EAE Pano Catalog 2023 Overview
EAE Pano Catalog 2023 Overview
C ATA L O G
2 0 2 3 - 1
1
About Us
EAE Group
5 factories
EAE Group has a total of five factories
Since 1973 in Istanbul and Kocaeli.
EAE Group of Companies has started its
journey in the electricity sector with EAE
Elektrik, which has founded in 1973.
Export
to more than 100 countries
EAE Group also has distributors and authorized dealers
in more than 100 countries.
3 R&D Centers
280.000 m2 closed There are 3 R&D centers in total,
2 of them are in Kocaeli.
area
EAE group is spread over a total closed area
of 280.000 m2 with its 5 factories.
EAE Globally...
2
EAE Elektroteknik A.Ş.
Active in energy distribution, industrial automation and data processing business EAE Elektroteknik A.Ş. is
committed to continuous innovation to improve performance of installations in infrastructures as well as industrial
and commercial sites.
Throughout its history it has constantly anticipated market changes by developing pioneering designs, providing
solutions that are adapted to customer requirements and fully in compliance with international standards.
EAE Elektroteknik A.Ş. applies lean manufacturing methods throughout its entire operation and follows integrated
management systems.
Experience
EAE Elektroteknik has 20 years experience.
3
EAE Elektroteknik
Our solutions…
4
Type-Tested Empty Electrical Enclosures
5
General Features…
High Corrosion Resistance
Even if the product is painted, pre-galvanized
steel sheet is used in all products of the
E-Kabin brand.
6
Simplicity
Symmetrical design
Single bolt type
Flat-packed Shipment
7
EAE Elektroteknik reserves the right to make changes in the information contained in this catalog without notice.
8
CONTENTS
WALL-MOUNTED ENCLOSURES
O and M Series 11
HM Series Outdoor 19
XM Series Stainless Steel 25
E Series 31
Wall-Mounted Enclosure Accessories 37
TERMINAL BOXES
T Series 59
XT Series Stainless Steel 65
Terminal Box Accessories 69
CONSOLES
K Series 71
Console Accessories 75
FLOOR-STANDING ENCLOSURES
S Series 83
D Series 99
L Series 111
HS Series Outdoor - Modular 123
HF Series Outdoor - Monoblock 129
XS Series Stainless Steel - Modular 135
XH Series Stainless Steel - Monoblock 141
Floor-Standing Enclosure Accessories 147
9
WALL-MOUNTED ENCLOSURES O SERIES - M SERIES
10
E-Kabin O and M Series
Electrical Enclosures
11
Features
Support rails
Support rails increase the strength of the door and
allow attachment of equipment such as cables and
cable trays.
12
130° standard door opening
The door can be opened 130° wide with the
standard hinge set, thus full access is provided
during assembly.
130 °
13
Order Codes For EO Series
200 150 EO 30 20 15 1 2
300
300 200 EO 30 30 20 1 2
300 150 EO 40 30 15 1 2
400 300 200 EO 40 30 20 1 2
400 200 EO 40 40 20 1 2
350 150 EO 50 35 15 1 2
1 Lock and 2 Hinges
350 200 EO 50 35 20 1 2
500
400 200 EO 50 40 20 1 2
500 200 EO 50 50 20 1 2
400 150 EO 60 40 15 1 2
400 200 EO 60 40 20 1 2
400 300 EO 60 40 30 1 2
600
500 300 EO 60 50 30 1 2
600 200 EO 60 60 20 1 2
600 250 EO 60 60 25 1 2
500 200 EO 70 50 20 2 3
700
500 300 EO 70 50 30 2 3
600 200 EO 80 60 20 2 3
800 600 250 EO 80 60 25 2 3
600 300 EO 80 60 30 2 3
2 Locks and 3 Hinges
Note: Standard supply content: Mounting plate, bracket set, gland plate and earthing cable.
Dimensions
500 600
FLANGE OPENINGS
308 508
117.5 217.5
109
109
72
72
14
Dimensions
B C
20
20
17
A-46
A-5
A
M6
B-46
B-40
B+60
Ø13 Ø9
A+60
A-40
B-5
,5
R4
8
R6
,5
23
76
51
20
A-55
Ø9
25
B-124 Ø2,5 35
B-91
10
13
Usable area
Unless otherwise specified, all dimensions are in mm.
15
Order Codes For EM Series
Note: Standard supply content: Mounting plate, bracket set, gland plate and earthing cable.
Note: You can get information from your Customer Representative for large quantities and
different sizes.
Protection class is IP 54 for products with overlapping doors
Dimensions
1200 1000
508
109
16
Dimensions
20
20
B C
17 B-124
A-55
A-46
A-5
A
B-91
M6
8
R6
25
,5
23
Ø2,5
B-5
76
51
20
B-40 Ø9
B+60
Ø13 Ø9 10
35
A+60
13
A-40
B C
20
20
18
A-45
A-6
A
B-46
B-664
B-664
25
B-6 Ø4.6
A-56
A-56
17
HM SERIES
WALL-MOUNTED ENCLOSURES
Outdoor
18
E-Kabin HM Series
Outdoor Electrical Enclosures
19
Features
Stainless-steel hinge
Hinge body and pin made of stainless-steel material are
used as standard.
Asymmetrical canopy
It allows the use of bracket for wall mounting. Thanks
to their reverse angle edge design above door threshold,
rain water flows out of the enclosure.
20
Standard Door Opening 130°
The door can be opened 130° wide with the standard
hinge set, thus full access is provided during assembly.
130 °
Plinth
In applications where mounting on the floor is required,
plinth set accessory can be used additionally.
21
Order Codes
Note: Asymmetrical canopy module and mounting plate are included in standard supply content.
Dimensions
109
500 600
508
109
800
22
Dimensions
B C B+9
20
20
22
17
A-46
A+55
A+17
A-5
A
M6
300
B+9
B-46
22
B-5
A+72
A+17
400
A-55
25
Ø4,6
B-163
24
19
Usable area
.5
R4
8
B-40 R6
.5
22
B+60
50
80
Ø13 Ø9
A+60
20
A-40
Ø9
35
Unless otherwise specified, all dimensions are in mm.
23
XM SERIES
WALL-MOUNTED ENCLOSURES
Stainless Steel
24
E-Kabin XM Series
Stainless-Steel Electrical Enclosures
E-Kabin XM Series wall mounted stainless electrical enclosures Type of Mounting : Wall-Mounted
are designed as general purpose electrical equipment Modularity : Monoblock
enclosures for indoor and outdoor applications. They have Application : Indoor, Outdoor
monoblock body structure and provide IP66 protection degree. Protection Class : IP 66
Standard production does not include painting process. Standards : IEC 61439-1, IEC 62208
However, custom-made production, varnished or painted in the IEC 60529, IEC 62262
desired RAL code is possible. Environmental Class : According to EN 60721 - 3 - 3 IE37
Material : AISI 304 or 316 grade stainless-steel
XM Series stainless-steel enclosures can be produced with AISI Lock Set : Plastic - standard
304 or 316 grade raw material. Plastic lock is used in XM Series. Stainless-steel - optional
Optionally, a lock made of 304 or 316 grade stainless-steel can
also be used.
25
Features
Asymmetrical canopy
It allows the use of bracket for wall mounting. Thanks
to their reverse angle edge design above door threshold,
rain water flows out of the enclosure.
26
Stainless-steel hinge
Hinge body and pin made of Stainless-Steel material are
used as standard.
27
Order Codes
Note: Standard lock is plastic. If stainless-steel lock is requested, please indicate it in your purchase order.
Mounting plate is included in the standard supply content. Bracket set is not included in the standard supply content.
Note: Standard lock is plastic. If stainless-steel lock is requested, please indicate it in your purchase order.
Mounting plate is included in the standard supply content. Bracket set is not included in the standard supply content.
28
Dimensions
B C
A-46
A-5
A
M6
B-46
B-5
B-40
B+60
Ø13 Ø9
A+60
A-40
69 46
.5
R4
A-54
B-121
R6
.5
22
50
80
20
Usable area Ø9
35
Unless otherwise specified, all dimensions are in mm.
29
E SERIES
WALL-MOUNTED ENCLOSURES
Distribution Boards
30
E-Kabin E Series
Distribution Boards
E-Kabin E Series, distribution boards are especially designed Type of Mounting : Stand Alone & Wall-Mounted /
for indoor electrical installation applications of buildings such Wall-Mounted
as shopping malls, hotels, hospitals etc. Their design is suitable Modularity : Monoblock
for installation of DIN-rail type devices. With their monoblock Application : Indoor
body structure they can ensure IP 55 protection degree. The Protection Class : IP 55
body is made of pre-galvanized steel sheet with epoxy polyester Paint : Epoxy-Polyester Powder Paint
powder paint applied. Colour : Standard RAL 7035 (Grey Colour)
Environmental Class : According to EN 60721 - 3 - 3 IE32
Standards : IEC 61439-1, IEC 62208
IEC 60529, IEC 62262
31
Features
Glazed door application Deep gap between door and cover plate
Tempered glass door can be selected optionally. 100 mm gap between the door and the cover plate allows
the installation of accessories such as measuring devices,
signal lamps, etc. on the door.
100
16.5
121
150
32
Hinged cover plates 180° Wide openable door
Cover plates are manufactured as hinged and openable. The door can be opened 180° wide with the standard
Thus, it is possible to intervene without removing the hinge set, thus full access is provided during assembly.
cover plate.
>180°
Easy planning
Thanks to the standard width, 24/36 pieces of 18
mm units width devices can be used on each row.
33
Order Codes
34
Dimensions
B 300 20
C
27
31
A+50
100
16.5
250
124
127
100
50
145
B-92
B C
20 B-40
29.5
B+60
Ø13 Ø9
A+60
A-40
A
34
10
DETAIL A
B-5
Unless otherwise specified, all dimensions are in mm.
35
WALL-MOUNTED
WALL-MOUNTED ENCLOSURES ENCLOSURES ACCESSORIES
36
Internal Mounting Accessories Partial Mounting Plate - EE MP 38
Partial Mounting Plate - EM MP 39
Galvanized Rail Set - EE RSS 40
Aluminum Rail Set - EE RSA 40
Special Mounting Plate - EE TB 41
Front Cover Plates and Accessories Full Height Cover Plate - EM OB 42
Depth Adjustment System - EM DS 42
Cover Plate With Hinges - EG OM 43
Cover Plate Seal Kit - EG OMM 44
Cover Plate Screw Connection Kit - EG OMV 44
Cover Plate Standard Hinge Kit - EG OMT 44
Ventilation Accessories Fan-Filter Unit - EG FAN 45
Filter Unit - EG FIL 45
Spare Filter - EG FS 45
Thermostat - EG ET 46
Fan-Filter Unit With Thermostat - EG FAT 46
Plinth and Cable Entry Accessories Plinth Set - HM BZ 47
Plinth Set - XM BZ 47
Cable Attachment Rail - EE KTP 48
Gland Plate with Brush - EG FR 48
Locks Lock Set - EM KT 49
Wing-Knob Lock Set - HM KT 49
Stainless-Steel Lock Set - XM KT 49
Document Pockets Project Document Pocket - EM SC 50
Project Document Pocket - EE SC 50
Project Document Pocket - EG PC 51
Other Accessories Bracket Set - EO BS 52
Stainless-Steel Bracket Set - XM BS 52
Support Rail - EM KP 53
Support Rail - EE KP 53
180° Opening Hinge - EM TA 54
Wall Mounting Rail - EE DM 54
Cable Duct - EE KB 55
Adjustable Fixing Kit - EE AYT 55
M5x8 Self-Tapping Screw - EG CK 5 56
Snap-on Gasket - EG GC 56
37
Internal Mounting Accessories
Applicable
Product Rated Available Product
Order Codes
Series Height Width
600 EE MP 0560
50
800 EE MP 0580
600 EE MP 1560
150
800 EE MP 1580
600 EE MP 2560
HEIGHT (mm)
250
800 EE MP 2580
600 EE MP 3060
300
800 EE MP 3080
600 EE MP 3560
350
800 EE MP 3580
600 EE MP 4060
400
800 EE MP 4080
38
Partial Mounting Plate - EM MP
It is designed for general usage.
