C/CW/CC Series Pneumatic Valves Catalog
C/CW/CC Series Pneumatic Valves Catalog
Catalog 0640-E/USA
April 2004
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze
all aspects of your application including consequences of any failure, and review the information concerning the product or
system in the current product catalog. Due to the variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products
and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its
authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this
document entitled “Offer of Sale”.
Features
• 3-Way, 2-Position.
• Single Solenoid.
• Inline mounting.
• Cv 2.0.
C J1 25 01 --
Application Application
These 3-Way, 2-Position, direct solenoid operated, (maintained These 3-Way, 2-Position, remote pressure operated spool
contact) spool valves are used to operate single acting valves are used to operate single acting cylinders. They
cylinders. They can be used as normally closed or normally can be used as normally closed or normally open, and as
open, and as a 2-Way. a 2-Way.
Mounting Mounting
Intended for inline use. Use “C” Series for mounting to Intended for inline use. Use “C” Series for mounting to
horizontal surfaces. Use “CW” Series for mounting to vertical horizontal surfaces. Use “CW” Series for mounting to vertical
bulkheads. bulkheads.
Operation Operation
Solenoid De-energized – Port “A” is blocked, port “0” is De-energized or Spring Returned Position of the Spool –
connected to port “B”. When solenoid is energized, port “A” is Pressure at inlet port “A” is blocked and port “0” is connected to
connected to port “0” and port “B” is blocked. Because of the port “B”. When pilot is energized, port “A” is connected to port
area-balanced construction of the spool, either port “A” or port “0” and port “B” is blocked. Because of the area-balanced
“B” may be used as the inlet supply port. Pressure to port “A” construction of the spool, either port “A” or port “B” may be used
valve is normally closed valve. Pressure to port “B” valve is as the inlet supply port. Pressure to port “A” valve is normally
normally open valve. closed valve. Pressure to port “B” is normally open valve.
0 0 0 0
A B AB AB AB
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted CWJ12501 1/4" NPT Wall Mounted CW1025
3/8" NPT Wall Mounted CWJ13701 3/8" NPT Wall Mounted CW1037
Application Application
These 3-Way, 2-Position, double remote pressure operated These 3-Way, 2-Position, cam operated spool valves are used to
spool valves are used to operate single acting cylinders. They operate single acting cylinders. They can be used
can be used as normally closed or normally open, as normally closed or normally open, and as a 2-Way.
and as a 2-Way.
Mounting
Mounting Intended for inline use. Use “C” Series for mounting to horizontal
Intended for inline use. Use “C” Series for mounting to surfaces. Use “CW” Series for mounting to vertical bulkheads.
horizontal surfaces. Use “CW” Series for mounting to vertical
bulkheads. Operation
Operation De-energized or Spring Returned Position of the Spool –
Pressure at inlet port “A” is blocked and port “0” is connected to
When pressure is applied to port “2” last, pressure at inlet port port “B”. When ball is activated, port “A” is connected to port “0”
“A” is blocked and port “0” is connected to port “B”. When and port “B” is blocked. Because of the area-balanced
pressure is applied to port “1” last, port “A” is connected to port construction of the spool, either port “A” or port “B” may be used
“0” and port “B” is blocked. Because of the area-balanced as the inlet supply port. Pressure to port “A” valve is normally
construction of the spool, either port “A” or port “B” may be used closed valve. Pressure to port “B” is normally open valve.
as the inlet supply port. Pressure to port “A” valve is normally
closed valve. Pressure to port “B” valve is normally open valve.
#2 #1 #2 #1
Operator Operator Operator Operator
End End End End
0 0 0 0
A B AB AB A B
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted CW1225 1/4" NPT Wall Mounted, Ball Cam CW225
3/8" NPT Wall Mounted CW1237 3/8" NPT Wall Mounted, Ball Cam CW237
C94 & CW94 Heavy Duty C92 & CW92 Overriding Cam
Application Application
These 3-Way, 2-Position, cam operated spool valves are used These 3-Way, 2-Position, cam operated spool valves are used
to operate single acting cylinders. They can be used to operate single acting cylinders. They can be used
as normally closed or normally open, and as a 2-Way. as normally closed or normally open, and as a 2-Way.
Mounting Mounting
Intended for inline use. Use “C” Series for mounting to Intended for inline use. Use “C” Series for mounting to
horizontal surfaces. Use “CW” Series for mounting to vertical horizontal surfaces. Use “CW” Series for mounting to vertical
bulkheads. bulkheads.
