0% found this document useful (0 votes)
79 views3 pages

Control - Codes XTA

The document provides diagnostic and utility codes for XTA Electronics Ltd.'s 4 Series and 5 Series units, detailing specific key combinations for various functions such as battery fail checks, alignment, and card programming. It includes cautionary notes regarding the output levels during alignment mode. Additionally, it outlines card copying procedures and security setup instructions.

Uploaded by

Orlando Alvarado
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views3 pages

Control - Codes XTA

The document provides diagnostic and utility codes for XTA Electronics Ltd.'s 4 Series and 5 Series units, detailing specific key combinations for various functions such as battery fail checks, alignment, and card programming. It includes cautionary notes regarding the output levels during alignment mode. Additionally, it outlines card copying procedures and security setup instructions.

Uploaded by

Orlando Alvarado
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Information

XTA Electronics Ltd.


The Design House
Vale Business Park
Worcester Road
Stourport-on-Severn
Worcs. DY13 9BZ. England
Tel: 01299 879977 (Intl. +44 1299 879977)
Fax: 01299 879969 (Intl. +44 1299 879969)

Diagnostic & Utility Codes for ALL Units


5 Series
As 4 Series except:
Hold BACK on power up: reboot DSP
78B4: Make Program Card (512k card required)

DC1048 and Ti1048


Hold down the [OK] key on start-up:
Battery Fail (Leaves alignments and security): COM GPI, SYS, OK
Program flash device for test: UP, SYS, UP, SYS
Alignment: UP, SYS, DN, OK
Step to next channel: OK
Inc. parameter gain: UP
Dec. parameter gain: DN
Save current settings: SYS
Exit without saving: GPI

4 Series
Hold down the [MENU] key on start-up:
4B13: Battery Fail (Leaves Security and Alignments)
AB12: Generator+
A431: Alignment
ABBA: LED/Switch Test
341B: Clear Xover (Full Range)
1AB4: Make Program Card (512k card required)
2BB2: Make Program and Preset Card (512k)
3AB4: Make Preset Card (256k & 512k)
81D7: Load Jump Flash
2121: Security Access1

CAUTION!! Enabling the Alignment mode will output +18dB at 1kHz on


ALL outputs ! Do NOT remain connected to a PA system during this test!

1
Contact XTA for complimentary break code for 4 Series security.

Diagnostic Control Codes Page1


DP226 [ AND Old DP428 Codes]
Hold down the [MENU] key on start-up:
6B13: Battery Fail (Leaves Security and Alignments)
A456: Alignment
ABCD: LED/Switch Test
81D7: Load Jump Flash
561B: Clear Xovers to Flat
5AB6: Make Program Card (256k & 512k)
2BB2: Make Program and Preset Card (256k & 512k)
3AB4: Make Preset Card (256k & 512k)
152A: Outputs 100Hz @ -40 (DP226 Only)

CAUTION!! Enabling the Alignment mode will output +18dB at 1kHz on


ALL outputs ! Do NOT remain connected to a PA system during this test!

DP224
31B13: Battery Fail (Leaves Security and Alignments)
A4332: Alignment
4A311: Clear Xovers to Flat
1332A: Outputs 100Hz @ -40dB
2BB22: Make Program and Preset Card (256k & 512k)
4AB12: Make Program Card (256k & 512k)
3AB42: Make Preset Card (256k & 512k)

Diagnostic Control Codes Page2


DP324
Alignment: A456 (INP A, LIM A, DEQ B, GATE B)
(Inject +18dB into B and align to lowest number,
then do A followed by all outputs, which will be driven from A)

Battery Fail: 6B13 (GATE B, INP B, DEQ A, COMP A)

Card Copying Procedures


Program Only: 5AB6 (DEQ B, INP A, INP B, LIM B) (256k & 512k)
Preset Only: 3AB4 (COMP A, INP A, INP B, LIM A) (256k & 512k)
Program and Preset: 2BB2 (GATE A, INP B, INP B, GATE A) (256k & 512k)
Preset Only from User Mems: 6663 (GATE B, GATE B, GATE B, C OMP A)

Set Option Code (Complete Access): AB12 (INP A, INP B, DEQ A, GATE A)
(Start with the ‘Next’ key and work around the unit in button order to open up full
TC’s etc. Note: ‘Enter’ key confirms and ‘Quit’ key quits.)
Next: 0000.0000.0000.0001 = Opens up all release time stops
Back: 0000.0000.0000.0010 = Turns on memories storing bypass status
Quit: 0000.0000.0000.0100 = Turns on memories storing user mode status

Security Set-up: 8713 (LIM B, COMP B, DEQ A, COMP A)


(Hold down [ENTER] and turn on to access Security set-up)

CAUTION!! Enabling the Alignment mode will output +18dB at 1kHz on


ALL outputs ! Do NOT remain connected to a PA system during this test!