Applicable
Series
39
Internal Mounting Accessories
• Suitable for 600 wide enclosure. 24 MCBs can be used side by side.
Applicable
Series
600 EE RSS 60
Material : Aluminium
Surface : -
Content : 1 piece of aluminum MCB rail
1 piece of Fixing set
Applicable
Series
49
Aluminum rail kit 35
Product Rated Width Order Code
600 EE RSA 60
10
800 EE RSA 80
43
40
Special Mounting Plate - EE TB
It is designed for capacitor mounting in compensation panels or in accordance
with the purpose of partitioning.
Applicable
Series
600 EE TB 60
800 EE TB 80
41
Front Cover Plates and Accessories
• The full height cover plate can be opened 90 degrees in its assembled position.
Applicable
Series
500x400 EM OB 50 40 900x600 EM OB 90 60
600x400 EM OB 60 40 1000x600 EM OB 100 60
600x600 EM OB 60 60 1000x700 EM OB 100 70
700x500 EM OB 70 50 1000x800 EM OB 100 80
800x600 EM OB 80 60 1200x600 EM OB 120 60
800x800 EM OB 80 80 1200x800 EM OB 120 80
Applicable
Series
42
Cover Plate With Hinges - EG OM
It is designed for general use. It has a hinged structure.
Applicable
Series
Product Product
Product Product
Width Width
Rated Order Codes Rated Order Codes
Suitable for Suitable for
Height Height
Mounting Mounting
43
Front Cover Plates and Accessories
Applicable
Series : Used with EG OM.
Applicable
Series : Used with EG OM.
44 44
Ventilation Accessories
Material : Plastic
Surface : RAL 7035 (Grey Colour)
Content : 1 piece of plastic filtered fan
Applicable
Series
Fan-filter unit
Order Product Voltage Frequency Flow Power Noise Level Fan Flow
Code Dimension V Hz A W dBA m3/h
Material : Plastic
Surface : RAL 7035 (Grey Colour)
Content : 1 piece of plastic filtered louvre
Applicable
Series
Filter unit
Product Dimension Protection Class Order code
Spare Filter - EG FS
It is designed to be used as a spare in filtered louvres.
• Washable, • G2 class
Spare Filter (IP44)
Product Dimension Order code
125x125 EG FS 12 44
250x250 EG FS 25 44 Unless otherwise specified, all dimensions are in mm.
45
Ventilation Accessories
Thermostat - EG ET
It is used to control the fans that can be operated in case the temperature
inside the enclosure increases.
Applicable
Series
Thermostat
Order Code EG ET 01
Material : Plastic
Content :
1 piece of Filtered fan with thermostat
Applicable
Series
Note: For fan and filter details, please check product pages with EG FAN and
EG FIL codes.
46
Plinth and Cable Entry Accessories
Plinth Set - HM BZ
It is designed to connect the enclosure to the ground and to arrange the
cable entry-exit.
Applicable
Series
Plinth Set
Enclosure Rated Enclosure Rated Enclosure Rated Enclosure Rated
Order Code Order Code
Width Depth Width Depth
Note: Installation shall be done by the customer by drilling the bottom part of the enclosure.
Plinth Set - XM BZ
It is designed to connect the enclosure to the ground and to arrange the
cable entry-exit.
Applicable
Series
Plinth Set
Enclosure Rated Enclosure Rated
Order Code
Width Depth
300 200 XM BZ 30 20
400 200 XM BZ 40 20
500 200 XM BZ 50 20
500 300 XM BZ 50 30
600 200 XM BZ 60 20
600 300 XM BZ 60 30
800 200 XM BZ 80 20
800 300 XM BZ 80 30
Note: Installation shall be done by the customer by drilling the bottom part of the enclosure.
47
Plinth and Cable Entry Accessories
Applicable
Series
600 EE KTP 60
800 EE KTP 80
Applicable
Series
400 300 EG FR 40
600 500 EG FR 60
Note: In case of using a gland plate with brush, the IP protection level of the
enclosure will decrease to IP 00.
48
Locks
Lock Set - EM KT
It is suitable for the lock recess on the door.
Material : Zamak
Surface : Black colour
Content : 1 piece of Black colour wing-knob lock
(Eurokey 333)
Applicable
Series
Wing-knob lock set
Order Code HM KT
Material : Stainless-steel
Content : 1 piece of ø3 mm Double bit lock
Applicable
Series
Stainless-Steel lock
Stainless-Steel Grade Order Code
304 XM KT 12
316 XM KT 13
49
Document Pockets
400 EM SC 40
500 EM SC 50
600 EM SC 60
700 EM SC 70
800 EM SC 80
600 EE SC 60
800 EE SC 80
50
Project Document Pocket - EG PC
It has the feature of sticking with self-adhesive double-sided tape suitable for 241
Material : Plastic
Surface : Black colour
Content : 1 piece of Plastic document pocket
234
Applicable
Series
257 31
51 51
Other Accessories
Bracket Set - EO BS
It is designed for easy and quick mounting of the enclosure to the wall.
Applicable
Series
,5
R4
8
Bracket set
R6
,5
EO BS
23
Order Code
76
51
20
Ø9
35
Applicable
Series
,5
R4
Order Code XM BS R6
,5
22
80
50
20
Ø9
35
52
Support Rail - EM KP
It is designed to organize the cables inside the door. It is selected according to
the door width.
Applicable
Series
Support rail
Enclosure Rated Width Order Code
300 EM KP 30
350 EM KP 35
400 EM KP 40
500 EM KP 50
600 EM KP 60
700 EM KP 70
800 EM KP 80
Support Rail - EE KP
It is designed to organize the cables inside the door. It is selected according to
the door width.
Applicable
Series
Support rail
Enclosure Rated Width Order code
600 EE KP 60
800 EE KP 80
53
Other Accessories
Material : Zamak
Content : EM TA 180° hinge
Applicable
Series
<700 2 EM TA 2M
≥700 3 EM TA 3M
Applicable
Series
500 EE DM 050
650 EE DM 065
800 EE DM 080
950 EE DM 095
1100 EE DM 110
1250 EE DM 125
54
Cable Duct - EE KB
It is designed for the visual arrangement of the cable outgoing area.
Applicable
Series
Cable duct
Enclosure Rated Width Order Code
600 EE KB 060
800 EE KB 080
Applicable
Series
55
Other Accessories
Material : Steel
Surface : Galvanized coating
Content : 100 pieces of M5x8 self-tapping screw
Applicable
Series
Snap-On Gasket - EG GC
It is designed to prevent damages from sharp surfaces.
15
Material : PVC
15 10
Surface : Black colour
Content : Shown as in the table below.
10
Applicable
Series 6.9
EG GC 01
9.4
5.3
Snap-on gasket 2
Sheet
Content Wire-Reinforced Order Code
Range
2
0.5
EG GC 02
56
57
TERMINAL BOXES T SERIES
58
E-Kabin T Series
Terminal Boxes
E-Kabin T Series terminal boxes are designed as general purpose Type of Mounting : Wall-Mounted
electrical equipment enclosures for indoor applications. They Modularity : Monoblock
have monoblock body structure and provide IP66 protection Application : Indoor
degree. The body and door are made of pre-galvanized sheet Protection Class : IP 66
steel and painted with epoxy polyester powder coating. Paint : Epoxy - polyester powder paint
Colour : Standard RAL 7035 (Grey Colour)
Environmental Class : According to EN 60721 - 3 - 3 IE32
Standards : IEC 62208, IEC 60529,
IEC 62262
59
Features
Quarter-turn lock
With the quarter-turn lock, the door can be opened and
closed easily.
60
Wide access to box
The design of the box opening prevents installation space
losses and provides ease of access and installation inside
the box.
61
Order Codes
Dimensions
,5
R4
B-40
B+60
8
Ø13 Ø9 R6
,5
A+60
23
76
51
A-40
20
Ø9
35
Unless otherwise specified, all dimensions are in mm.
62
Accessories
Bracket Set - EO BS
It allows the box to be mounted on the wall easily and quickly.
Applicable
Series
Bracket set
Order Code EO BS
63
XT SERIES
TERMINAL BOXES Stainless-Steel
64
E-Kabin XT Series
Stainless-Steel Terminal Boxes
E-Kabin XT Series terminal boxes are designed as general Type of Mounting : Wall-Mounted
purpose electrical equipment enclosures for indoor and outdoor Modularity : Monoblock
applications. They have monoblock body structure and provide Application : Indoor
IP66 protection degree. Standard production does not include Protection Class : IP 66
painting process. However, custom-made production, varnished Environmental Class : According to EN 60721 - 3 - 3 IE33
or painted in the desired RAL code is possible. Standards : IEC 62208, IEC 60529,
IEC 62262
XT series stainless-steel terminal boxes can be produced with Material : AISI 304 or 316 grade
AISI 304 or 316 grade raw materials as standard. While keeping stainless-steel - standard
standard product design unchanged, size modification, material
thickness modification and cut-outs can be applied if requested.
65
Features
Quarter-turn lock
With quarter-turn locks, the door can be opened and
closed easily.
66
Practical mounting plate
Design of the mounting plate allows to evaluate the
usable space inside the box with minimum loss.
67
Order Codes
Dimensions
B-40 .5
R4
B+60
Ø13 Ø9
A+60
R6
.5
A-40
22
50
80
20
Ø9
35
Unless otherwise specified, all dimensions are in mm.
68
Accessories
Applicable
Series
69
K SERIES and
CONSOLES Accessories
70
E-Kabin K Series
Monoblock Console
E-Kabin K Series monoblock consoles are designed as general Type of Mounting : Floor-standing
purpose electrical equipment enclosures for indoor applications. Modularity : Monoblock
They have monoblock body structure and provide IP55 Application : Indoor
protection degree. The body and door are made of Protection Class : IP 55
pre-galvanized sheet steel and painted with epoxy polyester Paint : Epoxy - polyester powder paint
powder coating. Colour : Standard RAL 7035 (Grey Colour)
Environmental Class : According to EN 60721 - 3 - 3 IE32
Standards : IEC 61439-1, IEC 62208
IEC 60529, IEC 62262
71
Features
additional rails
In standard supply content there are two in-door support rails included.
72
Back-to-back, double mounting plate
possibility
Using of second mounting plate at rear is possible.
The second mounting plate must be ordered separately as
an accessory.