Operation Operation
De-energized or Spring Returned Position of the Spool – De-energized or Spring Returned Position of the Spool –
Pressure at inlet port “A” is blocked and port “0” is connected to Pressure at inlet port “A” is blocked and port “0” is connected to
port “B”. When cam is activated, port “A” is connected to port “0” port “B”. When cam is activated, port “A” is connected to port “0”
and port “B” is blocked. Because of the area-balanced and port “B” is blocked. Because of the area-balanced
construction of the spool, either port “A” or port “B” may be used construction of the spool, either port “A” or port “B” may be used
as the inlet supply port. Pressure to port “A” valve is normally as the inlet supply port. Pressure to port “A” valve is normally
closed valve. Pressure to port “B” valve is normally open valve. closed valve. Pressure to port “B” is normally open valve.
C94 and CW94 operate from either direction. C92 and CW92 are overriding cams which operate in one
direction only.
0 0 0 0
AB A B A B AB
Normally Closed Normally Open Normally Closed Normally Open
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted, Heavy Duty, CW9425 1/4" NPT Wall Mounted, Heavy Duty, CW9225
Roller Lever Overriding Roller Lever
3/8" NPT Wall Mounted, Heavy Duty, CW9437 3/8" NPT Wall Mounted, Heavy Duty, CW9237
Roller Lever Overriding Roller Lever
ED
C13 & CW13 Cam C9 & CW9 Overriding Cam
Application Application
NU
These 3-Way, 2-Position, cam operated spool valves are used These 3-Way, 2-Position, cam operated spool valves are used
to operate single acting cylinders. They can be used to operate single acting cylinders. They can be used
as normally closed or normally open, and as a 2-Way. as normally closed or normally open, and as a 2-Way.
Mounting Mounting
Intended for inline use. Use “C” Series for mounting to Intended for inline use. Use “C” Series for mounting to
TI
horizontal surfaces. Use “CW” Series for mounting to vertical horizontal surfaces. Use “CW” Series for mounting to vertical
bulkheads. bulkheads.
Operation Operation ON
De-energized or Spring Returned Position of the Spool – De-energized or Spring Returned Position of the Spool –
Pressure at inlet port “A” is blocked and port “0” is connected to Pressure at inlet port “A” is blocked and port “0” is connected to
port “B” exhaust as normally closed valve. Because of the area- port “B” exhaust as a normally closed valve. Because of the
balanced construction of the spool, either port “A” or port “B” area-balanced construction of the spool, either port “A” or port
may be used as the inlet supply port. Pressure to port “A” valve “B” may be used as the inlet supply port. Pressure to port “A”
SC
is normally closed valve. Pressure to port “B” valve is normally valve is normally closed valve. Pressure to port “B” valve is
open valve. normally open valve.
DI
0 0 0 0
AB A B A B AB
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted, Roller Cam CW1325 1/4" NPT Wall Mounted, Overriding Cam CW925
3/8" NPT Wall Mounted, Roller Cam CW1337 3/8" NPT Wall Mounted, Overriding Cam CW937
C5 CW5 C4 CW4
Application Application
These 3-Way, 2-Position, hand operated spool valves are used These 3-Way, 2-Position, hand operated spool valves are used
to operate single acting cylinders. They can be used to operate single acting cylinders. They can be used
as normally closed or normally open, and as a 2-Way. as normally closed or normally open, and as a 2-Way.
Mounting Mounting
Intended for inline use. Use “C” Series for mounting to Intended for inline use. Use “C” Series for mounting to
horizontal surfaces. Use “CW” Series for mounting to vertical horizontal surfaces. Use “CW” Series for mounting to vertical
bulkheads. bulkheads.
Operation Operation
With Hand Lever in Centered Position – Pressure at inlet port De-energized or Spring Returned Position of the Spool –
“A” is blocked and port “0” is connected to port “B” With the Pressure at inlet port “A” is blocked and port “0” is connected to
hand lever shifted to one place and locked, port “A” is port “B”. When hand lever is activated, port “A” is connected to
connected to port “0” and port “B” is blocked. Because of the port “0” and port “B” is blocked. Because of the area-balanced
area-balanced construction of the spool, either port “A” or port construction of the spool, either port “A” or port “B” may be used
“B” may be used as the inlet supply port. Pressure to port “A” as the inlet supply port. Pressure to port “A” valve is normally
valve is normally closed valve. Pressure to port “B” valve is closed valve. Pressure to port “B” valve is normally open valve.
normally open valve.
