Carrier Refrigeration Unit Selection Guide
Carrier Refrigeration Unit Selection Guide
Selection Guide
CONTENTS
Recommendations p. 6-7
Multi-temperature units
- Specifications p. 10
- Special test procedure and certification p. 11-12
1
CONTENTS
Notes p. 74
-20 0 +6
°C +2 +8
+30˚C +40˚C °C °C
38 m3 27 m3
51 m3 33 m3
61 m3 42 m3
3
TRANSPORT TEMPERATURE
4
CALCULATING THE VEHICLE BODY'S
THERMAL RATING
To determine the thermal rating of the vehicle body, use the following
formulae:
5
RECOMMENDATIONS
6
RECOMMENDATIONS
8
2- Special testing of unit and body
(Valid only in France, Germany and Italy)
Based on the reports certifying the insulation of the body and the refrig-
eration capacity of the unit, the unit + body assembly may be
approved using the following formula:
K x Ms x ∆T x 1,75
K = insulating factor, Ms = mean surface area of the walls in m2
Ms = (mean interior surface area x mean exterior surface area)
NOTE: The K factor of bodies intending to be classified as B or C
must not exceed 0,4 W/ m2 °C.
SIGNS, IDENTIFICATION MARKS AND PLATES TO BE ATTACHED:
REFRIGERATED UNIT
This reference must be followed by the appropriate identification
marks from the following list:
Standard Class A refrigerated unit . . . . . . . . . . .FNA
Reinforced Class A refrigerated unit . . . . . . . . . .FRA
Reinforced Class B refrigerated unit . . . . . . . . . .FRB
Reinforced Class C refrigerated unit . . . . . . . . . .FRC
In addition to the above identification marks, the date (month and
year) of expiry of the approval certificate must be indicated.
Example : MODEL
FRC
6 - 2010 (6 = June, 2010 = year)
IMPORTANT
Check the expiry date of the approval certificate regularly. This certifi-
cate, or equivalent temporary approval documents, must be supplied
when requested by qualified persons.
In the case of transformation of an insulated vehicle for refrigerated
operation, a request for modification of the approval certificate must
be addressed to the regional health authorities.
NOTE : There are other rules and regulations applicable to the transport of
temperature-sensitive cargo (ARI for the USA – JIS for Japan). For further
information on these regulations, please contact our technical depart-
ments.
9
MULTI-TEMPERATURE UNITS
Specifications
When ordering units destined to be fitted in multi-compartment vehi-
cle bodies, you should provide detailed specifications indicating the
following:
• Interior and exterior length of the body,
• Interior and exterior width of the body,
• Interior and exterior height of the body,
• K factor of the body,
• Configuration of the box,
• Type of partition (mobile or fixed),
• Ambient temperature,
• Temperature required inside compartments,
• Products to be transported,
• Road operation and standby operation,
• Truck battery voltage: 12V or 24V,
• Type of use (long distance, local distribution, etc.),
• Other useful information.
Our technicians are at your disposal to assist you in selecting a unit
which corresponds to your customer’s requirements.
10
MULTI-TEMPERATURE UNITS
Special test procedure and certification
1. Total nominal capacity of the host unit
The unit, equipped with one or two evaporators selected by the ma-
nufacturer for a maximum operating surface, is tested to measure the
total refrigeration capacities A at –20°C and B at 0°C.
The total nominal capacity A of the host unit shall be greater than
1.75 times the needs Q of the total body for the specified
class – A ≥ 1.75 Q
Q = K x Ms x ∆T, see Extract of ATP Europe regulations p. 8
2. Measure of the capacity of each evaporator with the host unit
These capacities are measured for each evaporator at –20°C and
0°C. The knowledge of these capacities xi at –20°C and yi at 0°C
will enable the calculation of the useful capacities of these evapora-
tors with the host unit.
