Servidor Foxboro V91
Servidor Foxboro V91
PSS 41H-4V91
Product Specification
November 2022
https://www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished
for informational use only. No part of this guide may be reproduced or transmitted in
any form or by any means (electronic, mechanical, photocopying, recording, or
otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as is"
basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
Overview V91 Virtualization Server
Overview
Virtualization is a technology that allows consolidation of multiple servers into a single
physical server. This consolidation into a 2U rack-mounted package consumes fewer
plant resources. The package is easier to install and maintain. It delivers the
technological foundation for high available topologies enabling live migration from
running VMs from one physical server instance to a redundant partner and centralized
management (CVM) of two or more virtualization servers. The V91 Foxboro DCS
Virtualization Server can host up to fourteen Virtual Machines (VM).
The Model V91 Foxboro DCS virtualization server host is a 2U rack-mount server
running the Microsoft Windows Server® 2016 operating system. In addition, a virtual
machine running the Microsoft Windows Server 2016 operating system can be used
as a Domain Controller for the V91 Model host servers. Through the use of Microsoft
Hyper-V virtualization technology, the V91 is capable of hosting virtual machines
running Microsoft Windows Server 2016 operating system.
The virtual machines that are supported include:
• Foxboro DCS virtual machines with Control Core Services v9.4 or later and
Control Software v7.1 or later on the Foxboro DCS Control Network
• Virtual machines using the Schneider Electric-provided virtual machine operating
system image on networks other than the Control Network
The V91 Server is available with a user-configurable model code.
NOTE: The cover image represents a fully configured server and might show
configuration options (for example, hard disks or PCI cards) that are not part of an
actual product order.
Features
The Model V91 Host Server running Server 2016 allows for the following features:
• Replication - Replica VMs are automatically created and synchronized to a
replica V91 host
• Live Migration - Ability to move an active VM from one host to another with no
disruption to the operator
• Centralized Management - Ability to monitor and maintain one or more V91
Virtualization Servers from a remote location
• NIC Teaming - Provides redundancy at the Virtualization host for off control
networks
• VM Export without shutdown
NOTE: In order to take advantage of Replication, Live Migration, and
Centralized Management, a user-supplied network, referred to as the Virtual
Host Network, and a Server 2016 Active Directory domain are required. A
user-friendly application is provided to simplify the installation and
configuration of this domain.
Other Model V91 Server features include:
• A single or dual processor (each with eight cores), up to 384 GB of memory, up to
eight internal hard drives, redundant hot-swappable power supplies, and optional
Redundant Array of Independent Disks (RAID) configurations
• The ability to host up to 14 virtual machines running Microsoft Windows Server
2016. One of the virtual machines can be configured to run Microsoft Windows
Server 2016 operating system as a Domain Controller for V91 host servers.
• McAfee® Endpoint Security helps provide security on the V91 server
• Security by Local Group Policies to provide additional layer of protection
• Virtual machines on a V91 can:
◦ Be a control processor host and/or provide historization and Foxboro DCS
monitoring functions as a Schneider Electric station
◦ Serve as a Foxboro DCS workstation or Control Core Services application
platform and a human interface station (can open the VM directly)
◦ Function as Remote Desktop Services servers to support up to 30 Foxboro™
DCS FoxView per VM or up to 10 Foxboro™ DCS Control HMI remote clients
per VM with a limit of 60 RDP sessions across all VMs on a V91 server
◦ Support enterprise security Foxboro DCS software with optional McAfee
software package. McAfee Endpoint Security provides additional security
enhancement features to help complement the security features already built
into our products. For stations operating in Local Edition mode, McAfee
Endpoint Security (ENS) provides advanced Threat Prevention. For stations
operating in Enterprise Edition mode, McAfee ePolicy Orchestrator (ePO)
provides all the security of ENS plus Rogue System Detection, Application
Whitelisting, Integrity Control and Device Control for Data Loss Prevention
(DLP). The license entitlement for the first five years after purchase for all of
the listed options is included for the V91 server. After the five years, a renewal
is required with the purchase of the McAfee five year license (J0202AS) for
each V91 server using any McAfee products.
NOTE: McAfee Endpoint Security is included with Model V91, However, it is
not pre-installed/ configured on the system. For additional McAfee security
protection options, see PSS 41S-4MCAFEE.
NOTICE
POTENTIAL SYSTEM VULNERABILITIES
Install and configure EPP on all virtual machines (VMs) to help protect against
system vulnerabilities.
Failure to follow these instructions can result in system vulnerabilities.
The virtual machines hosted by the V91 server connect to the network through
internal virtual switches that map virtual machines to the V91’s physical 1Gb copper /
fiber Ethernet ports. The virtual switch network can be configured to map network
connectivity to:
• The Control Network
• The DCS Auxiliary Communications Network (ACN), a 1Gb network comprised of
managed Ethernet switches
• Other auxiliary networks
A combination of these different network types can be used.
The virtual machine’s network connectivity is configured independently from other
virtual machines hosted by the same V91 server. Each network utilizes a dedicated
physical 1Gb copper / fiber Ethernet port. The Control Network has two dedicated
1Gb Ethernet ports while the DCS Auxiliary Communications Network (ACN) has one
or more dedicated 1Gb Ethernet ports optionally configured to use NIC teaming.
With the exception of the Ethernet network ports, virtual machines cannot access the
V91 physical ports (serial, USB, etc.) Therefore, virtual machines only support
peripherals that are connected through the network, such as thin clients and network
printers. Remote graphics units, GPS time synch cards, and local printers are not
supported on virtual machines. A virtual machine can access the USB annunciator
keyboard through a thin client.
Sizing
• A V91 server can support up to fourteen virtual machines.
• The maximum number of RDP sessions depends on the number and types of
applications being run in the remote sessions. This includes the number of
process control points being updated, number of alarms being delivered, number
of displays open, etc. If your application needs are high, you might find the actual
number of client sessions to be lower. Experimental results indicate that for
planning purposes, the number of RDP sessions per virtual machine cannot
exceed 30 RDP sessions for FoxView VMs and 10 RDP sessions for Control HMI
VMs.
• The total number of RDP sessions across all VMs on a V91 server cannot exceed
60.
Licensing
There are no Foxboro DCS licenses associated with the V91 server itself. However,
each virtual machine must have the proper Foxboro DCS license. Virtual machine
Foxboro DCS licenses are identical to physical machine licenses.
V91 Options
The Model V91 server offers these options:
• Expandable virtualization hosting support for up to fourteen Virtual Machines
running Microsoft Windows Server 2016 operating system, 64 bit package
• McAfee ENS licenses for the host and up to fourteen Virtual Machines
• Dual Intel Xeon CPU processor
• Up to 384 GB registered memory
• No disk unavailability protection - One 600 GB SAS hard drive for operating
system “C” drive and one 600 GB SAS hard drives in RAID 0 for “D” drive
• Disk unavailability protection - Two 600 GB SAS hard drives in RAID 1 for
operating system “C” drive and three 600 GB SAS hard drives in RAID 5 “D” drive
or three, four, five or six 1.2 TB SAS hard drives in RAID 5 with a hot spare for “D”
drive
• Options provide up to 4.8 TB total available disk space for virtual machines
• Single or dual port fiber NICs
• Single or dual port copper NICs
Mounting Options
The V91 is a 2U high, rack mount server which offers:
• Rail mounting kit as standard equipment
• Optional 2U cable management arm for easy rail mounting kit
The V91 can be placed in commercially available enclosures that have provisions for
adequate ventilation and cooling to maintain the ambient temperature inside the
enclosure does not exceed 95°F (35°C). If the enclosure ambient temperature is
higher than 95°F (35°C), additional fans are needed. See the Cooling section under
Functional Specifications, page 10
NOTE: Enclosures must accommodate a depth of at least 39.4 in (1000 mm) to
allow space for air flow at the front and back of the unit plus cables at the back of
the unit. Because of their depth, the V91 cannot be mounted in the standard single
depth rack enclosures.
With dual monitor PCIe video cards, the V91s can be located up to 4.5 m (15 ft) from
the monitor using direct connect and other human interface cables available from
Schneider Electric.
As indicated by the CE logo, the V91 conforms to the applicable European Union
Directives.
Functional Specifications
Processor Type Intel Xeon
Memory 16 GB DDR4 Registered Memory
Devices Served SAS Peripherals
• One 600 GB internal system disk drive (with option for a second one in a RAID1
configuration) for boot operating system, with one 600 GB disk drive with an option
for up to six 1.2 TB drives as an option in a RAID 5 configuration for use with the
virtual machines.