0 0 0 0
A B AB A B AB
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Wall Mounted, Hand Toggle, CW525 1/4" NPT Wall Mounted, Hand Toggle, CW425
Locking Non-Locking
3/8" NPT Wall Mounted, Hand Toggle, CW537 3/8" NPT Wall Mounted, Hand Toggle, CW437
Locking Non-Locking
C3 CW3 C6
Application Application
These 3-Way, 2-Position, hand operated spool valves are used These 3-Way, 2-Position, foot operated spool valves are used to
to operate single acting cylinders. They can be used operate single acting cylinders. They can be used
as normally closed or normally open, and as a 2-Way. as normally closed or normally open, and as a 2-Way.
Mounting Mounting
Intended for inline use. Use “C” Series for mounting to These valves are designed for side ported, subbase mounting.
horizontal surfaces. Use “CW” Series for mounting to vertical ! CAUTION:
bulkheads. This valve shall not be used to actuate a punch press. Do
not use this valve on punch presses or press brakes. See
Operation OSHA 1910.217.
De-energized or Spring Returned Position of the Spool –
Pressure at inlet port “A” is blocked and port “0” is connected to Operation
port “B”. When button is depressed, port “A” is connected to port De-energized or Spring Returned Position of the Spool –
“0” and port “B” is blocked. Because of the area-balanced Pressure at inlet port “A” is blocked and port “0” is connected to
construction of the spool either port “A” or port “B” may be used port “B”. With foot pedal depressed, port “A” is connected to port
as the inlet supply port. Pressure to port “A” valve is normally “0” and port “B” is blocked. Because of the area-balanced
closed valve. Pressure to port “B” valve is normally open valve. construction of the spool, either port “A” or port “B” may be used
as the inlet supply port. Pressure to port “A” valve is normally
closed valve. Pressure to port “B” valve is normally open valve.
0 0
0 0
A B AB
Operating Pressure
2-Position Solenoid and Mechanical Valve:
0 to 150 PSIG (0 to 1035 kPa)
Also suitable for vacuum service.
Temperature
0°F to 140°F (–18°C to 71°C)
! CAUTION:
This valve shall not be used to actuate a punch press. Lubrication
Do not use this valve on punch presses or press brakes. Filtered and lubricated air recommended for maximum life and
See OSHA 1910.217. minimum maintenance.
Mounting
2-Position Single Solenoid
Mounting bolts for C6 Foot Valve are furnished in this Kit.
Average Fill Time: (Seconds)*
Valve 12 Cu. In. Test Chamber 100 Cu. In. Test Chamber
Port Size Fill Exhaust Fill Exhaust
1/4" .027 .044 .184 .269
Model Selection Information 3/8" .025 .040 .147 .235
Description Part Number
* With 100 PSI supply, time required to fill from 0-90 PSI and exhaust
Pedal Guard Kit PS2043 from 100 PSI to 10 PSI is measured from instant of energizing, or
de-energizing 120V/60Hz solenoid. Times shown are average.
C B
D
(2 mtg. holes) K
+.02
.19 Travel –.00 J
AA
L
A
A A M
X 0
0 0
F N
B B
E E B
G
H P
CJ1
Base Mounted Valve Body
H
K
+.02
.19 Travel –.00 J
AA D L
(2 mtg.
holes) A
A M
A Q 0 S
X 0 F N
0
B
B B
R
Q
T
CWJ1 Wall Mounted Valve Body
Dimensions:
A B C D E F G H J K
inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D
mm 30 27 52 7Ø 33 28 18 65 5.1Ø 25.4Ø
L M N P Q R S T U V
inches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62 3.12
mm 18 4 59 6 19 13 14 54 41 79
W X Y Z AA
inches 1.56 .67 3.60 1.94 5.72
mm 40 17 91 49 145
V V
C B
A A
W W
0 0
B
D
B
(2 mtg.
holes)
1/8 NPT
C10 CW10
H P U B
Base Mounted Valve Body
#6-32 Tap .25 deep H
A 4 holes
1/8 NPT
U B
D
H K (2 mtg.