12
NOTES
13
14
MAXIMUM AIR TEMPERATURE (average year - in centigrade)
40°
30°
20°
10°
0°
Région où la
Region where
température dépasse
• temperatures are
souvent les 50 ° C
often above 50°C
Carte : Edigraphie
MINIMUM AIR TEMPERATURE (average year - in centigrade)
20°
10°
0°
-10°
-20°
-30°
-40°
-60°
Carte : Edigraphie
15
16
DIESEL UNIT SELECTION GUIDE (trucks and trailers)
Classification C A
Temperature -20˚C (-4˚F) 0˚ +2˚C (+32˚ +35˚F) +6˚ +8˚C (+43˚ +46˚F)
Required K factor 0,32 Watts/m2 ˚C 0,40 Watts/m2 ˚C
MONOTEMPERATURE
• Truck Ambient
SUPRA 450 R404A temperature
SUPRA 550 R404A +30˚C
SUPRA 750/750SW R404A
SUPRA 850 R404A
SUPRA 950 R404A
• Undermount
SUPRA 850 U R404A
SUPRA 950 U R404A
• Vertical
MAXIMA 1000 R404A
MAXIMA 1300 R404A
ULTRA R404A
VECTOR 1800 R404A
MULTITEMPERATURE
SUPRA 750 Mt° R404A
SUPRA 850 Mt° R404A
SUPRA 950 Mt° R404A
SUPRA 950 U Mt° R404A
MAXIMA 1300 Mt° R404A
VECTOR 1800 Mt° R404A
20 25 30 35 40 45 50 55 60 65 70 75 80 85
Note : This selection table is intended as a guide. It has been compiled using experience acquired in normal utilization of our equipment in transport and distribution.
Conformity to these recommendations should guarantee your total satisfaction. The maximum volumes figuring in this table are given for high speed engine operation.
Take into account the unit's standby performance characteristics (these are indicated in the sale literature) if the unit is frequently used on standby.
In case of operation in high ambient temperature or for difficult types of transport (fresh meat, cheese, vegetables, etc.), it is advised to base your choice on a volume equiva-
lent to the next lowest temperature range. For example, with a SUPRA 550, volume should not exceed 35 m3. When one of the parameters (volume, K factor or outside tem-
perature) differs from the above data, you should apply the following formula: • P = K x Ms x ∆T x 1,75 after referring to the refrigerating capacities.
LIMITS OF USE OF THE ABOVE TABLE : • Altitude ≤ 1500 m • Relative humidity ≤ 70%
17
18
DIESEL UNIT SELECTION GUIDE (trucks and trailers)
Classification C A
Temperature -20˚C (-4˚F) 0˚ +2˚C (+32˚ +35˚F) +6˚ +8˚C (+43˚ +46˚F)
Required K factor 0,32 Watts/m2 ˚C 0,40 Watts/m2 ˚C
MONOTEMPERATURE
• Truck Ambient
SUPRA 450 R404A temperature
SUPRA 550 R404A +40˚C
SUPRA 750/750SW R404A
SUPRA 850 R404A
SUPRA 950 R404A
• Undermount
SUPRA 850 U R404A
SUPRA 950 U R404A
• Vertical
MAXIMA 1000 R404A
MAXIMA 1300 R404A
ULTRA R404A
VECTOR 1800 R404A
MULTITEMPERATURE
SUPRA 750 Mt° R404A
SUPRA 850 Mt° R404A
SUPRA 950 Mt° R404A
SUPRA 950 U Mt° R404A
MAXIMA 1300 Mt° R404A
VECTOR 1800 Mt° R404A
20 25 30 35 40 45 50 55 60 65 70 75 80 85
Note : This selection table is intended as a guide. It has been compiled using experience acquired in normal utilization of our equipment in transport and distribution.
Conformity to these recommendations should guarantee your total satisfaction. The maximum volumes figuring in this table are given for high speed engine operation.
Take into account the unit's standby performance characteristics (these are indicated in the sale literature) if the unit is frequently used on standby.
In case of operation in high ambient temperature or for difficult types of transport (fresh meat, cheese, vegetables, etc.), it is advised to base your choice on a volume equiva-
lent to the next lowest temperature range. For example, with a SUPRA 550, volume should not exceed 24 m3. When one of the parameters (volume, K factor or outside tem-
perature) differs from the above data, you should apply the following formula: • P = K x Ms x ∆T x 1,75 after referring to the refrigerating capacities.