73
Order Codes
Console Rated
Order Codes
Width (B)
600 EK 0604
800 EK 0804
1000 EK 1004
1200 EK 1204
Dimensions
520
B-10
Front cover
16
1025
698
530
B-7
B-110
100
B 400
Top cover
Overlapping Front Cover
B-110
410
530
530
A C
B-10
74
Accessories
Mounting Plate - EK MK
The second mounting plate can be selected according to the
console width, if desired.
Applicable
Series
Mounting plate
Console Width Order Code
600 EK MK 06
800 EK MK 08
1000 EK MK 10
1200 EK MK 12
Mounting Profile - EG MA
It is designed for cable arrangement inside the door. It is selected according
to the door width.
Applicable
Series
Mounting rail
Console Width Order Code
600 EG MA 0450
800 EG MA 0650
1000 EG MA 0850
1200 EG MA 1050
75
Ventilation Accessories
Material : Plastic
Surface : RAL 7035 (Grey Colour)
Content : 1 piece of plastic filtered fan
Applicable
Series
Fan-filter unit
Order Product Voltage Frequency Flow Power Noise Level Fan Flow
Code Dimension V Hz A W dBA m3/h
Material : Plastic
Surface : RAL 7035 (Grey Colour)
Content : 1 piece of plastic filtered louvre
Applicable
Series
Filter unit
Product Dimension Protection Class Order code
Spare Filter - EG FS
It is designed to be used as a spare in filtered louvres.
• Washable, • G2 class
Spare Filter (IP44)
Product Dimension Order code
125x125 EG FS 12 44
250x250 EG FS 25 44
76
Ventilation Accessories
Thermostat - EG ET
It is used to control the fans that can be operated in case the temperature
inside the enclosure increases.
Applicable
Series
Thermostat
Order Code EG ET 01
Applicable
Series
Note: For fan and filter details, please check product pages with EG FAN and
EG FIL codes.
Fan-filter unit with thermostat
Order Code EG FAT 12
EG FAT 25
77
Other Accessories
Material : Steel
Surface : Galvanized coating
Content : 100 pieces of M5x8 self-tapping screw
Applicable
Series
Snap-On Gasket - EG GC
It is designed to prevent damages from sharp surfaces.
15
Material : PVC
15 10
Surface : Black colour
Content : Shown as in the table below.
10
Applicable
Series 6.9
EG GC 01
9.4
5.3
Snap-on gasket 2
Sheet
Content Wire-Reinforced Order Code
Range
2
0.5
EG GC 02
78
Project Document Pocket - EG PC
It has the feature of sticking with self-adhesive double-sided tape suitable for 241
Material : Plastic
Surface : Black colour
Content : 1 piece of Plastic document pocket
234
Applicable
Series
257 31
79
FLOOR-STANDING ENCLOSURES
Floor-Standing Enclosures
ES ED EL
80
Outdoor Floor-Standing Stainless Steel Floor Standing
Enclosures Enclosures
Painted with high corrosion resistance paint AISI 304 or AISI 316 Stainless-Steel
HS HF XS XH
Galvanized + Painted
Galvanized+Painted Stainless-steel Stainless-steel
(Welded)
Only full height door Only full height door Only full height door Only full height door
81
FLOOR-STANDING ENCLOSURES S SERIES
82
E-Kabin S Series
Electrical Enclosures
83
Features
Aesthetical outlook
Front bar, made of anodized aluminium, provides
aesthetical outlook.
84
Doors with ventilation louvres
Doors with ventilation louvres that can be used in various
applications can be selected as standard.
IP 55 IP 41 IP 41 IP 55 IP 41
85
Features
86
Stackable plinth
Thanks to its modular plinth structure, plints can be
mounted on top of each other to increase the enclosure
height.
87
Enclosure
Module Set - ES MS
It includes horizontal rails, top cover and plinth set to form the framework
structure.
Applicable
Series
88
Uprights Set - ES DP
It is used vertically to form the enclosure framework.
Applicable
Series
Uprights set
Enclosure Rated Height Order Codes
1800 ES DP 18
2000 ES DP 20
2200 ES DP 22
Applicable
Series
Intermediary upright
Enclosure Rated Height Order Codes
1800 ES DO 18
2000 ES DO 20
2200 ES DO 22
89
Enclosure
Front Door - ES OK
D0
D1
D3
C0 Material : Galvanized steel sheet
C1 Surface : Painted, RAL 7035 (Grey Colour)
Content : 1 piece of Front door
1 piece of Front bar
1 piece of Lock
1 piece of Fittings set
Applicable
Series
Front door
Enclosure Rated Enclosure Rated Width
Order Codes
Height or Depth
400 ES OK 1804 D0
500 ES OK 1805 D0
600 ES OK 1806 D0
1800 700 ES OK 1807 D0
800 ES OK 1808 D0
500+500 ES OK 1855 D0
600+600 ES OK 1866 D0
400 ES OK 2004 D0
500 ES OK 2005 D0
600 ES OK 2006 D0
2000 700 ES OK 2007 D0
800 ES OK 2008 D0
500+500 ES OK 2055 D0
600+600 ES OK 2066 D0
400 ES OK 2204 D0
500 ES OK 2205 D0
600 ES OK 2206 D0
2200 700 ES OK 2207 D0
800 ES OK 2208 D0
500+500 ES OK 2255 D0
600+600 ES OK 2266 D0
Note: Given codes are for D0 door types. If D1, D3, C0 or C1 type door is prefered last two digits of
the code must be changed accordingly.
For C0-C1 type of doors, temperred glass is used.
50 cm 34,5 cm EG MA 0350
60 cm 44,5 cm EG MA 0450
70 cm 54,5 cm EG MA 0550
80 cm 64,5 cm EG MA 0650
90
Fixed Panel - EG SK
It is used to close the rear and/or sides of the panels. The design of the rear
and side fixed panels are the same.
Applicable
Series
SK Fixed panel
Enclosure Rated Enclosure Rated Width
Order Codes
Height or Depth
400 EG SK 1804
500 EG SK 1805
1800 600 EG SK 1806
700 EG SK 1807
800 EG SK 1808
400 EG SK 2004
500 EG SK 2005
2000 600 EG SK 2006
700 EG SK 2007
800 EG SK 2008
400 EG SK 2204
500 EG SK 2205
2200 600 EG SK 2206
700 EG SK 2207
800 EG SK 2208
91
Enclosure
Partial Door - ES PK
It is designed to use for horizontal partitioning for power distribution applications.
Applicable
Series
Note: When using partial doors, Front Bars have to be ordered additionally.
The sum of partial doors’ rated heights used in an enclosure has to be 10 cm less than enclosure rated
height.
Partial door
Partial
Enclosure
Door
Rated
Rated
Width
Height
ES PK 1408
ES DP 22
Example Application
Unless otherwise specified, all dimensions are in mm.
92
Horizontal Divider Rail - ES YA
It is designed to use for horizontal partitioning for power distribution
applications. It shall be used between two partial doors.
400 ES YA 04
500 ES YA 05
600 ES YA 06
700 ES YA 07
800 ES YA 08
Material : Aluminium
Surface : Anodized coating
Content : 1 piece of Front bar
1 piece of Fittings set
Applicable
Series
Front bar
Enclosure Rated Width Order code
400 ES OET 04
500 ES OET 05
600 ES OET 06
700 ES OET 07
800 ES OET 08
93
Mounting Plate
Applicable
Series
HH WW DD TXX
12* 04 04 T15
14* 05 05 T20
16* 06 06 T30
18 07 07
20 08 08
22 10
12
Net
Net
Height Dimension Width
h1
Dimension g1
h1
Full height mounting plates can be fixed on rear uprights. If full height mounting plate is required
to be adjustable through the depth, EG MKT Sliding rail accessories must be used. Sliding rail
accessories must be ordered separately.
94
Full Height Mounting Plate Application Examples
EG MKT EG MKT
EG MC Full Height EG MC
166
EG MKI
3 mm
Inner support rail EG MKI is providing
additional strength for fixing heavy equipment
on full height mounting plates. Full height
mounting plate is fixed after EG MKI is
positioned and fixed, so that it’s rear surface
rests on EG MKI’s front surface.
17 mm
06
49
49
A 08 06
08
A Detail
1851
1949
2055
1851
1949
2055
A1
A2
A3
100
100
Ø13mm
Net Enclosure Rated Height
Dimensions 1800 2000 2200
B Detail
B1
B
08
503
90
B3
96
Example: ES OK 2008 D0
D0 D0 type front door usable space
height dimensions (A4)
Dimension / A4 ES OK 18 ES OK 20 ES OK 22
D1 Example: ES OK 2008 D1
Example: ES OK 2008 D3
D3
97
FLOOR-STANDING ENCLOSURES D SERIES
98
E-Kabin D Series
Electrical enclosures
99
Features
Stackable plinth
Thanks to its modular plinth structure, plints can be
mounted on top of each other to increase the enclosure
height.
100
Robust framework
Its strong framework structure allows doors and covers to
be fixed after electro-assembly.
IP 55 IP 41 IP 41 IP 55 IP 41
101
Enclosure
Module Set - ED MS
It includes horizontal rails, top cover and plinth set to form the framework.
Note: Supply contents include bottom plate when IP 55 protection class is selected and last two digits of
the order code is “55”. Example: ED MS 0506 55
(For Bottom Plate combinations please check page 182)
Supply contents do not include bottom plate when IP 41 protection class is selected.
Example:ED MS 0506 41
102
Uprights Set - ED DP
It is used vertically to form the enclosure framework.
Uprights set
Enclosure Rated Height Order Code
1800 ED DP 18
2000 ED DP 20
2200 ED DP 22
Applicable
Series
1800 ED DO 18
2000 ED DO 20
2200 ED DO 22
103
Enclosure
Front Door - ED OK
D0
D1
D3
C0
Material : Galvanized steel sheet
C1
Surface : Painted, RAL 7035 (Grey Colour)
Content : 1 piece of Front door
1 piece of Lock
1 piece of Fittings set
Applicable
Series
Front door
Enclosure Rated Panel Rated Width
Order Codes
Height or Depth
400 ED OK 1804 D0
500 ED OK 1805 D0
600 ED OK 1806 D0
1800 700 ED OK 1807 D0
800 ED OK 1808 D0
500+500 ED OK 1855 D0
600+600 ED OK 1866 D0
400 ED OK 2004 D0
500 ED OK 2005 D0
600 ED OK 2006 D0
2000 700 ED OK 2007 D0
800 ED OK 2008 D0
500+500 ED OK 2055 D0
600+600 ED OK 2066 D0
400 ED OK 2204 D0
500 ED OK 2205 D0
600 ED OK 2206 D0
2200 700 ED OK 2207 D0
800 ED OK 2208 D0
500+500 ED OK 2255 D0
600+600 ED OK 2266 D0
Note: Given codes are for D0 door types. If D1, D3, C0 or C1 type door is prefered last two digits of
the code must be changed accordingly.
For C0-C1 type of doors, temperred glass is used.
50 cm 34,5 cm EG MA 0350
60 cm 44,5 cm EG MA 0450
70 cm 54,5 cm EG MA 0550
80 cm 64,5 cm EG MA 0650
104
Fixed Panel - EG SK
It is used to close the rear and/or sides of enclosures. The design of the rear
and side fixed panels are the same.