+.02
.19 Travel –.00 J holes) A
A
W
D L Q S Y
0
(2 mtg. F N
holes) A B
A M
B
Q 0 S R
F N
B
B
R T B
T 1/8 NPT
Wall Mounted Valve Body CW12
Dimensions:
A B C D E F G H J K L
inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D .69
mm 30 27 52 7Ø 33 28 18 65 5.1Ø 25.4Ø 18
M N P Q R S T U V W Y
inches .16 2.34 .25 .75 .50 .56 2.12 1.62 1.38 3.74 4.25
mm 4 59 6 19 13 14 54 41 35 95 108
D
(2 mtg. holes) K
+.02
J
C92 - CW92 .19 Travel –.00
Heavy Duty Overriding L
Roller Lever A
A M
0
1.53 F N
.50 B
E B
.20 G
Actuator May
Be Rotated 180
H P
Base Mounted Valve Body
2.00
1.34
#6-32 Tap .25 deep
A 4 holes
.25
.77
U B
Min. Travel
to Actuate
1.50 Dia. H
35 35 .25 Min. to Actuate K
+.02
.19 Travel –.00 J
80 Max.
Travel D L
(2 mtg.
holes) A
A M
1.25
3.34 Q 0 S
F N
B
5.73 Max. Overall B
Valve Length R
T
Wall Mounted Valve Body
C94 - CW94
Heavy Duty
Roller Lever
Dimensions:
A B C D E F G H J K
inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D
mm 30 27 52 7Ø 33 28 18 65 5.1Ø 25.4Ø
L M N P Q R S T U
inches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62
mm 18 4 59 6 19 13 14 54 41
30° Max.
Cam Angle
.19 Travel A
.62 Dia. #6-32 Tap .25 deep
4 holes
1.41
C B
3.77 Max. Overall
Note: Operates From Valve Length
Any Direction D
(2 mtg. holes) K
C2 - CW2 +.02
.19 Travel –.00 J
Ball Cam
L
A
A M
0
F N
Operate B
E B
G
Non-Operate
.50 Dia. 30° Max.
Cam Angle H P
.19 Travel
Base Mounted Valve Body
2.05
C9 - CW9 U B
Overriding Cam
H
K
+.02
.19 Travel –.00 J
D L
Operate (2 mtg.
30° Max. holes) A
A M
1.00 Dia. Cam Angle Q 0 S
.19 Travel F N
B
B
1.83 R
T
4.19 Max. Overall Wall Mounted Valve Body
Valve Length
C13 - CW13
Roller Cam
Dimensions:
A B C D E F G H J K
inches 1.19 1.06 2.06 .28D 1.28 1.12 .72 2.56 .20D 1.00D
mm 30 27 52 7Ø 33 28 18 65 5.1Ø 25.4Ø
L M N P Q R S T U
inches .69 .16 2.34 .25 .75 .50 .56 2.12 1.62
mm 18 4 59 6 19 13 14 54 41
1.31 A
Dia. #6-32 Tap .25 deep
.19 Travel 4 holes
1.03 C B
L
A
A M
0
F N
B
E B
G
H P
36 45 Base Mounted Valve Body
4.00 4.00
6.36 6.36
Max. Overall Max. Overall U B
Valve Length Valve Length
H
C4 - CW4 C5 - CW5 K
+.02
Hand Valve Hand Valve .19 Travel –.00 J
Non-Locking Locking D L
Handle free to rotate 360 around vertical axis. (2 mtg.
holes) A
A M
Q 0 S
F N
B
B
R
T
Dimensions: Dimensions:
Wall Mounted Valve Body
inches mm inches mm
A 1.19 30 L .69 18
B 1.06 27 M .16 4
C 2.06 52 N 2.34 59
D .28D 7Ø P .25 6
E 1.28 33 Q .75 19
F 1.12 28 R .50 13
G .72 18 S .56 14
H 2.56 65 T 2.12 54
J .20D 5.1Ø U 1.62 41
K 1.00D 25.4Ø
Dimensions:
inches mm
A 4.12 105
B 3.16 80
C .88 22
D 1.75 44
M K B
F 4.22 107 L
G .16 4
H .59 15
J .94 24 N
K 2.62 67 B
B
L 1.31 33 0
Q
M 2.06 52 A A
H Travel A
N 2.56 65 P
R
J
P 2.19 56
Q 1.12 28 G C
S
D
R 1.62 41 F
S .19 5
C6 Non-Locking
Dimensions:
inches mm A
A 4.50 114
A1 .75 19 A1
B 10.50 267 B1 B C
B1 1.25 32
C .48 11
D 6.00 152
E 7.13 181 E
E1 .50 13 E1
F 13.00 330
F1 8.38 213 D F1
F
Features
• 4-Way, 2-Position.
