I Image Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
II Dose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
III Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
IV Gantry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
V Patient Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
VI User interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
X Room Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2 | GE Healthcare
I Image Chain
X-Ray Generator
The IGS system uses a 100 kW high-frequency Jedi three-phase power unit that provides grid pulsed fluoroscopy capability.
X-Ray Tube
The IGS system is equipped with the high-performance, highly reliable Performix™ 160A metal X-ray tube, which meets requirements for
all vascular applications.
• 3200 W (continuous)
Fluoroscopic power
• 4500 W (peak capability for maximum of 10 minutes)
Leakage radiation (IEC 60601-1-3) <50 mR/h measured at 3.2 kW (125 kv, 25.4 mA)
Collimation
Detector1
The Innova IGS 5 system comes with 3 detector configurations : 20cm detector, 30cm detector or 40cm detector.
Detector manufacturer GE
Mode @ Dose/Fr
Record, e.g. DSA 175 nGy (20 uR) 80% (20 cm detector), 84% (30 cm and 40 cm detector)
Fluoro 8.8 nGy (1 uR) 77% (20 cm detector), 81% (30 cm and 40 cm detector)
Fluoro 2.2 nGy (0.25 uR) 68% (20 cm detector), 73% (30 cm and 40 cm detector)
1
In clinical use, the results of dose reduction techniques will vary depending on the clinical task, patient size, anatomical location and clinical practice.
Physicians assisted by a physicist as necessary have to determine the appropriate settings for each specific clinical task
4 | GE Healthcare
Note: DQE values given are typical at f = 0 cycles/mm with RQA5 conditions as defined by IEC62220-1-3 standards
Anti-scatter Grid: The system is configured with an anti-scatter grid to enhance image quality during routine imaging. Removal of the
grid can improve the X-ray dose efficiency for infants (e.g. less than one-year-old) for field of view (FOV) smaller than 20 cm (7.9 in).
Image acquisition
Fluoroscopy modes Non-subtracted, subtracted, roadmap, Blended Roadmap†
Fluoroscopy frame rate 30 fps, 15 fps, 7.5 fps and 3.75* fps
Fluorostore 450 fluoro images (up to 900)
Sub/no sub simultaneous display† Yes
InnovaSense†
InnovaSense is an advanced patient contouring technology Estimated local cumulated dose Yes
available with 20cm and 30cm detector configurations that uses
an intelligent algorithm during gantry motion to select the optimal Pediatric patient Yes
position for the image receptor relative to the patient. By reducing
the distance from receptor to patient, the system optimizes Real-time calculation Yes
imaging geometry and helps reduce radiation exposure. The user
also can position both the gantry and detector with one integrated Configurable alert Yes
operation. Capacitive sensor technology and optimized collision
avoidance software enable a speed of pivot and C-arm, of up to 20°
per second.
Dose Awareness
Integrated dose monitoring
The user can monitor air kerma rate, integrated air kerma over
the exam, and the total dose area product received by the patient
during a procedure. The threshold of cumulated dose displayed
on a gauge icon is customizable to warn operator when such
threshold has been reached. The threshold is customizable
depending on the protocol.
Dose reporting
The system provides DICOM** compatible Radiation Dose
Structured Report allowing the export of the dose and related
acquisition parameters.
6 | GE Healthcare
III Applications
2D Applications
InnovaChase™ StentVesselViz†
InnovaChase™ is a dynamic, unsubtracted acquisition at a fixed Being able to see the position of stent into the vessel is especially
frame rate of 5 fps with manual and remote panning of the table. critical in cases of complex clinical situations such as bifurcations
It is optimized for visualization of a run off. or calcified lesions. A complete apposition of stent onto vessel wall
can contribute to prevent stent thrombosis and restenosis.
ECG acquisition package†
StentVesselViz† improves the user confidence in the assessment
With the ECG acquisition package the heart rate is displayed on of the position, correct deployment and shape of the stent in
the console and live monitor. relation with the vessel in 2D versus cine.
