High Durability Air Cylinder CM2 Series
High Durability Air Cylinder CM2 Series
Series Variations
Bore size
Series Action Model Cushion Standard stroke
20 25 32 40
Air cylinder
CM2 series
Double acting,
Single rod
CM2-XB24 V V V V Rubber bumper 25 to 300
CM2-XB24
CAT.ES20-286A
High Durability Series
CM2-XB24
ø20, ø25, ø32, ø40
How to Order
q Mounting w Bore size e Port thread type r Cylinder stroke [mm] t Rod end thread
B Basic (Double-side bossed) 20 20 mm Nil Rc Refer to page 2 for standard strokes. Nil Male rod end
L Axial foot bracket 25 25 mm TN NPT F Female rod end
F Rod flange 32 32 mm TF G
G Head flange 40 40 mm
C Single clevis
D Double clevis y Pivot bracket u Rod end bracket i Auto switch
U Rod trunnion Nil No bracket Nil No bracket W Double knuckle joint Without auto
T Head trunnion Nil switch
N Pivot bracket V Single knuckle joint Q Rod end
E Integrated clevis
* O
nly for “C”, “T”, “U”, “E”, “V”, and * No bracket is provided with the female rod end. * For applicable auto
V Integrated clevis (90°) “UZ” mounting types * A knuckle joint pin is not provided with the single knuckle switches, refer to the
BZ Boss-cut/Basic * T
he pivot bracket is shipped together with joint. table below.
FZ Boss-cut/Rod flange the product but does not come assembled. * The rod end bracket is shipped together with the product
UZ Boss-cut/Rod trunnion but does not come assembled.
o Number of auto switches
Nil 2
S 1
n n * Refer to page 2 for the ordering example of cylinder assembly.
Applicable Auto Switches/Refer to the Web Catalog for further information on auto switches.
Load voltage Auto switch model Lead wire length [m]
Indicator light
—— 2-wire 12 V —
Connector — H7C V — V V V —
Terminal 3-wire (NPN) 5 V, 12 V — G39A — — — — V — IC circuit
conduit 2-wire 12 V — K39A — — — — V — —
Relay,
Yes
(NPN equivalent)
A93V A93 V V V V — v*2
100 V —
Grommet
V V V V — v*2 IC circuit
Reed auto switch
Specifications
* P
ivot bracket, single knuckle joint and auto
switch are shipped together with the product
but do not come assembled.
The allowable kinetic energy, allowable loads at the rod end, theoretical output, and weight
are equivalent to those of the Air Cylinder CM2 series. For details, refer to the Web Catalog.
2
High Durability Series
CM2-XB24
Accessories Standard (mounted to the body) Standard (shipped together but does not come assembled) Option
Clevis pivot *5
(CM2E/CM2V)
(CM2E/CM2V)
*1
*7
*5
*5
*6
Single knuckle joint
Mounting nut
(Male thread)
Mounting nut
bracket pin
Rod end
(Male thread only)
Clevis pivot
bracket pin
Mounting
clevis pin
Trunnion
bracket
Double
Double
Flange
bracket
Single
clevis
clevis
Body
Liner
Pivot