• Cv 1.5
CCJ1 Series
Single Solenoid and Optional
Sandwich Flow Controls
CC J1 S 25 B 01 --
Application Application
These 4-Way, 2-Position direct solenoid operated, (maintained These 4-Way, 2-Position direct solenoid operated (momentary
contact) spool valves are used to operate double acting contact) spool valves are used to operate double acting
cylinders. They may also be used as 2-Way or 3-Way valves cylinders. They may also be used as 2-Way or 3-Way valves by
by plugging appropriate ports. plugging appropriate ports.
Mounting Mounting
These valves are designed for side ported, subbase mounting. These valves are designed for side ported, subbase mounting.
Operation Operation
Solenoid De-energized – Port “A” is connected to port “02”, Solenoid 1 Last Energized – Pressure at inlet port “A”
port “B” to port “01”. When solenoid is energized, port “A” connected to outlet port “02”. Outlet port “01” connected to
connects to port “01”, port “B” to port “02”. Because of the exhaust port “B”.
area-balanced construction of the spool, either port “A” or Solenoid 2 Last Energized – Pressure at inlet port “A”
port “B” may be used as the inlet supply port. connected to outlet port “01”. Outlet port “02” connected to
exhaust port “B”. Because of the area-balanced construction of
the spool, either port “A” or port “B” may be used as the inlet
supply port.
B A B A
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Valve with Side Ported Subbase CCJ125B01 1/4" NPT Valve with Side Ported Subbase CCJ1125B01
3/8" NPT Valve with Side Ported Subbase CCJ137B01 3/8" NPT Valve with Side Ported Subbase CCJ1137B01
Following model numbers include the Integral Flow Control Section , Following model numbers include the Integral Flow Control Section,
120V/60Hz. 120V/60Hz.
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Valve with Side Ported Subbase CCJ1S25B01 1/4" NPT Valve with Side Ported Subbase CCJ11S25B01
3/8" NPT Valve with Side Ported Subbase CCJ1S37B01 3/8" NPT Valve with Side Ported Subbase CCJ11S37B01
Application Application
These 4-Way, 2-Position remote pressure actuated, spool These 4-Way, 2-Position remote pressure actuated, spool
valves are used to operate double acting cylinders. They may valves are used to operate double acting cylinders. They may
also be used as 2-Way or 3-Way valves by plugging appropriate also be used as 2-Way or 3-Way valves by plugging appropriate
ports. Valves are actuated by maintained pressure signal. ports. Valves are actuated by a “momentary” pressure signal
alternately to each of the air pilot ports.
Mounting
These valves are designed for side ported, subbase mounting. Mounting
These valves are designed for side ported, subbase mounting.
Operation
De-energized or Spring Returned Position of the Spool – Operation
Pressure at inlet port “A” connected to outlet port “02”. Remote Pressure at Piston Actuator #1 – Pressure at inlet
Outlet port “01” connected to exhaust port “B”. When pilot is port “A” connected to outlet port “02”. Outlet port “01”
pressurized, port “A” connects to “01” and port “B” to port “02”. connected to exhaust port “B”.
Because of the area-balanced construction of the spool, either Remote Pressure at Piston Actuator #2 – Pressure at inlet
port “A” or port “B” may be used as the inlet supply port. port “A” connected to outlet port “01”. Outlet port “02”
connected to exhaust port “B”. Because of the area-balanced
construction of the spool, either port “A” or port “B” may
be used as the inlet supply port.
02 01 02 01
#2 #1
Operator Operator
End End
B A B A
Following model numbers include the Integral Flow Control Section . Following model numbers include the Integral Flow Control Section.
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Spring Return CC10S25B 1/4" NPT Side Ported, Remote Pressure Return CC12S25B
3/8" NPT Side Ported, Spring Return CC10S37B 3/8" NPT Side Ported, Remote Pressure Return CC12S37B
Application Application
These 4-Way, 2-Position, cam operated spool valves are used These 4-Way, 2-Position, cam operated spool valves are used
to operate double acting cylinders. They may also be used as to operate double acting cylinders. They may also be used as
2-Way or 3-Way valves by plugging appropriate ports. The 2-Way or 3-Way valves by plugging appropriate ports. The
heavy duty overriding roller operates in only one direction. heavy duty roller operates in either direction.
Mounting Mounting
These valves are designed for side ported, subbase mounting. These valves are designed for side ported, subbase mounting.
Operation Operation
De-energized or Spring returned Position of the Spool – De-energized or Spring Returned Position of the Spool –
Pressure at inlet port “A” connected to outlet port “02”. Pressure at inlet port “A” connected to outlet port “02”.
