0% found this document useful (0 votes)
114 views19 pages

NLC Sedro

The Sedro elevator system features various operational modes including Down Collective and Duplex, with a fault capture capability that displays over 200 fault messages. It provides detailed status information, door control options, and customizable parameters for operation, including inspection mode and emergency stop functions. The system also includes a user-friendly LCD control interface for monitoring and adjusting settings.

Uploaded by

Laly
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views19 pages

NLC Sedro

The Sedro elevator system features various operational modes including Down Collective and Duplex, with a fault capture capability that displays over 200 fault messages. It provides detailed status information, door control options, and customizable parameters for operation, including inspection mode and emergency stop functions. The system also includes a user-friendly LCD control interface for monitoring and adjusting settings.

Uploaded by

Laly
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Sedro Main features

Type Single – Dual Speed – VVVF – Hydraulic


Mode Down Collective, Full Collective ,Duplex
Fault Capture Display more than 200 fault messages
Status information Status of the Elevator, door, mode and Limit switch Up & Down are displayed.
Fault count Calculate fault of Type 2.
Shaft information End of the Shaft in the Up, Down Direction.
Show Down in Final Stop in Up, Down Direction.
Level Zone
Elevator Position is saved at each stop
Indicator signal Gray, Binary 7Segment and Decimal.
Number of Stops • 12 stops Down Collective , Duplex
• 8 Full Collective .
• 24 stops Simplex
• 24 stops Down Collective with cabin board serially connected to the panel
board
• 12 stops Full Collective with cabin board serially connected to the panel board

Door Type Swinging, Automatic and ½ Automatic


Door Controls 3 input are: automatic door close switch, automatic door open switch & close circuit
Door parking Status Parking Opened or Closed door
Floor Stop Time Time of Stopping at each station
Home floor Home Floor Number
Car Light Light timer
Home Floor timer Automatic Return to Home floor after preset time
Inspection Mode Elevator goes to inspection/service mode
No Load At preset # will Cancel all the inside calls if the door wasn’t opened
Emergency Stop It will stop immediately and cancel all inside calls
Fireman Operation It will Cancel all calls and go to Fireman floor
LCD Control
Main Screen
This is the main screen of the Data pad, you can go either to browse all errors occurring or to edit all
parameters, and you can also monitor the elevator status, direction and floor number.

Status Insp. _ Floor Number

LUP: 0 LDN: 0 DO DO DO or DC

Status: Stop or Travel


LUP: Limit Switch up 0/1
LDN: Limit Switch down 0/1
(DO/DC): Door Open or Door Close.
FL: Floor Number
Select Dec. key to enter to parameter or functions or fault screens.

Parameter Menu
In this menu we can scroll over parameters by pressing Inc & Dec keys.
To select a parameter to change, press Select key.
After selecting the parameter, we can edit its value by pressing either Inc or Dec key.
The parameter’s value is saved by pressing Select key.

Parameter Name FLr Stp Tmr 01 Parameter Number


Value = 03 sec Parameter Value

To exit from the parameter menu go to the exit page and press Select key.

Fault Screen:
In this screen you can see all error occurred in the elevator from the last reset of error.
Example: Unblock
00 -
01 – Example: Jammed / Pulse

Inc. Key: go up
Dec. Key: go down

We can exit to main screen by pressing select key.

2
Functions Screen:

FL Call
Call Number
SDN SUP 00 00

Floor Number

SDN: Service down, down / slow


SUP: Service up, up / slow
FL: Floor
To exit from the function screen, select E for the call number by pressing the Inc. key

3
Sedro Parameters:

ITAL GEARS SYMBOL


Parameter number ON LCD Default Range
(13 character)

1. Flr Stp Tmr 3 1 Æ 255 sec


Swinging / Automatic/
2. Door Type Swinging
½ Automatic
3. Door Zone None None / Installed NC / Installed NO
4. Mx Cnt Of Err 0 0 Æ 202
5. UG Floor 0 0Æ9

6. Rturn Floor 0 0 ,.., Last Floor


1 Æ 1275 sec
7. Rturn Flr Tmr 0
(1=5sec)
8. Energy Save 0 1Æ9
9. Collective Down Down / Full
10. Reset On Pwr Enable Enable / disable
11. Erase Fault N/A

AUTOMATIC DOOR
12. Door Motor Tm 6 1 Æ 15 sec
13. Door Status Close Close / Open
14. Light Time 5sec 1 Æ 255sec

SECONDARY

15. Keep Close Disable Enable / disable

16. Retry Locking 3 1 Æ 255 Times


1 Æ 255 sec
17. Rtry Lock Tmr 3

18. Bsment Blnce 0


19. Magnet Timout 20 1 Æ 255 sec
20. Stop Lock Tmr 5 1 Æ 255 sec
21. PTC Disable Disable \ Enable
22. Indctor Type Gray Gray / binary / 7 segment