Applicable
Series
Fixed panel
Enclosure Rated Enclosure Nominal Width
Order Code
Height or Depth
400 EG SK 1804
500 EG SK 1805
1800 600 EG SK 1806
700 EG SK 1807
800 EG SK 1808
400 EG SK 2004
500 EG SK 2005
2000 600 EG SK 2006
700 EG SK 2007
800 EG SK 2008
400 EG SK 2204
500 EG SK 2205
2200 600 EG SK 2206
700 EG SK 2207
800 EG SK 2208
105
Mounting Plate
Applicable
Series
HH WW DD TXX
12* 04 04 T15
14* 05 05 T20
16* 06 06 T30
18 07 07
20 08 08
22 10
12
Net
Net
Height Dimension Width
h1
Dimension g1
h1
Full height mounting plates can be fixed on rear uprights. If full height mounting plate is required
to be adjustable through the depth, EG MKT Sliding rail accessories must be used. Sliding rail
accessories must be ordered separately.
106
Full Height Mounting Plate Application Examples
EG MKT EG MKT
EG MC Full Height EG MC
166
EG MKI
3 mm
Inner support rail EG MKI is providing
additional strength for fixing heavy equipment
on full height mounting plates. Full height
mounting plate is fixed after EG MKI is
positioned and fixed, so that it’s rear surface
rests on EG MKI’s front surface.
17 mm
06
49
49
A
08 800 600
A Detail
1851
1949
2055
1851
1949
2055
A1
A2
A3
100
100
Ø13mm
Net Enclosure Rated Height
Dimensions 1800 2000 2200
B Detail
B1
B
08
503
90
B3
108
D0
D0 type front door usable space Example: ED OK 2008 D0
height dimensions (A4)
Dimension / A4 ED OK 18 ED OK 20 ED OK 22
D1
Example: ED OK 2008 D1
D3
Example: ED OK 2008 D3
109
FLOOR-STANDING ENCLOSURES L SERIES
110
E-Kabin L Series
Electrical Enclosures
111
Features
112
Polyurethane sealing gasket
Foam-in-place gasket applied to door does not
loose its elasticity in time and provides protection
against dust and water.
113
Enclosure
Module Set - EL MS
Supply contents include horizontal rails, top cover and bottom plate.
≥600
≤500
96
114
Uprights Set - EL DP
EL DP is used vertical wise to assemble the enclosure framework.
Uprights set
Enclosure Rated Height Order Code
1800 EL DP 18
2000 EL DP 20
115
Enclosure
Applicable
Series
400 EL OA 1804
500 EL OA 1805
600 EL OA 1806
1800 700 EL OA 1807
800 EL OA 1808
500+500 EL OA 1855
600+600 EL OA 1866
400 EL OA 2004
500 EL OA 2005
600 EL OA 2006
2000 700 EL OA 2007
800 EL OA 2008
500+500 EL OA 2055
600+600 EL OA 2066
Note: There are 2 pieces of rear Fixed Panels and 1 piece of EL DO Vertical
Intermediary Rail in the standard order content for overlapping doors.
50 cm 34,5 cm EG MA 0350
60 cm 44,5 cm EG MA 0450
70 cm 54,5 cm EG MA 0550
80 cm 64,5 cm EG MA 0650
116
Side Fixed Panel Set - EL YS
It is used to close sides of enclosures. The design of the rear and side fixed
panels are the same.
Applicable
Series
400 EL YS 1804
500 EL YS 1805
1800 600 EL YS 1806
700 EL YS 1807
800 EL YS 1808
400 EL YS 2004
500 EL YS 2005
2000 600 EL YS 2006
700 EL YS 2007
800 EL YS 2008
117
Mounting Plate
Applicable
Series
HH WW DD TXX
12* 04 04 T15
14* 05 05 T20
16* 06 06 T30
18 07 07
20 08 08
22 10
12
Net
Net
Height Dimension Width
h1
Dimension g1
h1
Full height mounting plates can be fixed on rear uprights. If full height mounting plate is required
to be adjustable through the depth, EG MKT Sliding rail accessories must be used. Sliding rail
accessories must be ordered separately.
118
Full Height Mounting Plate Application Examples
EG MKT EG MKT
EG MC Full Height EG MC
166
EG MKI
3 mm
Inner support rail EG MKI is providing
additional strength for fixing heavy equipment
on full height mounting plates. Full height
mounting plate is fixed after EG MKI is
positioned and fixed, so that it’s rear surface
rests on EG MKI’s front surface.
17 mm
06
49
49
A
08 800 600
Detail A
1851
1949
2055
1851
1949
2055
A1
A2
A3
100
100
Ø13mm
Net Enclosure Rated Height
Dimensions 2000
A1 1851 mm
A2 1949 mm B2
A3 2055 mm
Detail B
B
08
B1
503
90
B3
120
121
HS SERIES
FLOOR-STANDING ENCLOSURES Outdoor- Modular
122
E-Kabin HS Series
Outdoor Electrical Enclosures
123
Features
Moreover;
• Rear and front door usage
• It is possible to change the door opening direction.
124
Lifting kit
The lifting kit is placed on the top of the canopy as
standard. By the lifting kit, it is available to lift up and
carry the fully loaded enclosure safely and easily.
Stackable plinth
Thanks to its modular plinth structure, plints can be
mounted on top of each other to increase the enclosure
height.
125
Order Codes
HS outdoor free standing enclosures are manufactured in the dimensions given below.
Please consult your Customer Represantative for order information.
Dimensions
C + 115
B
A
Enclosure Rated C Dimensiom Body D Dimension Enclosure Width
Width Width Side Panels Included (C+50 mm)
C
04-400 mm 400 450
D
05-500 mm 500 550
06-600 mm 600 650
08-800 mm 800 850 F + 115
F
08-800 mm 800 855 G
126
C + 57 H + 57 K + 115
32
Ø
28
55
B
A
100
C F G K
D H L
30 30
32
B
B
A
A
G K F K
H L
Enclosure Rated A Dimension Body B Dimension External Enclosure Rated K Dimension Body L Dimension Enclosure Depth Front and
Height Height Height (A+180 mm) Depth Depth Rear Panels Included (K+55 mm)
Enclosure Rated C Dimension Body D Dimension Enclosure Width F Dimension G Dimension H Dimension Enclosure Width
Width Width Side Panels are included(C+25 mm) Body Width Body Width Side Panels Included(W+25 mm)
127
HF SERIES
FLOOR-STANDING ENCLOSURES Outdoor- Monoblock
128
E-Kabin HF Series
Outdor Electrical Enclosures
129
Features
130
Lifting kit
The lifting kit is placed on the top of the canopy as standard.
By the lifting kit, it is available to lift up and carry the fully
loaded enclosure safely and easily.
Stackable plinth
Thanks to its modular plinth structure, plints can be
mounted on top of each other to increase the enclosure
height.
131
Order Codes
600 05 HF 16 06 05
16
800 05 HF 16 08 05
600 05 HF 20 06 05
20
800 05 HF 20 08 05
Dimensions
A
Width Depth
132
Mounting Plates and Accessories
Applicable
Series
600 HF MK 1606
1600
800 HF MK 1608
600 HF MK 2006
2000
800 HF MK 2008
133
XS SERIES
FLOOR-STANDING ENCLOSURES Stainless-Steel - Modular
134
E-Kabin XS Series
Stainless-Steel Electrical Enclosures
E-Kabin XS Series stainless-steel, floor standing enclosures are Type of Mounting : Floor-Standing
designed as general purpose electrical equipment enclosures for Modularity : Modular
industrial applications. They are suitable for indoor applications Application : Indoor
and have modular structure, which enables expansion by Protection Class : IP55
combining side by side. They provide IP 55 protection degree. Environmental Class : According to EN 60721 - 3 - 3 IE33
Standard production does not include painting process. Standards : IEC 61439-1
However, custom-made production, varnished or painted in the IEC 62208
desired RAL code is possible. IEC 60529
IEC 62262
XS Series stainless-steel enclosures can be produced with AISI Material : AISI 304 grade stainless-steel -
304 or 316 grade raw material. In standard swinghandle lock standard
made of metal with high chemical resistance is used in XS AISI 316 grade stainless-steel -
Series. Optionally, locking system made of 304 or 316 grade optional
stainless-steel can also be selected.
135
Features
Stackable plinth
Thanks to its modular plinth structure, plints can be
mounted on top of each other to increase the enclosure
height.
136
Polyurethane sealing gasket
Foam-in-place gasket behind the door does not lose its
elasticity in time and provides protection against dust and
water
a'= a+n.200 mm
b'= b+n.100 mm
c’= c+n.100 mm
137
Order Codes
XS Stainless-Steel floor standing enclosures are manufactured in the dimensions given below.
Please consult your Customer Represantative for order information.
138
Dimensions
49
49
1851
1949
2055
1851
1949
2055
H1
H2
H3
100
100
08
B3
Dimensions / HK ES OK 18 ES OK 20 ES OK 22
75 80
139
XH SERIES
FLOOR-STANDING ENCLOSURES Stainless-Steel - Monoblock
140
E-Kabin XH Series
Stainless-Steel Electrical Enclosures
E-Kabin XH Series stainless-steel, floor standing enclosures are Type of Mounting : Floor-Standing
designed as general purpose electrical equipment enclosures Modularity : Modular
for outdoor applications. Their structure is modular, which Application : Outdoor
enables expansion by combining side by side. They provide IP Protection Class : IP55
55 protection degree. Standard production does not include Environmental Class : According to EN 60721 - 3 - 3 IE37
painting process. However, custom-made production, varnished Standards : IEC 61439-1
or painted in the desired RAL code is possible. IEC 62208
IEC 60529
XS Series stainless-steel enclosures can be produced with AISI IEC 62262
304 or 316 grade raw material. Standard swinghandle lock is Material : AISI 304 grade stainless-steel -
made of 316 grade stainless-steel. standard
AISI 316 grade stainless-steel -
All E-Kabin interior accessories are designed to be suitable for optional
use in stainless-steel enclosures as well. Lock set : Stainless-steel - standard
141
Features
a'= a+n.200 mm
b'= b+n.100 mm
c’= c+n.100 mm
142
Modular design - side-by-side
expandability
Thanks to its modular structure, it is possible to assemble
and expand it side by side for multiple combinations.
Moreover;
• Rear and front door use
• It is possible to change the door opening direction.
143
Order Codes
XH Stainless-Steel floor standing enclosures are manufactured in the dimensions given below.
Please consult your Customer Represantative for order information.