The ECG acquisition package is compatible with recording system Thanks to an intuitive workflow, StentVesselViz† is operated
outputs providing analog ECG signals comprised between +/-5 V. smoothly and can help the user position and expand stent
Connection cables compatible with Mac-LabTM†, CardioLab™†, appropriately. The StentVesselViz† option delivers from a single
Combolab† and some third party recording systems are provided acquisition a StentViz† image and then the fusion of this one
with this package. with an image of the injected vessel. Those two images are
automatically fading together for optimized and simultaneous
Quantitative Analysis Package† visualization of stent into the vessel pre and post deployment.
Stenosis Analysis† and Left Ventricle Analysis† allow the user to
perform stenosis and left ventricle measurements and analysis.
With OneTouchQA†, the user can select measurement points
with a fingertip directly on the selected image frame displayed
on the Central Touch Screen at tableside – no mouse or joystick
is required. OneTouchQA† is available for stenosis analysis and
distance measurements.
PCI ASSIST†
PCI ASSIST† is an ASSIST package containing StentViz and
StentVesselViz applications and including High Contrast Fluoro
that increases the mA peak up to 36%, and decreases the pulse
width by 38%. While the dose is equivalent, it is delivered in an
efficient way that helps significantly reduce the blurring in the
image due to organ motion.
StentViz†
The StentViz option enhances visibility of the stent structure. It
is particularly useful in verifying placement and deployment of
stents during coronary interventions where moving arteries could
make visibility challenging. StentViz† processing is fully automated
and can be launched at the press of a button on the Central touch
screen. The result is automatically displayed on the reference
monitor and shows two zoomed and enhanced images of the
stent: One with the guidewire in view and a second one where the
guidewire is subtracted out in the area between the two balloon
markers to allow better visualization of the stent struts or borders.
Advantage Paste*
Advantage paste is an application running on AW VolumeShare
Workstation that provides the ability to reconstruct and visualize
the entire length of the subtracted bolus chasing acquisition on a
single image.
InnovaSpin™†
The offset C-arm permits fast-spin rotational angiography over
a maximum range of 200° at variable speeds from 20° to 40°/
sec (maximum speed of 30°/s from LAO to RAO) with flexible
cranio/caudal oblique angulations. The enhanced InnovaSpin™
trajectories are not constrained to a single transverse plane and
can be used at oblique angulations within physical constraints. A
total of seven trajectories can be preset (limited to five on a tilting
table). The entire workflow for the test run and spin acquisition
can take place at tableside. The spin acquisitions can be performed
in the cardiac record mode for coronaries, or peripheral image
quality can be optimized in the InnovaChase™ mode.
INTERACT – ViewX †
INTERACT View X enables display of the Live X-Ray or fusion of
Pre-Op CT with Live X-Ray, on the Vivid E95 / S70N (with ViewX) as
a picture in picture. With INTERACT View X, the echo cardiologist
is able to follow the whole workflow of the procedure from the
echo display, helping facilitate communication between the echo
cardiologist and the interventional cardiologist.
8 | GE Healthcare
3D Applications MAR†
3DCT HD MAR reduces streak artifacts induced by the presence
3DCT*† of small metallic devices such as coils or clips within the 3D field
3DCT is intended for imaging vessels, bone and other internal of view.
body structures. It helps physicians in diagnosis, surgical planning,
interventional procedures and treatment follow-up. 3DCT Motion Freeze†
performs at 40 degree/sec and can be used with 4 different field of 3DCT HD Motion Freeze is designed to reduce artefacts caused by
views. It utilizes automatic exposure technique to optimize image involuntary respiratory motion during the rotational acquisition
quality and dose all along the rotational acquisition. and recover small detail visibility impacted by motion.
Workstations
Two optional workstations, the AW and the CA1000 workstations,
can be connected to the system depending on site requirements.