Pivot
nut
Mounting
B Basic (Double-side bossed) V(1 pc.) V(1 pc.) V(1 pc.) — — — — — — — — — — — — — V V V
L Axial foot bracket V(1 pc.) V(1 pc.)*2 V(1 pc.) — — — V(1 pc.)*2 V(2 pcs.) — — — — — — — — V V V
F Rod flange V(1 pc.) V(1 pc.) V(1 pc.) — — — — — V(1 pc.) — — — — — — — V V V
G Head flange V(1 pc.) V(1 pc.) V(1 pc.) — — — — — V(1 pc.) — — — — — — — V V V
C Single clevis V(1 pc.) — *3 V(1 pc.) V(1 pc.) — V(Max. 3 pcs.) — *3 — — — — — — — — — V V V
D Double clevis V(1 pc.) — *3 V(1 pc.) — V(1 pc.) V(Max. 3 pcs.) — *3 — — — — V(1 pc.) — — — — V V V
U Rod trunnion V(1 pc.) — *4 V(1 pc.) — — — — — — — — — V(1 pc.) V(1 pc.) — — V V V
T Head trunnion V(1 pc.) — *4 V(1 pc.) — — — — — — — — — V(1 pc.) V(1 pc.) — — V V V
E Integrated clevis V(1 pc.) — *3 V(1 pc.) — — — — *3 — — — — — — — — — V V V
V Integrated clevis (90°) V(1 pc.) — *3 V(1 pc.) — — — — *3 — — — — — — — — — V V V
BZ Boss-cut/Basic V(1 pc.) V(1 pc.) V(1 pc.) — — — — — — — — — — — — — V V V
Boss-cut/
FZ Rod flange V(1 pc.) V(1 pc.) V(1 pc.) — — — — — V(1 pc.) — — — — — — — V V V
Boss-cut/
UZ Rod trunnion V(1 pc.) — *4 V(1 pc.) — — — — — — — — — V(1 pc.) V(1 pc.) — — V V V
G
Width across flats B2 H2 G 2xP 2 x NN
Width across flats B1 H1 (Rc, NPT, G) I
ø
2 x øEh8
NA
øD
Boss-cut
ZZ + Stroke
3.5
H
ZZ + Stroke
[mm]
Bore size A AL B1 B2 D E F FL G H H1 H2 I K KA MM NA NN P S ZZ
20 18 15.5 13 26 8 20−00.033 13 10.5 8 41 5 8 28 5 6 M8 x 1.25 24 M20 x 1.5 1/8 62 116
25 22 19.5 17 32 10 26−00.033 13 10.5 8 45 6 8 33.5 5.5 8 M10 x 1.25 30 M26 x 1.5 1/8 62 120
32 22 19.5 17 32 12 26−00.033 13 10.5 8 45 6 8 37.5 5.5 10 M10 x 1.25 34.5 M26 x 1.5 1/8 64 122
40 24 21 22 41 14 32−00.039 16 13.5 11 50 8 10 46.5 7 12 M14 x 1.5 42.5 M32 x 2 1/4 88 154
4
High Durability Series
CM2-XB24
øI
2 x øLC
B
LH
Width across flats B2 4 x øLD
MM Width across flats NA
Y X S + Stroke X Y LX
LT
Z LS + Stroke LZ
ZZ + Stroke
[mm]
Bore size A AL B B1 B2 D F G H H1 H2 I K KA LC LD LH LS LT LX LZ MM NA P S X Y Z ZZ
20 18 15.5 40 13 26 8 13 8 41 5 8 28 5 6 4 6.8 25 102 3.2 40 55 M8 x 1.25 24 1/8 62 20 8 21 131
25 22 19.5 47 17 32 10 13 8 45 6 8 33.5 5.5 8 4 6.8 28 102 3.2 40 55 M10 x 1.25 30 1/8 62 20 8 25 135
32 22 19.5 47 17 32 12 13 8 45 6 8 37.5 5.5 10 4 6.8 28 104 3.2 40 55 M10 x 1.25 34.5 1/8 64 20 8 25 137
40 24 21 54 22 41 14 16 11 50 8 10 46.5 7 12 4 7 30 134 3.2 55 75 M14 x 1.5 42.5 1/4 88 23 10 27 171
5
High Durability Series
C2
FY
øD
øI
B
øE
2 x øFD FX MM Effective thread length FL
AL Width across flats NA 1.5
ø Mounting FZ Width across flats KA A K FT
hole
ø to ø Z
H S + Stroke F
ZZ + Stroke
Boss-cut
ZZ + Stroke
3.5
H
ZZ + Stroke
[mm]
Bore size A AL B B1 B2 C2 D E F FL FD FT FX FY FZ G H H1 H2 I K KA MM NA NN P S Z ZZ