LIMITS OF USE OF THE ABOVE TABLE : • Altitude ≤ 1500 m • Relative humidity ≤ 70%
19
SUPRA 450
for small and medium size vehicles
791 780
SUPRA 450
570
1823
540 80
CG
150
250 maxi
95 mini
96
100
525 325 279
21,36°
43
384 446
20
-20 0 +6
°C +2 +8
+30˚C +40˚C °C °C
30 m3 20 m3
33 m3 22 m3
41 m3 26 m3
SUPRA 450
CAPACITY - Ambient temperature + 30°C
Certificate no. M593
Refrigerant R404A
Airflow (AMCA 21085) 1610 m3/h (constant low/high speed)
Capacity at -20°C 2645 W
Capacity at 0°C 4415 W
COMPRESSOR Type TM16
Nb of cylinders / Displacement 6 / 163 cm3
DIESEL ENGINE Type CT 2.29 TV
Nb of cylinders / Displacement 2 / 480 cm3
Rpm 1800/2320 rpm
Maintenance interval 500 h
STANDBY MOTOR
Standby voltage 230/400/3/50 Hz
240/460/3/60 Hz
Power 3,6 kW (50 Hz)
DEFROST Automatic and manual
STANDARD • Cab command • EasyCOLD microprocessor
EQUIPMENT • Start/Stop • Standby/Diesel hourmeter
(T model) • Automatic diesel restart • Sound reduction kit
ACCESSORIES • By-pass oil filter
OR OPTIONS • Fuel heater
• Engine oil drain extension
• Fuel tank • Battery • Battery box
• Automatic phase reverser kit 230/400/3/50/60
• Single compartment control panel
• Supply air sensor
• DataCOLD 500 or 250
VARIANTS • Without sound reduction kit (S model)
• Nordic version
• Unit without standby operation (please consult us)
21
SUPRA 550
for medium size trucks
791 1225
SUPRA 550
570
1823
550 80
CG
180
250 maxi
95 mini
100
87
525 290 239
21,36°
43
423 446
22
-20 0 +6
°C +2 +8
+30˚C +40˚C °C °C
35 m3 24 m3
44 m3 31 m3
53 m3 37 m3
SUPRA 550
CAPACITY - Ambient temperature + 30°C
Certificate no. M572
Refrigerant R404A
Airflow (AMCA 21085) 2250 m3/h (constant low/high speed)
Capacity at -20°C 3240 W
Capacity at 0°C 5490 W
COMPRESSOR Type 05K2
Nb of cylinders / Displacement 2 / 200 cm3
DIESEL ENGINE Type CT 2.29 TV
Nb of cylinders / Displacement 2 / 480 cm3
Rpm 1800/2320 rpm
Maintenance interval 500 h
STANDBY MOTOR
Standby voltage 230/400/3/50 Hz
240/460/3/60 Hz
Power 3,6 kW (50 Hz)
DEFROST Automatic and manual
STANDARD • Cab command • EasyCOLD microprocessor
EQUIPMENT • Start/Stop • Standby/Diesel hourmeter
(T model) • Automatic diesel restart • Sound reduction kit
ACCESSORIES • By-pass oil filter
OR OPTIONS • Fuel heater
• Engine oil drain extension
• Fuel tank • Battery • Battery box
• Automatic phase reverser kit 230/400/3/50/60
• Single compartment control panel
• Supply air sensor
• DataCOLD 500 or 250
VARIANTS • Without sound reduction kit (S model)
• Nordic version
• Unit without standby operation (please consult us)
23
SUPRA 750
for medium to large-size trucks
856 1225
SUPRA 750
644
1823
550 80
CG
210
265 maxi
75 mini
115
87
239
595 290
20°
423 62
461
SUPRA 750
CAPACITY - Ambient temperature + 30°C
Certificate no. M578
Refrigerant R404A
Airflow (AMCA 21085) 2250 m3/h (constant low/high speed)
Capacity at -20°C 3800 W
Capacity at 0°C 6780 W
COMPRESSOR Type 05K2
Nb of cylinders / Displacement 2 / 200 cm3
DIESEL ENGINE Type CT 3.44 TV
Nb of cylinders / Displacement 3 / 719 cm3
