Note:-Ground improvement measures shall be carried out as per recommendations
Geosynthetics Erosion Control
of the Geotechnical Investigation Report, wherever necessary. Mat with Hydroseeding
Toe Drain
U-Pin
2
Subsurface drain PVC
pipe wrapped with non 1
wowen geotextile
Backfill
Reinforced soil wall
(Gabion fascia mesh size
10x12, 2.7/3.7 mm wire ø, Toe Drain
ZINC+PVC coated) Non-woven Geotextile
0.08(Typ.)
Detail- A
Structural Fill
6°
H BIS Certified High
Strength Geogrid Drainage
Composite
Toe Drain Detail- B
Min. 1.0m
Embedment 100mm Thick PCC In-Situ Strata
TYPICAL CROSS SECTION OF REINFORCED SOIL STRUCTURE
Drawing Title:
LAND SLIDE MITIGATION AT CORTALIM GOA Client: PWD GOA Drawing No: SHEET 1 OF 3
Project:-
CONCEPTUAL SCHEME ONLY HILL SIDE SLOPE PROTECTION MEASURES AT NH 66 NEAR CORTALIM (SANTRANT
Date: 30-05-2025 N.T.S
NOT FOR CONSTRUCTION SLOPE AND FERRY POINT) IN THE STATE OF GOA
Note:-Ground improvement measures shall be carried out as per recommendations
Geosynthetics Erosion Control
of the Geotechnical Investigation Report, wherever necessary. Mat with Hydroseeding
Toe Drain
U-Pin
2
Subsurface drain PVC
pipe wrapped with non 1
wowen geotextile
Backfill
Reinforced soil wall
(Gabion fascia mesh size
10x12, 2.7/3.7 mm wire ø, Toe Drain
ZINC+PVC coated)
Non-woven Geotextile
0.08(Typ.)
H1
Berm
Structural Fill
6°
Detail- A Drainage
Composite
BIS Certified High
Strength Geogrid
H
Toe Drain
Detail- B
In-Situ Strata
Min. 1.0m
Embedment 100mm Thick PCC
TYPICAL CROSS SECTION OF REINFORCED SOIL STRUCTURE
Drawing Title:
LAND SLIDE MITIGATION AT CORTALIM GOA Client: PWD GOA Drawing No: SHEET 2 OF 3
Project:-
CONCEPTUAL SCHEME ONLY HILL SIDE SLOPE PROTECTION MEASURES AT NH 66 NEAR CORTALIM (SANTRANT
Date: 30-05-2025 N.T.S
NOT FOR CONSTRUCTION SLOPE AND FERRY POINT) IN THE STATE OF GOA
Gabion
1.0
Non woven geotextile
0.08
(Typ.) Geogrid
Primary Reinforcement
( Length As Per Design )
12mm dia connector rod
DETAIL-A
Draining core
0.75 Non Woven Geotextile on
both sides
0.54
0.10
0.40 Transverse Half Perforated PVC Pipe
160mm Ø Wrapped With Geotextile 2%
0.34 Slope @ 10m C/c
Longitudinal Half Perforated PVC Pipe
0.50
160mm Ø Wrapped With Non Woven
DETAIL OF TOE DRAIN Geotextile
DETAIL-B
Drawing Title:
TYPICAL DETAIL Client: PWD GOA Drawing No: SHEET 3 OF 3
Project:-
CONCEPTUAL SCHEME ONLY HILL SIDE SLOPE PROTECTION MEASURES AT NH 66 NEAR CORTALIM (SANTRANT
Date: 30-05-2025 N.T.S
NOT FOR CONSTRUCTION SLOPE AND FERRY POINT) IN THE STATE OF GOA