23. Over Lmt Swt Enable Enable / Disable


24. Service Days 0
25. Serial Number 15
26. Version 001.065/050912
27. VVVFHy Stp Dly 0 0 Æ100ms
28. VVVF Strt Dly 0 0 Æ100ms
29. E Output Inspection Inspection / Hydraulic Main
HYDRAULIC AND VVVF ELEVATOR

30. Hydr Strt Tm 0 0 Æ 100ms


31. Door Busy 5sec
32. Psnger Cpcty 0
AC 2spd/Hydrlc /Hydraulic 1 / VVVF/ VVVF 3
33. Drv / VVVF Type AC 2spd/Hydrlc
speed
34. Board Type None None / Cabin / Panel

35. User Pass 00000000


36. Fact. Default

4
Fault Description:

Error Displayed on Description Controller Action Solution


LCD
Elevator is Jammed Motor powered but Block Check the Brake or Pines,
car didn’t move Turn electricity off then on.
SDFS Pulse Missed Pulses. Reset and make home Check the pines or magnet.
trip

Limit switch Up LMTSW_UP fault Block Check Switch up,


Turn electricity off then on.
Limit switch Down LMTSW _DN fault Block Check Switch down,
Turn electricity off then on.
Limit switch up & LMTSW _UP fault Block Check Switch up & Down,
Down & LMTSW _DN Turn electricity off then on.
fault
Gamma Retiring Cam fail in Cancel calls Check Retiring Cam
contactor up
Yale Yale is opened Cancel calls Check Yale

Door Open in travel Door Lock circuit Wait for lock circuit, Check Yale
open during travel Cancel calls if fault
persists more than 5 sec
Aux NC Safety and Ready Waits for Ready circuit Check Aux Nc or Yale
circuits are open to close
Safety Jammed Contactor up or Waits for Ready circuit Check Contactor UP or Down
down jammed to close
System Timeout Count days of Block Contact the System Administrator.
operation expired
Stop Key Stop key Error Complete cycle Check Stop Key.
PTC overheating Motor Temperature Elevator will not take Wait for motor to cool
exceeds limits. calls after the first stops. Or disable PTC.

Sedro Controller is Capable of storing more than 200 faults that can
be displayed on the LCD screen.

5
7 Segment Display:
Displaying Error in 7 segments:

Error Display Output


A,B,C,E,F,G

Limit Switch UP (A)

C,D,E,F,G

Limit Switch Down (B)

A,D,E,F

Limit Switch UP & Down (C)

B,C,D,E,G

System Timeout (D)

B,C,

Elevator Jammed (E)

A,E,F,D

Max Aux (F)

6
CONNECTION DIAGRAM UP TO 12/24 STOPS COLLECTIVE/DUPLEX
( --) (-22VDC)
(+) (+22VDC) 11N
17 Volt AC 17V 10N
17Volt AC 17V 9N

OutSide Calls 0N ----> 11N


W: 8.26 IN → 21cm L: 5.5 IN → 14cm
8N
Slow 1 7N
Down 2 6N
UP 3 5N
High 4 4N
5 3N
OUTPUTS
Car light
Spare 6 2N
com1 7
LCD screen 1N
0N
close 8 11K
Open 9 10K
Com2 10 9K

InSide Calls 0K ----> 11K


8K
7K
SELECT DEC INC 6K
5K
VVVF 1 4K
Inputs

Xon 2 3K
Xoff 3 2K
VVVF Error 4 INPUT OUTPUTS 1K
Duplex Serial 0K
5 6 7 8 119 10
12 13 14 15 16 17 18 19 20 21 22 23 24 11 12 13 14 15 16 17 18 19 20 21 22 23
Drop Close Force ARO
UP DN LSUP LSDN LZ SEN
Out
FULL STOP Fireman
circuit Cls
EO EC PTC PTC A1 B1 A2 B2 A B C D E F G UP
ARO DN (1) Indicator (-) Spare out Spare out
7Segment ‐ Binary ‐ Gray
Outputs Inputs Active Hi & Low
1- Slow 1‐ VVVF: VVF Control Signal
2- Down 22‐ Spare Out 2- Xon: Contactor down direction
3- UP 23- Spare Out 3- Xoff: Contactor Up direction 21‐ A1: Dulpex Communication
4- High 4- VVVF Error: 22‐ B1: Duplex Communication
5- Car Light 5- UP: Service UP 23‐ A2: Serial Communication
6- Spare 6- DN: Service Down 24‐ B2: Serial Communication
7- Com1 7- LSUP: Limit Switch Up Direction
8- Close 8- LSDN: Limit Switch Down Direction
9- Open 9- LZ: Level Zone
10- Com2 10- SEN: Service Enable
11- A 11- Drop Out: Cancel outside calls
7Segment-Binary-Gray

