.
Sets the amperometric sensitivity that controls the force generated by the motor during slow down; if the force
exceed the set level, the system intervenes by inverting the direction of motion.
- «RUN S.» Sets the amperometric sensitivity that controls the force generated by the motor during movement; if the force
exceeds the set level, the system intervenes by inverting the direction of motion.
- «SLOW V.» Sets the gates final opening/closing phase slow-down speed.

+ E- «RUN V.»- FC FA F
Sets the gates opening/closing motion speed.

8 Warning Led
CONTROL

ZN5 5 7 2 C1 C3 C7 C8 TS + E - FC ListFAwarnings
- «1»
F of the command and safety devices’ control leds:

Red led. Normally off.

ZN5U
Led PWR
Shows activation of the PARTIAL STOP button.
1 - «C1» Yellow led. Normally off.
5 7 2 C1 C3 C7 C8 TS + C1E - FC FA F Shows that there are obstacles between the photocells (which are in OPEN
Led PROG
C3 WHILE CLOSING mode).
CONTROL - «C3» Yellow Led. Normally off.
C7
ZN5 C8
Shows that there are obstacles between the photocells (which are in PARTIAL
STOP mode).
ZN5U
PWR
- 1«C7»
C1
C3
Yellow Led. Normally off.
Show obstacles detected by the sensitive edge (which are in OPEN WHILE
C7 CLOSING mode).
C8
- «C8» Yellow Led. Normally off.
PWR Shows obstacles detected by sensitive edge (which are in CLOSE WHILE
OPENING mode).
2 3 4 5 6 7 8 9 10
- «PWR» Green led. Normally on.
Shows that card is properly powered.
PROG. PROG.

Note: If programing LED is flashing, check unused Photocells terminals and proceed to
“Jump” between 2 and C1, C3, C7 or C8.
V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -

+ A.C.T. - - «PROG» Red Led. Normally off.


When the transmitter is activating, it turns on or flashes.
FUSE
1A-F ZN5
9 Function selector ZN5U 1
C1
C3
C7
C8
CCESSORIES Default Setting
ON
FUSE PWR
1.6A-F ON
1 3 4 5 6 7 8 9 10
2
ON

OFF PROG.1 2 3 4 5 6 7 8 9 10

Pag. 26 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
1 ON - Automatic Closing - The automatic closing timer activates at the end of the opening gate run. The pre-set time is adjustable,
+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -
and is in any case conditioned by the activation of any safety devices, and does not activate after a total safety “stop” or
during a blackout.
2 ON - "Open-stop-close-stop" function with [2-7] button and radio transmitter (fitted with inserted radiofrequency card).
2 OFF - "Open-close" function with [2-7] button and radio transmitter (fitted with inserted radiofrequency card).
3 ON - "Open only" function with [2-7] button and radio transmitter (fitted with inserted radiofrequency card).
4 OFF - Not used. Leave OFF.
5 OFF - With BX-243U/243CU motor.
5 ON - With BX-246U/246CU motor.
6 ON - Maintained action - The gate works by keeping button pressed (one 2-3P opening button , and one 2-7 closing button).
7 ON - Functioning of the photocells’ safety test - Allows the card to check the efficiency of any safety devices (i.e. photocells)
after every opening or closing command.
8 OFF - Total stop - This function stops the gate and then excludes any automatic closing cycle; to set in motion again, use either
the keypad or transmitter. Insert the safety device in [1-2]; If unused, set DIP switch to ON.
9 OFF - Opening during closing - If the photocells detect an obstacle during gates closing, the gate motion is inverted until fully
opened; connect the safety device to terminals [2-C1]; if unused, set DIP switch to ON.
10 OFF - Partial stop - Gate stops when an obstacle is detected by the safety device; once the obstacle is removed, the gate remains
still or closes if automatic closing is activated. Connect the safety device to terminal [2-C3]; if unused, set the DIP switch
to ON.

Note: If terminals C7 and C8 are not use, please proceed to “Jump” then between 2 C7 and 2 C8.

10 Programmation to save gate-run and decelerations adjustments


Do the adjustment by making the operator execute a complete
opening/closing manoeuvre
The control board automatically registers the gate-run adjustments
with opening and closing decelerations.
L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F

L N L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
7 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
LINE FUSE C. BOARD
230V=1.6A-F
To save the adjustment, positionFUSE
120V=3.15A-F dip 6 in ON and press PROG button
1A-F until the signalling led stays on.
CONTROL BOARD L1T
7 26 M NRe-position
10 11 E1 1 the 2 dip
3P 5 in 7OFF2 C1 C3 C7 C8 TS + E - FC FA F L2T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
ZN5
1
C1
Note:C.You
BOARD
need to reposition the dip in OFF to avoid that the reactivation of power C3
C6
supply after a blackout provokes a new
adjustment
FUSE
1A-F
while executing
MOTOR FUSE ACCESSORIESthe first manoeuvre. L N L2T L1T
ON
C7
0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
BX243=8A-F FUSE CONTROL BOARD PWR
BX246=10A-F 1.6A-F
Dip 6 in ON ZN5
1 LINE FUSE
1 2 3 4 5 6 7C18 9 10 C. BOARD
C3 230V=1.6A-F FUSE
C6
C7
120V=3.15A-F PROG 1A-F CONTROL BOARD
USE ACCESSORIES PROG.