Controller Peripherals
• One SATA CD-RW/DVD drive
Video Displays (Up to 2)
• 23-inch LCD USB Touchscreen Monitor
• 23-inch LCD Monitor
Interfaces to External Devices (USB)
• Mouse or Optional Trackball
• Alphanumeric Keyboard
• Up to four optional touchscreen monitors
• Audio Speakers
Internal Diagnostics Self-checking performed at power-up
Video Output Type
• Quad mini-DP 1.4 port PCIe graphics card with adapters to standard display port, up
to 4 x1920x1080 (Full HD) pixel resolution
Screen Presentation
• Refresh Rate
◦ Up to 85 Hz
• Colors
◦ 32 bit
• Resolution
◦ Widescreen (16:9) (Supported by 23-Inch LCD Monitor)
◦ Up to 1920x1080 pixels
Ethernet Interface PCIe Ethernet network interface cards providing connection to Ethernet data bus (10/
Communications 100Base-TX or 100Base-FX)
Four Integrated Ethernet ports (10/100/1000Base-T)
Power Supplies Two redundant, hot swappable, 800 W auto-switching input power supplies, each with a
separate power cord
Power Requirements
Power Parameters
Input Power
• 100-240 VAC, 50 to 60 Hz, auto ranging
Inrush Current
• 30 A power supply for 20 ms
Heat Dissipation
• 3067 BTU/hr (at 100 VAC)
• 2958 BTU/hr (at 200 VAC)
Power Consumption When equipped with two CPUs with 16 cores (100% utilized) and eight hard drives the
(Typical) measured typical power consumption is 250 watts
Cooling Hot swappable, redundant I/O and processor fans. Each redundant power supply
contains a fan. Temperature Specification can be extended up to 40°C (104°F) with the
Optional High Temperature DL380 Gen10 High Performance Fan Kit, Schneider Electric
Part Number RH103ES. This fan kit does increase the fan noise of the machine.
Regulatory
• U.S. and Canada
Compliance,
Electromagnetic Complies with FCC Part 15, Class B
Compatibility (EMC) • EU
Complies with the EU EMC Directive 2004/108/EC and the following Harmonized
Standards:
◦ EN 55022:2010 CLASS A
◦ EN 55024:2010
◦ EN 61000-3-2:2006 +A1:2009 +A2:2009
◦ EN 61000-3-3:2008
• Other Regulations
Complies with EU Energy Use Regulation (EC) No. 617/2013
Regulatory
• U.S. and Canada
Compliance, Product
Safety UL® and cUL Listed
• EU
Complies with the Low Voltage Directive 2006/95/EC and the following Harmonized
Standards:
◦ EN 60950:2006 +A1:2010 +A11:2009 +A12:2011
◦ EN62479:2010
• International
Complies with IEC 60950:2005 +A1:2009
RoHS Compliance Complies with EU RoHS Directive 2011/65/EU under the following Harmonized Standard:
EN 50581:2012
Environmental Specifications
Operating Storage
Temperature 10° to 35°C (50° to 95°F) at sea level with an -30° to 60°C (-22° to 140°F)
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum Maximum rate of change is 20°C/hr (36°F/
of 3050 m (10,000 ft); no direct sustained hr)
sunlight.
Maximum rate of change is 10°C/hr (18°F/hr).
The upper limit might be limited by the type and
number of options installed.
10 to 40°C (50 to 104°F) with the Optional
RH103ES HP DL380 Gen10 High Performance
Fan
System performance might be reduced if
operating with a fan fault or above 30°C (86°F).
Relative 10% to 90% relative humidity (Rh), 28°C (82.4° 5% to 95% relative humidity (Rh), 38.7°C
Humidity F) maximum wet bulb temperature, (101.7°F) maximum wet bulb temperature,
noncondensing noncondensing
Maximum 0.26 G at 5 to 350 Hz in operational orientations 1.54 G rms at 10 Hz to 250 Hz in all
Vibration orientations
Shock Half sine shock in all operational orientations of Half sine shock on all six sides of 71 G
31 G +/-5% with a pulse duration of 2.6 ms +/-5% with a pulse duration of 2 ms
+/-10% +/-10%
Square wave shock on all six sides of 27
G with velocity change at 235 in/sec or
greater
Altitude 3050 m (10,000 ft). This value might be limited -16 to 9144 m (-50 ft to 30,000 ft)
by the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min)
Contamination Class G1 (Mild) as defined in ISA Standard S71.04
Location UL/UL-C listed as suitable for use in ordinary locations and meets ordinary safety standards
for fire and shock hazards.
Physical Specifications
Keyboard Chassis
Dimensions Height Maximum outside dimensions with bezel
and feet
• 35 mm (1.4 in)
Width Height
• 445 mm (17.5 in) • 87.3 mm (3.44 in) with bezel
Depth Width
• 150 mm (5.9 in) • 445 mm (17.5 in)
Depth
• 680 mm (26.75 in)
Weight 1.8 kg (4.0 lbs) Rack
• 23.6 kg (51.5 lbs) maximum
configuration
Ordering Information
Part Number Description
V91 Virtualization Server for Foxboro DCS Virtual Machines
K0204AT Media kit required to use Centralized Virtualization Management (CVM) with MS
Server 2016. One kit required per V91
RH103FL HP T740 Quad Video Thin Client Single NIC
RH103FN HP T740 Quad Video Thin Client Dual NIC
Related Documents
Document Number Description
B0700HQ Model V91 Server Virtualization Host (HP DL380 Gen10) for Windows Server 2016
User’s Guide
PSS 41S-8HYPRVOV Hypervisor Technology — Microsoft Hyper-V Hypervisor
B0700HC Centralized Virtualization Management User's Guide for Windows Server 2016
B0700HD Virtualization for Windows Server 2016 User’s Guide
B0700CA Switch Configurator Application Software (SCAS) for the Control Network User's
Guide
PSS 41H-4THNCLNT Thin Clients
B0700WC Thin Client for Windows 10 User’s Guide
B0700VN Thin Client User’s Guide
PSS 41S-4MCAFEE McAfee Security Products
B0700WK McAfee ENS 10.7 and ePO 5.10 Installation Guide
B0700HS Veritas System Recovery 18
PSS 41H-4THNCLNT
Product Specification
April 2023
https://www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished
for informational use only. No part of this guide may be reproduced or transmitted in
any form or by any means (electronic, mechanical, photocopying, recording, or
otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as is"
basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
Overview of Thin Clients Thin Client
Features
With a smaller footprint than a workstation, the t740 HP® thin clients are mounted local
to their remote user and used in traditional and virtualized Foxboro DCS systems.
Thin clients allow operators to perform similar tasks as a workstation and provide
ease of use and increased security as compared to physical stations.
The t740 thin clients can:
• Serve as human machine interface (HMI) stations with remote connections to
remote servers running Microsoft® Remote Desktop Services or SE RDP
Connection Manager
• Remotely, allow you to view and manage your Foxboro DCS software suite
• Communicate with Foxboro DCS servers through the Auxiliary Communications
Network (ACN) via a single or redundant NIC network connection
• Automatically shift between RDP servers if one has a detected failure
Configurations
Thin clients can be set up in one of these configurations:
• A specific thin client is restricted to connect to one particular virtual machine or
one physical Foxboro DCS server.
• A specific thin client is connected automatically to only one particular virtual
machine, or one physical Foxboro DCS server when the thin client boots up.
• A specific thin client has the option to connect to one of several different virtual
machines and/or physical Foxboro DCS servers for one at a time redundancy.
• A specific thin client has the option to connect to multiple virtual machines and/or
multiple physical Foxboro DCS servers simultaneously.
• A specific thin client is connected automatically to multiple virtual machines and/
or multiple physical Foxboro DCS servers when the thin client boots up.
• A specific thin client used within the Local Edition Control Core Services and Off-
Domain in the Enterprise Edition Control Core Services.
• Trellix ENS protection is installed as a self-managed solution.
Sizing
A single remote server running Microsoft Remote Desktop Services can support up to
30 FoxView simultaneous remote sessions and up to 10 Control HMI remote
sessions. Collectively, the V91 server virtualization host cannot support more than 60
Remote Desktop Protocol (RDP) sessions across the VMs due to bandwidth
constraints of the V91 physical Ethernet ports.
NOTE: The allowable number of RDP sessions depends on the number and types
of applications being run in the remote sessions.
Cybersecurity
Thin clients can be configured to restrict connections to certain remote servers. After a
thin client establishes a connection with a remote server, the remote server’s
configuration determines what privileges to grant the user based on the user profile
logged into the remote server.
As an option, Trellix Endpoint Security (part number K0204BM) can provide additional
security enhancement features to help complement the security features already built
into our products. Trellix Endpoint Security (ENS) helps provide the advanced Threat
Prevention feature. The license entitlement for the first five years after purchase is
included when purchased for the t740 thin client. After five years, a renewal is
required.
For details about Trellix Endpoint Security, see Trellix Endpoint Protection Installation
and User’s Guide (B0700WR).
Licensing
These types of licensing apply when using thin clients with a Foxboro DCS:
• Software Suite License for Foxboro DCS
• Microsoft licensing
Microsoft Licensing
• Microsoft Windows Server permits remote access for two users without CALs
solely for administrative and technical product support purposes. These sessions
are in addition to the local desktop session which can run in conjunction with
these RDP sessions.
• There are additional Microsoft licenses needed if a thin client is being used for
additional connections to Microsoft Remote Desktop Services servers (formally
known as Terminal Services sessions). These licenses are available in
BuyAutomation in five license packs for both a “license per user” or “license per
device” model.
• Foxboro part number J0202AW provides five Remote Desktop Services 2016
Device CALs. Foxboro part number J0202AV provides five Remote Desktop
Services 2016 User CALs.
◦ RDS CALs per DEVICE license: One RDS CAL per device is required for
each device which accesses a remote desktop session. Devices can be thin
clients, computers or portable devices. Once a device has accessed the
remote desktop server, the RDS CAL per device license will be consumed by
that device and no other device can use that license. That device will continue
to be able to connect to the remote desktop server with any user logging on.
◦ RDS CALs per USER license: One RDS CAL per user is required for each
user that accesses a remote desktop session. RDS CALs per user licenses
are tied to the users logged on to the remote desktop server, regardless of the
device they are connecting from.
◦ RDS CALS must be installed and activated on a license server (usually an
RDS server).