AW is a multi-modality (CT, MR, XR, TEP, CBCT…) image review,
comparison, and processing workstation. It allows the use
of real-time image fusion applications through a dedicated
communication interface: fastlink (1Gb/sec).
CA1000 provides comprehensive image viewing capabilities for
nearly all DICOM** images in a cardiology-specific display protocol
and it also provides advanced cardiac X-ray analysis tools.
Combination of movements of the C-arm and L-arm Permits -/+55° cranial and caudal angulations
Support Floor-mounted
10 | GE Healthcare
V Patient Table
The Innova IGS 5 system comes with either Omega table (Omega IV table is only available with 20cm detector configuration) or with
InnovaIQ table.
Omega IV Omega V
100 kg (220 lbs.) while complying with the 100 kg (220 lbs.) while complying with the
following -maximum weight requirements: following -maximum weight requirements:
• 40 kg (88lbs.) on each of the two fixed • 40 kg (88lbs.) on each of the two fixed
Maximum accessories weight
side rails side rails
• 20 kg (44 lbs.) of accessories on the table • 20 kg (44 lbs.) of accessories on the table
foot-end rail (option) foot-end rail (option)
CPR 50 kg (110 lbs.) additional maximum load 50 kg (110 lbs.) additional maximum load
Less than 0.85mm Al 1100 Equivalence, Less than 0.85mm Al 1100 Equivalence,
Tabletop absorption
100 KVp 100 KVp
Tabletop Material Radio translucent carbon fiber tabletop Radio translucent carbon fiber tabletop
Tabletop width 46 cm (18 in) in patient trunk area 46 cm (18 in) in patient trunk area
Vertical travel above floor From 78 cm (30.7 in) to 108 cm (42.7 in) From 78 cm (30.7 in) to 108 cm (42.7 in)
Available on the base section of the tabletop Available on the base section of the tabletop
Accessories rails
to mount tableside controls and IV pole to mount tableside controls and IV pole
Maximum accessories weight 116kg (255 lbs.) while complying with the following -maximum weight requirements:
• 40 kg (88 lbs.) on each of the two fixed side rails
• 20 kg (44 lbs.) on each of the two removable side rails
• 16 kg (35 lbs.) for other miscellaneous components/accessories
Vertical travel • Without tilt: From 78 cm (30.7 in) to 108 cm (42.7 in)
• With tilt: From 80 cm (31.5 in) to 137 cm (53.9 in)
Tilting angles 20° Trendelenburg (head down), 12° reverse Trendelenburg (head up) 2
Tilting modes • Isocenter tracking mode to help maintain the region of interest centered during the tilt
• Incidence-keeping mode: The gantry moves in synchronization with the table tilt. In this
mode, clinicians can also pan the table to follow the contrast media
Auto-positioning features Memorizes the table and gantry position simultaneously or separately. Table auto-positioning
includes longitudinal, lateral, vertical and tilt movements of the tabletop.
Interconnect panel Includes connectors for injectors, two potential equalization outlets, gantry and
tableside status control
Accessories rails Available on the base section of the tabletop to mount tableside controls and IV pole
12 | GE Healthcare
Table accessories for InnovaIQ table
Tilt accessories† Dedicated shoulder and foot rests provide optimal patient comfort when using maximum tilt
Anesthesia screen holder† Malleable screen holder that helps separate the patient’s head from the surgical site during
procedures
Removable rails3 Standard size table rails that can be adapted on the trunk section of the table to
accommodate tableside user interface or comfort accessories
Arm boards with cushions† Arm boards with thick pads that can be mounted on the removable rails4
Rail extenders† To be adapted on the head section of the table; can handle up to 15 kg (33 lbs.) of accessories
on each of the two side rails.