12- B 12- FULL: Full Load


Active Hi & Low

13- C 13- STOP: Emergency Stop


14- D 14- Fireman: Fireman switch
15- E 15- Close Circuit: Active high when the doors circuit are completely engaged
16- F 16- Force Cls: Force Automatic Door for closing and canceling
17- G 17- EO: End of Opening
18- ARO UP 18- EC: End of Closing
19- ARO DN 19- PTC: Active Low
20- (1) Indicator 20- PTC: Active Low
7
21- (-)

ITAL GEARS Copyright ® 2012


5 4 3 2 1

12 STOPS, DOWN COLLECTIVE (+22VDC) (+22VDC)


H6 H6
AUTOMATIC DOOR, AC 2 SPEED OUTSIDE CALLS INSIDE CALLS
11 11

H1(+60VDC) 10 10

OT_UP SS GOV or 9 9
SG SGW Q1 H4(+220VDC)
8 8
D
1 2 1 2 1 2 1 2 1 2 1 2 1 2 or D

DO OT_DN H5(+110VDC) 7 7

6 6
Q11
5 5

4 4

(+22VDC) 3 3
Q11 H6
0VDC 2 2
KCup

KCdn

KClo

1 1
2

0 0
1

INDICATOR 7 SEGMENT,
1

(+22VDC)
COM DECIMAL, GRAY 0VDC H3 0VDC SDN
N.C.
* * * * * * * OR BINARY CODE
INSPECTION
Clo

Cdn

Cup

Chi

Rlt

Rop

Rcl
BUTTONS
SUP
SLOW DOWN UP HIGH NC LIGHT OPEN CLOSE COM2 G F E D C B A (-) (+) GND

ARO UP
ARO DN
11N 10N 9N 8N 7N 6N 5N 4N 3N 2N 1N 0N 11K 10K 9K 8K 7K 6K 5K 4K 3K 2K 1K 0K

C C

CEDRO CONTROLLER

STP-FORCE CLSE
CLSE CIRC

STP-FIRE
DOR EO

STP-LZ

SpIn 1

N.C. SpIn 2
DOR EC
UP DN LSUP LSDN SEN STP XOFF XON PTC 17V~

(17VAC)
N.C.
ROP

0VAC
K1Cdn
1

CE
1

FIRE
K1Cup
2

K1Cdn
2

1
PC

LZ
1

1
SEN

PTC
2

2
2

H2

2
K1Cup

FCL EO EC
1

1
1

CS DJ

1
2

2
2

OL H3 H6
H3 H6 (+22VDC) (+22VDC)
2

(+22VDC) (+22VDC)

MONOSTABLE MAGNETIC SWITCH


B
H6 H6 B

(+22VDC) (+22VDC)

(*): do not install diodes with contactors if Q1 was 220 VAC or 110 VAC

DO: Door contact mecanical switch RCL: Close door relay EO: Limit switch end of opening
OT-UP: Over travel up mechanical limit switch UP: Pulse up EC: Limit switch end of closing
OT-DN: Over travel down mechanical limit switch DN: Pulse down LZ: Level zone
SS: Stop service mechanical switch LSUP: limit switch up FIRE: Fireman switch
SG: Speed governor on top of the cabine LSDN: limit switch down PTC: Motor PTC
SGW: Speed governor weight SEN: Service enable switch COM: If the board includes relay
GOV: Governor in machine mechanical switch SUP: Inspection button this output is connected to 0VAC
CLO: Slow speed contactor SDN: Inspection button
Cdn: Down direction contactor CS: Car tep switch
CUP: Up direction contactor CE: Car emergency push button
Chi: High speed contactor K1CUP: Auxiliary switch for up direction contactor
KCUP: Auxiliary switch for up direction contactor K1Cdn: Auxiliary switch for down direction contactor
should be [Link] OL: Overload switch
KCLO: Auxiliary switch for low speed contactor DJ: Door jam switch
should be N.C PC: Photocell limit switch
A
ROP: Open door relay FCL: Push button close door immediately A

page description: project: date:


September 14, 2012
12 STOPS, DOWN COLLECTIVE
ITAL GEARS CEDRO CONTROLLER page:
AUTOMATIC DOOR, AC 2 SPEED
1 of 11

5 4 3 2 1
5 4 3 2 1

(+22VDC) (+22VDC)
12 STOPS, DOWN COLLECTIVE H6 H6
OUTSIDE CALLS INSIDE CALLS
11 11

10 10

D
H1(+60VDC) D

LD OT_UP SS GOV or 9 9
SG SGW H4(+220VDC) 8 8
1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

DO OT_DN Q1 or 7 7
H5(+110VDC)

2
* Q11 6 6

1
Rdw
5 5

4 4
0VDC
3 3

(+22VDC) 2 2
Q11
H6

2
2
2
0VDC 1 1

1
1
1
0 0

KCup
KCdn
KClo
(+22VDC)
INDICATOR 7 SEGMENT, H3
COM GRAY, DECIMAL SDN
N.C.
* * * * * OR BINARY CODE 0VDC 0VDC
* INSPECTION
BUTTONS