Rpm 1800/2200 rpm
Maintenance interval 750/1000 h
(depends on oil, with or without bypass)
STANDBY MOTOR
Standby voltage 230/400/3/50 Hz
240/460/3/60 Hz
Power 4,8 kW (50 Hz)
DEFROST Automatic and manual
STANDARD • Cab command • EasyCOLD microprocessor
EQUIPMENT • Start/Stop • Standby/Diesel hourmeter
(T model) • Automatic diesel restart • Sound reduction kit
ACCESSORIES • By-pass oil filter
OR OPTIONS • Fuel heater
• Engine oil drain extension
• Fuel tank • Battery • Battery box
• Automatic phase reverser kit 230/400/3/50/60
• Single compartment control panel
• Supply air sensor
• DataCOLD 500 or 250
VARIANTS • With ultra low noise system (X model)
• Without sound reduction kit (S model)
• Nordic version
• Unit without standby operation (please consult us)
25
SUPRA 850
for large-size trucks
856 1225
SUPRA 850
644
1823
650 80
CG
220
265 maxi
75 mini
120
105
595 330 272
20
485 62
461
26
-20 0 +6
°C +2 +8
+30˚C +40˚C °C °C
55 m3 43 m3
66 m3 48 m3
77 m3 57 m3
SUPRA 850
CAPACITY - Ambient temperature + 30°C
Certificate no. M541
Refrigerant R404A
Airflow (AMCA 21085) 2500 m3/h (constant low/high speed)
Capacity at -20°C 4910 W
Capacity at 0°C 7810 W
COMPRESSOR Type 05K4
Nb of cylinders / Displacement 4 / 400 cm3
DIESEL ENGINE Type CT 3.44 TV
Nb of cylinders / Displacement 3 / 719 cm3
Rpm 1800/2320 rpm
Maintenance interval 750/1000 h
(depends on oil, with or without bypass)
STANDBY MOTOR
Standby voltage 230/400/3/50 Hz
240/460/3/60 Hz
Power 4,8 kW (50 Hz)
DEFROST Automatic and manual
STANDARD • Cab command • EasyCOLD microprocessor
EQUIPMENT • Start/Stop • Standby/Diesel hourmeter
(T model) • Automatic diesel restart • Sound reduction kit
ACCESSORIES • By-pass oil filter
OR OPTIONS • Fuel heater
• Engine oil drain extension
• Fuel tank • Battery • Battery box
• Automatic phase reverser kit 230/400/3/50/60
• Single compartment control panel
• Supply air sensor
• DataCOLD 500 or 250
VARIANTS • With ultra low noise system (X model)
• Without sound reduction kit (S model)
• Nordic version
• Unit without standby operation (please consult us)
27
SUPRA 950
for large-size trucks
up to 90 m3
940 1225
SUPRA 950
699
1995
652 80
CG
205
195 maxi
60 mini
115
103
645 330 290
21,48°
47
443
521
28
-20 0 +6
°C +2 +8
+30˚C +40˚C °C °C
75 m3 55 m3
88 m3 61 m3
90 m3 73 m3
SUPRA 950
CAPACITY - Ambient temperature + 30°C
Certificate no. M525
Refrigerant R404A
Airflow (AMCA 21085) 2700 m3/h (constant low/high speed)
Capacity at -20°C 6450 W
Capacity at 0°C 10770 W
COMPRESSOR Type 05G
Nb of cylinders / Displacement 6 / 600 cm3
DIESEL ENGINE Type CT 3.69 TV
Nb of cylinders / Displacement 3 / 1123 cm3
Rpm 1800/2250 rpm
Maintenance interval 1000 h
STANDBY MOTOR
Standby voltage 230/400/3/50 Hz
240/460/3/60 Hz
Power 9 kW (50 Hz)
DEFROST Automatic and manual
STANDARD • Cab command • EasyCOLD microprocessor
EQUIPMENT • Start/Stop • Standby/Diesel hourmeter
(T model) • Automatic diesel restart • Sound reduction kit
ACCESSORIES • Fuel heater
OR OPTIONS • Engine oil drain extension
