ACRD601 Air Cooled Power Specs

The document provides specifications for the InRow RD, 600mm Air Cooled unit, including details on input voltage, dimensions, and operational capabilities. It highlights the product's environmental impact initiatives and compliance with safety certifications. Additionally, it outlines warranty information and packaging details.

Uploaded by

Loay Safieddine
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views3 pages

ACRD601 Air Cooled Power Specs

The document provides specifications for the InRow RD, 600mm Air Cooled unit, including details on input voltage, dimensions, and operational capabilities. It highlights the product's environmental impact initiatives and compliance with safety certifications. Additionally, it outlines warranty information and packaging details.

Uploaded by

Loay Safieddine
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Product data sheet

Specifications

InRow RD, 600mm Air Cooled,


460-480V, 60Hz
ACRD601

Overview
Lead time Special Order - Call for Quoted Lead Times

Main

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main Input Voltage 460 V 3 phase
480 V 3 phase

Number of rack unit 42U

Provided Equipment Door key


Installation guide
Integrated network management
Network Management Card
Operations and maintenance manual
User Manual

General
Compressor Type Scroll

Air Discharge Patterns Horizontal

Intake Air Rear Return

air flow 4000 ft³/min (1887.8 l/s)

Inrush current 28 A

Condensate Pump Capacity 32 Gal/hr(US) (0.1 m3/h)

Piping Material Copper

Physical
Color Black

Height 78.39 in (199.1 cm)

Width 23.62 in (60 cm)

Depth 42.13 in (107 cm)

Net Weight 862.008 lb(US) (391 kg)

Mounting preference No preference

Mounting Mode Not rack-mountable

Input
Number of Power Feeds 1

Input power 14600 W

Minimum Circuit Amp Capacity 24 A

Mar 19, 2025 1


Input Frequency 60 Hz

Maximum Overcurrent Protection 40 A

Number of input connectors 1 Hard Wire 4-wire (3PH + G)

Conformance
Product Certifications cUL Listed
UL Listed

Environmental
Ambient air temperature for -4…122 °F (-20…50 °C)
operation
Relative Humidity 5…95 %

Operating altitude 0...10000 ft

Acoustic level 84 dBA

Communications & Management


control panel Multi-function LCD status and control console

Ordering and shipping details


GTIN 731304326717

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Height 85.28 in (216.6 cm)

Package 1 Width 44.76 in (113.7 cm)

Package 1 Length 33.46 in (85 cm)

Package 1 Weight 961.2 lb(US) (436 kg)

Number of Units in Package 3 1

Contractual warranty
Warranty 1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up

2 Mar 19, 2025


Environmental Data

Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.

Environmental Data explained

Use Better

Materials and Substances

Packaging made with recycled cardboard No

Packaging without single use plastic No

EU RoHS Directive Not applicable, out of EU RoHS legal scope

"WARNING: This product can expose you to chemicals


including: Lead and lead compounds, which is known to
California proposition 65 the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to
[Link]"

Use Again

Repack and remanufacture

Take-back No

Mar 19, 2025 3

Common questions

Powered by AI

The InRow RD unit addresses thermal management by using a horizontal air discharge pattern and a rear air intake design, allowing efficient cooling of server racks by closely coupling the cooling mechanism with the racks. This method limits air mixing and maximizes cooling efficiency by delivering cooling directly to the heat source. Additionally, the unit handles a return air flow of 4000 ft³/min, ensuring optimal thermal regulation within the data center environment.

The integrated network management capability allows for real-time monitoring and control of the unit, contributing to predictive maintenance, operational efficiency, and system reliability. This feature enables remote management and integration with building management systems, providing crucial data on performance metrics, allowing for timely adjustments and ensuring consistent cooling within the data center. It is essential for proactive management in dynamic IT environments.

California Proposition 65 requires warning labels on products containing chemicals known to cause cancer or reproductive harm. The InRow RD unit contains lead compounds, necessitating these warnings. Managing these risks involves understanding the potential exposure pathways and ensuring that installation and maintenance personnel are informed and equipped to handle the unit safely, potentially through the use of protective gear and adherence to safety protocols. These measures help mitigate health risks associated with handling the unit.

The InRow RD unit is relatively large and heavy, with dimensions of 78.39 inches in height and a weight of 862.008 pounds. These factors can present logistical challenges during installation, requiring adequate space and equipment to maneuver. Its non-rack-mountable nature may also complicate integration into existing data center setups. Maintenance considerations include managing its high acoustic level of 84 dBA and ensuring the unit's air intake and discharge paths remain unobstructed to maintain optimal performance.

The "Use Better, Use Longer, Use Again" campaign aims to extend product lifetimes and increase recyclability, which aligns with Schneider Electric's goal to achieve Net Zero status by 2050. This campaign involves partnerships across the supply chain, the use of lower impact materials, and promoting circularity. The emphasis on sustainable practices and materials is significant as it contributes to reducing environmental impact and aligns with global sustainability initiatives.

The documentation highlights that the product packaging is made with recycled cardboard, and there is no single-use plastic in packaging, demonstrating a commitment to sustainability. The unit, however, is not under the legal scope of the EU RoHS Directive, which means it does not necessarily comply with restrictions on hazardous substances. Additionally, California Proposition 65 warns that the product contains lead compounds, known to cause cancer and reproductive harm.

The InRow RD unit is cUL Listed and UL Listed, which indicates that it complies with North America’s safety standards. These certifications imply that the unit is safe for installation in regions where these standards are recognized, ensuring that the product meets established safety and reliability criteria, such as electrical safety and construction. This is crucial for installations in facilities that require adherence to rigorous safety protocols.

The warranty provides a one-year parts-only coverage and a one-year on-site repair or product replacement, aligning with Schneider Electric's sustainability goals by emphasizing durable, long-lasting products that minimize waste. This warranty supports the company's "Use Longer" principle by ensuring the product remains operational over an extended period, reducing the need for premature disposal and replacement. This approach aids in extending the lifetime of products, which is a key component of their sustainability strategy.

The unit is designed to operate within a wide temperature range of -4° to 122°F and can handle 5% to 95% relative humidity. This operational flexibility allows it to function effectively in diverse environmental conditions, making it suitable for varying climates and indoor settings. This adaptability ensures consistent performance and reliability, crucial for maintaining IT equipment stability in locations with fluctuating ambient conditions.

The InRow RD unit utilizes a scroll compressor, which is known for its efficiency, reliability, and reduced noise levels compared to other types. Scroll compressors are particularly effective in providing consistent and stabilized cooling output, which is beneficial for maintaining optimal temperature conditions in critical environments like data centers. The configuration supports the unit's horizontal air discharge pattern and contributes to the unit's overall reliable performance.