Rlt

Clo
Cdn
Cup
Chi
Rcm
SUP

N.C.
SLOW DOWN UP HIGH NC LIGHT OPEN COM2 G F E D C BA (-) (+) GND 11N 10N 9N 8N 7N 6N 5N 4N 3N 2N 1N 0N 11K 10K 9K 8K 7K 6K 5K 4K 3K 2K 1K 0K

C C

ARO UP
ARO DN

CLOSE/CAM
CEDRO CONTROLLER

STP-LZ
STP-FIRE
STP XOFF XON 17V~

CLSE CIRC
SpIn 1

DOR EC
UP DN LSUP LSDN SEN PTC

1
1

N.C. FORCE CLSE


N.C. DOR EO
N.C.
N.C.
N.C. SpIn 2

1
1
1
1
2

2
1
CE
0VAC

1
1
FIRE

K1Cdn

2
2
2
2
(17VAC)

PTC

LZ

1
2

2
2

SEN
Rdw

2
H2

K1Cup

1
K1Cdn

1
2
CS

2
1

K1Cup
OL

2
H3 H6
H6 H6 (+22VDC) (+22VDC)
B B

(+22VDC) (+22VDC)
MONOSTABLE MAGNETIC SWITCH H6 H6
(+22VDC) (+22VDC)
(*): do not install diodes with contactors if Q1 was 220 VAC or 110 VAC

LD: Lock door contact CUP: Up direction contactor CS: Car step awitch
DO: Door contact mechanical switch Chi: High speed contactor CE: Car emergency push button
OT-UP: Over travel up mechanical limit switch KCdn: Auxiliary switch for down direction contactor should be [Link] K1CUP: Auxiliary switch
OT-DN: Over travel down mechanical limit switch KCLO: Auxiliary switch for low speed contactor should be N.C. for up direction contactor
SS: Stop service mechanical switch RLt: Light relay K1Cdn: Auxiliary switch
SG: Speed governor on top of the cabine RCm: CAM relay for swinging door(Gamma) for down direction contactor
SGW: Speed governor weight UP: Pulse up OL: Overload switch
GOV: Governor in machine mechanical switch DN: Pulse down LZ: Level zone
Rdw:: Door contact relay LSUP: limit switch up FIRE: Fireman switch
CLO: Slow speed contactor LSDN: limit switch down PTC: Motor PTC
A
Cdn: Down direction contactor SEN: Service enable switch COM: If the board includes relay A

SUP: Service up switch this output is connected to 0VAC


KCUP:Auxiliary switch for up direction contactor should be [Link].

page description: project: date:


June 14, 2012
ITAL GEARS SWINGING DOOR, AC 2 SPEED CEDRO CONTROLLER
page:
12 STOPS, DOWN COLLECTIVE 2 of 11

5 4 3 2 1
5 4 3 2 1

12 STOPS, DOWN COLLECTIVE (+22VDC) (+22VDC)


H6 H6
OUTSIDE CALLS INSIDE CALLS
AUTOMATIC DOOR AC 2 SPEED
11 11
D D

H1(+60VDC) 10 10

OT_UP1 SS1 GOV1 Q1 or 9 9


SG1 SGW1 H4(+220VDC) 8 8
1 2 1 2 1 2 1 2 1 2 1
or 2 1 2

DO1 OT_DN1 H5(+110VDC) 7 7

6 6
Q11
5 5
4 4

3 3
(+22VDC)
Q11 H6 2
0VDC 2

2
2
1

2
1

1
1
0 0

1
INDICATOR 7 SEGMENT,

KStar
(+22VDC)

KValve
KDelta
COM DECIMAL, GRAY 0VDC H3 0VDC SDN
N.C.
* * * * * * * OR BINARY CODE
INSPECTION
BUTTONS

Chi
Rlt
Rop
Rcl

Star

Delta
Valve
SUP
SLOW DOWN UP HIGH NC LIGHT OPEN CLOSE COM2 G F E D C BA (-) (+) GND 11N 10N 9N 8N 7N 6N 5N 4N 3N 2N 1N 0N 11K 10K 9K 8K 7K 6K 5K 4K 3K 2K 1K 0K
C C

ARO UP
ARO DN
CEDRO CONTROLLER

STP XOFF XON 17V~

CLSE CIRC
STP-FORCE CLSE
DOR EO
STP-LZ
SpIn 1

DOR EC
STP-FIRE
UP DN LSUP LSDN SEN PTC

1
ROP
N.C.
N.C. SpIn 2

1
1
1
1
CE

2
1
1
1
0VAC

1
1
PC

2
2
2
2
(17VAC)