Outlet port “01” connected to exhaust port “B”. When cam is Outlet port “01” connected to exhaust port “B”. When cam is
activated, pressure at inlet port “A” connects to outlet port “01”. activated, pressure at inlet port “A” connects to outlet port “01”.
Outlet port “02” connected to exhaust port “B”. Because of Outlet port “02” connected to exhaust port “B”. Because of
the area-balanced construction of the spool, either port “A” the area-balanced construction of the spool, either port “A”
or port “B” may be used as the inlet supply port. or port “B” may be used as the inlet supply port.
CC92 is an overriding cam which operates in one CC94 operates from either direction.
direction only.
02 01 02 01
B A B A
Following model numbers include the Integral Flow Control Section. Following model numbers include the Integral Flow Control Section.
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Heavy Duty, CC92S25B 1/4" NPT Side Ported, Heavy Duty, CC94S25B
Overriding Roller Lever Roller Lever
3/8" NPT Side Ported, Heavy Duty, CC92S37B 3/8" NPT Side Ported, Heavy Duty, CC94S37B
Overriding Roller Lever Roller Lever
Application Application
These 4-Way, 2-Position, cam operated spool valves are used These 4-Way, 2-Position, cam operated spool valves are used
to operate double acting cylinders. They may also be used as to operate double acting cylinders. They may also be used as
NU
2-Way or 3-Way valves by plugging appropriate ports. The 2-Way or 3-Way valves by plugging appropriate ports. The roller
overriding roller operates in only one direction. operates in either direction.
Mounting Mounting
These valves are designed for side ported, subbase mounting. These valves are designed for side ported, subbase mounting.
TI
Operation Operation
De-energized or Spring Returned Position of the Spool – De-energized or Spring Returned Position of the Spool –
Pressure at inlet port “A” connected to outlet port “02”. Pressure at inlet port “A” connected to outlet port “02”.
ON
Outlet port “01” connected to exhaust port “B”. When cam is Outlet port “01” connected to exhaust port “B”. When cam is
activated, pressure at inlet port “A” connects to outlet port “01”. activated, pressure at inlet port “A” connects to outlet port “01”.
Outlet port “02” connected to exhaust port “B”. Because of the Outlet port “02” connected to exhaust port “B”. Because of the
area-balanced construction of the spool, either port “A” or area-balanced construction of the spool, either port “A” or
port “B” may be used as the inlet supply port. port “B” may be used as the inlet supply port.
SC
CC9 is an overriding cam which operates in one CC13 operates from either direction.
direction only.
02 01 02 01
DI
B A B A
Following model numbers include the Integral Flow Control Section . Following model numbers include the Integral Flow Control Section.
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Overriding Cam CC9S25B 1/4" NPT Side Ported, Roller Cam CC13S25B
3/8" NPT Side Ported, Overriding Cam CC9S37B 3/8" NPT Side Ported, Roller Cam CC13S37B
Application Application
These 4-Way, 2-Position, cam operated spool valves are used These 4-Way, 2-Position, hand operated spool valves are used
to operate double acting cylinders. They may also be used as to operate double acting cylinders. They may also be used as
2-Way or 3-Way valves by plugging appropriate ports. 2-Way or 3-Way valves by plugging appropriate ports.
Mounting Mounting
These valves are designed for side ported, subbase mounting. These valves are designed for side ported, subbase mounting.
Operation Operation
De-energized or Spring Returned Position of the Spool – De-energized or Spring Returned Position of the Spool –
Pressure at inlet port “A” connected to outlet port “02”. Pressure at inlet port “A” connected to outlet port “02”.
Outlet port “01” connected to exhaust port “B”. When cam is Outlet port “01” connected to exhaust port “B”. When hand
activated, pressure at inlet port “A” connects to outlet port “01”. button is depressed, pressure at inlet port “A” connects to
Outlet port “02” connects to exhaust port “B”. Because of the outlet port “01”. Outlet port “02” connected to exhaust port “B”.
area-balanced construction of the spool, either port “A” or Because of the area-balanced construction of the spool, either
port “B” may be used as the inlet supply port. port “A” or port “B” may be used as the inlet supply port.
02 01 02 01
B A B A
Following model numbers include the Integral Flow Control Section. Following model numbers include the Integral Flow Control Section.
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Ball Cam CC2S25B 1/4" NPT Side Ported, Palm Button CC3S25B
3/8" NPT Side Ported, Ball Cam CC2S37B 3/8" NPT Side Ported, Palm Button CC3S37B
Application Application
These 4-Way, 2-Position, hand operated spool valves are used These 4-Way, 2-Position, hand operated spool valves are used
to operate double acting cylinders. They may also be used as to operate double acting cylinders. They may also be used as
2-Way or 3-Way valves by plugging appropriate ports. Valves 2-Way or 3-Way valves by plugging appropriate ports. Valves
are actuated by maintained hand operation. are manually operated and will remain in the last set position
when released.
