Kentledge-240 MT

The document outlines the arrangements for a vertical pile load test in Odisha, specifying a design load of 240 MT and a test load of 600 MT. It details the components used, including hydraulic jacks, pressure gauges, and the kentledge load calculations, which total 761.566 MT. Additionally, it provides a load increment chart for the testing process.

Uploaded by

Amit G Singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views3 pages

Kentledge-240 MT

The document outlines the arrangements for a vertical pile load test in Odisha, specifying a design load of 240 MT and a test load of 600 MT. It details the components used, including hydraulic jacks, pressure gauges, and the kentledge load calculations, which total 761.566 MT. Additionally, it provides a load increment chart for the testing process.

Uploaded by

Amit G Singh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ARRANGEMENTS OF VERTICAL PILE LOAD TEST (INITIAL) AT ODISHA

Design Load: 240 MT Test Load: 240x2.5=600 MT Kentledge Load: 750M.Ton


(As per IS 2911 Part – IV) Dai of Pile= 1200mm

Sand Bags

3.15M Loose Sand

ISMB 450 (17 Nos.)

PRIMARY GIRDER --------- ISMB 600-4 NOS.12.2 M LONG


Steel/Sleeper
.
Sand Filled
Bags

Dial Gauge Datum bar

1000 MT Hydraulic Jack 1 no.


Hydraulic Pump
M.S. Plate
Test Pile Pressure Gauge

Hydraulic Manifold

DETAILS OF KENTLEDGE 12 m (A1)


(A + A2 +₁ × ₂) 11.5m (A2)
 1 12 m (A1)
. .
= (144+ 132.25+√144 × 132.25)= (144+ 132.25+ 138) =434.961m3 11.5m (A2)
 

Avg. weight of wet sand: 1700 Kg. /M3


Total weight of wet sand: (434.961M3× 1700 Kg. /M3) = 739.433MT.
ISMB 600 : 4 nos.×12.20 m@ 122.6 kg/m = 5.983MT
ISMB 400 : 17 nos.×12.20 m @ 72.40kg/m = 15.015MT
Reinforcement Steel :L.S =1.000 MT.
Total Weight of Kentledge=761.566MT > 750M.T.
DETAILS OF JACK
Jack : 1000 M.T. Capacity 1 No. Hydraulic
Jack With pump

Ram dia : 50.00 cm.

Area of Ram : 1963.75 cm2

DETAILS OF PRESSURE GAUGE


Gauge : “MASTA“ Made in England

Least Count : 20 kg/cm2

Per Div : 39.275M.T.

DETAILS OF DIAL GAUGE

Gauge : “Mitutoyo”Made in Japan

Least Count : 0.01 mm

Range : 0- 50mm

No of dial gauge : 4 Nos.


Design Load = 240MT
Load application & increment = 240x 20% = 48.00 MT.
Test load = (240x 2.5) = 600MT

LOAD INCREMENT CHART


LOAD IN DIVISION LOAD IN M.TON.
0 DIV 0.00
1 DIV 39.275
2 DIV 78.550
3 DIV 117.825
4 DIV 157.100
5 DIV 196.375
6 DIV 235.650
7 DIV 274.925
8 DIV 314.200
9 DIV 353.475
10 DIV 392.750
11 DIV 432.025
12 DIV 471.300
13 DIV 510.575
14 DIV 549.850
15 DIV 589.125
15.5 DIV 608.762