LZ
PTC

1
2
2
2

2
2
FIRE

2
2

SEN
H2

1
1

1
FCL EO EC

1
1

K1Star

K1Valve
CS DJ

2
2

2
1

K1Star K1Valve
B
OL H6 H6 B

2
H3 H6
(+22VDC) (+22VDC) (+22VDC)
(+22VDC)
MONOSTABLE MAGNETIC SWITCH
H6 H6
(+22VDC) (+22VDC)

(*): do not install diodes with contactors & relays if Q1 was 220 VAC or 110 VAC

DO1: Door contact mecanical switch Kstar: Auxiliary switch for star contactor should be [Link]. K1star: Auxiliary switch for star contactor
OT-UP1: Over travel up mechanical limit switch Rlt: Light relay K1valve: Auxiliary switch for valve relay
OT-DN1: Over travel down mechanical limit switch Rop: Open door relay OL : Overload switch
SS1: Stop service mechanical switch Rcl: Close door relay DJ : Door jamp switch
SG1: Speed governor on top of the cabine UP: Pulse up PC : Photocell limit switch
SGW1: Speed governor weight DN: Pulse down FCL: Push button close door immediately
GOV1: Governor in machine mechanical switch LSup: Limit switch up EO : Limit switch end of openning
Delta: Delta contactor LSDN: Limit switch down EC : Limit switch end of closing
Valve: Valve relay SEN: Service enable switch LZ : Level zone
star: Star contactor SUP: Inspection button Fire: Fireman switch
Chi: High speed contactor SDN: Inspection button PTC: Motor PTC
A A
KDelta: Auxiliary switch for delta contactor should be N.C CS: Car step switch COM: If the board includes relay this
Kvalve: Auxiliary swith for valve relay should be normally closed CE: Car emergency push button output is connected to 0VAC

page description: project: date:


June 14, 2012
12 STOPS, DOWN COLLECTIVE
ITAL GEARS CEDRO CONTROLLER
page:
AUTOMATIC DOOR AC 2 SPEED 3 of 11

5 4 3 2 1
5 4 3 2 1

(+22VDC) (+22VDC)
H6 H6
12 STOPS, DOWN COLLECTIVE
OUTSIDE CALLS INSIDE CALLS
11 11

10 10
H1(+60VDC)
LD1 OT_UP2 SS2 GOV2 or 9 9

D
SG2 SGW2 H4(+220VDC) 8 8 D

1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

DO2 OT_DN2 Q1 or 7 7
H5(+110VDC)

2
* Q11 6 6

1
Rdw
5 5

4 4
0VDC
3 3

(+22VDC) 2 2
Q11

2
2
2
0VDC H6 1 1

1
1
1
(+22VDC) 0 0

KStar
KValve
KDelta
INDICATOR 7 SEGMENT, H3
COM GRAY, DECIMAL SDN
N.C.
* * * * * OR BINARY CODE 0VDC 0VDC
* INSPECTION
BUTTONS

Rlt

Star
Chi

Delta
Valve
Rcm
SUP

N.C.
11N 10N 9N 8N 7N 6N 5N 4N 3N 2N 1N 0N 11K 10K 9K 8K 7K 6K 5K 4K 3K 2K 1K 0K
SLOW DOWN UP HIGH NC LIGHT OPEN COM2 G F E D C BA (-) (+) GND

ARO UP
ARO DN
C C

CLOSE/CAM
CEDRO CONTROLLER

STP-LZ
STP-FIRE
STP XOFF XON 17V~

CLSE CIRC
SpIn 1

DOR EC
UP DN LSUP LSDN SEN PTC

1
1
1

N.C. FORCE CLSE


N.C. DOR EO
N.C.
N.C.
N.C. SpIn 2

1
1
1
1
2

2
CE

LZ
0VAC

2
2

1
1
FIRE

2
2
2
2
(17VAC)

PTC

1
2
2

SEN
Rdw

2
H2

1
K1Star

K1Valve

2
CS

2
1
H3 H6

K1Star K1Valve
OL

2
H3 H6 (+22VDC) (+22VDC)
(+22VDC) (+22VDC)
H6 H6
B (+22VDC) B
MONOSTABLE MAGNETIC SWITCH (+22VDC)
(*): do not install diodes with contactors & relays if Q1 was 220 VAC or 110 VAC

LD1: Lock door contact Star: Star contactor CE : Car emergency push button
DO2: Door contact mechanical switch Chi: High speed contactor K1star: Auxiliary switch for star contactor
OT-UP2:Over travel up mechanical limit switch KDelta:Auxiliary switch for delta contactor should be N.C
K1valve: Auxiliary switch for valve relay
OT-DN2:Over travel down mechanical limit switch Rlt: Light relay OL : Overload switch
SS2: Stop service mechanical switch Rcm: CAM relay for swinging door(Gamma) LZ : Level zone
SG2: Speed governor on top of the cabine UP: Pulse up FIRE: Fireman switch
SGW2: Speed governor weight DN: Pulse down
PTC: Motor PTC
LSUP: Limit switch up COM: If the board includes relay
GOV2: Governor in machine mechanical switch
Rdw:: Door contact relay LSDN: Limit switch down this output is connected to 0VAC
Delta: Delta contactor SEN: Service enable switch
Valve: Valve relay SUP: Inspection button
Kstar: Auxiliary switch for star contactor should be [Link]. SDN: Inspection button
A A