Mounting
These valves are designed for side ported, subbase mounting. Mounting
These valves are designed for side ported, subbase mounting.
Operation
De-energized or Spring Returned Position of the Spool – Operation
Pressure at inlet port “A” connected to outlet port “02”. Outlet With Lever in Centered Position – Pressure at inlet port “A”
port “01” connected to exhaust port “B”. With hand lever moved connected to outlet port “02”. Outlet port “01” connected to
in either full up or full down position, pressure at inlet port “A” exhaust port “B”. With the hand lever moved in either full up
connects to outlet port “01”. Outlet port “02” connected to or full down position, pressure at inlet port “A” connects to
exhaust port “B”. Because of the area-balanced construction outlet port “01”. Outlet port “02” connected to exhaust port “B”.
of the spool, either port “A” or port “B” may be used as the Because of the area-balanced construction of the spool, either
inlet supply port. port “A” or port “B” may be used as the inlet supply port.
02 01 02 01
B A B A
Following model numbers include the Integral Flow Control Section . Following model numbers include the Integral Flow Control Section.
Port Size Description Model Number Port Size Description Model Number
1/4" NPT Side Ported, Hand Toggle, CC4S25B 1/4" NPT Side Ported, Hand Toggle, CC5S25B
Non-Locking Locking
3/8" NPT Side Ported, Hand Toggle, CC4S37B 3/8" NPT Side Ported, Hand Toggle, CC5S37B
Non-Locking Locking
Application Application
These 4-Way, 2-Position, foot operated spool valves are used This pedal guard is designed to protect the foot operated valve
to operate double acting cylinders. They may also be used as from accidental operation that may be caused by falling objects
2-Way or 3-Way valves by plugging appropriate ports. or inadvertent contact.
Mounting ! CAUTION:
These valves are designed for side ported, subbase mounting. Foot valves utilizing this guard shall not be used to actuate
a punch press. Do not use this valve on punch presses or
! CAUTION: press brakes. See OSHA 1910.217.
This valve shall not be used to actuate a punch press.
Do not use this valve on punch presses or press brakes. Mounting
See OSHA 1910.217. Mounting bolts for CC6 Foot Valve, opposite, are furnished
in this kit.
Operation
De-energized or Spring Returned Position of the Spool –
Pressure at inlet port “A” connected to outlet port “02”.
Outlet port “01” connected to exhaust port “B”. When pedal is
depressed, pressure at inlet port “A” connects to outlet port “01”.
Outlet port “02” connects to exhaust port “B”. Because of the
area-balanced construction of the spool, either port “A” or
port “B” may be used as the inlet supply port.
02 01
B A
Operating Pressure
2-Position Solenoid and Mechanical Valve:
0 to 150 PSIG (0 to 1035 kPa) 1/2 NPSM
02 01
Also suitable for vacuum service.
2-Position Air Pilot Valve:
0 to 150 PSIG (0 to 1035 kPa) C M L
Also suitable for vacuum service.
P
Pilot pressures 30 to 150 PSI (207 to 1035 kPa). N
A B
Temperature R Q
S (2 mtg. holes)
0°F to 160°F (–18°C to +71°C)
A
A1
Electrical Data: 120 Volt AC 60Hz
Voltage Range +10/-15% of Nominal
Class B D
W/O
13.8 Watts 2.1 Amp Inrush .5 Amp Holding F.C.
D
W/O
Note: Coils are not intended for continuous duty F.C.