A Front
B USB 3.1 Gen 1
C USB 3.1 Gen 2
D Headphone or audio jack
E USB-C 3.1 Gen 2
F Rear
G DisplayPort 1.2
H RJ45 GbE connector
I Cable lock slot
J PCI Express Expansion Slot — choice of
• Discrete graphics card
• Fiber Optic NIC interface
K USB 3.1 Gen 1
L USB 2.0
Functional Specifications
Operating System Windows 10 IoT Enterprise LTSC 2019
Processor Type AMD® processor
Processor AMD Ryzen™ V1756B with Radeon™ Vega 8 Graphics (3.25 GHz base clock, up to 3.6
GHz max boost clock, 2 MB cache, 4 cores)
Memory 32 GB DDR4-3200 SDRAM
Transfer rates up to 3200 MT/s
Internal Storage 128 GB Flash memory
Devices Served Video Displays (Up to 4)
• 23-inch LCD USB Touchscreen Monitor (P0928JJ)
• 23-inch LCD Monitor (P0928JH)
• 24-inch LCD Monitor (RH103FR)
Interfaces to External Devices
• USB
◦ Mouse or optional trackball
◦ QWERTY keyboard
◦ Annunciator keyboard (up to 4) (P0924TT and P0924WV)
◦ External speakers
◦ External DVD drive, required for SeRdpConnectionManager DVD. The RDP
Connection Manager is included with the dual NIC version. It can be purchased
separately for the single NIC with part number K0177DQ.
Internal Diagnostics Self-checking is performed at power-up.
Video Output Type
• Four DisplayPort 1.2 video port
Screen Presentation
• Refresh Rate
◦ Up to 85 Hz
• Colors
◦ Over 65,000(a)
• Resolution
◦ Widescreen (16:9) Aspect Ratio
– Up to 1920 x 1080 pixels for CCS and CS displays
Network Ethernet One Integrated Ethernet port (10/100/1000Base-T)
Interface
Communications
Network Interface Card One onboard NIC card standard with the RH103FL Thin Client
One onboard NIC card and a second plugin 10/100/1000 CATS NIC card for the
redundancy standard with the RH103FN Thin Client
DCS Auxiliary TYPE
Communications • TCP-IP
Network Interface
Environmental Specifications
Operating(a) Temperature
• 10 to 40°C (50 to 104°F)
Relative Humidity
• 10% to 90%, noncondensing
• 20% to 80%, condensing
Altitude
• 300 m to 3 km (1000 to 10,000 ft)
Storage Temperature
• -30 to +60°C (-22 to +140°F)
Relative Humidity
• 10% to 90%, noncondensing
Altitude
• 300 m to 3 km (1000 to 10,000 ft)
Accessibility Section 508 Accessibility. VPAT report available
Environmental Worldwide (ENERGY STAR®, EPEAT 2.0, RoHS2, ERP, TCO, CECP& SEPA, HP
Stewardship GSE, WEEE, Low Halogen, etc.)
Product Safety Worldwide (UL, CB, GS, CCC, BSMI, etc.)
Electromagnetic Worldwide (FCC/CISPR/EN/VCCI/ICES/AS/NZS/CNS/KCC) “Class B” EMI regulations
Compliance (EMC)
(a) Specifications are at sea level with no direct, sustained sunlight. Upper limit might be limited by the type and
number of options installed.
Physical Specifications
Dimensions Vertical Orientation
• Height
◦ 210 mm 8.26 in)
• Width
◦ 50 mm (1.97 in)
• Depth
◦ 210 mm (8.26 in)
Mounting • Tabletop
• VESA 100
Weight 1323 g (2.92 lb)
Heat Dissipation(a) 90 W Power Supply
• @ 100 VAC (60 Hz)
◦ 57 BTU/hour, short idle
◦ 55 BTU/hour, long idle
◦ 5 BTU/hour, sleep
◦ 4 BTU/hour, off
• @ 115 VAC (60 Hz)
◦ 57 BTU/hour, short idle
◦ 55 BTU/hour, long idle
◦ 5 BTU/hour, sleep
◦ 5 BTU/hour, off
• @ 230 VAC (50 Hz)
◦ 57 BTU/hour, short idle
◦ 56 BTU/hour, long idle
◦ 5 BTU/hour, sleep
◦ 5 BTU/hour, off
(a) Heat dissipation is calculated based on the measured watts, assuming the service level is attained for one hour.
Related Documents
For more information regarding the thin client product offering, see these documents.
The latest revisions are available through at https://pasupport.schneider-electric.com.
Configuration Document
Supported Monitors Liquid Crystal Display (LCD) Monitors (PSS 41H-
4VDU)
V91 Server Virtualization Model M92 (P0928KK) Industrial Workstation with
Host Windows® 7 Professional Operating System (PSS
41H-4M92)
Model V91 Virtualization Host Server (HP DL380
Gen10) for Windows Server 2016 User’s Guide
(B0700HQ)
Virtualization Hypervisor Technology — Microsoft® Hyper-V™
Hypervisor (PSS 41S-8HYPRVOV)
Virtualization for Windows Server 2016 User’s
Guide (B0700HD)
Central Virtualization Centralized Virtualization Management for
Management Windows Server 2016 User’s Guide (B0700HC)
DCS Auxiliary Switch Configurator Application Software (SCAS)
Communications Network for the Control Network User's Guide (B0700CA)
(ACN) Configuration
Thin Client Hardware and Thin Client User's Guide (B0700VN)
Configuration
Thin Client with Windows 10 User’s Guide
(B0700WC)
Endpoint Protection Trellix Endpoint Protection Installation and User’s
Guide (B0700WR)
Trellix Endpoint Protection (PSS 41S-4Trellix)
Annunciator Keyboard USB-Based Annunciator Keyboard User's Guide
Support (B0700FT)
PSS 41H-4VDU
Product Specification
November 2022
https://www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished
for informational use only. No part of this guide may be reproduced or transmitted in
any form or by any means (electronic, mechanical, photocopying, recording, or
otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as is"
basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
Overview Liquid Crystal Display (LCD) Monitors
Overview
The EcoStruxure Foxboro DCS Process Automation System has advanced
visualization software to help support plant operators in safely and securely achieving
maximum production. Modem high definition liquid crystal display monitors are
provided in the high definition aspect ratio.
Foxboro DCS systems offer 24-inch LCD monitors.
24-inch, Tabletop
While the previously offered 19-inch and 20-inch monitors had a standard 4:3 aspect
ratio, the 24-inch monitor has a standard 16:9 aspect ratio to support widescreen
resolutions, although it can support images at the 4:3 aspect ratio as well.
Workstations require the Foxboro DCS FoxView/FoxDraw application, version 10.2.4
or later and 1920x1080 high definition capability to support the 16:9 aspect ratio of the
24-inch monitor. This application is available for workstations, which support Foxboro
DCS Control Core Services software v9.0 and later. It supports displays in both the
4:3 and 16:9 aspect ratio. The application includes a conversion utility to convert
displays previously configured for the 4:3 aspect ratio to the 16:9 aspect ratio
supported by the 24-inch monitor.
Because the 24-inch monitors also support 4:3 aspect ratio displays, workstations
without both 1920 x1080 resolution and FoxView/FoxDraw 10.2.4 or later required for
16:9 displays can still use the 24-inch monitor to replace the previously offered 19-
inch or 20-inch monitors with 4:3 displays. While the 24-inch flat panel monitors work
best in their 1920x1080 standard resolution and newer workstations have this
capability, many older workstations (as noted in Flat Panel Monitor Software Setup for
UNIX and Windows Workstations (B0193PL)) do not. As a result, 24-inch monitors on
workstations with 4:3 aspect ratio displays must have their associated graphics cards
set to the specific resolutions listed in B0193PL.
NOTE: A single workstation cannot support a mix of 24-inch and the previously
offered 19-inch or 20-inch monitors.
European Certification
As symbolized by the CE logo on these monitors, they are in compliance with the
applicable European Union directives.
Color Consistency
These monitors are sourced through a global supply chain that treats this category of
equipment as a commodity item. As such, minor color inconsistencies among
delivered monitors are to be expected. If the application requires color adjustments or
strict consistency of color presentation, contact Global Customer Support at https://
pasupport.schneider-electric.com (registration required) for assistance in selecting
monitors of the appropriate capability.
Functional Specifications
Display Characteristics Resolution (Pixels):
• Standard Resolution
1920 H x 1080 V (usually used at 60 Hz)
Viewable Size:
• 60.47 cm (23.8 in)
Recommended Operating Resolution:
• Standard Workstation Models(a) H90 or P90, H91 or P91, H92 or P92, P93
and P95:
1920x1080x60
Input Characteristics
NOTE: The recommended resolution is a function of the graphics card in the
system, the monitor that the system originally had and the preference of the
operator. Older systems do not have the capabilities to host modern
1920x1080 high definition resolutions.
Input Connectors:
• Analog:
15–pin VGA
• Digital:
DVI-D and DisplayPort
Sync Range:
• Horizontal (Analog/Digital):
31.5 KHz to 83 KHz
• Vertical:
50 Hz to 75 Hz
Brightness (Typical) 250 cd/m2
Power Requirements • Input Voltage:
Auto Select: 100 to 240 VAC
• Line Frequency:
50 and 60 Hz nominal
• Input Current:
0.90 - 0.50 A (with USB and Audio)
• Power:
15 W Typical
(a) Note that Foxboro DCS systems will only operate at 1280x1020 resolution.