Kvalve:Auxiliary switch for valve relay should be [Link]. CS: Car step switch

page description: project: date:


June 14, 2012
ITAL GEARS SWINGING DOOR AC 2 SPEED CEDRO CONTROLLER
page:
12 STOPS, DOWN COLLECTIVE
4 of 11

5 4 3 2 1
5 4 3 2 1

(+22VDC) INSIDE CALLS


H6
24 STOPS DOWN COLLECTIVE
23

Parameter (34) must be set to Cabin 22

21
D D

20

19
CABIN BOARD DIAGRAM 18

17

SERIAL CONNECTION 16

15

14

13

12

11

10

5
C C

3
(+22VDC)
Q11 H6
0VDC 2

0
INDICATOR 7 SEGMENT,
(+22VDC)
COM DECIMAL, GRAY H3 SDN
N.C. 0VDC 0VDC
* * * OR BINARY CODE
INSPECTION BUTTONS
Rlt

Rop

Rcl

SUP
11N 10N 9N 8N 7N 6N 5N 4N 3N 2N 1N 0N 11K 10K 9K 8K 7K 6K 5K 4K 3K 2K 1K 0K
NC LIGHT OPEN CLOSE/GAMMA COM2 G F E D C BA (-) (+) GND
ARO UP

ARO DN

CEDRO CONTROLLER A2
STP-FORCE CLSE

B2 TO PANEL BOARD

B B
CLSE CIRC

STP-FIRE
DOR EO

STP-LZ

SpIn 1

N.C. SpIn 2
DOR EC

UP DN LSUP LSDN SEN STP PTC 17V~

(17VAC)
N.C.
ROP

0VAC
CE
1

FIRE
2

1
PC
LZ
SEN

PTC
2

2
H2
2

FCL EO EC
1
1

CS DJ
1

1
2
2

OL H6 H6
H3 H6
2

(+22VDC) (+22VDC)
(+22VDC) (+22VDC)

MONOSTABLE MAGNETIC SWITCH H6 H6


(+22VDC) (+22VDC)

A A

page description: project: date: September 14, 2012

ITAL GEARS 24 STOPS DOWN COLLECTIVE CEDRO CONTROLLER


page:
CABIN BOARD DIAGRAM 5 of 11

5 4 3 2 1
5 4 3 2 1

(+22VDC) OUTSIDE CALLS


24 STOPS DOWN COLLECTIVE H6

Automatic Door/Swinging, AC 2 Speed 23

22

Parameter (34) must be set to Panel


21
D D
20

19

PANEL BOARD DIAGRAM 18

17

SERIAL CONNECTION 16

15

14

13

12
H1(+60VDC)
LD3 OT_UP5 SS5 GOV5 or 11

SG5 SGW5 H4(+220VDC) 10


1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

DO5 OT_DN5 Q1 or 9
H5(+110VDC)
* Q11 8
2
Rdw
1

6
Manual Only 5
0VDC
C C

3
(+22VDC)
Q11 H6
0VDC 2
KStar

KValve

KDelta

1
2

0
1

INDICATOR 7 SEGMENT,
1

(+22VDC)
COM DECIMAL, GRAY H3 SDN
N.C. 0VDC 0VDC
OR BINARY CODE
Delta

Valve

* * * * * * *
Star

INSPECTION BUTTONS
Chi

Rlt

Rop

Rcl

SUP
11N 10N 9N 8N 7N 6N 5N 4N 3N 2N 1N 0N 11K 10K 9K 8K 7K 6K 5K 4K 3K 2K 1K 0K
SLOW DOWN UP HIGH NC LIGHT OPEN CLOSE COM2 G F E D C B A (-) (+) GND
ARO UP

ARO DN

CEDRO CONTROLLER A2
STP-FORCE CLSE

B2 TO CABIN BOARD
CLSE CIRC

B B

STP-FIRE
DOR EO

STP-LZ

SpIn 1

N.C. SpIn 2
DOR EC

UP DN LSUP LSDN SEN STP XOFF XON PTC 17V~

(17VAC)
K1Star K1Valve

N.C.
ROP

0VAC
1

CE
K1Valve
1

FIRE
2

K1Star
2

1
PC
LZ
SEN

PTC
2

2
2

H2
2

FCL EO EC
1

1
1

CS DJ
1

1
2

2
2

OL H6 H6
H3 H6
2

(+22VDC) (+22VDC)
(+22VDC) (+22VDC)

MONOSTABLE MAGNETIC SWITCH H6 H6


(+22VDC) (+22VDC)