Dimensions
B
A
144
Dimensions
C + 57 H + 57 K + 115
32
Ø
28
55
B
A
100
C F G K
D H L
30 30
32
B
B
A
A
G K F K
H L
Enclosure Rated A Dimension Body B Dimension Outer Height Enclosure Rated K Dimension Body L Dimension Enclosure Depth
Height Height (A+180mm) Depth Depth Front - Back Cover Included (K+55 mm)
Enclosure Rated C Dimension Body D Dimension Enclosure Width F Dimension Body G Dimension H Dimension Enclosure Width
Width Width Including Side Cover (C+25 mm) Width Body Widthi Including Side Cover (W+25 mm)
145
Floor-Standing Enclosure
FLOOR-STANDING ENCLOSURES Accessories
146
Full Height Mounting Plates and Full Height Mounting Plates - EG MK 148
Accessories Full Height Mounting Plate Upper-Lower Support Rail - EG MKT 150
Full Height Mounting Plate Inner Support Rail - EG MKI 151
Full Height Mounting Plate Infill Rail - EG MKA 151
Internal Mounting Accessories Mounting Rail - EG MA 154
Mounting Rail - EG MB 155
Mounting Rail - EG MC 156
Mounting Rail - EG ME 157
Mounting Rail - EG MG 157
Mounting Plate - EG MP 158
Special Mounting Rail - EG SP 159
Power Factor Compensation Mounting Plate - EG KSS 160
Power Factor Compensation Mounting Plate (Deep Type) - EG KSD 161
Aluminium Rail Set - EG RS 162
MCCB Adjustable Mounting Plates - EG SY 163
Special Fixing Set - EG DST 164
19 inch Swing Frame - EG MF 165
Adapter Rail - HF AO 166
Front Cover Plates and Accessories Front Cover Frame Set - HS OS 167
Front Cover Frame Set - HF OS 167
Full Height Cover Plate - EG OB 168
Full Height Cover Plate - HS OB 169
Cover Plate With Hinges - EG OM 170
Front Cover Frame Set - EG OS 171
Fixed Cover Plate - EG SO 172
Cover Plate Standard Latch Set - EG OMP 173
Cover Plate Standard Hinge Kit - EG OMT 173
Cover Plate Seal Kit - EG OMM 174
Cover Plate Screw Connection Kit - EG OMV 174
Ventilation Accessories Ventilation Module - EG HM 175
Roof Top Fan - EG FM 176
Under-Canopy Ventilation Set - HS FM 177
Under-Canopy Ventilation Set - HF FM 177
Fan-Filter Unit - EG FAN 178
Filter Unit - EG FIL 178
Spare Filter - EG FS 178
Thermostat - EG ET 179
Fan-Filter Unit With Thermostat - EG FAT 179
Base and Cable Entry Accessories Plinth Set - EG BZ 180
Plinth Set - XS BZ 181
Bottom Gland Plate Set - ES BO 182
Cable Attachment Rail - EG KTP 183
Brush for Bottom Cable Entry - EG OF 183
Bottom Plate Gasket Set - EG BOC 184
Gland Plate With Brush - EG FR 184
Locks XS KT 01 Stainless-Steel Swinghandle Lock - XS KT 185
XS KT 02 Stainless-Steel Padlockable Swinghandle Lock - XS KT 185
ES KT 01 Swinghandle Lock With Button - ES KT 186
EG KT 01 Swinghandle Lock - EG KT 186
Enclosure Baying Accessories Enclosure Baying Kit - EG PB 00 187
Enclosure Baying Kit - EG PB 03 187
Document Pockets Project Document Pocket - EG PC 188
Project Document Pocket - EG SC 188
Door Holders Door Holder Set - HF KS 189
Door Holder Set - EG DT 189
Lifting Accessories Lifting Kit - EG AT 01 190
Dual Lifting Kit - EG AT 02 190
Ventilation Module Lifting Kit - EG HMT 01 191
Ventilation Module Dual Lifting Kit - EG HMT 02 191
Other Accessories Spring Zamak Nut - EG CY 192
Zamak Nut - EG CZ 192
M5x8 mm Self-Tapping Screw - EG CK 5 193
Snap-On Gasket - EG GC 193
Interior Lighting Fixture - EG KL 194
EG MB Fixing Set - EG MBT 194
Busbar Riser Module - EG BY 195
Wall Fixing Set - ES DS 196
Laptop Table - EG DB 196
Corner Module - EG KM 197
Screen Module - EG MR 197
147
Mounting Plate
Applicable
Series
HH WW DD TXX
12* 04 04 T15
14* 05 05 T20
16* 06 06 T30
18 07 07
20 08 08
22 10
12
Net
Net
Height Dimension Width
h1
Dimension g1
h1
Full height mounting plates can be fixed on rear uprights. If full height mounting plate is required
to be adjustable through the depth, EG MKT Sliding rail accessories must be used. Sliding rail
accessories must be ordered separately.
148
Full Height Mounting Plate Application Examples
EG MKT EG MKT
EG MC Full Height EG MC
166
EG MKI
3 mm
Inner support rail EG MKI is providing
additional strength for fixing heavy equipment
on full height mounting plates. Full height
mounting plate is fixed after EG MKI is
positioned and fixed, so that it’s rear surface
rests on EG MKI’s front surface.
Standard Type
Applicable
Series
400 EG MKT 04
500 EG MKT 05
600 EG MKT 06
700 EG MKT 07
800 EG MKT 08
1000 EG MKT 10
1200 EG MKT 12
Overlapping Type
Standard Type
Overlapping Type
150
Full Height Mounting Plate Inner
Support Rail - EG MKI
Designed as support rail in case of mounting heavy equipment on Full Height
Mounting Plate to be positioned at inner side.
800 EG MKI 08
1000 EG MKI 10
1200 EG MKI 12
Applicable
Series
14 EG MKA 14
16 EG MKA 16
18 EG MKA 18
20 EG MKA 20
22 EG MKA 22
151
Internal Mounting Accessories
EG MA
EG MB
EG ME
EG MC
EG MP 05
EG MP 10
EG MP
EG MP 15
EG MP 20
EG MP
EG MP
152
EG DST 200
EG MG EG DST 100
EG RS
EG KSS / EG KSD
EG SY
EG MP
EG SP
153
Internal Mounting Accessories
Mounting Rail - EG MA
It is designed for general use.
O
M
E
BL
LA
AI
AV
24 Applicable
Series
19
Mounting rail
154
Mounting Rail - EG MB
It is designed for general use.
TH
G
N
LE
2 pieces of EG MB Fixing bracket
G
N
TI
N
U
4 pieces of M5x8 Self-tapping screw
O
M
E
BL
LA
AI
AV
Applicable
49
Series
23
2
Mounting rail
155
Internal Mounting Accessories
Mounting Rail - EG MC
It is designed for general use.
LA
AI
AV
Applicable
Series
2
23
49
Mounting rail
156
Mounting Rail - EG ME
It is designed to be used in the depth of the panel, suitable for general use.
Applicable
Series
100
24
Mounting rail
Enclosure rated depth Order Code
800 EG ME 0700
900 EG ME 0800
1000 EG ME 0900
1200 EG ME 1100
Mounting Rail - EG MG
It is designed for mounting vertically between horizontal rails.
2
24
49
Mounting rail
Enclosure Rated Height Order Code
1800 EG MG 1650
2000 EG MG 1850
2200 EG MG 2050
157
Internal Mounting Accessories
Mounting Plates - EG MP
It is providing flat mounting surface suitable for general use.
Applicable
Series
50 (500 mm)
60 (550 mm)
Sample Coding: EG MP 05 03
158
Special Mounting Rail - EG SP
It is designed for general use.
TH
G
N
LE
Content : 1 piece of Mounting profile
G
N
TI
N
U
O
1 piece of Fittings set
M
E
BL
LA
AI
AV
Applicable
Series
74
20
Transportation – Loading and Storage Manual
350 EG SP 04
450 EG SP 05
550 EG SP 06
650 EG SP 07
750 EG SP 08
850 EG SP 09
950 EG SP 10
1050 EG SP 11
1150 EG SP 12
159
Internal Mounting Accessories
Applicable
Series
298
231
EG MP 25
500 EG KSS 0705
700 600 EG KSS 0706
700 EG KSS 0707
800 EG KSS 0708
EG MP 05
400 EG KSS 0804
m 500 EG KSS 0805
0m
-10
W idth 800 600 EG KSS 0806
ted
Ra
os ure 700 EG KSS 0807
Encl
800 EG KSS 0808
Application example:
EG MP 05
EG MP 10
m
0m
-10
i dth
dW
ate
eR
osur
Encl
160
Power Factor Compensation Mounting
Plate (Deep Type) - EG KSD
Designed for assembling p.f. compensation equipments. Thanks to its sliding
design it provides ease of assembly and use. Side mounting surfaces are
longer than the standard type, which allow addiditional means for equipment
(e.g. reactors) mounting.
Applicable
Series
298
365
EG MP 20
Application example:
EG MP 25
m
0m
-10
dth
Wi
ted
Ra
os ure
Encl
161
Internal Mounting Accessories
Material : Aluminium
Surface : -
Content : 1 piece of Aluminium rail
2 pieces of Side holders
1 piece of Fixing set
Applicable
Series
04 EG RS 04 246
05 EG RS 05 346
06 EG RS 06 446
07 EG RS 07 546
08 EG RS 08 646
49
10 35
43
162
MCCB Adjustable Mounting Plate - EG SY
It is designed for adjusting the mounting depth of the MCCB.
Applicable
Series
A
MCCB adjustable mounting plate
Dimension A (mm) Dimension B (mm) Order Code
80 150 EG SY 80*150
90 200 EG SY 90*200
105 200 EG SY 105*200
140 200 EG SY 140*200
140 300 EG SY 140*300
190 200 EG SY 190*200
210 300 EG SY 210*300
210 400 EG SY 210*400
280 300 EG SY 280*300
280 400 EG SY 280*400
290 300 EG SY 290*300
163
Internal Mounting Accessories
Applicable
Series
min : 59 mm min : 59 mm
maks : 114 mm maks : 214 mm
EG DST 100
EG DST 100 EG DST 200 EG 100 EG DST 200
164
19 inch Swing Frame - EG MF
It is designed for mounting 19 inch wide devices up to 38U height. It has
hinged structure and integrated lock.
Kullanılabilecek
Seriler
Note: It can be used in enclosures with rated height of 2000 and rated
width of 800 mm.
165
Internal Mounting Accessories
Adapter Rail - HF AO
It is designed to create a mounting surface on the front side of HF series enclosures.
Applicable
Series
Adapter rail
Enclosure
Rated Order Codes
Height
1600 HF AO 16
2000 HF AO 20
166
Front Cover Plates and Accessories
Applicable
Series
Front cover frame set
Enclosure Rated Enclosure Enclosure Rated Enclosure
Order Code Order Code
Height Rated Width Height Rated Width
Applicable
Series
600 HF OS 1606
1600
800 HF OS 1608
600 HF OS 2006
2000
800 HF OS 2008
167
Front Cover Plates and Accessories
Applicable
Series
400 EG OB 1404
500 EG OB 1405
1400 600 EG OB 1406
700 EG OB 1407
800 EG OB 1408
400 EG OB 1604
500 EG OB 1605
1600 600 EG OB 1606
700 EG OB 1607
800 EG OB 1608
400 EG OB 1804
500 EG OB 1805
1800 600 EG OB 1806
700 EG OB 1807
800 EG OB 1808
400 EG OB 2004
500 EG OB 2005
2000 600 EG OB 2006
700 EG OB 2007
800 EG OB 2008
400 EG OB 2204
500 EG OB 2205
2200 600 EG OB 2206
700 EG OB 2207
800 EG OB 2208
168
Full Height Cover Plate - HS OB
It is suitable for general use in floor-standing modular outdoor type enclosures.
It has a hinged structure and two quarter turn locks.
Applicable
Series
400 HS OB 1804
500 HS OB 1805
1800 600 HS OB 1806
700 HS OB 1807
800 HS OB 1808
400 HS OB 2004
500 HS OB 2005
2000 600 HS OB 2006
700 HS OB 2007
800 HS OB 2008
400 HS OB 2204
500 HS OB 2205
2200 600 HS OB 2206
700 HS OB 2207
800 HS OB 2208
169
Front Cover Plates and Accessories
Applicable
Series
Product Product
Product Product
Width Width
Rated Order Codes Rated Order Codes
Suitable for Suitable for
Height Height
Mounting Mounting
170
Front Cover Frame Set - EG OS
It is designed for mounting front cover plates.