• Fuel tank • Battery • Battery box
• Automatic phase reverser kit 400/3/50
• Single compartment control panel
• Supply air sensor
• DataCOLD 500 or 250
VARIANTS • With ultra low noise system (X model)
• Without sound reduction kit (S model)
• Nordic version
• Unit without standby operation (please consult us)
29
SUPRA 850U
undermount unit
for your large-size trucks,
draw-bar and city trailers
SUPRA 850U
590
645
1794
Weight: 463 kg
2 1450
75
219
Weight: 52 kg
30
-20 0 +6
+30˚C +40˚C ˚C +2 +8
˚C ˚C
53 m3 42 m3
64 m3 47 m3
75 m3 56 m3
SUPRA 850U
CAPACITY - Ambient temperature + 30°C
Certificate no. M546
Refrigerant R404A
Airflow 2925 m3/h (constant low/high speed)
Capacity at -20°C 4685 W
Capacity at 0°C 7525 W
COMPRESSOR Type 05K4
Nb of cylinders / Displacement 4 / 400 cm3
DIESEL ENGINE Type CT 3.44 TV
Nb of cylinders / Displacement 3 / 719 cm3
Rpm 1800/2320 rpm
Maintenance interval 1000 h
STANDBY MOTOR
Standby voltage 400/3/50 Hz
Power 5 kW (50 Hz)
DEFROST Automatic and manual
STANDARD • Sound reduction kit
EQUIPMENT • Cab command
• Microprocessor
• Standby/Diesel hourmeter
• Defrost timer
• Start/Stop
• Automatic diesel restart
• Standby cable
ACCESSORIES • Fuel heater
OR OPTIONS • Fuel tank
• Battery • Battery box
• Automatic phase reverser kit 400/3/50
• Single compartment control panel
• Supply air sensor
• Water proof box for cab command
• DataCOLD 500 or 250
31
SUPRA 950U
undermount unit
for your large-size trucks,
draw-bar trailers and semi-trailers
SUPRA 950U
823
631
1860
Weight: 553 kg
2 1450
75
219
Weight: 52 kg
32
-20 0 +6
+30˚C +40˚C ˚C +2 +8
˚C ˚C
65 m3 52 m3
80 m3 58 m3
90 m3 72 m3
SUPRA 950U
CAPACITY - Ambient temperature + 30°C
Certificate no. M543 add1
Refrigerant R404A
Airflow 2925 m3/h (constant low/high speed)
Capacity at -20°C 6300 W
Capacity at 0°C 10700 W
COMPRESSOR Type 05G
Nb of cylinders / Displacement 6 / 600 cm3
DIESEL ENGINE Type CT 3.69 TV
Nb of cylinders / Displacement 3 / 1123 cm3
Rpm 1800/2250 rpm
Maintenance interval 1000 h
STANDBY MOTOR
Standby voltage 400/3/50 Hz
Power 9 kW (50 Hz)
DEFROST Automatic and manual
STANDARD • Cab command
EQUIPMENT • Microprocessor
• Standby/Diesel hourmeter
• Defrost timer
• Start/Stop
• Automatic diesel restart
• Standby cable
ACCESSORIES • Sound reduction kit
OR OPTIONS • Fuel heater
• Fuel tank
• Battery • Battery box
• Automatic phase reverser kit 400/3/50
• Single compartment control panel
• Supply air sensor
• Water proof box for cab command
• DataCOLD 500 or 250
33
SUPRA 750 SW
for swap-bodies
1735 705
SUPRA 750 SW
627
705 80 550
115
87
445
503
239
283
290
491 423
580
130 134
34
-20 0 +6
°C +2 +8
+30˚C +40˚C °C °C
42 m3 30 m3
57 m3 38 m3
66 m3 46 m3
SUPRA 750 SW
CAPACITY - Ambient temperature + 30°C
Certificate no. M578
Refrigerant R404A
Airflow (AMCA 21085) 2250 m3/h (constant low/high speed)
Capacity at -20°C 3800 W
Capacity at 0°C 6780 W
COMPRESSOR Type 05K2
Nb of cylinders / Displacement 2 / 200 cm3
DIESEL ENGINE Type CT 3.44 TV
Nb of cylinders / Displacement 3 / 719 cm3