B A
F
G
Lubrication J
Filtered and lubricated air recommended for maximum life and K
minimum maintenance. H
E
Valve 12 Cu. In. Test Chamber 100 Cu. In. Test Chamber
Size N1
Fill Exhaust Fill Exhaust
1/4" .034 .620 .206 .407 CCJ1
3/8" .030 .630 .177 .375
* With 100 PSI supply, time required to fill from 0-90 PSI and exhaust
from 100 PSI to 10 PSI is measured from instant of energizing, or
de-energizing 120V/60Hz solenoid. Times shown are average. Dimensions: Dimensions:
inches mm inches mm
A 6.25 159 J .59 15
Flow Rating (Cv) A1 4.75 121 K 1.19 30
Valve Port Sizes
Flow Path B 3.69 94 L 2.56 65
1/4" 3/8"
A 01 1.3 1.8 B1 4.28 109 M 2.06 52
01 A 1.4 1.7 C 3.12 79 N 1.56 40
B 01 1.1 1.4
D 2.56 65 N1 1.97 50
01 B 1.3 1.3
A 02 1.4 1.8 D1 3.15 90 P 1.03 26
02 A 1.3 1.7 E 2.70 69 Q .25 06
B 02 1.3 1.3 F .97 25 R .81 21
02 B 1.2 1.4
G .50 13 S .28 7
Average 1.3 1.5
H 1.38 35
M L
C M L 1/8 NPT P
P
N B A
Q
B A
D (2 mtg. holes)
Q A1
S (2 mtg. holes)
A
A
D
B1
B W/
W/O F.C.
F.C.
B B A
F
W/O G
F.C.
J
K C
H N
B A
F E
G
CC10
J
K 02 01
H
E
M L
1/8 NPT P
2 Places
B A
Q
D (2 mtg. holes)
B1
W/
A2
F.C. A
B1
B W/
W/O F.C.
F.C.
N1
B A
F
G
J C
K N
CCJ11 H
E
CC12
Dimensions:
A B B1 C D E F G H J
inches 3.00 2.56 3.15 1.47 min. .28 2.70 .987 .50 1.35 .59
mm 76 65 80 37 7 69 25 13 34 15
K L M N P Q
inches 1.19 2.56 2.06 1.97 max. 1.03 .25
mm 30 65 52 50 26 6
CC4 Non-Locking
CC5 Locking
1.31 Dia.
B
B1 F .97 25
W/
W/O
F.C.
F.C. G .50 13
B A
G
F H 1.35 34
J
C J .59 15
K
H N K 1.19 30
E
L 2.56 65
Valve Body
M 2.06 52
N 1.97 50
max.
P 1.03 26
Q .25 6
Dimensions:
inches mm
A 5.19 132
A1 5.77 147
B 4.12 105
C .94 24 J L K
D .59 15 M
E .16 4
F .88 22
N
G 1.75 44 P
H 4.22 107
IN 01
J 2.06 52
K 3.16 80
B
L 2.62 67 EXH 02 Q
D Travel
M 1.31 33 R
C
N 1.09 28
P .55 14 E F
G
Q 3.16 80 H
A A1
R 2.09 53 W/O W/F.C.
F.C.
CC6 Non-Locking
! CAUTION:
This valve shall not be used to actuate a punch press.
Do not use this valve on punch presses or press brakes.
See OSHA 1910.217.
A
Dimensions:
inches mm
A 4.50 114 A1
A1 .75 19 B1 B C
B 10.50 267
B1 1.25 32
C .48 11
E
D 6.00 152
E 7.13 181 E1
E1 .50 13
F 13.00 330 D F1
F
F1 8.38 213
Description:
• The Integral Flow Control Section can be used with
any CC Series Air Control Valve.
A 2.70 69
B 2.12 54 C
D
C .28 7
D .78 20
E .56 14 E
Obsolete Functional
Part Number Replacement Description / Notes Valve Service Kits
C325M1 C325 Standard size button PL502600
C337M1 C337 Standard size button PL502600
C525M4 C525 Straight handle, locking PL5379
C525M6 C525 Straight handle, locking PL5379
C937 C9237 Heavy Duty Overriding Cam Unidirectional 3/8" ports PL502600
CC125B01M8 Use service kit. PL503500
CC325BM1 CC325B Standard size button PL503300
CC337BM1 CC337B Standard size button PL503300
CCJ1125B02 PL503200
CCJ1137B01M11 Use service kit. PL5450
CCJ1137B01M28 Use service kit. PL5450
CCJ1137B02 F5215BGC87A Dbl Sol 240vac Valve 3/8" npt PL503200
CCJ1S25B02 F5E13BGC87001A Sgl Sol 240vac valve 1/4 npt w/ flow control PL503000
CCJ1S25B03 Use service kit. PL503000
CCJ1S37B01M28 Use service kit. PL5450
CCJ1S37B02 F5E15BGC87001A Sgl Sol 240vac valve 3/8 npt w/ flow control PL503000
Obsolete Functional
Part Number Replacement Description / Notes Valve Service Kits
CCJ1SVXB15 Use service kit. PL503000
CCJ1SVXB24 Use service kit. PL503000
CCJ1VXB24 Use service kit. PL503000
CCJY00004 Use service kit. PL5450