ZN5
ON 1
A-F FUSE PWR C1
A-F 1.6A-F C3
1 2 3 4 5 6 7 8 9 10 C6
C7
+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. - MOTOR FUSE ACCESSORIES
ON
BX243=8A-F FUSE PWR
PROG.
BX246=10A-F 1.6A-F
1 2 3 4 5 6 7 8 9 10

+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. - LED on Dip 6 in OFF PROG.

+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -


11 Activating the radio command
Antenna
Connect the antenna’s RG58 cable to the apposite terminals.
Pag. 27 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F

L N L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
LINE FUSE C. BOARD CONTROL
230V=1.6A-F
120V=3.15A-F
FUSE
1A-F ZN5
ZN5U 1
C1
C3
C7
C8
MOTOR FUSE ACCESSORIES
ON
BX243=8A-F FUSE PWR
BX246=10A-F 1.6A-F
1 2 3 4 5 6 7 8 9 10

PROG.

Radiofrequency card
+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -

Insert the radio frequency card into the electronic card AFTER DISCONNECTING THE POWER (and disconnecting any batteries).
Note: the electronic card picks up the radiofrequency card on when it is running on power.

AF Card
L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F

L N L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
LINE FUSE C. BOARD
230V=1.6A-F FUSE
120V=3.15A-F 1A-F CONTROL

ZN5
1
C1
C3
C6
C7
C8
C7
MOTOR FUSE ACCESSORIES
ON
BX243=8A-F FUSE
ZN5U
PWR
BX246=10A-F 1.6A-F
1 2 3 4 5 6 7 8 9 10

PROG.

Electronic card
+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -

Transmitters

TOP
TOP-432NA • TOP-434NA
ing
ag
ck
pa
on
o ns
cti
tru
ns
ei
Se
Memorization

Keep pressed the PROG button on the electronic card. The LED will flash.

Pag. 28 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F

L N L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
LINE FUSE C. BOARD
230V=1.6A-F FUSE
120V=3.15A-F 1A-F CONTROL

ZN5
1
C1
C3
C6
C7
C8
C7
MOTOR FUSE ACCESSORIES
ON
BX243=8A-F FUSE
ZN5U
PWR
BX246=10A-F 1.6A-F
1 2 3 4 5 6 7 8 9 10

PROG.

PROG
+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -

Flashing LED

Press the button of transmitter to memorise. The LED will stay on to signal memorisation.

L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F

L N L2T L1T 0 17 26 M N 10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8 TS + E - FC FA F
LINE FUSE C. BOARD
230V=1.6A-F FUSE
120V=3.15A-F 1A-F CONTROL

ZN5
1
C1
C3
C6
C7
C7
C8
MOTOR FUSE ACCESSORIES
ON
BX243=8A-F FUSE
ZN5U
PWR
BX246=10A-F 1.6A-F
1 2 3 4 5 6 7 8 9 10

PROG.

+ SLOW V. - + RUN V. - + SLOW S. - + RUN S. - + PAR.OP. - + A.C.T. -

LED on
12 Safety instructions
7 Prescrizione di sicurezza

Important safety instructions


This product must only be employed for its originally intended use. The automation installation using these gearmotors requires
adequate safety systems on the gate leaves to detect any obstacles (e.g. sensitive edges), in compliance with UL325 standards and
CSA C22.2 No. 247 for both the US and Canada. Any other use is wrong and potentially dangerous.
The manufacturer cannot be held liable for any damages resulting from wrongful, erroneous or negligent uses.
Avoid working close to the hinges or other moving mechanical parts. Stay out of the opening/closing arc when operator is in motion.

Do not exercise force against the motion of the operator as this could result in potentially dangerous situations.
Pag. 29 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

Do not allow children to play or loiter within the opening/closing arc of the operator. Keep remote controls and any other command
device out the reach of children, to prevent operator from being activated by accident.

In the event of anomalous behaviour, stop using the operator immediately.