Rpm 1800/2200 rpm
Maintenance interval 750/1000 h
(depends on oil, with or without bypass)
STANDBY MOTOR
Standby voltage 230/400/3/50 Hz
240/460/3/60 Hz
Power 4,8 kW (50 Hz)
DEFROST Automatic and manual
STANDARD • Watertight remote display
EQUIPMENT • EasyCOLD microprocessor
(T model) • Start/Stop • Standby/Diesel hourmeter
• Automatic diesel restart • Sound reduction kit
• Oil drain and water drain extensions
ACCESSORIES • By-pass oil filter
OR OPTIONS • Fuel heater
• Water drain heaters
• Extra flat fuel tank • Battery • Battery box
• Automatic phase reverser kit 230/400/3/50/60
• Single compartment control panel
• Temperature gauge
• Supply air sensor
• DataCOLD 500 or 250
VARIANTS • Nordic version
35
MAXIMA 1000
for draw-bar and city trailers
1888
MAXIMA 1000
1930
420
Body opening:
L 940 x H 980 mm
L 1700 x H 1170 mm with standard opening
option 1930
Weight:
795 kg (road and standby versions)
765 kg (road only version)
119
543
36
-20 0 +6
°C +2 +8
+30˚C +40˚C °C °C
72 m3 52 m3
85 m3 57 m3
90 m3 68 m3
MAXIMA 1000
CAPACITY - Ambient temperature + 30°C
Certificate no. M524
Refrigerant R404A
Airflow (AMCA 21085) 4600 m3/h
Capacity at -20°C 6250 W
Capacity at 0°C 10100 W
COMPRESSOR Type 05K4
Nb of cylinders / Displacement 4 / 400 cm3
DIESEL ENGINE Type CT 4.91TV
Nb of cylinders / Displacement 4 / 1500 cm3
Rpm 1600 rpm
Maintenance interval 1500/2000 h (according to oil)
STANDBY MOTOR Standby voltage 400/3/50 Hz
Power 11 kW (50 Hz)
DEFROST Automatic or manual
STANDARD EQUIPMENT
R model • EasyCOLD microprocessor
Diesel only • Battery 12 V
• By-pass oil filter
• Defrost timer
• Automatic Start/Stop
S model + . . . • Standby operation
Diesel/electric • Standby/Diesel hourmeter
• Automatic diesel restart
T model + . . . • Automatic phase reverser
Diesel/electric • Supply air sensor
ACCESSORIES • Fuel tank • Fuel heater
OR OPTIONS • 24 V additional alternator
• Standard opening bulkhead
• Supply air sensor
• Single compartment control panel
• DataCOLD 500 or 250
37
MAXIMA 1300
for 33-pallet semi-trailers
1888
MAXIMA 1300
2153
424
Body opening:
L 1700 x H 1170 mm
Weight: 2153
119
543
38
-20 0
°C +2
°C
+30˚C +40˚C
90 m3 80 m3
90 m3 90 m3
MAXIMA 1300
CAPACITY - Ambient temperature + 30°C
Certificate no. M576
Refrigerant R404A
Airflow (AMCA 21085) 4950 m3/h
Capacity at -20°C 7200 W
Capacity at 0°C 13300 W
COMPRESSOR Type 05K4
Nb of cylinders / Displacement 4 / 400 cm3
DIESEL ENGINE Type CT 4.91TV
Nb of cylinders / Displacement 4 / 1500 cm3
Rpm 1450/1900 rpm
Maintenance interval 1500/2000 h (according to oil)
STANDBY MOTOR Standby voltage 400/3/50 Hz
Power 11 kW (50 Hz)
DEFROST Automatic or manual
STANDARD EQUIPMENT
R model • EasyCOLD microprocessor
Diesel only • Battery 12 V
• By-pass oil filter
• Defrost timer
• Automatic Start/Stop
S model + . . . • Standby operation
Diesel/electric • Standby/Diesel hourmeter
• Automatic diesel restart
T model + . . . • Automatic phase reverser
Diesel/electric • Supply air sensor
ACCESSORIES • Fuel tank • Fuel heater