Applicable
Series
400 EG OS 1404
500 EG OS 1405
1400 600 EG OS 1406
700 EG OS 1407
800 EG OS 1408
400 EG OS 1604
500 EG OS 1605
1600 600 EG OS 1606
700 EG OS 1607
800 EG OS 1608
400 EG OS 1804
500 EG OS 1805
1800 600 EG OS 1806
700 EG OS 1807
800 EG OS 1808
400 EG OS 2004
500 EG OS 2005
2000 600 EG OS 2006
700 EG OS 2007
800 EG OS 2008
400 EG OS 2204
500 EG OS 2205
2200 600 EG OS 2206
700 EG OS 2207
800 EG OS 2208
171
Front Cover Plates and Accessories
Applicable
Series
300 EG SO 1803
400 EG SO 1804
1800
500 EG SO 1805
600 EG SO 1806
300 EG SO 2003
400 EG SO 2004
2000
500 EG SO 2005
600 EG SO 2006
300 EG SO 2203
400 EG SO 2204
2200
500 EG SO 2205
600 EG SO 2206
172
Cover Plate Standard Latch Set - EG OMP
It is included in standard supply content of cover plates. It is made of
plastic material.
Material : Plastic
Surface : Black colour
Content : 10 pieces of Plastic handles set
Applicable
Series : Can be used with EG OM
Applicable
Series : Can be used with EG OM
173
Front Cover Plates and Accessories
Applicable
Series : Can be used with EG OM
174
Ventilation Accessories
Ventilation Module - EG HM
It is designed to provide natural ventilation for cooling purposes.
Applicable
Series
Ventilation module
175
Ventilation Accessories
• Easy to set-up
• Radial fan with backward blade angle
• Quick and easy assembling feature that does not require bolt connection
Applicable
Series
176
Under-Canopy Ventilation Set - HS FM
It is designed for ventilation under the roof in floor-standing modular
outdoor enclosures.
Applicable
Series
Applicable
Series
177
Ventilation Accessories
Material : Plastic
Surface : RAL 7035 (Grey Colour)
Content : 1 piece of plastic filtered fan
Applicable
Series
Fan-filter unit
Order Product Voltage Frequency Flow Power Noise Level Fan Flow
Code Dimension V Hz A W dBA m3/h
Material : Plastic
Surface : RAL 7035 (Grey Colour)
Content : 1 piece of plastic filtered louvre
Applicable
Series
Filter unit
Product Dimension Protection Class Order code
Spare Filter - EG FS
It is designed to be used as a spare in filtered louvres.
• Washable, • G2 class
Spare Filter (IP44)
Product Dimension Order code
125x125 EG FS 12 44
250x250 EG FS 25 44
178
Thermostat - EG ET
It is used to control the fans that can be operated in case the temperature
inside the enclosure increases.
Applicable
Series
Thermostat
Order Code EG ET 01
Applicable
Series
Note: For fan and filter details, please check product pages with EG FAN and
EG FIL codes.
Fan-filter unit with thermostat
Order Code EG FAT 12
EG FAT 25
179
Base and Cable Entry Accessories
Plinth Set - EG BZ
Mounted under existing plinth of the enclosure, it allows the enclosure to be
raised 100 mm more.
Applicable
Series
Plinth Set
180
Plinth Set - XS BZ
Mounted under existing plinth of the enclosure, it allows the enclosure to be
raised 100 mm more.
Applicable
Series
Plinth Set
181
Base and Cable Entry Accessories
Applicable
Series
182
Cable Attachment Rail - EG KTP
It is designed for attaching cables at incoming inside the enclosure.
Applicable
Series
400 EG KTP 04
500 EG KTP 05
600 EG KTP 06
700 EG KTP 07
800 EG KTP 08
1000 EG KTP 10
1200 EG KTP 12
Material : PVC
Surface : Painted, Black Colour
Content : 2 meters of Brush for bottom cable entry
Applicable
Series
183
Base and Cable Entry Accessories
Material : Polyethylene
Surface : Anthracite colour
Content : 6 meters of 5X15 mm One-sided adhesive tape
5
Applicable
15
Series
Applicable
Series
400 300 EG FR 40
600 500 EG FR 60
Note: In case of using a gland plate with brush, the IP protection level of the
enclosure will decrease to IP 00.
184
Locks
XS KT 01 Stainless-Steel Swinghandle
Lock - XS KT
Lift-turn lock system made of AISI 316 grade stainless-steel
XS KT 02 Stainless-Steel Padlockable
Swinghandle Lock - XS KT
Padlockable lift-turn lock system made of AISI 316 grade stainless-steel
185
Locks
Material : Aluminium
Surface : Black Painted
Content : 1 piece of Swinghandle lock
Applicable
Series
EG KT 01 Swinghandle Lock - EG KT
Standard swinghandle lock with lift-turn feature.
Material : Zamak
Surface : Black Colour
Content : 1 piece of Swinghandle lock
Applicable
Series
EG KT 01 swinghandle lock
Order Code EG KT 01
186
Enclosure Baying
Surface : Galvanized
Content : 10 pieces of Special M6 bolts
10 pieces of M6 Spring zamak nut
6 meters gasket set (IP40 version does not include gasket set)
Applicable
Series
IP40 EG PB 00 IP40
IP55 EG PB 00 IP55
• Installation from inside the enclosure without removing the mounting plate.
• Robust baying at 6 points
Applicable
Series
IP40 EG PB 03 IP40
IP55 EG PB 03 IP55
187
Document Pockets
Applicable
234
Series
257 31
• It can be fixed at the desired height on support rails located inner side of the door.
• Suitable for 75 mm thick folders.
Steel project pocket - ES, ED, EL, XS Steel project pocket - HS, HF
Enclosure rated width Order Code Enclosure rated width Order Code
400 EG SC 04 500 EG SC 04
500 EG SC 05 600 EG SC 05
600 EG SC 06 700 EG SC 06
700 EG SC 07 800 EG SC 07
800 EG SC 08
188
Door Holders
> 90°
Applicable
Series
189
Lifting Accessories
Lifting Kit - EG AT 01
• It is used for lifting enclosures by crane.
Applicable
Series
Lifting kit
Order Code EG AT 01
Applicable
Series
190
Ventilation Module Lifting Kit - EG HMT 01
It is used when lifting enclosures with ventilation module by crane.
Surface : Galvanized
Content : 4 pieces of M12 Lifting eyebolts
4 pieces of Steel shafts
4 pieces of Aluminum rings
Applicable
Series
Surface : Galvanized
Content : 2 pieces of M12 Dual lifting brackets
4 pieces of Steel shafts
4 pieces of Aluminum rings
Applicable
Series
191
Other Accessories
Material : Zamak
Content : 10 pieces of Spring zamak nuts
Applicable
Series
M6 EG CY M6
M8 EG CY M8
Zamak Nut - EG CZ
It is designed for general use.
Material : Zamak
Content : 10 pieces of Zamak nuts
Applicable
Series
Zamak nut
Size Order Code
M6 EG CZ M6
M8 EG CZ M8
192
M5x8 mm Self-Tapping Screw - EG CK 5
Special spiral metric thread structure. It has self-tapping feature for sheet
metal surface.
Material : Steel
Surface : Galvanized coating
Content : 100 pieces of M5x8 mm self-tapping screw
Applicable
Series
Snap-On Gasket - EG GC
It is designed to prevent damages from sharp surfaces.
15
Material : PVC
15 10
Surface : Black colour
Content : Shown as in the table below.
10
Applicable
Series 6.9
EG GC 01
9.4
5.3
Snap-on gasket 2
Sheet
Content Wire-Reinforced Order Code
Range
2
0.5
EG GC 02
193
Other Accessories
Material : Polycarbonate
Content : 1 piece of Indoor lighting fixture
1 piece of Neodymium magnet
2 pieces of M5x12 mm self-tapping screw
Applicable
Series
EG KL 220V AC 25 cm
EG KL 220V AC 50 cm
EG KL 24V DC 25 cm
EG KL 24V DC 50 cm
Applicable
Series
20 mm 2 EG MBT 00
25 mm 10 EG MBT 05
30 mm 10 EG MBT 10
35 mm 10 EG MBT 15
40 mm 10 EG MBT 20 A
194
Busbar Riser Module - EG BY
• It is designed to provide cost advantage and space saving in panels where
busbar trunking module is used.
Applicable
Series
195
Other Accessories
Material
: Steel sheet
Surface
: Galvanized
Content
: 1 piece of Left fixing bracket
1 piece of Right fixing bracket
2 pieces of M12 steel anchorage bolt
Applicable
Series
Laptop Table - EG DB
It is designed for laptop use during service and maintenance.
• Thanks to its folding design, it does not take up space in the enclosure.
• It is fixed on support rails located at inner side of the door.
Applicable
Series
Laptop table
Enclosure Rated Width Order Code Dimension A Dimension B
196
Corner Module - EG KM
It is designed to create a layout with corner in accordance with the mounting
125
location.
Applicable
Series
Corner module
Enclosure Enclosure Enclosure Enclosure
Order Code Order Code
Rated Height Rated Depth Rated Height Rated Depth
Screen Module - EG MR
It is designed for housing monitor/keyboard.
Applicable
Series
Screen module
Order Code EG MR
197
Other Accessories
Cable Module - EG CM
It is designed to make easy the entry and exit of cables into the panel in the
sections with cable density. With this product, the depth sizes of only the relevant
panels will be expanded without increasing the depth of all panels.
Cable module
Enclosure Enclosure Enclosure Enclosure
Order Code Order Code
Rated Height Rated Depth Rated Height Rated Depth
198
TECHNICAL INFORMATION
199
Forced ventilation airflow calculation according to IEC 61439-2
Verification of the temperature-rise of an assembly with active cooling (e.g., forced cooling, internal air conditioning, heat exchanger,
etc.) and a total supply current not exceeding 1 600 A may be made by calculation.
Calculation procedure
1) Calculate the permissible air temperature-rise inside the assembly by subtracting the maximum ambient air temperature outside
the assembly from the lowest permissible maximum operating air temperature of all devices and components installed in the
assembly as declared by the device manufacturer.
2) Determine the total effective power loss as explained in [Link] of IEC 61439-1:2020. The effective power losses of all circuits
including interconnecting conductors shall be calculated assuming the circuits are operating at their group rated current.
3) Calculate the maximum power loss the assembly enclosure can dissipate without ventilation and active cooling by using the
method given in IEC TR 60890 or the enclosure manufacturer’s declared power dissipation data.
4) Determine the power to be dissipated by active cooling by subtracting the maximum power loss the enclosure can dissipate
without ventilation and active cooling from the total effective power loss.
