Cat C13
®
DIESEL GENERATOR SETS
Standby & Prime: 50Hz
Engine Model Cat® C13 ACERT™ In-line 6, 4-cycle diesel
Bore x Stroke 130mm x 157mm (5.1in x 6.2in)
Displacement 12.5 L (763 in³)
Compression Ratio 16.3:1
Aspiration Turbocharged Air-to-Air Aftercooled
Fuel Injection System MEUI
Governor Electronic ADEM™ A4 - G2 Class* capable
Image shown might not reflect actual configuration
Model Standby Prime Emission Strategy
DE400E0 400 kVA, 320 ekW 350 kVA, 280 ekW Non-Certified Emissions
PACKAGE PERFORMANCE
Performance Standby Prime
Frequency 50 Hz
Genset Power Rating 400 kVA 350 kVA
Genset power rating with fan @ 0.8 PF 320 ekW 280 ekW
Emissions Non-Certified Emissions
Performance Number EM0425 EM0431
Fuel Consumption
100% load with fan, L/hr (gal/hr) 81.6 (21.5) 70.8 (18.7)
75% load with fan, L/hr (gal/hr) 60.6 (16) 53.5 (14.1)
50% load with fan, L/hr (gal/hr) 42.7 (11.2) 38.2 (10.1)
25% load with fan, L/hr (gal/hr) 25.6 (6.7) 23.2 (6.1)
Cooling System 1
Radiator air flow restriction (system), kPa (in. Water) 0.12 (0.48) 0.12 (0.48)
Radiator air flow, m3/min (cfm) 398 (14055) 398 (14055)
Engine coolant capacity, L (gal) 13.9 (3.7) 13.9 (3.7)
Radiator coolant capacity, L (gal) 43 (11.5) 43 (11.5)
Total coolant capacity, L (gal) 56.9 (15.2) 56.9 (15.2)
Inlet Air
Combustion air inlet flow rate, m³/min (cfm) 22.4 (790) 20.3 (717.5)
Max. Allowable Combustion Air Inlet Temp, °C (°F) 44 (110) 44 (110)
Exhaust System
Exhaust stack gas temperature, °C (°F) 529.2 (985) 504.3 (939.7)
Exhaust gas flow rate, m³/min (cfm) 62.8 (2216) 54.8 (1936.6)
Exhaust system backpressure (maximum allowable) kPa (in. water) 10.0 (40.0) 10.0 (40.0)
Heat Rejection
Heat rejection to jacket water, kW (BTU/min) 128 (7271) 113 (6453)
Heat rejection to exhaust (total) kW (BTU/min) 290 (16484) 249 (14146)
Heat rejection to aftercooler, kW (BTU/min) 54 (3037) 43 (2425)
Heat rejection to atmosphere from engine, kW (BTU/min) 53 (3031) 47 (2694)
LEHE1631-03 1/2
Cat C13
®
DIESEL GENERATOR SETS
Emissions2 (Nominal-CORR 5%) Standby Prime
NOx, mg/Nm³ (g/hp-hr) 2731 (5.3) 2874.9 (5.6)
CO, mg/Nm³ (g/hp-hr) 750 (1.47) 761.4 (1.5)
HC, mg/Nm³ (g/hp-hr) 8 (0.02) 7.2 (0.02)
Alternator 3
Voltages 415V 400V 380V
Motor starting capability @ 30% Voltage Dip 1071 skVA 793 skVA 888 skVA
Current 556 amps 577 amps 381 amps
Frame Size A2925L4 A2925L4 A2925L4
Excitation SE SE SE
Temperature Rise 125°C 125°C 125°C
WEIGHTS & DIMENSIONS
A B
Note: General configuration not to be used for installation. See general dimension drawings for detail.
Dim “A” mm (in) Dim “B” mm (in) Dim “C” mm (in) Dry Weight kg (lb)
3830 (151) 1130 (44) 2156 (85) 3253 (7172)
APPLICABLE CODES AND STANDARDS: DEFINITIONS AND CONDITIONS
AS1359, IEC60034-1, ISO3046, ISO8528, NEMA MG1-33, EAC,CE,UKCA. 1
For ambient and altitude capabilities consult your Cat dealer. Air flow restriction
Note: Codes may not be available in all model configurations. Please consult your (system) is added to existing restriction from factory.
local Cat Dealer representative for availability. 2
Emissions data measurement procedures are consistent with those described
STANDBY: Output available with varying load for the duration of the in EPA CFR 40 Part 89, Subpart D & E and ISO8178-1 for measuring HC, CO, PM,
interruption of the normal source power. Average power output is 70% of the NOx. Data shown is based on steady state operating conditions of 77° F, 28.42
standby power rating. Typical operation is 200 hours per year, with maximum in HG and number 2 diesel fuel with 35° API and LHV of 18,390 BTU/lb. The
expected usage of 500 hours per year. nominal emissions data shown is subject to instrumentation, measurement,
facility and engine to engine variations. Emissions data is based on 100% load
PRIME: Output available with varying load for an unlimited time. Average power
and thus cannot be used to compare to EPA regulations which use values based
output is 70% of the prime power rating. Typical peak demand is 100% of prime
on a weighted cycle.
rated ekW with 10% overload capability for emergency use for a maximum of 1
hour in 12. Overload operation cannot exceed 25 hours per year.
3
Generator temperature rise is based on a 40° C ambient per IEC60034-1.
* Governing Class capability as per [Link] your local Cat dealer for
RATINGS: Ratings are based on SAE J1349 standard conditions. These ratings configuration and site specific transient performance classification.
also apply at ISO3046 standard conditions.
[Link]/electricpower
©2024 Caterpillar. All rights reserved.
Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication.
CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge” and Cat “Modern Hex”
LEHE1631-03 (08/24) trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
2/2