A A

page description: project: date: September 14, 2012

ITAL GEARS 24 STOPS DOWN COLLECTIVE CEDRO CONTROLLER


Automatic Door/Swinging, AC 2 Speed page:
6 of 11

5 4 3 2 1
5 4 3 2 1

12 STOPS FULL COLLECTIVE


SERIAL CONNECTION

D D

(+22VDC)
DUPLEX DP
DP
CABIN CARD
11
LIFT A LIFT B 10
P P 9
8
GND GND 7
6
5
Push Button Diagram 4
3 + 3
C 2 C

1
+ 1
0
+
2 GND

A2 CEDRO CONTROLLER 11K 10K 9K 8K 7K 6K 5K 4K 3K 2K 1K 0K

B2 CABIN BOARD

(+22VDC) (+22VDC)
DP PANEL BOARD DP PANEL BOARD
11 11
10 10
SERIAL CONNECTION

9 9
B
8 8 B

7 7
6 6
5 5
4 4
3 3
2 2
1 1
0 0
GND GND

A2 B2 11N 10N 9N 8N 7N 6N 5N 4N 3N 2N 1N 0N 11K 10K 9K 8K 7K 6K 5K 4K 3K 2K 1K 0K


CEDRO CONTROLLER
PANEL BOARD
A A

page description: project: date:


September 14, 2012

12 STOPS FULL COLLECTIVE


CEDRO CONTROLLER
ITAL GEARS SERIAL CONNECTION
page:
7 of 11

5 4 3 2 1
5 4 3 2 1

OUTPUTS- AC 2 SPEED
LD DO OT_UP OT_DN SS GOV
SG SGW H1 (+60VDC)/ H4 (220VAC)/ H5 (110VAC)
1 2
SWINGING DOOR 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Q1

AUTOMATIC DOOR
D D
(*)

Q11 AUTOMATIC DOOR

2
Rdw

1
L1 L2 L3

0VDC

Q11 Q11 Q11

AUTOMATIC DOOR Rcl Rop


2

2
KCup KCdn KClo SWINGING DOOR
COM
1

* * * * *
* * *
Rcm Rcl Rop Rlt F-1 F-2 F-3
C
Cdn Cup Clo Chi C

DOWN UP SLOW HIGH CLOSE/CAM OPEN CLOSE/CAM CAR LIGHT COM2

CEDRO CONTROLLER
M 3~

(*): do not install diodes with contactors if Q1 was 220 VAC or 110 VAC

LD: Lock ddor contact Clo: Slow speed relay


B B

DO: Door contact mechanical switch Chi: High speed contactor


OT_UP: Over travel up mechanical limit switch Kclo: Auxiliary switch for low speed contactor should be N.C
OT_DN: Over travel down mechanical limit switch Rcm: CAM relay for swinging door
SS: Stop service mechanical switch Rcl: Close door relay
SG: Speed governor on top of the cabine Rop: Open door relay
SGW: Speed governor weight Rlt: Light relay

GOV: Governor in machine mechanical switch Com: If the board includes relay
Rdw: Door contact relay this output is connected to 0VAC
Cdn: Down direction contactor F-1, F-2, F-3: Fuses
Kcup: Auxiliary switch for up direction contactor should be N.C
Kcdn: Auxiliary switch for down direction contactor should be N.C
Cup: Up direction contactor

A A

page description: project: date:


September 14, 2012
ITAL GEARS OUTPUTS- AC 2 SPEED CEDRO CONTROLLER page:
8 of 11

5 4 3 2 1
5 4 3 2 1

N L3 L2 L1 POWER CIRCUIT, AC 2 SPEED

B1
POWER TRANSFORMER
380VAC11 1 60VAC ~ + H1 (+60VDC) H1 (+60VDC)

F L3
F L2
F L1
F1/4A F1/4A

2 0VAC - 0VDC
220VAC 3
~
10VAC-->17VAC H2 H6 (+22VDC)
B2
4 0VAC D1

2
2
2
D
110VAC 5 ~ + H3 (+22VDC) D
S1 10VAC -->17VAC F2/4A Cup
C1 C2
Cdn
6 0VAC

1
1
1
~ - 3300uF 3300uF
7 0VDC
H4 (220VAC)
8 0VAC
9
H5 (110VAC)

2
2
2
0VAC 12 10 0VAC
T1
PMD

5
6

1
1
1
1
1

2
3
L1
S2 2
L2
3 7
L3 P1 Chi Clo
4 8
N P2

L1-PMD

L1 F3/2A
BRAKE
C L2 F4/2A C

L3 F5/2A

0VDC

Cdn Cup

S1: Main circuit breaker


S2: Thermo-magnetic circuit breaker in control panel
Chi Clo L1-PMD 0VDC
Cdn: Down direction contactor 0VAC
Chi: High speed contactor
H2 (17VAC --> 24VAC)

H3 (+22VDC --> +48VDC) (*)