5) From the cooling equipment manufacturer’s data, determine the cooling equipment required (e.g., a fan) to ensure that the power
to be dissipated by the active cooling can be removed by the active cooling without the air temperature-rise inside the enclosure
𝑃𝑃𝑃𝑃−𝑃𝑃𝑃𝑃890 𝑃𝑃𝑃𝑃 −𝑃𝑃𝑃𝑃
exceeding the permissible maximum value. 𝑉𝑉𝑉𝑉𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚 = [𝑚𝑚𝑚𝑚3 /𝑠𝑠𝑠𝑠] = 3,1 ∙ 𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙 𝑒𝑒𝑒𝑒𝑖𝑖𝑖𝑖𝑒𝑒𝑒𝑒𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒𝑒 [𝑚𝑚𝑚𝑚3 /ℎ]
1160∙𝑘𝑘𝑘𝑘∙�𝑇𝑇𝑇𝑇𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖,𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚 −𝑇𝑇𝑇𝑇𝑚𝑚𝑚𝑚 � 𝑘𝑘𝑘𝑘∙(𝑇𝑇𝑇𝑇𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖𝑖,𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚 −𝑇𝑇𝑇𝑇𝑚𝑚𝑚𝑚 )
It is essential to take care how to select the correct fan. In general fans are usually described by two different properties. The first-
one is its performance in case of free air flow, and the second-one is given in case of working against a load, for example, a grille or
a filter. This second value, which is the lower one, shall be used to select the correct fan.
Aşağıda Grafik-1’de
Aşağıda Grafik-1’de
yaklaşık yaklaşık
540 m3/h 540
anmam3/h debisine
anma debisine
sahip örnek
sahipbirörnek
fana bir
ait fana
performans
ait performans
grafiği verilmiştir.
grafiği verilmiştir.
Grafik-2’de
Grafik-2’de
ise yinecurve
Performance örnek
ise of
yine
aolarak
örnek
sample filtre
fanolarak
kullanımı
filtre kullanımı
ve cihaz yerleşimlerine
ve cihazPerformance
yerleşimlerine
görecurve
fanof
göre
performansında
samefan performansında
sample meydana
fan intersect withmeydana
gelen
two gelen
different impedance curve showing actual airflow at two
değişimleri
değişimleri
göstermektedir.
göstermektedir. different working conditions
Static Pressure
Static Pressure
(Pascals)
(Pascals)
Sample performance
Yukarıdaki curve
Yukarıdaki
örnekteki of a imaginary
örnekteki
değerlerden fananlaşılacağı
değerlerden
de withde
filter;
anlaşılacağı
üzere panoda
üzere panoda
kullanılmak
kullanılmak
üzere seçilecek
üzere seçilecek
fanların fanların
sadece katalog
sadece katalog
değeri üzerinden
değeri üzerinden
hesaplama
hesaplama
yapmakyapmak
uygun değildir.
uygun değildir.
Katalog Katalog
değerinden
değerinden
seçilecekseçilecek
Pointolan
1 - Sample
fanın
olan540
tüm m3/h
fanın
bu rated
bu fan
dirençler
tüm hasönüne
a performance
dirençler
göz gözalınarak curve
önüne alınarakthat intersect
akış debisinin
akış withörneğin
debisinin
örneğin horizontal
%30 değeri
%30airflow axehesaplara
hesaplara
değeri at 540 m3/h where static
pressure is zero, which means air is flowing without resistance.
katılmalıdır.
katılmalıdır.
Bu durumda
Bu durumda
katalog katalog
değeri 540
değeri
m3/h540olan
m3/h
bir olan
fan için
bir akış
fan için
debisi
akıştüm
debisi
bu dirençler
tüm bu dirençler
öngörülerek
öngörülerek
180 m3/h180
olarak
m3/hhesaba
olarak katılmalıdır.
hesaba katılmalıdır.
Point 2 - This fan is placed in a fan unit and mounted on top of a fully equipped assembly; which means air is flowing with resistance
at 445 m3/h
Point 3 - After 6 months the airflow rate of this fan unit with filter (if it’s filter mat is not kept clean) is reduced to 180 m3/h
Use of forced ventilation requires maintenance to ensure consistent performance during the whole life of the assembly. Fan with
filter units are ideal for dissipating heat loads cost effectively. The prerequisite is that the ambient air must be relatively clean.
Otherwise, filters are filled with contamination very quickly. Filter mats must be cleaned and/or replaced regularly.
201
Installation considerations
Installation considerations
Push Design
Push Design with Dual Exhaust Pull Design Push / Pull Design Roof Mount Design
Warm air Warm air Warm air Warm air Warm air Warm air Warm air
out the out the out the out the out with out through out through
exhaust exhaust exhaust filter fan filter fan roof-mount roof-mount
grille grille grille filter fan filter fan
Cool air in Cool air in Cool air in Cool air in Cool air in Cool air in
through through through through through through
filter fan filter fan grille filter fan grille grille
A typical application. An extra exhaust grille Pull design is less Push/pull is used Roof mount filter
Pressurizes cabinet to Designers of assemblies using
is added to improve desirableforced
because ventilationtoneed toairrecognize
increase flow there canspace
fans save be ‘grey areas’ within
help keep out dust. air flow and cooling. dust can be sucked through more tightly inside the cabinet.
the assembly where the airflow is adversely
inside the cabinet. affected by the
packed cabinets. forced cooling. The installation of
temperature-critical devices within these spaces shall be avoided (see Figure F.3a)).
The
Filter place
fans of installation
are typically andinstalled
the direction of the
using air flow,Design”
a “Push e.g., pushing air into or sucking air out of the
enclosure, can lead to different results. In case of installing the fan at the top of the enclosure, to
blow air out (see Figure F.3 b)), because
Designers of assemblies usingthe enclosures
forced ventilationare usually
need not completely
to recognize there can be ‘grey areas’ within the assembly where the airflow
air-tight
is adversely affected by the forced gaps,
cooling. orinstallation
The some small holes can
of temperature-critical devices within these spaces shall be avoided (see
modify the air-forced circulation. This effect
Figure 1a)). The place of installation and the direction of the air flow, e.g., pushing air into or sucking air out of the enclosure, can
may
lead to different results. In case of reduce
installingthe
the cooling intop
fan at the some areas of
of the
enclosure, to blow air out (see the enclosure
Figure (see Figure
1b)), because F.3 b)).are
the enclosures
usually not completely air-tightAnother
gaps, orknown consequence
some small is thatthe
holes can modify some
air-forced circulation. This effect may reduce the cooling in some areas the
polluted (unfiltered) air is drawn into of
the enclosure (see Figure 1b)).enclosure
Another known through these gaps.
consequence Based
is that someon
those
polluted (unfiltered) air is drawn intofacts, the pushed-in
the enclosure throughair flow
these design
gaps.
with the fan placed at the bottom of the
Based on those facts, the pushed-in air flow design with the fan placed at
enclosure is the preferable solution in
the bottom of the enclosure is the preferable solution in many cases (See
many cases (See Figure F.3 c)).
Figure 1c).
Fan airflow calculation example
Fan airflow calculation example
Total effective power loss (P) Total effective power loss (P) : 1161 [W]
: 1161 [W]
Enclosure dimensions (HxWxD) : 2000x800x500
Enclosure dimensions mm (HxWxD) : 2000x800x500 mm
Type of installation of enclosure : Separate enclosure, detached on all sides
Tint : 45 °C ; Ta : 25 °C ; P890 : Type of (From
264 [W] installation ofAltitude
Table-3); enclosure
: 100: Separate
[m] enclosure, detached on all sides
Important Note
Integral cooling fans of equipment like motor drives, power supplies, etc. posi�oned inside an assem
help achieve homogeneous temperature distribu�on. They have limited effect on heat removal from
assembly. In such cases addi�onal measures (like roof top fan and filter unit) to prevent excessive
temperature-rise shall be considered.
202
E-Kabin products cooling power values
Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W)
203
Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W)
204
IP 55 E-Kabin E Series cooling power values
Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W)
800 800 250 54 77 102 129 156 184 53 77 101 127 154 182 51 73 96 121 147 173 46 66 87 110 133 157
950 800 250 64 91 121 152 184 217 60 86 113 142 172 204 53 76 101 127 153 181 52 75 99 124 150 177
1100 800 250 69 99 131 165 200 236 68 97 128 161 195 230 62 89 118 148 179 211 56 81 107 134 163 192
1250 800 250 72 103 135 170 206 243 69 99 131 164 198 234 64 92 122 153 185 218 75 107 141 177 214 252
1500 600 220 62 89 117 147 178 210 60 86 114 143 173 204 52 74 98 123 149 176 63 91 120 150 182 214
1500 800 220 89 127 167 210 254 300 83 119 156 196 238 281 75 107 141 177 214 253 88 125 165 207 251 297
1800 600 220 79 112 148 186 225 266 72 103 136 171 207 245 63 90 119 149 181 213 80 115 152 190 231 272
1800 800 220 101 145 191 240 291 343 97 139 183 230 279 329 90 128 169 212 257 304 113 161 213 267 323 382
2000 600 220 89 127 168 211 255 301 85 121 160 200 243 286 72 103 135 170 206 243 91 130 172 216 261 309
2000 800 220 112 161 212 266 322 381 108 155 204 256 310 367 98 140 184 231 280 331 125 178 235 295 357 422
Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W)
Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W) Maximum Power Distribution (W)
205
Stainless Steel Electrical Enclosures
Stainless steel self-repair feature In industrial environments, chlorides can be existing in smoke
and flying ashes. These are dirt and debris deposits on non-
Oxygen Passive Layer
washed, uncleaned surfaces and eventually they may cause
point corrosion. Even if the right stainless steel is chosen,
corrosive substances condensed in the accumulation of
impurities in that way, may cause the protective passive layer
on the stainless steel surface to be pierced. In such cases,
Stainless steel
cleaning is necessary. By this way, self-repairing of stainless
The metallic satin finish of the stainless steel makes steel material can be provided and the stainless steel surfaces
itself passive, if a suitable environment is provided, can be prevented from condensation of sulfur-dioxide, chloride
i.e. sufficient oxygen and available rich chromium
or ferrous deposits.
oxidation.
This reaction occurs spontaneously in very short time In another particular attention should be paid not only to the
once the sufficient oxygen contacts on the surface, general climatic conditions, but also to the specific micro-
and the protective layer thus formed becomes thick climatic conditions where the enclosure is to be mounted.
over time. The most obvious example to this, is the negative effect in
the settlement areas especially in highways, where salt and
The resistance against corrosion on the surface has the
chemicals are is used as de-icing, which can be carried up to
ability to repair itself in case of mechanical defection.
a distance by the vehicles. Likewise, the effects of increased
exhaust gas emission by the dense and stopped traffic on
Environment and its conditions; the underpass, in the tunnel or at the ticket office, can be
The climate of the area where the application will be, has a evaluated in terms of attracting attention to the micro-climatic
great effect on the corrosion resistance of the stainless steel conditions.
material.
Which grade of stainless steel?
For example, 304 grade stainless steel is resistant to corrosion 304 grade stainless steel is the most widely used type in
under a wide range of environment conditions and climate different applications where a special corrosion resistance
effects, but it is inevitable to experience corrosion in salt and is not required. More harsh environments require the use
other chloride environments. De facto, 304 grade stainless of 316 qualities which is more expensive grade of stainless
steel should not be used up to 10 km inside by the sea coast; steel. However, even for 316 grade stainless steel, chemicals,
but the actual length of this distance can be determined by their concentration and their level of aggressiveness in the
evaluating the climatic conditions according to the application environment must be examined, evaluated and observed in
area specifications. By this reason, it is not recommended to deep detail; because there may be cases where this grade is
use 304 grade stainless steel in marine applications without not sufficient.