2
Typical values
3
Available as an option with the InnovaIQ Table
4
Available in US (0.4 x 1.1 in) and European (10 x 25 mm) standard sizes
Product Data Sheet | 13
VI User interface
In the examination room
The Tableside Status Control (TSSC) provides simple access to key acquisition and review parameters throughout the exam. A
second TSSC can be added at tableside or in the control room. TSSC controls: Acquisition preference settings, fluoro level, fields-of-
view, subtracted/non-subtracted fluoro, fluoro landscape, room light on/off, fluoro timer reset, fluorostore and auto positioner.
To provide more AW capabilities at tableside, an interface kit† enabling to connect an in room wireless mouse to drive the AW from
table side is available.
The IGS system fluoro/acquisition footswitch can optionally come as wireless footswitch†.
Smart Nav is an innovative solution to control some IGS system functionalities from tableside and from the control room. It allows
fast function access in displaying menu controls on the reference monitor upon user request. With Smart Nav, the user can keep his/
her attention on the screen monitors where clinical images are also displayed. Smart Nav is controlled from the central touch screen,
local keypad or remote keypad, providing intuitive and context-based navigation. Smart Nav controls: In-room browser, review and
processing tools, review sequence/photo, stopwatch (play, pause, stop, reset), Dose Map†, StentViz†, StentVesselViz†.
A remote stand is provided to use the second tableside user interface† in the control room
The IGS system includes one B&W 48 cm (19 in) LCD monitor for display of live images in the control room.
Additional reference and subtracted roadmap repeater monitors† are available
Dedicated keypad for convenient control of commonly used review functions provides an image shuttle knob
to control playback and one-touch access to image review functions
Flat graphic display with easy point-and-click mouse control supports patient management and
advanced processing and analysis features
5
The SmartHandle is available with the Omega table only
14 | GE Healthcare
VII In room display
IGS system can be installed with 48 cm (19 in) LCD monitors as primary display or GE Large Display Monitor as primary display.
RX 150
LUT 10 Bit
Frequency 50 – 75 Hz
Power consumption 65 W
AW color monitor
MX 193
Frequency 31 – 64 Hz
8 megapixels
Display matrix
3840 x 2160-pixel array
10 video inputs6 for Live, Reference, AW and optional subtracted Fluoro monochrome
Video inputs signals as well as for a wide variety of other video signals usually used in an interventional
environment – including three free open inputs compatible with VGA and DVI video formats.
• Up to 200
Layouts • Organized into user or application groups
• Digital zoom (up to 200%)
User interface Layouts are selectable from the central touch screen
48 cm (19 in) live and reference monitors attached at the back of the LDM or on
Back-up monitors
another suspension†
Additional HD output† For HD video compatible solutions (second 8MP monitor, 2MP HD monitor, recorder…)
V-Point† In-room HDMI connector for other modality source display on the Large Display Monitor
An optional kit to interface a third-party suspension according to GE Healthcare specifications allows users to install another third-party
suspension instead of the standard GE Healthcare monitor suspension offering.
6
Can optionally be equipped with video processor up to 16 inputs and over 120 layouts
16 | GE Healthcare
VIII Image management, connectivity and workflow
Record images stored in 8 bits, maximum 450 images per sequence. Storage capacity: 136,000 record images
DSA images with 12 bits data stored in 16 bits, maximum 450 images per sequence. Storage capacity: 68,000 DSA images
DICOM image output on 100Mbit Ethernet with Autosend and background transfer for fast transmission with minimal user interaction.
Patient worklist capability provides a single point of entry of patient data, increasing staff productivity and eliminating clerical errors:
patient information can easily be imported into the digital system from information systems that support DICOM Worklist Service
Class Provider.
Multi-destination Push enables images to be sent to multiple remote DICOM destinations sequentially (one after another). Multi-
destination helps to support a clinical scenario of handling post processing and archival activities in multiple destinations independently
of each other (workstation, PACS). Multi-destination provides a seamless integration of the system into clinical workflow.