20 18 15.5 34 13 26 30 8 20−00.033 13 10.5 7 4 60 − 75 8 41 5 8 28 5 6 M8 x 1.25 24 M20 x 1.5 1/8 62 37 116
25 22 19.5 40 17 32 37 10 26−00.033 13 10.5 7 4 60 − 75 8 45 6 8 33.5 5.5 8 M10 x 1.25 30 M26 x 1.5 1/8 62 41 120
32 22 19.5 40 17 32 37 12 26−00.033 13 10.5 7 4 60 − 75 8 45 6 8 37.5 5.5 10 M10 x 1.25 34.5 M26 x 1.5 1/8 64 41 122
40 24 21 52 22 41 47.3 14 32−00.039 16 13.5 7 5 66 36 82 11 50 8 10 46.5 7 12 M14 x 1.5 42.5 M32 x 2 1/4 88 45 154
6
High Durability Series
CM2-XB24
C2
(Rc, NPT, G) Mounting hole
FY
øD
øI
B
øE
3.5
H
ZZ + Stroke
[mm]
Bore size A AL B B1 B2 C2 D E F FL FD FT FX FY FZ G H H1 H2 I
20 18 15.5 34 13 26 30 8 20−00.033 13 10.5 7 4 60 − 75 8 41 5 8 28
25 22 19.5 40 17 32 37 10 26−00.033 13 10.5 7 4 60 − 75 8 45 6 8 33.5
32 22 19.5 40 17 32 37 12 26−00.033 13 10.5 7 4 60 − 75 8 45 6 8 37.5
40 24 21 52 22 41 47.3 14 32−00.039 16 13.5 7 5 66 36 82 11 50 8 10 46.5
[mm]
Bore size K KA MM NA NN P S Z ZZ
20 5 6 M8 x 1.25 24 M20 x 1.5 1/8 62 107 116
25 5.5 8 M10 x 1.25 30 M26 x 1.5 1/8 62 111 120
32 5.5 10 M10 x 1.25 34.5 M26 x 1.5 1/8 64 113 122
40 7 12 M14 x 1.5 42.5 M32 x 2 1/4 88 143 154
7
High Durability Series
NA
øCI
øD
øE
MM AL CX
Width across flats KA A K F U NA
H S + Stroke L
Z + Stroke RR
ZZ + Stroke
Female thread MM
Thread depth A1
3.5
H
ZZ + Stroke
[mm]
Bore size A AL B1 CI CD CX D E F FL G H H1 I K KA L MM NA NN P RR S U Z ZZ
20 18 15.5 13 24 9 10 8 20−00.033 13 10.5 8 41 5 28 5 6 30 M8 x 1.25 24 M20 x 1.5 1/8 9 62 14 133 142
25 22 19.5 17 30 9 10 10 26−00.033 13 10.5 8 45 6 33.5 5.5 8 30 M10 x 1.25 30 M26 x 1.5 1/8 9 62 14 137 146
32 22 19.5 17 30 9 10 12 26−00.033 13 10.5 8 45 6 37.5 5.5 10 30 M10 x 1.25 34.5 M26 x 1.5 1/8 9 64 14 139 148
40 24 21 22 38 10 15 14 32−00.039 16 13.5 11 50 8 46.5 7 12 39 M14 x 1.5 42.5 M32 x 2 1/4 11 88 18 177 188
8
High Durability Series
CM2-XB24
NA
øCI
øD
øE
MM AL U CX
Width across flats KA A K F CZ
H S + Stroke L NA
Z + Stroke RR
ZZ + Stroke
Female thread MM
Thread depth A1
3.5
H
ZZ + Stroke
[mm]
Bore size A AL B1 CD CI CL CX CZ D E F FL G H H1 I K KA L MM NA NN P RR S U Z ZZ
20 18 15.5 13 9 24 25 10 19 8 20−00.033 13 10.5 8 41 5 28 5 6 30 M8 x 1.25 24 M20 x 1.5 1/8 9 62 14 133 142
25 22 19.5 17 9 30 25 10 19 10 26−00.033 13 10.5 8 45 6 33.5 5.5 8 30 M10 x 1.25 30 M26 x 1.5 1/8 9 62 14 137 146
32 22 19.5 17 9 30 25 10 19 12 26−00.033 13 10.5 8 45 6 37.5 5.5 10 30 M10 x 1.25 34.5 M26 x 1.5 1/8 9 64 14 139 148
40 24 21 22 10 38 41.2 15 30 14 32−00.039 16 13.5 11 50 8 46.5 7 12 39 M14 x 1.5 42.5 M32 x 2 1/4 11 88 18 177 188
* A clevis pin and retaining rings (split pins for ø40) are shipped together with the product.