Clo: Slow speed contactor


B
(+) (-) 17V~ B
Cup: Up direction contactor
2

Typical
MPR: Motor protection relay CEDRO CONTROLLER
1

MPR
PMD: Phase balance and phase sequence monitoring device
U1 V1 W1
PTC: connected to the PTC input in the EMW2.15 board U2 V2 W2
1 4 (*): Optional feature
1 M 4
2 5
FL1, FL2, FL3, F1, F2, F3, F4 & F5: Fuses 2 3~ 5
3 6
3 6
7

Cdn: Down direction contactor


7

Cup: Up direction contactor MOTOR 3P


Chi: High speed contactor
PTC
Clo: Slow speed contactor
CEDRO CONTROLLER

A A

page description: date:


project:
June 14, 2012

ITAL GEARS POWER CIRCUIT, AC 2 SPEED CEDRO CONTROLLER page:


9 of 11

5 4 3 2 1
5 4 3 2 1

INPUTS- AC 2 SPEED
Magnetic Setup

D D

Rdw: door contact relay


OL: overload switch
ROP: push button to reopen automatic door
PC: photocell limit switch
DJ: door jam switch
FCL: push button close door immediately
EO: limit switch end of opening
EC: limit switch end of closing
PTC: input PTC from th motor 3 P
SUP: service up switch
SDN: service down switch
SEN: service enable switch
K1CUP: auxiliary switch for up direction contactor
K1cdn: auxiliary switch for down direction contactor
K2CUP: auxiliary switch for up direction contactor
K2Cdn:auxiliary switch for down direction contactor
C CE: car emergency push button C

CS: car step switch


FIRE:fireman switch
LSUP limit switch up
LSDN: limit switch down

(+22VDC)
H6
AUTOMATIC DOOR
(+22VDC)
H6
(+22VDC) (+22VDC)
2

OL (+22VDC) (+22VDC)
H6 H6
1

H3 H3
2

MONOSTABLE MAGNETIC SWITCH BISTABLE MAGNETIC SWITCH


SWINGING DOOR

DJ
1

B B
K1Cdn
1

2
CS
2
2

PTC

N.C.

N.C.
OL

1
2

PC
1

SW57
K2Cup

K2Cdn
SUP1

SDN 1

2
FIRE
SEN
1

2
2

2
FCL K1Cup
1

Rdw
2

1
SW PUSHBUTTON
EO EC

1
ROP
1

1
CE
2

2
STOP-FORCE CLSE

CLSE CIRC PTC SEN XOF XON STOP STOP-FIRE UP DN LSUP LSDN UP DN LSUP LSDN
CLSE CIRC

DOR EO

DOR EC

F1-SUP

F0-SDN

SpIn 1

SpIn 2
STOP - LZ
CEDRO CONTROLLER

A A

page description: project: date:


September 14, 2012
ITAL GEARS INPUTS- AC 2 SPEED CEDRO CONTROLLER
page: 10 of 11

5 4 3 2 1
5 4 3 2 1

(+22VDC)
H6
OUTSIDE CALLS

29

28

30 STOPS, VVVF 3 -SPEED AUTOMATIC / SWINGING DOOR 27

26
D D

25
PANEL BOARD DIAGRAM 24

SERIAL CONNECTION 23

22

21

20

19

18

17

16

15

14

13

12

11

10
C C
GO TOP2 GO ROOM2 GO PIT2 OT_DN6 OT_UP6
SAFETY1= S1
ROPE STOP2 STP INSP2 STOP IN PIT2 9
1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

8
DO6
Q12 7
6
Q2=22VDC
5
FAULT RELAY 4
For Auto Door For Manual Door
3
VVVF DRIVE
S1 S1 S1 2
1 2
(+22VDC)
MIDDLE SLOW HIGH VFF INSPECTION/ Ramp Ramp
0VDC Q2 1
SPEED SPEED SPEED 24V BREAK UP DN
0
S1 S1 INDICATOR (+22VDC)
Rop Rcl M1 0VDC Q2
GRAY OR BINARY CODE
*INS *INS Rlt * Rcm
A1

A1

A1

A1

A1

A1

* * *
~ ~ ~ ~ ~ ~
A2

A2

A2

A2

A2

A2

SLOW DOWN SPARE1 COM1 SPARE2 UP DNW VVVF LIGHT OPEN CLOSE CLOSE COM2 E D C BA (-) (+) 14D 13D 12D 11D 10D 9D 8D 7D 6D 5D 4D 3D 2D 1D 0D 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F 0F
ARO UP

ARO DN
B B

A
TO CABIN BOARD
HAPPY BOARD CONTROLLER B

DROP
OUT STP XOFF XON PTC B1 A1 17V~
N.C.

(17VAC)
K2Cdn
1

CE

0VAC
2

K1Cdn

K1Cup
1

DUPLEX
2

2
K2Cup
1
1

CS PTC
2
2

A A

Q22
(+22VDC)

page description: project: date:


September 14, 2012

ITAL GEARS 30 STOPS, VVVF 3 -SPEED AUTOMATIC/SWINGING DOOR CEDRO CONTROLLER page:
11 OF 11

5 4 3 2 1