MPPS: Modality Performed Procedure Step allows the IGS system to share the main exam parameters with the hospital information system.
For the 3DCT/3DCT HD option, users can direct-push the 3D acquisition directly to the pre-configured AW, even if the images of the
exam are pushed to a PACS or another archiving system.
Access controls The provisioning of password-protected user accounts allows controlling the access to sensitive
information of the clinical application and the operating system. The clinical application can be accessed
through local accounts as well as centralized enterprise accounts. Local accounts of the clinical application
and the operating system support password changes, and configuration of complex password rules and
account policies.
User authorization The user accounts are members of role-based groups, which grants the users with the group’s
permissions. It allows restricting the access by unauthorized users to specific parts of the application.
An unauthenticated emergency access mode can be configured, which makes the clinical application
available for clinical procedures.
Audit trails The audit trail capability generates and exports to a central server the audit records of events
related to security and privacy: system state changes, user authentication, account management,
patient data manipulation, malware detection, network communications and service operations.
This provides means to remotely monitor such events, and to protect the system against individuals
falsely denying having performed actions to be covered by non-repudiation.
Anti-malware† A whitelisting-based malware protection contains a list of all authorized executables to create a
closed protected system. It blocks any kind of modification to the whitelisted files as well as the
execution of any unauthorized program. This provides a complete endpoint security against malware.
Firewall The IGS system provides two levels of network firewall: (1) operating system firewall, and (2) external
firewall/router device. These firewalls isolate network traffic to only those systems required for
communication. The firewalls can manage inbound and outbound traffic rules to deny-all and allow-
by-exception based on authorized ports and/or IP addresses.
Data privacy The IGS system provides de-identification and encryption capabilities to limit privacy risks to
sensitive information. The patient data exported during clinical workflow may be encrypted by using
the DICOM TLS protocol. The person names and patient identifying attributes that are collected for
service purposes are anonymized by using FIPS 140-2 compliant one-way hashing algorithms.
18 | GE Healthcare
X Room Requirements
2.71 m with dual arm fix point suspension or 2.74 m with rails
Minimum ceiling height
and bridge suspension (9 ft)
System Power
Supports proper system Supports emergency table control and Supports emergency table control and
shutdown in case of power vital components (preventing to fluoroscopy until the power is restored
outage require to re-boot) until the power is
restored
Customer service
Advanced remote connectivity allows GE to monitor systems and intervene if necessary.
Serviceability
The Digital System Manager simplifies troubleshooting and minimizes downtime with built-in equipment error logging and power-up
diagnostics in real time. Resident software monitors the entire system, including peripheral hardware. The IGS system features 24-hour
InSiteTM remote service diagnostics and repair. InSiteTM service is available to systems covered by the original warranty or by a GE service
contract (broadband required).
Extended service†
An optional full-service contract ensures uptime even after the original warranty expires and provides advanced remote diagnostics
through a broadband or phone connection.
20 | GE Healthcare
Product Data Sheet | 21
22 | GE Healthcare
Product Data Sheet | 23
Product may not be available in all countries and regions .
Cannot be placed on the market or put into service until it has been made
to comply with all required regulatory authorizations including the Medical
Device Directive requirements for CE marking .
Full product technical specification is available upon request .
Contact a GE Healthcare Representative for more information .
Please visit www .gehealthcare .com/promotional-locations .
Data subject to change .
© 2020 General Electric Company . DOC1996665
GE, the GE Monogram, imagination at work are trademarks of General
Electric Company .
† Option
*Requires AW .
**DICOM is a registered trademark of National Electrical Manufacturers
Association, All third party trademarks are the property of their respective
owners .
IGS system refers to Innova IGS 5 system
Reproduction in any form is forbidden without prior written permission
from GE . Nothing in this material should be used to diagnose or treat any
disease or condition . Readers must consult a healthcare professional .
GEA33295A I 12/2020