Environmental Specifications
Operating Storage
Temperature 5 to 35°C (41 to 95°F) -10 to +60°C (14 to 140°F)
Humidity 20 to 80% (non condensing) 10 to 85% (non condensing)
Altitude 0 to 5000 m (0 to 16404 ft) 0 to 12192 m (0 to 40,000 ft)
Location UL/UL-C listed as suitable for use in ordinary locations and is designed to help meet ordinary
safety standards for fire and shock hazards.
Contamination Class G1 (Mild) as defined in ISA Standard S71.04
Physical Specifications
Weight • Display with Swivel Stand:
6.1 kg (13.4 lb)
• Display without Swivel Stand:
3.6 kg (7.9 lb)
Mounting Desktop: 100 x 100 mm VESA mounting capability
Swivel Stand Swivel Range
• Side to Side:
±170° from center
• Up to Down:
+35°, -5° from center
Viewing Range ±89° from center
Dimensions Display
• Width: 537.7 mm (21.2 in)
• Height: 319.1 mm (12.6 in)
• Depth: 45.6 mm (1.8 in)
Display with Swivel Stand
• Width: 537.7 mm (21.2 in)
• Height: 336.6 - 486.6 mm (13.3 - 19.2 in)
• Depth: 250 mm (9.8 in)
Dimensionals Nominal
Regulatory Compliance
Safety
• US, Canada
Certifications
UL® / cUL
• EU
Complies with the Low Voltage Directive 2006/95/EC and the following Harmonized
Standards:
◦ EN 60950-1:2006+A11:2009+A1:2010+A12:2011
EMC
• USA, Canada
Complies with FCC Part 15, Class B
• EU
Complies with the EU EMC Directive 2004/108/EC and the following Harmonized
Standards:
◦ EN 55022:2010 Class B
◦ EN 55024:2010
◦ EN 61000-3-2:2006+A1:2009+A2:2009
◦ EN 61000-3-3:2008
• Other Regulations
◦ Complies with EU ErP Directive 2009/125/EC and Harmonized Standard
EN62301:2005
◦ Complies with EU RoHS Directive 2011/65/EU
PSS 41H-7NWEQUIP
Product Specification
November 2023
https://www.se.com
Legal Information
The information provided in this document contains general descriptions, technical
characteristics and/or recommendations related to products/solutions.
This document is not intended as a substitute for a detailed study or operational and
site-specific development or schematic plan. It is not to be used for determining
suitability or reliability of the products/solutions for specific user applications. It is the
duty of any such user to perform or have any professional expert of its choice
(integrator, specifier or the like) perform the appropriate and comprehensive risk
analysis, evaluation and testing of the products/solutions with respect to the relevant
specific application or use thereof.
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this document are the property of Schneider Electric SE or
its subsidiaries. All other brands may be trademarks of their respective owner.
This document and its content are protected under applicable copyright laws and
provided for informative use only. No part of this document may be reproduced or
transmitted in any form or by any means (electronic, mechanical, photocopying,
recording, or otherwise), for any purpose, without the prior written permission of
Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the
document or its content, except for a non-exclusive and personal license to consult it
on an "as is" basis.
Schneider Electric reserves the right to make changes or updates with respect to or in
the content of this document or the format thereof, at any time without notice.
To the extent permitted by applicable law, no responsibility or liability is
assumed by Schneider Electric and its subsidiaries for any errors or omissions
in the informational content of this document, as well as any non-intended use
or misuse of the content thereof.
Overview The Foxboro DCS Control Network Ethernet Equipment
Overview
The EcoStruxure Foxboro DCS Control Network uses Foxboro qualified Ethernet
equipment allowing you to configure your system to meet your functional,
performance, and plant requirements. With our switches, you can interconnect system
components (controllers, workstations, servers) effectively to help minimize the
quantities and lengths of interconnectivity cabling.
The Foxboro DCS Control Network equipment described in this document has been
tested and qualified for use with the Foxboro DCS. The qualified Ethernet switches
offered are listed in the table in Qualified Ethernet Switches, page 6.
Features
• System scalability by interconnecting Ethernet switches, each having eight ports
or more in various increments.
• Modular uplinks to high-speed backbones using:
◦ 1000Base-T
◦ 1000Base-SX
◦ 1000Base-LX
◦ 1000Base-LX/LH
◦ 1000Base-BX
◦ 1000Base-TX
◦ 1000Base-ZX standards
◦ 10GbBase-LR
◦ 10GbBase-LRM
◦ 10GbBase-SR
◦ 10GbBase-ZR
• System Management software for monitoring the health of the control system and
managing the equipment within the system.
• Compatible with the optional Network Monitoring software. For more information,
see ExtremeCloud IQ (XIQ) - Site Engine (PSS 41S-2XIQ-SE).
• Configure tasks through a local console port Command Line Interface (CLI) and
monitor through any SNMP/RMON based management application.
• Ethernet switches are European Union (EU) Low Voltage and EMC directives
safety certified “CE” logo marked on the product.
The X440-G2 10 Gigabit model switches require a license to upgrade the SFP+ 1
GbE ports to 10 GbE:
• (J0202DN) Dual 10 GbE upgrade license enables 10 GbE on the non-stack
capable ports.
• (J0202DP) Quad 10 GbE upgrade license enables 10 GbE on all four uplink
Ports.
Edge: 5420-Series
Switch Reference
24-Gigabit 4 SFP Managed Switch RH102BN, page 21
24-Gigabit 10/100/1000Base-Tx Managed Switch RH102BM, page 21
150 W AC Power Supply (redundant power only) RH102BP, page 22
Switch Reference
Auto-Ranging Power Supply RH102BJ, page 24 (for
RH102BF/BG/BH)
Redundant Power Supply RH102BJ, page 25 (for
RH102BF/BG/BH)
Switch Reference
Fast Ethernet Media Module GRM20, page 26
Industrial Managed Fast, Gigabit Managed Switch GRS-1030 16T9, page
27
Industrial Managed Fast, Gigabit Managed Switch GRS-1030 8T8Z, page
27
X-Series X460-G2
Switch Reference
24-Gigabit (SFP) Managed Switch RH102AB, page 29
300 W AC Power Supply (X460) RH102AE, page 32
Switch Reference
48-Gigabit (SFP) Managed Switch RH102AC, page 35
Fan Module RH102AF, page 39
X-Series: X440-G2
Switch Reference
12-Port Copper/8-Port Fiber X440-G2 Managed Switch RH102AP, page 40
12-Port Copper X440-G2 Managed Switch RH102AQ, page 43
24-Gigabit (SFP) Managed Switch RH102AD, page 46
24-Port Copper X440-G2 Managed Switch RH102AM, page 49
RH102AY, page 52
24-Port Fiber X440-G2 Managed Switch RH102AN, page 55
Switch Reference
Redundant Power Supply Chassis RH102AV, page 59
Redundant Power Supply (RPS) RH102AW, page 60
Redundant Power Supply (RPS), Rev. B RH102AX, page 61
GBICs: Non-Industrial
Switch Reference
2 km (1.24 mi) MGBIC module LC (LX/LH) 1300 N-m 1000Base-LX P0972YQ
275 m (902 ft) MGBIC module LC (SX) 850 N-m 1000Base-SX RH102AG
10 km (6.2 mi) MGBIC module LC (LX) 1310 N-m 1000Base-LX, SMF RH102AH
80 km (49.7 mi) MGBIC module LC (ZX) 1550 N-m 1000Base-ZX RH102AJ
100 m (330 ft) RJ-45 MGBIC Uplink module (TX) 10/100/1000Base-T RH102AL
100Base-FX 2 km (1.24 mi) MGBIC device module LC (1310 N-m) RH102BK
10 Gb SR SFP+ module 300 m (984 ft) MMF 850 N-m RH102BQ
10 Gb LR SFP+ module 10 km (6.2 mi) SMF RH102BR
10 Gb LRM SFP+ module 220 m (721 ft) MMF, 300 m (984 ft) SMF RH102BS
10 Gb ZR SFP+ module 80 km (49.7 mi) SMF RH102BT
Bi-directional Uplink 10K MGBIC module LC LX (1310 N-m) P0973JB
Bi-directional Downlink 10K MGBIC module LC LX (1490 N-m) P0973JC
Bi-directional MGBIC Kit containing both downlink and uplink 10K MGBIC P0973JD
Bi-directional Uplink 40K MGBIC module BX (1310 N-m) P0973KM
Switch Reference
Bi-directional Downlink 40K MGBIC module BX (1490 N-m) P0973KN
Bi-directional MGBIC Kit containing both downlink and uplink 40K MGBIC P0973KP
Bi-directional Uplink 120K MGBIC module BX (1490 N-m) P0973KQ
Bi-directional Downlink 120K MGBIC module BX (1590 N-m) P0973KR
Bi-directional MGBIC Kit containing both downlink and uplink 120K MGBIC P0973KS
X-Series X440-G2
RH102AP 12-Port Copper/8-Port Fiber X440-G2 Managed
Switch
RH102AP (X440-G2 managed switch) provides 12 Tri-speed 10/100/1000Base-T
ports with RJ-45 connectors, eight (8) 100Base-FX ports with LC connectors, and four
(4) (SFP) ports. The four SFP ports can be populated with 1000Base-X or 100/
1000Base-TX (RH102AL) MGBIC connector modules.
The switch allows high performance, managed layer-2 Ethernet switching in small- to-
medium-sized network applications, as well as high performance direct end-station
connectivity.
Features
The 12-Port Copper/8-Port Fiber X440-G2 managed switch features:
• 8 ports of 100Base-FX.