OR OPTIONS • Additional electrical heating (S or T model only)
• 24 V additional alternator
• Sound reduction kit
• Supply air sensor
• Single compartment control panel
• DataCOLD 500 or 250
39
VECTOR 1800
for 33-pallet semi-trailers
2050
VECTOR 1800
2227
430
107
Body opening:
L 1700 x H 1170 mm
1155
Weight: 930 kg
2227
430
40
-20
˚C
+30˚C +40˚C
90 m3 90 m3
VECTOR 1800
CAPACITY - Ambient temperature + 30°C
Certificate no. M580
Refrigerant R404A
Airflow (AMCA 21085) 5600 m3/h
Capacity at -20°C 9600 W
Capacity at 0°C 18000 W
COMPRESSOR Type 06D
Nb of cylinders / Displacement 6 / 660 cm3
Operating voltage 400/3/50 Hz
460/3/60Hz
Power 13 kW (50 Hz)
DIESEL ENGINE Type CT 4.134 TV
Nb of cylinders / Displacement 4 / 2200 cm3
Rpm 1350/1950 rpm
Maintenance interval 1500 h / 3000 h (according to oil)
DEFROST Automatic or manual
STANDARD EQUIPMENT
S model • LogiCOLD Microprocessor
Diesel/electric with communication in 8 languages
• Data recorder
• "Eco mode" fuel saving system
• Automatic phase reverser
• Automatic diesel restart
• Supply air sensor
T model + . . . • Sound reduction kit
Diesel/electric
ACCESSORIES • Fuel tank • PCMCIA card for data download
OR OPTIONS • 24V tail lift battery charger • Fuel heater kit
• Additional temperature sensors kit
• Door switch kit
• Single compartment control panel
• DataCOLD 500 or 250
• IntelliSet: micro-programming feature with plain
language display
VARIANTS • VECTOR 1800E electric only unit
41
ULTRA
for semi-trailers
1880
ULTRA
2146
94
83
1156
Body opening:
1697 x 1168 mm
Weight: 845 kg (NDM)
759 kg (NDA) 546
42
-20
˚C
+30˚C +40˚C
90 m3 90 m3
ULTRA
CAPACITY - Ambient temperature + 30°C
Certificate no. M 561
Refrigerant R404A
Airflow (AMCA 21085) 4875 m3/h
Capacity at -20°C 10290 W
Capacity at 0°C 17360 W
COMPRESSOR Type 05G
Nb of cylinders / Displacement 6 / 644 cm3
DIESEL ENGINE Type CT 4.134TV
Nb of cylinders / Displacement 4 / 2200 cm3
Rpm 1400/1700 rpm
Maintenance interval 1500/3000 h (according to oil)
STANDBY MOTOR
Standby voltage 400/3/50 Hz
460/3/60 Hz
Power 13 kW (50 Hz)
DEFROST Automatic and manual
ACCESSORIES • Fuel tank
OR OPTIONS • DataCOLD 500 or 250
VARIANTS • Unit without standby operation
43
SOLARA
to protect your semi-trailer cargo
in low ambient conditions
SOLARA
73
692
845
17 442 206 1067
694
915
Weight: 200 kg
445 188
325
395
100
Control box
44
+6
+8
˚C
-30˚C
90 m3
SOLARA
HEATING CAPACITY - Ambient temperature - 30°C
Airflow 5400 m3/h
Capacity at -30°C exterior 8800 W
DIESEL ENGINE
Type CT 2.29TV
Nb of cylinders / Displacement 2 / 480 cm3
Rpm 1350/2400 rpm
Maintenance interval 750 h
45
Multitemperature
Single discharge
MTS : Truck Mt° – MMS : Maxima Mt° – MVS : Vector Mt°
700 mm
MTS 752 mm
MMS
MVS
700
200
mm
Weight: 23 kg
1 044 mm
752 mm
MTS
MMS
MVS 200
mm
1100 Weight: 34 kg
1 450 mm
752 mm
MTS
1450
200 mm Weight: 42 kg
752 mm 2 150 mm
MTS
MMS
MVS
2200
200 mm Weight: 60 kg
46
evaporators
Dual discharge
MTD : Truck Mt° – MMD : Maxima Mt° – MVD : Vector Mt°
700 mm
944
mm MMD*