Danger of crushing hands Danger! High voltage

Danger of crushing feet No transit during operation


13 Maintenance
13.1 Periodic maintenance
Periodic maintenance to be carried out by the end-user is as follows: wipe clean the glass surface of the photocells;
check that the safety devices work properly; remove any obstructions.
We suggest checking the state of lubrication and tightness of the anchoring screws on the operator.
-To check the efficiency of the safety devices, move an object in front of the photocells when gate is closing.
If the operator inverts the motion or stops, the photocells are working properly.
This is the only maintenance procedure to be carried out with the power source connected.

Pag. 30 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
-Before performing any maintenance procedures, cut off the main power, to prevent possible accidents due to gate movement.
-To clean the photocells use a water dampened cloth. Do not use solvents or other chemical products which may ruin the de-
vices.
-In the event of any strange vibrations or squeaking, lubricate the joints with grease, as shown in the diagram.
-Make sure there are no plants within the photocells beam, and that the gate motion is free of any obstacles.

13.2 Troubleshooting

MALFUNCTIONS POSSIBLE CAUSES CHECK AND REMEDIES


The gate will not • There is no power • Check that the power is up
open nor close • The gearmotor is released • Call assistance
• The transmitters batteries are run down • Replace batteries
• The transmitter is broken • Call assistance
• The stop button is either stuck or broken • Call assistance
• The opening/closing button or the key selector are stuck • Call assistance
• Photocells in partial stop mode • Call assistance
The gate opens • The photocells are engaged • Check that photocells are clean and in
but will not close good working order
• Sensitive edge triggered • Call assistance
The gate closes • Sensitive edge triggered • Call assistance
but will not open
The flasher does • The bulb is burnt • Call assistance
not work
Periodic maintenance log for end-user (every 6 months)

Date Notes Signature


Pag. 31 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

13.3 Extraordinary maintenance


The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised
firms.
Note: Any extraordinary maintenance must be performed by specialised technicians.

Extraordinary maintenance log

Installer’s stamp Operator name


Date of job
Technician’s signature
Requester’s signature
Job performed________________________________________________________________________________________
______________________________________________________________________________________________

Installer’s stamp Operator name


Date of job
Technician’s signature
Requester’s signature
Job performed________________________________________________________________________________________
_____________________________________________________________________________________________

Installer’s stamp Operator name


Date of job
Technician’s signature
Requester’s signature
Job performed________________________________________________________________________________________
_____________________________________________________________________________________________
Installer’s stamp Operator name
Date of job
Technician’s signature
Requester’s signature
Job performed________________________________________________________________________________________
_____________________________________________________________________________________________

Installer’s stamp Operator name

Pag. 32 - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users
Date of job
Technician’s signature
Requester’s signature
Job performed________________________________________________________________________________________
_____________________________________________________________________________________________

14 Phasing out and disposal


CAME CANCELLI AUTOMATICI S.p.A. employs a UNI EN ISO 14001 certified and compliant environmental protection system
at its plants, to ensure that environmental safeguarding.
We ask you to keep protecting the environment, as CAME deems it to be one of the fundamental points of its market
operations strategies, by simply following these brief guidelines when disposing:

DISPOSING THE PACKING MATERIALS


The packing components (cardboard, plastic, etc.) are solid urban waste and may be disposed of without any particular difficulty,
by simply separating them so that they can be recycled.
Before actions it is always advisable to check the pertinent legislation where installation will take place.
DO NOT DISPOSE OF IN NATURE!
DISPOSING OF THE PRODUCT
Our products are made using different types of materials. The majority of them (aluminium, plastic, iron, electric cables) can be
considered to be solid urban waste. They may be recycled at authorised firms.
Other components (electrical circuit board, remote control batteries etc.) may contain hazardous waste.
They must, thus, be removed and turned in to licensed firms for their disposal.
Before acting always check the local laws on the matter.
DO NOT DISPOSE OF IN NATURE!

Intertek Testing Services NA Inc.


165 Main Street, Cortland, NY 13045
Telephone 800-345-3851 or 607-753-6711 Fax 607-756-6699

Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems, UL 325 - 5th edition,
Issued 06/07/2002. Revised 08/29/2007.
Standard(s):
Standard for Operators and Systems of Doors, Gates, Draperies and Louvres, CSA C22.2 No. 247.
Issued 12/01/1992 (R2004), General Instruction No. 1
Product: Vehicular Horizontal Slide Gate Operators
Models: BX-243U, BX-246U

CAME Cancelli Automatici S.p.A.


via Martiri della Libertà, 15
31030 Dosson di Casier - Treviso - ITALY
tel (+39) 0422 4940 - fax (+39) 0422 4941
internet: www.came.it - e-mail: [email protected]
THIS PAGE LEFT INTENTIONALLY BLANK
THIS PAGE LEFT INTENTIONALLY BLANK
THIS PAGE LEFT INTENTIONALLY BLANK
English - Manual code: 119BV34 ver. 2.0 11/2010 © CAME cancelli automatici s.p.a.