AC35-6
35kVA / 28 kW
POWERED by CUMMINS
DIESEL GENERATING SET 480/277 V,380/220V,220/127V- 60 Hz
MODEL AC35-6
kVA 35
Standby
Power kW 28
Pf. 0.8 kVA 32
Prime
kW 25.6
Standby: Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046 .
Prime: Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period. In accordance with ISO 8528,ISO 3046.
High quality, reliable and complete power unit
Compact design
Easy start and maintenance possibility
Every generating set is subject to a comprehensive test program which includes full load testing, checking and provision of all
control and safety shut down functions testing
Fully engineered with a wide range of options and accessories: Canopy, sound proof canopy and on-road trailer
Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
ENGINE
CUMMINS
Model 4B3.9-G2
Engine Power Output kWm 33
at rated rpm HP 44
Aspiration and Cooling Natural
Total Displacement Litre 3.9
No. of Cylinders and Build 4- Inline
Engine Speed rpm 1800
Bore and Stroke mmxmm 102x120
Compression Ratio 18:1
Governor Electronic
Fuel Consumption at full load L/hr 8.6
Fuel Tank Capacity Litre 180
Oil Capacity Litre 10.9
Coolant Capacity Litre 20
Radiator Cooling Air m³/min 145.2
Air Intake – Engine m³/min 2.58
Exhaust Gas Flow m³/min 4.914
Heavy duty Cummins diesel engine Cooling radiator and fan
Four stroke, water cooled, Natural Starter battery (with lead acid) including Rack and Cables
Direct injection fuel system Flexible fuel connection hoses and manual oil sump drain valve
Electronic Governor system Industrial capacity exhaust silencer and steel bellows
12/24 V D.C. starter and charge alternator Jacket water heater(at automatic models)
Replaceable fuel filter, oil filter and dry element air filter Operation manuals and circuit diagram documents
ALTERNATOR
Design Brushless single bearing, revolving field
Stator 2/3 pitch
Rotor Single bearing, flexible disc
Insulation System Class H
Standard Temperature Rise 125 - 163°C Continuous
Exciter Type Self Excited
Phase Rotation A (U), B (V), C (W)
Alternator Cooling Direct drive centrifugal blower fan
AC Waveform Total Harmonic Distortion No load < 1.5%. Non distorting balanced linear load < 5%
Telephone Influence Factor (TIF) <50 per NEMA MG1-22.43
Telephone Harmonic Factor (THF) <2%
Brushless, single bearing system, flexible disc, 4 poles Impregnation with tropicalised epoxy varnish
Insulation class H Solid state Automatic Voltage Regulator
Standard degree of protection IP21 (*IP22/IP23 is available.) Stator winding with 2/3 pitch for improved harmonics
Self-exciting and self-regulating
CONTROL SYSTEM
Control supervision and protection panel is mounted on the genset base frame.
The control panel is equipped as follows:
1. Auto Mains Failure Control Panel
Panel equipments:
Control with AMF module
Static battery charger
Emergency stop push button
DSE 6120
a) Generating set control module DSE6120 features: c) Alarms:
The module is used to monitor main supply and Over and Under Speed
starts and stops of a standby generating set Low and High Battery Volt.
Micro-processor based design Start and Stop Failure
Automatic control of main and generator contactors Charge fail
Monitors engine performance and AC power output LED Over Current
alarm indication Under / Over Generator Voltage
Front panel configuration of timers and alarm trip points Low Oil Pressure
4 configurable analogue/digital inputs,8 configurable digital inputs Emergency stop
6 configurable DC outputs High engine temperature
Easy push button control d) LED indications
STOP/RESET - MANUAL - AUTO - TEST – START Mains available
b) Metering via LCD display: Generator available
Generator Volts (L-L / L-N) Generator kVA Mains on load
Engine oil pressure (PSI-Bar) Generator kW Generator on load
Generator Ampere (L1,L2,L3) Generator Cos (σ)
Engine temperature (°C&°F)
Generator Frequency (Hz) 2. Power Outlet Terminal Board Mounted
Plant battery volts on the Gen-set Base Frame
Engine hours run
Mains Volts (Ph-Ph/Ph-N)
CHASSIS
The complete gen-set is mounted as whole on a heavy-duty fabricated, steel base frame
Anti-vibration pads are fixed between the engine/ alternator feet and the base frame
Base frame design incorporates an integral fuel tank (Up to 1000 kVA)
The generating set can be lifted or carefully pushed / pulled by the base frame
Dial type fuel gauge and drain plug on the fuel tank
Forklift pockets within base frame (up to 500kVA)
DIMENSIONS
OPEN TYPE
DIMENSIONS (LxWxH) mm 2015x950x1411
DRY WEIGHT kg 720
SOUND ATTENUATED TYPE
DIMENSIONS (LxWxH) mm 2282x1008x1532
DRY WEIGHT kg 940
CANOPY
All canopy parts are designed with modular principles Exhaust silencer is protected against environment influences
Without welding assembly Thermally insulated engine exhaust system
Doors on each side Emergency stop push button is installed outside of the canopy
All metal canopy parts are painted by electrostatic Easy lifting and moving
polyester powder paint Easy maintenance and operation
Aksa Power Generation
Ruzgarlibahce Mahallesi - Özalp Cikmazi No:10 34805 Kavacik Beykoz - Istanbul / Turkey
Tel:+90 212 444 46 30 E-mail:
[email protected] www.aksa.com.tr
Aksa Power Generation is a member of www.aksa.com.tr