MVD*
700
167
mm
Weight: 28 kg
944 1 044 mm
mm
MMD*
MVD
167 1100
mm
Weight: 40 kg
944 1 450 mm
mm
MTD*
1450
167
mm
Weight: 51 kg
2 150 mm
944 mm
MTD*
MMD*
MVD
2200
167 mm
Weight: 71 kg
856 1823
644
Body opening: 90 x 90 mm
Weight:
S Model: 411 kg
T Model: 414 kg (sound proofing)
X Model: 419 kg (Silent version)
48
-20
°C
+30˚C +40˚C
35 m3 25 m3
49
SUPRA 750 Mt°
System 1
SUPRA 750 Mt°
1450
Up to 6.5 m
System 2
1100
1100
2 to 4.5 m 2 to
4.5 m
System 3
1450
700
Up to 2 m
Up to 6.5 m
50
System 4
700
700
1450
Up to 6.5 m
Extension kit
System 5
700
1100
Up to 6.5 m
System 7
700
700
700
Up to 6 m
856 1823
644
Body opening: 90 x 90 mm
Weight:
S Model: 443 kg
T Model: 446 kg (sound proofing)
X Model: 448 kg (Silent version)
52
-20
°C
+30˚C +40˚C
40 m3 30 m3
53
SUPRA 850 Mt°
System 1
SUPRA 850 Mt°
1450
Up to 7.5 m
System 2
1450
1100
2 to 2 to
5.5 m 5.5 m
System 3
1450
700
Up to 2 m
Up to 7.5 m
54
CMJK guide TT
System 4
700
700
1450
Up to 7.5 m
Extension kit
System 5
700
700
700
Up to 7.5 m
940
1995
699
56
-20
°C
+30˚C +40˚C
60 m3 50 m3
57
SUPRA 950 Mt°
System 1
2200
SUPRA 950 Mt°
Up to 9 m
System 2
1450
1450
2 to 7 m 2 to 7 m
System 2 bis
1450
1100
2 to 7 m 2 to 7 m
System 3
1450
700
Up to 2 m
Up to 9 m
58
System 4
700
700
1450
1450
Up to 9 m
Extension kit
System 6
System 7 1100
1100
700
Up to 2 m
2 to 2 to
5m 5m
System 8
1100
1100
700
Up to 9 m
System 9
700
700
1450
Up to 4 m
Up to 9 m
631
1972
623
Weight:
S Model: 580 kg
T Model: 585 kg
60
-20
°C
+30˚C +40˚C
60 m3 50 m3
61
SUPRA 950U Mt°
SUPRA 950U Mt°
System 1
2200
Up to 9 m
System 2
1450
1450
2 to 7 m 2 to 7 m
62
SUPRA 950U Mt°
System 3
1450
700
Up to 2 m
Up to 9 m
System 4
700
1450
Up to 9 m
2162
424
1888
2162
Mt
Body opening:
L 1700 x H 1170 mm
Weight:
815 kg
119
543
64
-20
°C
+30˚C +40˚C
90 m3 75 m3
65
MAXIMA 1300 Mt°
MAXIMA 1300 Mt°
System 1
2200
A
MAXIM
I200
Up to 11 m*
System 3
1100
A
MAXIM
I200
Up to 7 m*
66
MAXIMA 1300 Mt°
System 4
A
MAXIM
I200
700
Up to 10 m*
System 5
A
1100
MAXIM
I200
2227
430
2050
107
1155
2227
Body opening:
L 1700 x H 1170 mm
Weight: 955 kg
430
68
-20
˚C
+30˚C +40˚C
90 m3 90 m3
System 1
VECTOR 1800 Mt°
Up to 11 m*
2200
System 1bis
Up to 11 m*
2200
System 2
Up to 7 m*
1100
System 2bis
Up to 7 m*
1100
70
System 3
700
Up to 10 m*
System 3bis
System 4
Up to 5 m* Up to 5 m*
1100
1100
System 5
3-9 m* Up to 8 m*
2200
2200
System 6
Up to 9 m*
700
700
Up to 9 m*
Model T (External)
Dimensions:
Model T : 245 x 202 x 110 mm
Model R : 188 x 58 x 145 mm
72
DataCOLD 250 (No communication with Carrier unit)
• Sensors Channels: 2.
• Event Channel: 1.
• Data Storage Memory Size: 256 KB, Minimum 1 year with 2
sensors and 15 min. recording interval.
DataCOLD Range
• Storage Intervals: 1-60 min. adjustable.
• Controls Keys: 4 covering all functions.
• Data interface: Infrared port for data downloading & services
parameters.
73
NOTES
74
Our company is constantly seeking to improve the quality of its products and,
therefore, reserves the right to modify its products without prior notice.