• 12 ports of Tri-speed 10/100/1000Base-T.
• Four 1000Base-X uplink Gigabit (SFP) ports.
• RJ-45 Category 5 connectors on switch copper ports.
• LC connectors on switch fiber ports.
• Full-duplex operation.
• Configuration tasks through a local console port and monitoring through any
SNMP/RMON based management application.
• Port mirroring technology and diagnostics that allow local network traffic to be
redirected to an external probe for detailed analysis.
• Compliance with industry standards, including IEEE 802.3u Fast Ethernet and
802.1w Rapid Spanning Tree Protocol (RSTP).
• Optional external redundant power supply.
• Shelf, desk, or 19-inch rack mounting.
All X440-G2 switches ship with fixed fans and power supplies.
CPU/Memory
• 64-bit MIPS Processor, 1 GHz clock, single core
• 1 GB ECC DDR3 DRAM
• 4 GB eMMC Flash
• 1.5 MB packet buffer
Uplink/Switch Interfaces
The Mini-GBIC SFP Connector Modules for Each Switch Type table, page 64 lists the
MGBIC modules that can be added to the X440-G2, 12 copper and eight (8) fiber Port
Managed Switch (RH102AP) switch. The MGBIC modules are added to specific SFP
ports to provide connectivity for ISL ports.
Power Supply
The RH102AP switch power is provided by an internal power supply that requires
separately fused 15-amp power circuits within 182 cm (6 ft) of the power supply.
Installation Guidelines
NOTICE
POTENTIAL EQUIPMENT DAMAGE
These guidelines must be observed when an installation location is selected for this
switch. If the guidelines are not followed, unsatisfactory network performance can
result.
• To provide for proper ventilation and help prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the top, bottom, left, right, and rear of the
switch. Do not connect the switch to the AC power source until instructed to do
so later in the installation process.
• During operation, ambient temperature at the installation site must be
maintained between 0° and 60°C (32° to 140°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
• Refer to installation document for details.
Failure to follow these instructions can result in equipment damage.
Functional Specifications
Ethernet Standards Supported • IEEE 802.1q VLAN support
• IEEE 802.1d MAC Bridging (including STP) IEEE 802.1p
• Quality of Service (QoS, Priority) IEEE 802.1w Rapid Spanning Tree
(RSTP) IEEE 802.3 including:
◦ Fast Ethernet: IEEE 802.3u, 100Base-T (Copper)
◦ Gigabit Ethernet: IEEE 802.3z, 1000Base-X (Fiber)
◦ Gigabit Ethernet: IEEE 802.3ab, 1000Base-T (Copper)
Power • Internal:
AC Input power (auto-sensing)
100 VAC to 240 VAC, 50 to 60 Hz +/- 5%
• External:
Supports connection for redundant power supply
• Heat Dissipation:
159 Btu/Hr
• Power Consumption:
32 Watts
• Maximum Power Consumption:
47 Watts
Environmental Specifications
Operating Storage
Temperature 0° to 60°C (32° to 140°F) -40° to +70°C (-40° to +158°F)
Relative Humidity 10 to 95% (non-condensing) 10 to 95% (non-condensing).
Altitude 0 to 3,000 meters (9,850 feet)
Physical Specifications
Mounting Desk or Enclosure: 48.3 cm (19 in) equipment rack, 1U high
Dimensions (Nominal) • Height: 4.4 cm (1.7 in)
• Width: 30.5 cm (12.01 in)
• Depth: 26.1 cm (10.28 in)
Weight (Approximate) 2.95 kg (6.5 lb)
Cable Connectors • Uplink Ports: RJ-45 copper or LC fiber
Vibration • Vibration: IEC 60068-2-64, IEC 60068-2-6
• Shock: IEC 60068-2-27
• Drop: ETSI/EN 300 019 2-2
Features
The 12-Port Copper X440-G2 managed switch features are:
• 12 ports of Tri-speed 10/100/1000Base-T.
• Four 1000Base-X uplink Gigabit (SFP) ports configurable as 1G/10G uplink ports.
The SFP+ ports can accommodate 1G/10GBASE-X GBICs only.
• RJ-45 Category 5 connectors on switch copper ports.
• Full-duplex operation.
• Configuration tasks through a local console port and monitoring through any
SNMP/RMON based management application.
• Port mirroring technology and diagnostics that allow local network traffic to be
redirected to an external probe for detailed analysis.
• Compliance with industry standards, including IEEE 802.3.ae 10 GbE, IEEE
802.3u Fast Ethernet and 802.1w Rapid Spanning Tree Protocol (RSTP).
• Optional external (power brick style) redundant power supply.
• Shelf, desk, or 19-inch rack mounting.
All X440-G2 switches ship with fixed fans and power supplies.
CPU/Memory
• 64-bit MIPS Processor, 1 GHz clock, single core
• 1 GB ECC DDR3 DRAM
• 4 GB eMMC Flash
• 1.5 MB packet buffer
Uplink/Switch Interfaces
The Mini-GBIC SFP Connector Modules for Each Switch Type table, page 64 lists the
MGBIC modules that can be added to the X440-G2, 12 copper Port Managed Switch
(RH102AQ) switch. The MGBIC modules are added to specific SFP ports to provide
connectivity for ISL ports.
Power Supply
The RH102AQ switch power is provided by an internal power supply that requires
separately fused 15-amp power circuits within 182 cm (6 ft) of the power supply.
Installation Guidelines
NOTICE
POTENTIAL EQUIPMENT DAMAGE
These guidelines must be observed when an installation location is selected for this
switch. If the guidelines are not followed, unsatisfactory network performance can
result.
• To provide for proper ventilation and help prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the top, bottom, left, right, and rear of the
switch. Do not connect the switch to the AC power source until instructed to do
so later in the installation process.
• During operation, ambient temperature at the installation site must be
maintained between 0° and 50°C (32° to 122°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
• Refer to installation document for details.
Failure to follow these instructions can result in equipment damage.
Functional Specifications
Ethernet Standards Supported • IEEE 802.1q VLAN support
• IEEE 802.1d MAC Bridging (including STP) IEEE 802.1p
• Quality of Service (QoS, Priority) IEEE 802.1w Rapid Spanning Tree
(RSTP) IEEE 802.3 including:
◦ Fast Ethernet: IEEE 802.3u, 100Base-T (Copper)
◦ Gigabit Ethernet: IEEE 802.3z, 1000Base-X (Fiber)
◦ Gigabit Ethernet: IEEE 802.3ab, 1000Base-T (Copper)
Power • Internal:
AC Input power (auto-sensing)
100 VAC to 240 VAC, 50 to 60 Hz +/- 5%
• External:
Supports connection for redundant power supply
• Heat Dissipation:
109 Btu/Hr
• Power Consumption:
15 Watts
• Maximum Power Consumption:
32 Watts
Environmental Specifications
Operating Storage
Temperature 0° to 50°C (32° to 122°F) -40° to +70°C (-40° to +158°F)
Relative Humidity 10 to 95% (non-condensing) 10 to 95% (non-condensing).
Altitude 0 to 3,000 meters (9,850 feet)
Physical Specifications
Mounting Desk or Enclosure: 48.3 cm (19 in) equipment rack, 1U high
Dimensions (Nominal) • Height: 4.4 cm (1.7 in)
• Width: 30.5 cm (12.01 in)
• Depth: 26.1 cm (10.28 in)
Weight (Approximate) 2.64 kg (5.82 lb)
Cable Connectors • Uplink Ports: RJ-45 copper or LC fiber
Vibration • Vibration: IEC 60068-2-64, IEC 60068-2-6
• Shock: IEC 60068-2-27
• Drop: ETSI/EN 300 019 2-2
Features
The 24-Gigabit (SFP) X440-G2 managed switch features:
• 24-port 1000Base-X 1 Gb SFP ports (the SFP ports can be configured as
100Base-FX or 100Base-Tx with the appropriate GBIC transceiver).
• Four (4) combo ports (SFP or Copper RJ-45) ports configurable as 1G/10G uplink
ports, SFP+ ports accommodate 1G/10GBase-X GBICs only.
• Full-duplex operation.
• Configuration tasks through a local console port and monitoring through any
SNMP/RMON based management application.
• Port mirroring technology and diagnostics that allow local network traffic to be
redirected to an external probe for detailed analysis.
• Compliance with industry standards, including IEEE 802.3.ae 10 GbE, IEEE
802.3u Fast Ethernet and 802.1w Rapid Spanning Tree Protocol (RSTP).
• Optional external redundant power supply.
• Shelf, desk, or 19-inch rack mounting.
All X440-G2 switches ship with fixed fans and power supplies.
CPU/Memory
• 64-bit MIPS Processor, 1 GHz clock, single core
• 1 GB ECC DDR3 DRAM
• 4 GB eMMC Flash
• 1.5 MB packet buffer
Uplink/Switch Interfaces
The Mini-GBIC SFP Connector Modules for Each Switch Type table, page 64 lists the
MGBIC modules that can be added to the X440-G2 24 port (SFP) Port Managed
Switch (RH102AD) switch. The MGBIC modules are added to specific SFP ports to
provide connectivity for ISL or device ports.
Power Supply
The RH102AD switch power is provided by an internal power supply that requires
separately fused 15-amp power circuits within 182 cm (6 ft) of the power supply.
Installation Guidelines
NOTICE
POTENTIAL EQUIPMENT DAMAGE
These guidelines must be observed when an installation location is selected for this
switch. If the guidelines are not followed, unsatisfactory network performance can
result.