9
High Durability Series
øD
øI
øTY
øE
MM Width across flats NA Effective thread length FL
TX AL
Width across flats KA A K TT
TZ
Z
H S + Stroke F
ZZ + Stroke
Boss-cut
ZZ + Stroke
3.5
H
ZZ + Stroke
[mm]
Bore size A AL B1 B2 D E F FL G H H1 I K KA MM NA NN P
20 18 15.5 13 26 8 20−00.033 13 10.5 8 41 5 28 5 6 M8 x 1.25 24 M20 x 1.5 1/8
25 22 19.5 17 32 10 26−00.033 13 10.5 8 45 6 33.5 5.5 8 M10 x 1.25 30 M26 x 1.5 1/8
32 22 19.5 17 32 12 26−00.033 13 10.5 8 45 6 37.5 5.5 10 M10 x 1.25 34.5 M26 x 1.5 1/8
40 24 21 22 41 14 32−00.039 16 13.5 11 50 8 46.5 7 12 M14 x 1.5 42.5 M32 x 2 1/4
[mm]
Bore size S TD TT TX TY TZ Z ZZ
20 62 8 10 32 32 52 36 116
25 62 9 10 40 40 60 40 120
32 64 9 10 40 40 60 40 122
40 88 10 11 53 53 77 44.5 154
10
High Durability Series
CM2-XB24
øTD
øTY
øD
øI
øE
Female thread MM
Thread depth A1
3.5
H
ZZ + Stroke
[mm]
Bore size A AL B1 B2 D E F FL G H H1 I K KA MM NA NN P
20 18 15.5 13 26 8 20−00.033 13 10.5 8 41 5 28 5 6 M8 x 1.25 24 M20 x 1.5 1/8
25 22 19.5 17 32 10 26−00.033 13 10.5 8 45 6 33.5 5.5 8 M10 x 1.25 30 M26 x 1.5 1/8
32 22 19.5 17 32 12 26−00.033 13 10.5 8 45 6 37.5 5.5 10 M10 x 1.25 34.5 M26 x 1.5 1/8
40 24 21 22 41 14 32−00.039 16 13.5 11 50 8 46.5 7 12 M14 x 1.5 42.5 M32 x 2 1/4
[mm]
Bore size S TD TT TX TY TZ Z ZZ
20 62 8 10 32 32 52 108 118
25 62 9 10 40 40 60 112 122
32 64 9 10 40 40 60 114 124
40 88 10 11 53 53 77 143.5 154 * The bracket is shipped together with the product.
11
High Durability Series
NA
øCI
øD
øE
LH
MM 2 x øLD
Width across flats B1 NN
Width across flats KA Effective thread length FL
LF LG
LT
LY LV
Refer to the Web Catalog for details
on the clevis pivot bracket.
H
* T
he dimensions are the same as those for the ZZ + Stroke
integrated clevis (E).
[mm]
Bore size A AL B1 CD CI CX D E F FL G H H1 I K KA L MM NA NN
20 18 15.5 13 8 20 12 8 20−00.033 13 10.5 8 41 5 28 5 6 12 M8 x 1.25 24 M20 x 1.5
25 22 19.5 17 8 22 12 10 26−00.033 13 10.5 8 45 6 33.5 5.5 8 12 M10 x 1.25 30 M26 x 1.5
32 22 19.5 17 10 27 20 12 26−00.033 13 10.5 8 45 6 37.5 5.5 10 15 M10 x 1.25 34.5 M26 x 1.5
40 24 21 22 10 33 20 14 32−00.039 16 13.5 11 50 8 46.5 7 12 15 M14 x 1.5 42.5 M32 x 2
[mm]
Bore size P RR S U Z ZZ
20 1/8 9 62 11.5 115 124
25 1/8 9 62 11.5 119 128
32 1/8 12 64 14.5 124 136
40 1/4 12 88 14.5 153 165
12
High Durability Series
CM2-XB24
Specific Product Precautions
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For actuator and auto switch precautions, refer to “Handling Precautions for
SMC Products” and the “Operation Manual” on the SMC website: [Link]
Handling
Warning Caution
1. Do not rotate the cover. 1. Cannot be disassembled
If a cover is rotated when installing a cylinder or screwing a fit- Cover and cylinder tube are connected to each other by caulk-
ting into the port, it is likely to damage the joint of the cover. ing method, thus making it impossible to disassemble. Parts
2. Operate the cylinder within the specified cylinder inside the cylinder, such as the rod seal, can never be re-
speed, kinetic energy, and lateral load at the rod placed.
end. 2. Do not touch the cylinder during operation.
3. The allowable kinetic energy is different between Use caution when handling a cylinder, which is running at a
the cylinders with male rod ends and with female high speed and a high frequency, because the surface of the
rod ends due to the different thread sizes. cylinder tube could get hot enough to burn you.
