LEO+ and LEO+ Baby Stent Overview

The document provides detailed ordering information for the Low profile Leo+ baby stents, which are designed for treating small arteries down to Ø 1.5 mm. It includes specifications such as reference numbers, vessel diameters, stent lengths, and compatible delivery catheters. The Leo+ stents are CE marked for use in treating intracranial aneurysms and are manufactured by BALT Extrusion SAS.

Uploaded by

ferronatto121
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
234 views2 pages

LEO+ and LEO+ Baby Stent Overview

The document provides detailed ordering information for the Low profile Leo+ baby stents, which are designed for treating small arteries down to Ø 1.5 mm. It includes specifications such as reference numbers, vessel diameters, stent lengths, and compatible delivery catheters. The Leo+ stents are CE marked for use in treating intracranial aneurysms and are manufactured by BALT Extrusion SAS.

Uploaded by

ferronatto121
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ordering information

Low profile Leo+ baby offers the possibility to treat small arteries down to Ø 1,5 mm. leo +
&
Reference Vessel Ø
(mm)
Stent’s length
at nominal Ø
(mm)
Unconstrained stent

Ø (mm) Length (mm)


Compatible
delivery
catheters
leo + baby
Leo+ baby 2,0 LEO. 2,0x12 12 8 the authentic
LEO. 2,0x18 1,5 to 2,5 18 2,8 12 VASCO+10 braided stent
LEO. 2,0x25* 25 16

Leo+ baby 2,5 LEO. 2,5x12 12 8

LEO. 2,5x18 18 12
LEO. 2,5x25 2,0 to 3,1 25 3,2 16 VASCO+10

LEO. 2,5x30* 29 19
LEO. 2,5x35* 35 23

Leo+ baby 3,0 LEO.3.0x12 12 9


LEO. 3,0x18 18 13
2,5 to 3,6 3,8 VASCO+10
LEO. 3,0x25 25 16
LEO. 3,0x35 35 24

Leo+ 3,5 LEO. 3,5x12 12 9


LEO. 3,5x18 18 12
LEO. 3,5x25 25 17
3,10 to 4,25 4,4 VASCO+21
LEO. 3,5x30 30 19
LEO. 3,5x35 35 24
LEO. 3,5x50 50 36

Leo+ 4,5 LEO. 4,5x15 15 12


LEO. 4,5x20 21 15
LEO. 4,5x25 26 18
LEO. 4,5x30 4,25 to 5,30 30 5,4 21 VASCO+25
LEO. 4,5x40 40 28
LEO. 4,5x50 51 37
LEO. 4,5x75 75 55

Leo+ 5,5 LEO. 5,5x25 26 18


LEO. 5,5x30 31 21
LEO. 5,5x35 36 26
5,30 to 6,50 6,7 VASCO+28
LEO. 5,5x50 52 35
LEO. 5,5x60 60 42
LEO. 5,5x75 75 51

*Manufactured on demand.

Reference: 1. Internal data


The self-expandable LEO+/LEO+ Baby stent is designed for the treatment of intracranial aneurysms in association with embolization coils. Class
III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT Extrusion
SAS. Carefully read the instructions for use before use. First CE marking:2007 (LEO+),2012 (LEO+Baby). VASCO+ is a reinforced micro-catheter
intended for injection of diagnostic or therapeutic product, to position pushable coils “SPIRALES” or detachable coils especially the ones of MDS
« mechanical detachment system », for the use of the self-expanding stent LEO+ or SILK+. Class III CE0297 in compliance with Medical Device
Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT Extrusion SAS. Carefully read the instructions for use before
use. First CE marking:2004.
The content of this document, in particular data, information, trademarks and logos is BALT SAS and affiliates’ sole property. © 2019 BALT SAS
and affiliates, all rights reserved. All representation and/or reproduction, whether in part or in full, is forbidden and would be considered a
violation of BALT SAS and affiliates’ copyrights and other intellectual proprietary rights. This document with associated
pictures is non-contractual and is solely dedicated to healthcare professionals and BALT’s distributors (BALT’s
supplier’s distributors). It cannot be distributed or given to patients. The products commercialized by BALT
shall exclusively be used in accordance with the instructions for use included in the boxes.
DC015GB (01/2019)

Balt
10, rue de la Croix Vigneron, 95160 Montmorency France
Tel. : +33 (0)1 39 89 46 41
Fax : +33 (0)1 34 17 03 46
[Link]
leo +
& leo + baby

aneurysm treatment
More than

Designed for the treatment of intracranial aneurysms in


association with embolization coils
40 000
Leos deployed
around the world
since 2003

Customization for
tailor-made solutions
Flexibility
thanks to the nickel titanium materials

Conformability
given by the sliding-cell technology

Smooth wall apposition


as a result of the rounded short flared ends

Radial force for optimal


coil mass support
Intraluminal support & neck coverage
thanks to the 16 braided wires

Accurate positioning
Visibility
two helical markers on the

16
entire body of the stent

Resheathability
up to 90% of deployed length1

Flow diversion effect


Bouillot et al., Computational fluid
dynamics with stents: quantitative
braided
comparison with particle image
wires
resheathable velocimetry for three commercial off

90
the shelf intracranial stents

up to
%
J NeuroIntervent Surg 2016;
8:309–315”

of deployed
length1

You might also like