• To provide for proper ventilation and help prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the top, bottom, left, right, and rear of the
switch. Do not connect the switch to the AC power source until instructed to do
so later in the installation process.
• During operation, ambient temperature at the installation site must be
maintained between 0° and 50°C (32° to 122°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
• Refer to installation document for details.
Failure to follow these instructions can result in equipment damage.
Functional Specifications
Ethernet Standards Supported • IEEE 802.1q VLAN support
• IEEE 802.1d MAC Bridging (including STP)
• Quality of Service (QoS, Priority) IEEE 802.1w Rapid Spanning Tree
(RSTP) IEEE 802.3 including:
◦ Fast Ethernet: IEEE 802.3u, 100Base-T (Copper)
◦ Gigabit Ethernet: IEEE 802.3z, 1000Base-X (Fiber)
◦ Gigabit Ethernet: IEEE 802.3ab, 1000Base-T (Copper)
Power • Internal:
AC Input power (auto-sensing)
100 VAC to 240 VAC, 50 to 60 Hz +/- 5%
• External:
Supports connection for redundant power supply
• Heat Dissipation:
172 Btu/Hr
• Power Consumption:
26 Watts
• Maximum Power Consumption:
51 Watts
Environmental Specifications
Operating Storage
Temperature 0° to 50°C (32° to 122°F) -40° to +70°C (-40° to +158°F)
Relative Humidity 10 to 95% (non-condensing) 10 to 95% (non-condensing).
Altitude 0 to 3,000 meters (9,850 feet)
Physical Specifications
Mounting Desk or Enclosure: 48.3 cm (19 in) equipment rack, 1U high
Dimensions (Nominal) • Height: 4.4 cm (1.7 in)
• Width: 44.1 cm (17.36 in)
• Depth: 25.4 cm (10.1 in)
Weight (Approximate) 3.73 kg (8.22 lb)
Cable Connectors • Uplink Ports: RJ-45 copper or LC fiber
Vibration • Vibration: IEC 60068-2-64, IEC 60068-2-6
• Shock: IEC 60068-2-27
• Drop: ETSI/EN 300 019 2-2
Features
The 24-Port Copper X440-G2 managed switch features:
• 24 ports of Tri-speed 10/100/1000Base-T.
• Four 1000Base-X uplink Gigabit (SFP) ports (the SFP ports are located on the
back of the unit).
• RJ-45 Category 5 connectors on switch copper ports.
• Full-duplex operation.
• Configuration tasks through a local console port and monitoring through any
SNMP/RMON based management application.
• Port mirroring technology and diagnostics that allow local network traffic to be
redirected to an external probe for detailed analysis.
• Compliance with industry standards, including IEEE 802.3u Fast Ethernet and
802.1w Rapid Spanning Tree Protocol (RSTP).
• Optional external redundant power supply.
• Shelf, desk, or 19-inch rack mounting.
All X440-G2 switches ship with fixed fans and power supplies.
Physical Specifications
Mounting Desk or Enclosure: 48.3 cm (19 in) equipment rack, 2U high
Dimensions (Nominal) • Height: 4.5 cm (1.77 in)
• Width: 15.42 cm (6.07 in)
• Depth: 34.0 cm (13.39 in)
Weight (Approximate) 2.1 kg (4.63 lb.)
Power Supply Slots Three slots for redundant power supplies (RH102AX)
Features
The redundant power supply for the DCS Control Network qualified switches:
• Desktop, shelf, rack mounting
• The RH102AW RPS is a “Brick” style power supply and can be installed in any
location
• Up to 90 W of power per supply
Functional Specifications
Power • AC Input Range:
90 VAC to 264 VAC Hz, 47 to 63 Hz
• Output:
+19.0 VDC, 90 Watts
Environmental Specifications
Operating Storage
Temperature 0° to 60°C (32° to 140°F) -40° to +70°C (-40° to +158°F)
Relative Humidity 10 to 95% (non-condensing) 10 to 95% (non-condensing)
Features
The redundant power supply for the DCS Control Network qualified switches:
• Support for up to three managed switches (one supply/switch)
• Desktop, shelf, or 19-inch rack mounting
• Up to 156 W of power per supply
Functional Specifications
Power • AC Input Range:
90 VAC to 264 VAC, 47 to 63 Hz
• Output:
+12.0 VDC, 13 A Max
102 W or 156 W continuous
Environmental Specifications
Operating Storage
Temperature 5° to 60°C (41° to 140°F) -45° to +85°C (-49° to +185°F)
Relative Humidity 10% to 90% (non-condensing) 10% to 90% (non-condensing)
Physical Specifications
Mounting Redundant power supply chassis (RH102AV for three RPS)
Dimensions (Nominal) • Height: 4.1 cm (1.61 in)
• Width: 15.4 cm (6.1 in)
• Depth: 30.0 cm (11.8 in)
Weight (Approximate) 1.5 kg (3.3 lb)
GBICS
GBICs convert serial electrical signals to serial optical signals and vice versa. GBIC
modules are hot swappable and contain ID and system information for the switch.
GBICs: Non-Industrial
• RH102AL: 100 m (328 ft) RJ-45 MGBIC Uplink module (TX) 10/100/1000Base-T
• RH102BK: 100Base-FX 2 km (1.24 mi) MGBIC device module LC (1310 N-m)
• RH102BQ: 10 Gb SR SFP+ module 300 m (984 ft) MMF 850 N-m
• RH102BR: 10 Gb LR SFP+ module 10 km (6.2 mi) SMF
• RH102BS: 10 Gb LRM SFP+ module 220 m (656 ft) MMF, 300 m (984 ft) SMF
• RH102BT: 10 Gb ZR SFP+ module 80 km (49.7 mi) SMF
• P0973JB: Bi-directional Uplink 10K MGBIC module LC LX (1310 N-m)
• P0973JC: Bi-directional Downlink 10K MGBIC module LC LX (1490 N-m)
• P0973JD: Bi-directional MGBIC Kit containing both Downlink and Uplink 10K
MGBIC
• P0973KM: Bi-directional Uplink 40K MGBIC module BX (1310 N-m)
• P0973KN: Bi-directional Downlink 40K MGBIC module BX (1490 N-m)
• P0973KP: Bi-directional MGBIC Kit containing both Downlink and Uplink 40K
MGBIC
• P0973KQ: Bi-directional Uplink 120K MGBIC module BX (1490 N-m)
• P0973KR: Bi-directional Downlink 120K MGBIC module BX (1590 N-m)
• P0973KS: Bi-directional MGBIC Kit containing both downlink and uplink 120K
MGBIC
PSS 41H-1FCP280
Product Specification
October 2020
https://www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished
for informational use only. No part of this guide may be reproduced or transmitted in
any form or by any means (electronic, mechanical, photocopying, recording, or
otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as is"
basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
Overview Field Control Processor 280 (FCP280)
Overview
The EcoStruxure™ Foxboro™ DCS Field Control Processor 280 (FCP280) is a
distributed, optionally fault-tolerant, field-mounted controller module. The FCP280
performs regulatory, logic, timing, and sequential control together with connected
Foxboro DCS Fieldbus Modules (FBMs). It also performs data acquisition and alarm
detection and notification. The FCP280 connects to the Foxboro DCS Control
Network via standard fiber optic or copper 100 Mbps Ethernet cables from network
adapters installed on its baseplate (see the next figure).
The FCP280 requires Foxboro DCS Control Core Services software v9.0 or later. A
system with the FCP280 and this software is called an EcoStruxure Foxboro DCS
Process Automation System.
Legend
A To/From Control Network Ethernet Fiber Switch “B”
B 100 Mbps Orange Duplex Fiber Cable
C To/From Control Network Ethernet Fiber Switch “A”
D FCP280 Fault-Tolerant Module Pair
E Each Fieldbus Port (1-4. Top 1, Bottom 4) can connect to fieldbus with Compact
and/or standard 200 Series FBMs, or 100 Series FBMs in a pre-approved
configuration
F Liquid Crystal Display
G Operational LED’s for module state and Fieldbus communication
H Down-Arrow Button
I Up-Arrow Button
J Select Button
K Network Adapters (Fiber Adapters Shown, Copper Adapters available)
L Operational LEDs for communication status to/from the Control Network
The fault-tolerant version of the FCP280 consists of two processor modules. These
modules are installed in adjacent FCP280 slots in dedicated baseplates for high
speed communication between the modules.
The FCP280 accepts four PIO channels (that is, four separate HDLC fieldbuses) via
the four Fieldbus ports on its baseplate. These four Fieldbuses are referred to
collectively as the “Expanded fieldbus.”
An optional dual cable baseplate is available that supports four PIO channels, but
separate A versus B bus connectors are provided along with dedicated connectors for
the optional Time Strobe inputs.
Fieldbus connections from the optional dual cable baseplate to standard or compact
200 Series FBMs require separate A versus B bus cables plus a dual “D” connection
adapter on the FBM baseplate (RH926KW).
The number of FBMs that an FCP280 can support varies depending on the types of
FBMs used:
• 200 Series FBMs exclusively used with FCP280 - Each Fieldbus port on the
FCP280 baseplate can connect to a baseplate chain with up to 32 Compact or
standard 200 Series FBMs per chain via the 2 Mbps HDLC fieldbus for up to 128
modules.
• 200 Series and 100 Series FBMs (dual baud configurations) used with FCP280.
