APOLLO
COMMISSIONING
COMMISSIONING ACCESSORIES / SOFTWARE
Accessories required:
Laptop/PC with serial/USB port.
USB to RS-232 (DB9) cable convertor.
RS-232 (DB-9) to RJ-45 serial cable.
CODM Debug accessory + cables.
Mini-USB to RS-232(DB-9) Gray cable
HDMI to Mini HDMI black cable.
SD & CF memory card reader : Transcend-TS-RDF8K-USB-3.0
Software required:
NVM Loader version: EciApolloNvmBurningUtil.3.0.0.1
Latest compatible LCT-STMS on your laptop.
Secure CRT
1
SD CARD
PREPARATION
2
NVM PREPARATION
NVM Loader version: EciApolloNvmBurningUtil.3.0.0.1
Don’t Format SD card, when asked.
Select proper drive & NE Type:
3
Select Proper ST version(.Tar file) & Click start Then click Yes
4
will start extracting then formatting partition
5
Time window
6
successful completion
7
COMMISSIONING
USING CLI
8
LAN Details:
Connect LAN for LCT/Local port of OPT9603 & put below details in Laptop LAN
9
Steps to be followed:
Open CLI(Secure CRT) & telnet 192.168.10.10(Default LCT port IP)
Login as admin
user: admin
password: admin1
following prompt appears: admin@localhost>
To shift to configure/edit mode, type: configure:
admin@localhost>configure
Entering configuration mode
Users currently editing the configuration:
[edit]
The following prompt appears: admin@localhost#
10
Setting UP Host name(NE Name)
admin@localhost# set system host-name OPT9603 //Put NE name here
For any mistake made after this command you can delete it by using rollback if
it is ok continue to commit it.
admin@localhost# rollback
load complete
OR
Type commit:
admin@localhost# commit
Commit succeeded.
You will able to see that host name of the Apollo chassis changed.
[edit]
admin@OPT9603#
Note: Once you commit, it cannot be rollback. For any change after commit, u need to delete/set entry.
11
Setting Up the Time and the Time Zone
Setup the time
admin@OPT9603# set system time-zone <Zone> ; //which is Asia/Calcutta
admin@OPT9603# run set date <MMDDhhmmYYYY>
For any mistake made after this command you can delete it by using rollback if it is ok
continue to commit it.
admin@OPT9603# rollback
load complete
OR
Type commit:
admin@OPT9603# commit
Commit succeeded.
reboot will be required to make time-zone changes effective.
admin@OPT9603# run request system reboot
12
Setting Up NE ID
admin@OPT9603# set network-element opt96xx ne-id <NE ID> //for example 111
admin@OPT9603# commit
Setting Up the IP Address, Subnet Mask, and Gateway of the NE
For DCC Only Node:
Set management mode and DCN address
admin@OPT9603# set system management-mode dcn <DCN address>
//for example: 10.10.10.2
admin@OPT9603# commit.
13
For Gateway Node:
Set system DCN address
admin@OPT9603# set system management-mode dcn <DCN address>
// for example: 10.10.10.2
admin@OPT9603# commit
Enable IMG port
admin@OPT9603# set chassis rcp port 0 enable
admin@OPT9603# commit
Setup the IP address and the subnet mask of the management port
admin@OPT9603# set interfaces fe-rcp unit 0 family inet address <IP/Mask>
//for example: 172.30.88.114/22
admin@OPT9603# commit
14
For Ethernet Only Node:
Enable IMG port
admin@OPT9603# set chassis rcp port 0 enable
admin@OPT9603# commit
Set management mode and Ethernet address
admin@OPT9603# set system management-mode Ethernet-only <ethernet address>
//for example: 10.10.10.2
admin@OPT9603# commit
15
General commands
admin@OPT9603# set system services telnet enable-network -For telnet enable
admin@OPT9603# set system services telnet root-login allow -For telnet root-login allow
admin@OPT9603# set system services ssh enable-network -For ssh enable
admin@OPT9603# set system services ssh root-login allow -For ssh root login allow
admin@OPT9603# set system services ftp enable-network -For ftp enable
admin@OPT9603# set system services stms server <STMS IP> -for STSM server IP entry
admin@OPT9603# set system services stms discovery enable -For stms discovery enable
admin@OPT9603# set network-element opt96xx lct-security-mode rw-access
-For LCT RW access
16
COMMISSIONING
USING LCT-STMS
17
LAN Details:
Connect LAN for LCT/Local port of OPT9603 & put below details in Laptop LAN
18
Launch LCT-SMTS(Use Latest Version)
LCT-STMS_V8.4R35.5_323154-X93354, Recent is V9.0
19
User: system
Password: eci
20
Go to tool Install NE
21
Click on connect
22
Go to DCN settings DCN Mode U will get 3 options
1.DCN Mode 2.Gateway 3.Ethernet only
23
If u select NE as Gateway need to fill the DCN & Gateway IP as
shown below
24
Hostname/IP/NE ID/Date as below:
25
Click on install and wait for few minutes and then click on OK
26
Click Ok again after Installation completed window pop-up
27
Check connectivity with the NE
28
IP Reachable
29
Mux will reboot after successful installation, click YES for reboot
30
Click OK on warning:
(Installation will be completed after reboot )
31
Node discovery after installation:
NE Discovery from STMS must be enable for NE discovery
Run below command after telnet DCC IP of NE(LCT port) via CLI
Set system services stms discovery enable (run from edit # prompt)
LAN Properties details will be same as for LCT-STMS Launch
Go to STMS domain Discover NE
32
Discover network element // discover NE with DCC IP only
Not required
33
34
Discovery completed
35
Shelf View
Right click on Node go to show Chassis to get shelf view
36
Card Assignment:
Right click on slot go to Assign the card
37
Select slot & relevant Card & Click FINISH
38
Port Configuration:
Configure the port as shown below
39
Select relevant port type & Click FINISH
40
Power level check
Right Click on relevant port & select optical parameter/Transciever parameter
41
42
43
Hardware Information
Right Click on card & select properties, will get SN & version details:
44
Alien Lambda configuration
Assign Artemis shelf with OPT96xx
45
Select proper slot/card/configuration during shelf configuration & click finish
46
Below marked section will be observed after shelf assignment
47
Assign card in Artemis
Show chassis:
48
Assign MXD card
Select proper MXD card & click set
49
Create fiber connectivity
Port 0 is for line port of MXD-8 & port 1 to 8 is for different 8 channels of MXD-8
50
Select unmanaged
Indicates port & frequency
These parameters can
configured as per plan
51
After selection unmanaged , select unspecified & Apply
52
Can check created fiber connectivity by clicking on
particular port ,then show fiber connectivity
53
Configure Alien Lambda
Right click on particulate port & select parameters
54
Go to Ochp Attributes & enable Alien Lambda then Apply
Alien Lambda configuration done.
Note: Cannot configure Alien Lambda without creating external fiber connectivity.
55
THANK YOU!