4. When a female rod end is used, depending on the 3. Do not use the air cylinder as an air-hydro cylinder.
material of the workpiece, use a washer etc., to pre- The use of turbine oil as a fluid for an air cylinder may result in
vent the contact part at the rod end from being de- oil leakage.
formed. 4. The oil stuck to the cylinder is grease.
5. Do not apply excessive lateral load to the piston rod. 5. The base oil of the grease may seep out.
Easy checking method The base oil of the grease in the cylinder may seep out of the
Min. operating pressure after the cylinder is mounted to the tube, cover, crimped part, or rod bushing depending on the op-
equipment (MPa) = Min. operating pressure of cylinder (MPa) erating conditions (ambient temperature 40°C or more, pres-
+ {Load mass (kg) x Friction coefficient of guide/Sectional area surized condition, low frequency operation).
of cylinder (mm2)}
6. When a rod end female thread is used, use a thin
If smooth operation is confirmed within the above value, the wrench when tightening the piston rod.
load on the cylinder is the resistance of the thrust only and it
can be judged as having no lateral load. 7. When using a rod end bracket and/or pivot bracket,
make sure they do not interfere with other brackets,
workpieces, rod section, etc.
8. Do not lubricate the cylinder.
Lubrication of the cylinder, using a lubricator, may cause mal-
function.
9. Do not wipe out the grease in the sliding part.
If grease applied to the sliding surface is removed, this can
cause malfunction and reduce the life of the cylinder.
13
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk which,
Caution: if not avoided, could result in minor or moderate injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of risk which,
Warning: if not avoided, could result in death or serious injury.
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
Danger indicates a hazard with a high level of risk which,
Danger : if not avoided, will result in death or serious injury.
Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating conditions, If considering using the product in other industries, consult SMC beforehand
its compatibility with specific equipment must be decided by the person who and exchange specifications or a contract if necessary.
designs the equipment or decides its specifications based on necessary If anything is unclear, contact your nearest sales branch.
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined Limited warranty and Disclaimer/
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog Compliance Requirements
information, with a view to giving due consideration to any possibility of The product used is subject to the following “Limited warranty and Disclaimer” and
equipment failure when configuring the equipment. “Compliance Requirements”.
Read and accept them before using the product.
2. Only personnel with appropriate training should operate
machinery and equipment. Limited warranty and Disclaimer
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
1. The warranty period of the product is 1 year in service or 1.5 years after
our products must be performed by an operator who is appropriately trained
the product is delivered, whichever is first.∗2)
and experienced. Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
3. Do not service or attempt to remove product and machinery/ 2. For any failure or damage reported within the warranty period which is clearly our
equipment until safety is confirmed. responsibility, a replacement product or necessary parts will be provided.
1. The inspection and maintenance of machinery/equipment should only be This limited warranty applies only to our product independently, and not to any
performed after measures to prevent falling or runaway of the driven other damage incurred due to the failure of the product.
objects have been confirmed.
3. Prior to using SMC products, please read and understand the warranty terms
2. When the product is to be removed, confirm that the safety measures as and disclaimers noted in the specified catalog for the particular products.
mentioned above are implemented and the power from any appropriate
∗2) Vacuum pads are excluded from this 1 year warranty.
source is cut, and read and understand the specific product precautions
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
of all relevant products carefully. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
3. Before machinery/equipment is restarted, take measures to prevent or failure due to the deterioration of rubber material are not covered by the limited warranty.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
Compliance Requirements
safety measures if the product is to be used in any of the 1. The use of SMC products with production equipment for the manufacture of
following conditions. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country to another are
outdoors or in a place exposed to direct sunlight. governed by the relevant security laws and regulations of the countries involved
2. Installation on equipment in conjunction with atomic energy, railways, air in the transaction. Prior to the shipment of a SMC product to another country,
navigation, space, shipping, vehicles, military, medical treatment, assure that all local rules governing that export are known and followed.
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the Caution
standard specifications described in the product catalog.
SMC products are not intended for use as instruments for legal
3. An application which could have negative effects on people, property, or metrology.
animals requiring special safety analysis. Measurement instruments that SMC manufactures or sells have not been
4. Use in an interlock circuit, which requires the provision of double interlock qualified by type approval tests relevant to the metrology (measurement) laws
for possible failure by using a mechanical protective function, and of each country. Therefore, SMC products cannot be used for business or
periodical checks to confirm proper operation. certification ordained by the metrology (measurement) laws of each country.
Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.