The FCP280 can support a total of 128 100 Series FBMs (Y-module) or
competitive devices (such as Foxboro DCS system migration FBMs) in one or
more baseplate chains, with the remainder of the FCP280’s 128 module limit
being 200 Series FBMs, depending on the Fieldbus loading of the FCP280. For
example, an FCP280 could support 64 100 Series FBMs and 64 200 Series
FBMs (as 64 + 64 = 128). Main and expansion FBMs are considered as two
FBMs for counting purposes. As well, no more than 64 100 Series FBMs are
allowed on each PIO bus/baseplate port. See the next two figures.
NOTE: Certain competitive migration or supported third-party modules such as
the EcoStruxure Foxboro DCS Process Automation System Migration Fieldbus
Modules and Pepperl+Fuchs™ I/O modules may increase this 128 module
maximum per FCP280. For the maximum numbers of each of these migration/
third-party modules supported by the FCP280, see the supported migration
products books in Field Control Processor 280 (FCP280) User’s Guide
(B0700FW).
NOTE: The dual cable baseplate does not support connections to 100 Series
FBMs or equivalent competitive migration and third-party modules.
NOTE: Although the FCP280 is capable of communicating with the maximum
number of FBMs (128), some restrictions may constrain a useful control system's
design, thereby limiting the number of FBMs that can be installed.
When supporting 200 Series and 100 Series FBMs, each Fieldbus port (PIO channel)
is dedicated to supporting either a 268 Kbps HDLC fieldbus (for 100 Series FBMs) or
a 2 Mbps HDLC fieldbus (for 200 Series FBMs) — not both.
For connections to 100 Series FBMs, an FBI200 pair is required to extend
communications up to 1,830 m (6,000 ft). See the next figure.
NOTE: When replacing a CP10, CP30, CP40, or CP60 with a FCP280 and
keeping all its 100 Series FBMs, an FBI200 is required to be installed between the
CP and FBMs to reduce potential system messages.
The Fieldbus splitter (RH928CV) is used to directly connect a Fieldbus port to a 268
Kbps HDLC fieldbus. This provides a connector for any Fieldbus port on the FCP280
baseplate, and two Termination Cable Assembly (TCA) termination blocks for the
twinaxial cabling from the 100 Series FBMs.
The FCP280 can also communicate with serial and Ethernet devices, such as PLCs,
via Field Device System Integrators (special FBMs). This allows you to connect to
new device interfaces without any changes to the controller software.
To estimate the FCP280’s processor load, see Field Control Processor 280 (FCP280)
Sizing Guidelines and Excel Workbook (B0700FY).
For a description of the FCP280 baseplates, see Standard 200 Series Baseplates
(PSS 41H-2SBASPLT).
Figure 2 - Typical FCP280 Network Configuration with Mixed 100 Series and 200 Series FBM Functionality
(Simplified)
F F F F F F F F F F F F F F F F
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
FBM
B B B B B B B B B B B B B B B B
M M M M M M M M M M M M M M M M
The FCP280 supports up to 128 FBMs, which can consist of one of these options: 128
200 Series FBMs, 128 100 Series FBMs, or a mix of 128 200 Series and 100 Series
FBMs. If you use a mix of 100 Series and 200 Series FBMs, the FBMs cannot be
mixed concurrently on the same PIO channel. Each PIO channel must be configured
to either a 268 Kbps or 2 Mbps HDLC fieldbus.
The 100 Series FBMs can be connected to any fieldbus port on the FCP280
baseplate, provided that the overall FBM limit of 128 100 Series FBMs is maintained
for the FCP280. Up to 64 100 Series FBMs are supported on each PIO channel/
baseplate port.
An FBI200 may be included on this connection to extend the distance between the
100 Series FBIs and the FCP280 baseplate. In mixed configurations (100 and 200
Series FBMs) the FCP280 can communicate on the 268 Kbps HDLC fieldbus up to 60
m (198 ft). When communicating with a 268 Kbps HDLC fieldbus only, the FCP280
can communicate on this fieldbus up to 1 km (3,200 ft). The FBI100 pair may be used
in place of FBI200s. For sizing constraints and devices supported by the FBI200, see
FBI200 Fieldbus Isolator/Filter (PSS 41H-2FBI200). For sizing constraints and
devices supported by the FBI100, see FBI100 Fieldbus Isolator/Filter (PSS 21H-2Y16
B4). The FBI200/FBI100 extends the distance of the HDLC fieldbus between the
FCP280 and the FBMs up to 1,830 m (6,000 ft). The FBI200 can be used with 200
Series FBMs as well to extend the cabling distances to them. The FBI100 is used
exclusively with 100 Series FBMs to extend the cabling distances to them.
Figure 3 - Typical FCP280 Network Configuration with Exclusive 100 Series FBM Functionality (Simplified)
The Foxboro DCS Control Network
Switch Switch 100 Series FBMs can be connected to any Fieldbus port on FCP280
baseplate, provided that port is used exclusively with 100 Series FBMs.
Termination Cable Assembly
FCP280 Standard Vertical Baseplate Termination Block (RH928CV)
Fiber optic
cabling - A
Fiber B
Copper cabling adapters
A
can be used as well FCP FCP B
when copper adapters
are installed in the 280 280
FCP280 baseplate.
Refer to B0700FW for the list
of switches which are not supported Twinaxial Cables
by the FCP280. 1 Km (3200 ft) Maximum
(P0170GF or P0170GG)
- See second Note
below B A B A
To other FBIs To other FBIs
1x8 Mounting Structure 1x8 Mounting Structure
I O I O I O I O
The FCP280 supports up to 128 100 Series FBMs total. Up to 64 100 Series FBMs
are allowed on each PIO port/Fieldbus port.
The FBI200 is needed only to extend the distance between the 100 Series FBIs and
the FCP280 baseplate. When communicating with a 268 Kbps HDLC fieldbus only,
the FCP280 can communicate on this fieldbus up to 1 km (3,200 ft). FBI100 pair may
be used in place of FBI200s. For sizing constraints and devices supported by the
FBI200, see FBI200 Fieldbus Isolator/Filter (PSS 41H-2FBI200). For sizing
constraints and devices supported by the FBI100, see FBI100 Fieldbus Isolator/Filter
(PSS 21H-2Y16 B4). The FBI200/FBI100 extends the distance of the HDLC fieldbus
between the FCP280 and the FBMs up to 1,830 m (6,000 ft). Twinaxial cables over 1
km (3,200 ft) are customer supplied.
The RH928CV splitter has a 3 m (9.8 ft) cable between the fieldbus port connector
and TCA termination block.
Features
• Performs regulatory, logic, timing, and sequential control together with connected
Foxboro DCS Fieldbus Modules (FBMs)
• Performs data acquisition and alarm detection and notification
• Supports up to 128 Compact or standard 200 Series FBMs, 128 100 Series
FBMs, or up to 128 of a combination of 100 Series FBMs and 200 Series FBMs,
and no Fieldbus Communication Module is required (a maximum of 64 100
Series FBMs are allowed on each PIO bus/baseplate port)
• No Fieldbus Expansion Module is required for Expanded Fieldbus support
• Supports self-hosting mode, which allows the FCP280 to boot itself with a valid
control database even without its host workstation being on-line. However, editing
control functions will not be possible.
• Offers unique, patented, fault-tolerant operation using two control modules to
greatly improve reliability relative to other process controllers
• Offers on-line image upgrade (OLUG) of a fault-tolerant FCP280
• Offers an enhanced on-line image upgrade (EOLUG) of a fault-tolerant FCP280
while the process is running. This form of upgrade helps prevent any significant
bumps to the local control process.
• Offers CP Overload Protection, that notifies an operator if an FCP280 is being
pushed toward its performance limits
• Liquid Crystal Display (LCD) displays letterbug and real-time roles and statuses
• Connects to the Foxboro DCS Control Network via standard fiber optic or copper
100 Mbps Ethernet cables
• Uses a rugged, die cast aluminum housing for mounting in a non-vented field
enclosure
• Can operate in Class G3 harsh environments
• CE certified for field mounting in enclosures
• Each fieldbus port on standard FCP280 baseplates supports either a 2 Mbps or
268 Kbps HDLC fieldbus exclusively
• Uses versatile control algorithms and a wide variety of FBMs to provide control
capabilities for a broad range of process applications
• Supports time synchronization using optional external time from GPS satellites
• Uses soft letterbugs configurable via the keys on the FCP280 faceplate
• The optional dual cable baseplate enables separate cables to be used for each
“A” and “B” bus
The fiber or copper adapters mount on the FCP280 baseplate as shown in Fault-
Tolerant FCP280 Module Pair Mounted on Vertical Mounted 2-Position FCP280
Baseplate, page 4. They receive their power from the baseplate.
Remote Mounting
The FCP280 simplifies the Foxboro DCS System architecture, maintaining control
while only requiring housing (via field enclosures), host workstations with the Control
Core Services v9.0 or later, and Ethernet switches for communication via the Control
Network architecture. For more information, see The Foxboro DCS Control Network
Ethernet Equipment (PSS 41H-7NWEQUIP).
The field-mounted FCP280 is an integral part of the highly-distributed Control Network
where controllers are closely aligned to specific process units mounted in close
proximity to their I/O and the actual equipment being controlled. Coordination between
process units takes place via a fiber optic 100 Mbps Ethernet network.
The FCP280 and its network adapters are packaged in a rugged, die cast aluminum
housing that does not require venting due to its efficient design. The FCP280 and its
network adapters are CE certified, and it can be mounted without expensive special
cabinets to help prevent electronic emissions. The FCP280, network adapters, and
baseplate can be mounted in Class G3 harsh environments.