206
304 Grade Stainless Steel
SEA 304-304L / EN 1.4301-1.4303
Classified as 304 grade by the American Society of
Automotive Engineers - SAE, stainless steel contains 18-20%
chromium and 8-10.5% nickel. The 304 grade sometimes
referred to as ‘18 -8 ‘, is widely used as standard stainless steel
grade in different industrial applications. The most common
application where the use of 304 quality stainless steel is
inconvenient, is the outdoor applications in the coastal areas
where the salt is deposited on the surfaces by flying.
207
of chloride concentration in the contact zones considerably
increase the likelihood of corrosion.
208
Water which may accumulate during storage and transport, removed by gentle cleaning creams and polishing pastes
especially under heat shrinkage or under the plastic packaging which are available in the market. These cleaning products
of the stretch-film construction, may cause corrosion. This contain substances that can penetrate the surface together
is the case when the packaged product is left in a humid with calcium carbonate. Household cleaners are also based
environment for a long time. on lemon acid and suitable for cleaning. Grinding powders
containing iron adhering to the surface in a short time ago,
Strong acids (chloride based) which can be used for cleaning should be cleaned with saturated solutions of oxalic acids.
after ground work, especially stone or ceramic laying in new Firstly, it must be applied to the surface without pressing
buildings, should be prevented from getting in contact with hardly with a soft cotton cloth or cotton-based polishing pad
stainless steel surfaces. Any cleaning or rinsing fluid must not and waited for a few minutes. Thus, as a rule, it is ensured
be interacted with the surrounding metals. that the particles are separated from the surface without
scratches and damages on the surface. Moderate level
During storage, transfer, positioning and assembling in rust stains are cleaned using cleaning products containing
construction site environment, contamination of stainless steel phosphoric acid. Careful cleaning is done without damaging
enclosures’ surfaces with carbon steel or iron must be avoided. the surface and changing color. Alternatively, small amounts
For example, metal machining, grinding or welding around of iron particles treated on the surface are successfully cleaned
stainless steel enclosures should be avoided or precautions with slenderized nitric acid. It is only possible to clean the
should be taken. Carbon steel metal burrs or slag splashing on surface treated with rust thoroughly with acid processing and
the stainless steel surfaces will cause corrosion of splinters. / or passivation to be done professionally. The acid cleaning
process should be considered as a thin layer removal from
the surface. For this, a mixture of nitric acid and hydrofluoric
acid is generally used. Passivation process is a controlled and
accelerated reconstitution of the impaired passive layer on the
surface in the nitric acid environment. However, first of all, the
oil and organic soils on the surface must be cleaned.
Maintenance
For all stainless steel applications, periodic surface
maintenance should be planned and applied during operation.
209
Earthing
Introduction
Main function of an electrical enclosure is to ensure the safety of operator and equipment. Appropriate precautions must be taken
for the safety of personnel, property and electrical equipment located inside enclosures. Even careful design of switching systems and
expert planning cannot prevent unwanted short-circuits when operating electrical systems. These must therefore be equipped with
appropriate short circuit provisions. They must be able to conduct short-circuit currents without impairing safety.
Earthing connections are additional path for electrical current to return safely to the ground without danger to anyone in the event
of a short circuit. If a short circuit did occur, the current would flow through the earthing connection. Causing a fuse blow or a circuit
breaker trip is much preferable than the fatal shock that could result if the current was not grounded.
• EN 61439-1:2011
Low-voltage switchgear and control gear assemblies - Part 1: General rules
• EN 60204-1:2016
Safety of machinery - Electrical equipment of machines - Part 1: General requirements
It shall be verified that the different exposed conductive parts of the enclosure are effectively connected to the earthing terminal or
contact of the protective circuit and that the resistance of the circuit does not exceed 0,1 Ω.
Verification shall be made using a resistance measuring instrument or arrangement which is capable of driving a current of at least
10 A (a.c. or d.c.). The current is passed between each exposed conductive part and the earthing termination point. The voltage drop
between these points is measured. The resistance calculated from the current and this voltage drop shall not exceed 0,1 Ω.
Requirements for earth continuity providing protection against the consequences of faults
within the enclosure
EAE enclosures have been designed to ensure earth continuity protection against the consequences of faults within the enclosure, so
all exposed conductive parts are interconnected together and have low resistance to the earthing terminal. Thus, earthing terminal can
be bonded via an earthing conductor to the earthing arrangement of the system. These interconnections may be achieved either by
metal screwed connections, welding or other conductive connections or by a separate protective conductor.
For the continuity of these connections during operation or maintenance the following shall apply:
a) When a part of the enclosure is removed, for example for routine maintenance, the protective circuits (earth continuity) for the
remainder of the enclosure shall not be interrupted.
b) For lids, doors, cover plates and the like, the usual metal screwed connections and metal hinges are considered sufficient to ensure
continuity provided that no electrical equipment exceeding the limits of extra low voltage (ELV) (50 V AC or 120 V DC see: IEC 61140-
2016) is attached to them.
If apparatus with a voltage exceeding the limits of extra-low voltage are attached to lids, doors, or cover plates additional measures
shall be taken to ensure earth continuity, therefore EAE accessories shall be mounted as protective conductors. These parts shall be
fitted with a protective conductor (PE) whose cross-sectional area is in accordance with EN 61439-1:2011 Table 3 depending on the
210
highest rated operational current Ie of the apparatus attached, if the rated operational current of the attached apparatus is less than or
equal to 16 A or an equivalent electrical connection especially designed and verified for this purpose (sliding contact, hinges protected
against corrosion).
Exposed conductive parts of a device that cannot be connected to the protective circuit by the
fixing means of the device shall be connected separately to the protective terminal of the enclosure by a conductor whose cross-
sectional area is chosen according to EN 61439-1:2011 Table 3.
The integrated contacting system of EAE enclosures ensure a conducting connection between all elements. The results of our tests
and measurements confirm that the connections possess a contact resistance of less than 0.1 Ω, as demanded in EN 62208:2011.
With regard to the inclusion of the door in the protection measures for “Protection in case of indirect contact” we recommend
connection of a separate earth conductor to the door, when an apparatus is attached on the door and the rated operational current
of the attached apparatus is higher than 16 A. The applicant must determine whether or not the integrated contacting is sufficient for
the earthing system. Attention is here drawn to the regulations and standards. EAE enclosure doors are supplied with 6 mm2 cross-
section earthing cable for attached apparatus rated current up to 63A.
le ≤ 20 S
20 < le ≤ 25 2,5
25 < le ≤ 32 4
32 < le ≤ 63 6
63 < le 10
Integrated contacting
paint-masking
The integrated contacting system of EAE enclosures ensure a
contacting connection between all elements. All elements are
made of galvanized sheet steel even if they are painted for
esthetical reasons.
earthing component
211
self-tapping screw
with earthing feature
212
SİSMİK ÖNLEMLER VE SİSMİK MONTAJ KURALLARI
Seismic Precautions and Seismic Assembly
SİSMİK ÖNLEMLERRules
VE SİSMİK MONTAJ KURALLARI
PanelMaster ürünleri ve bunların sismik uygulamaları IEC 60068-3-3 ve IEC 60890 standartlarına göre ulus
akredite laboratuvarlarda
PanelMaster
PanelMaster products ürünleri
and their test
seismic ve edilerek
bunların
applications havesismik
sismik
been dayanımları
uygulamaları
tested IEC kanıtlanmıştır.
60068-3-3
in internationally ve IECaccredited
recognized 60890 standartlarına
laboratories göre uluslara
according to IEC 60068-3-3
akredite and IEC 60980 standards,
laboratuvarlarda and their
test edilerek seismic
sismik resistance has
dayanımları been verified .
kanıtlanmıştır.
Below is a table of equivalence between seismic classifications depending on the peak ground acceleration value.
0.01 I 0-2
0.01 - 0.02 II 1-2
0
0.02 - 0.05 II 2-3
0.05 - 0.1 IV 3-4
0.1 - 0.2 V 4-5
1
0.2 - 0.5 VI 5-6
2 0.5 - 1 VII 5-7
3 1-2 VIII 6-8
2-5 IX 7-9
5 - 10 X 8 or more than 8
4
10 - 20 XI
DETAIL A
DETAIL B
1. Each panel section will be fixed to the mounting floor with M12 anchor bolts with minimum 8.8 mechanical strength
through 4 mounting holes in its base.
2. Each panel section will be fixed to the reinforced concrete building element by using M12 anchor bolts with strong
brackets made of steel material of minimum 3 mm thickness from at least one of the upper lifting connection bolts.
3. It is assumed that structural elements which the connections are made have their own seismic strength.
214
Steel Wire Connection From Top:
DETAIL A DETAIL A
1. Each panel section will be fixed to the mounting floor with M12 anchor bolts with minimum 8.8 mechanical strength through
4 mounting holes in its base.
2. Each panel section will be fixed to the reinforced concrete building element by using minimum 4.8 mm diameter steel
wire and M12 anchor bolts at carrying rings. Single carrying ring will be used in the first and last sections, and double carrying rings
will be used in the intermediate sections.
3. The angle that the steel wire will create with the upper surface of the cabinet will not exceed 60°
4. It is assumed that structural elements which the connections are made have their own seismic strength.
215
Seismic Rules for Wall
PANELMASTER® Moundted
DİKİLİ TİP KABİNLERİN Panels
(PANOLARIN) SİSMİK MONTAJ KURALLARI
Wall mountedDuvar
panels
tipiwill be fixed
kabinler to reinforced
DUVAR
betonarme TİPİ concrete
KABİNLERİN
duvarlara walls by using 4xM8
(PANOLARIN)
bağlantı SİSMİK
braketlerinden anchor
MONTAJ
minimum bolts
8.8 with minimum
KURALLARI
mekanik 8.8 sahip
mukavemete mechanical
4 adetstrength at
connection brackets.
M8 ankraj cıvatası ile bağlanacaktır. Betonarme Duvar :
ApplicationDuvar
Example:
tipi kabinler
Uygulama Örneği :betonarme duvarlara bağlantı braketlerinden minimum 8.8 mekanik mukavemete sahip 4 adet
M8 ankraj cıvatası ile bağlanacaktır.
Uygulama Örneği :
Uygulama Örneği :
200 mm
280 mm
400 mm
400 mm
300 mm
200 mm
400 mm
56 mm
80 mm
IK Value 01 02 03 04 05 06 07 08 09 10
Falling Height (mm) 56 80 140 200 280 400 400 300 200 400
Equivalent Weight (kg) 0.25 0.25 0.25 0.25 0.25 0.25 0.50 1.70 5 5
217
Framework Assembly
M8 20 Nm
M8x20
YP A Attention!
2 Assembly should be
X - Width done in such a way
1 that this hole detail jill
DP be visible from sides
3 of the framework.
Y - Depth
X4
x8
Y - Depth
X - Width x2
3,9*9,5 M5 M6 M8 M12
2 Nm 3,5 Nm 6 Nm 20 Nm 40 Nm
218
One enclosure framework including plinth and roof panel can be assembled by two worker in 15 minutes.
PACKING
21 cm
21 cm
VERTICAL PROFILE SET
m
6c
20+ MODULE SET
00/2
0/2
18
11 cm
0
FIXED PANEL /12
10
00/1
40 /1
/50 /90
/60 /80
/70 0/70
/80 /6
FRONT DOOR /50
40
219
Notes:
220