Upgrade Options
Multiple options are available for replacing existing control processors with the
FCP280. A fault-tolerant FCP280 may replace a fault-tolerant FCP270 or ZCP270. It
may import the CP database from the CP270 it is replacing, for compatibility and
minimal configuration time.
The FCP280 provides an increase in performance and block processing capacity over
the CP270s. When replacing the FCP270s with the FCP280, you do not need the
FEM100 hardware.
For ease of replacement, the fault-tolerant or non-fault-tolerant FCP280 in the
standard baseplate has the same dimensions as the fault-tolerant or non-fault-tolerant
FCP270 in its baseplate.
The dual cable baseplate has larger dimensions than the standard baseplate.
Cabling the 100 Series FBMs or Migration products to an FCP280 baseplate consists
of extending the remote 268 Kbps fieldbus between enclosures. This is accomplished
using termination cable assemblies (TCAs) and Fieldbus Isolators (FBIs) to provide
connections between primary and extended fieldbus segments.
The optional FBI200 can extend the 2 Mbps HDLC fieldbus between 200 Series FBMs
from 60 m (198 ft) up to 305 m (1000 ft). As well, for standard FCP280 baseplates, it
can extend the 268 Kbps HDLC fieldbus between 100 Series FBMs from 60 m (198 ft)
in a mixed 100 & 200 Series FBMs configuration (or 300 m (1,000 ft) in an exclusive
100 Series FBMs configuration) up to 1830 m (6,000 ft).
As with earlier generations of control processors, up to 128 100 Series FBMs
(including expansion modules) attach to standard baseplate Fieldbus ports through
Fieldbus Isolators (with a maximum of 64 100 Series FBMs per port). Up to 24 100
Series FBMs, excluding expansion modules, can connect to each isolator. However,
the expansion modules are considered 100 Series FBMs in this “128 100 Series
FBMs” maximum discussed in this PSS. Available upgrade scenarios are available in
Field Control Processor 280 (FCP280) User’s Guide (B0700FW).
Devices Supported
The FCP280 supports the following devices on the 2 Mbps fieldbus:
• All Compact and Standard 200 Series FBMs, which can support many types of
intelligent field devices, including those on Foundation Fieldbus, PROFIBUS,
HART, and DeviceNet networks
• Foxboro DCS Field Device Systems Integrator (FDSI) modules
• Intrinsically Safe I/O Subsystem (ISCM) - see Intrinsically Safe I/O Subsystem
(PSS 31H-2Y6)
• DCS Migration Fieldbus Modules for Siemens APACS+ Systems
• DCS Migration Fieldbus Modules for Westinghouse WDPF® Systems
• DCS Migration Fieldbus Modules for Fisher's PROVOX® Series 20 Migration with
HART
• DCS Migration Fieldbus Modules for Honeywell® TDC 2000 Systems with HART
Using the standard baseplate, the FCP280 supports the following devices on the 268
Kbps fieldbus:
• 100 Series FBMs
• SPECTRUM™ Migration Integrators
• SPEC 200™ Control Integrators
• SPEC 200 MICRO™ Control Integrators
• SPEC 200 CCM Control Integrators
The Foxboro Gas Chromatograph is not supported.
The FCP280 supports the 100 Series Fieldbus Module Upgrade subsystem, with the
optional FBI200A modules. See 100 Series Fieldbus Module Upgrade Subsystem
Overview (PSS 41H-2W100).
FCP280 Baseplate
The FCP280 is installed on a modular, DIN rail mounted baseplate in a dedicated slot
that is keyed for the controller so that modules are not misplaced. The available
FCP280 baseplates are shown in this figure.
2
3
4
1B
1A
2B
2A
3B
3A
4B
4A
termination. All four Fieldbus port pairs (A/B) on the dual cable baseplate are
internally terminated by default without the use of DIP switches.
The FCP280 baseplates can be added in the field to existing or new configurations.
The standard FCP280 baseplates have similar dimensions as the FCP270 2-position
baseplates for ease of replacement, while the dual cable baseplates are larger and
wider.
When upgrading existing CP60 systems to use FCP280s, you can recover an
additional two FBM positions after removing the old FCM10E/FCM10Efs.
The following splitters and terminators can be used with FCP280 baseplate:
• The Fieldbus Baseplate Terminator (P0916RB) is used to terminate either the CP
end of the HDLC fieldbus or the last 200 Series baseplate in the daisy chain when
Time Strobe or split A/B fieldbus cables are not required.
(RH928CY)
• Time Strobe Fieldbus Baseplate Terminator (RH924ZQ) connects the optional “A”
and/or “B” time strobe signals to the standard FCP280 baseplates only. The Time
strobe splitter/terminator RH924ZQ is used on only the first standard baseplate
containing an FCP280. This terminator also terminates the fieldbus signals.
NOTE: The RH924ZQ adapter is not used with the dual cable FCP280
baseplate.
• Fieldbus Splitter (RH928CV) allows any of the Fieldbus ports on the standard
FCP280 baseplates to connect to the twinaxial 268 Kbps fieldbus cables.
RH928CV includes both a connector to any of the Fieldbus ports on the FCP280
baseplate, and a termination cable assembly (TCA) termination block similar to
two of the P0903VY termination blocks joined together.
(RH928CV -
FCP280 Baseplate
FCP280 Only)
Fieldbus Port
Connector
Termination
Cable Assembly
Termination
Block
Fieldbus B Fieldbus A
LED Indicators
Light-emitting diodes (LEDs) on the front of the FCP280 module provide visual
indication of the:
• FCP280 operational status
• Transmit/receive communications activity of four expanded fieldbus channels,
fieldbus A and B for each
LED indicators on the copper or fiber network adapters provide visual indication for:
• Internal and external power supply health status
• Communications activity to the Control Network A and B links, and to the
FCP280(s)
guidelines, see Field Control Processor 280 (FCP280) Sizing Guidelines and Excel
Workbook (B0700FY).
Minimum Block 50 ms
Processing Cycle (BPC)
Sequence Block Size 32 kB maximum for each block
Maximum Number of 231; 200 connections for source points; 30 connections for sink points; 1 connection for
IPC Connections internal use only.
The environmental limits of this module may be enhanced by the type of enclosure
containing the module. See the applicable Product Specification Sheet (PSS) that
describes the specific type of enclosure to be used.
116 mm
4.59 in 105 mm
(including 4.13 in
mounting
lugs)
147 mm
5.8 in
51.8 mm
2.04 in
Regulatory Compliance,
• Underwriters Laboratories (UL) for U.S. and Canada:
Product Safety
UL/UL-C listed as suitable for use in Class I, Groups A-D; Division 2; temperature
code T4 enclosure based systems. Communications circuits also meet the
requirements for Class 2 as defined in Article 725 of the National Electrical Code
(NFPA No.70) and Section 16 of the Canadian Electrical Code (CSA C22.1).
Conditions for use are as specified in Standard and Compact 200 Series
Subsystem User’s Guide (B0400FA).
• European Low Voltage Directive 2014/35/EU and Explosive Atmospheres (ATEX)
Directive 2014/34/EU:
ATEX (DEMKO) Ex nA IIC T4 Gc certified when connected as described in the
Standard and Compact 200 Series Subsystem User’s Guide (B0400FA). For use
in an enclosure suited for an ATEX Zone 2 classified area.
• Marine Certification:
Bureau Veritas Marine Certification for Environmental Category EC31C.
NOTE: These products are NOT marine certified: Dual Cable FCP280
Baseplate (RH100JX).
The environmental limits of the 200 Series baseplates may be enhanced by the type
of enclosure containing the 200 Series baseplate. See the applicable Product
Specification Sheet (PSS) that describes the specific type of enclosure to be used.
Related Documents
Document Number Description
PSS 41H-2SOV Standard 200 Series Subsystem Overview
PSS 41H-2W100 100 Series Fieldbus Module Upgrade Subsystem
Overview
PSS 41H-2CERTS Standard and Compact 200 Series I/O - Agency
Certifications
PSS 41H-2FPS400 Standard 200 Series Power Supply
PSS 41H-2W4 Termination Assembly Adapter Modules for 100 Series
Upgrade
PSS 41H-2SBASPLT Standard 200 Series Baseplates
PSS 41H-2FPS Standard 200 Series Power Supplies - FPS240-24 and
FPS120-24
PSS 41H-2W8 100 Series Conversion Mounting Structures
PSS 41H-2COV Compact 200 Series I/O Subsystem Overview
PSS 41H-2CERTS EcoStruxure Foxboro DCS Standard and Compact 200
Series I/O - Agency Certifications
PSS 41H-2C480 Compact Power Supply - FPS480-24
PSS 31H-2Y6 Intrinsically Safe I/O System
PSS 41H-2Y17 FBI200A Fieldbus Isolator/Filter
PSS 41H-2FBI200 FBI200 Fieldbus Isolator/Filter
PSS 41H-2GOV G-Series Enclosures Overview
PSS 41H-7NWEQUIP The Foxboro DCS Control Network Ethernet Equipment
PSS 41S-1TIME Time Synchronization Overview
PSS 41S-3FCPICS Field Control Processor 280 (FCP280) Integrated Control
Software
B0700FY Field Control Processor 280 (FCP280) Sizing Guidelines
and Excel Workbook
B0700FW Field Control Processor 280 (FCP280) User’s Guide
B0400FA Standard and Compact 200 Series Subsystem User's
Guide