Details of the network modules installed on the core switch?

PDU – Fiber Modules – RPS

Port utilization status on both the core and access switches ?

On the Lusail core switches all ports 48 are utilized

And on the rest of the access switches information are not clear on Port utilization status

PoE requirements (PoE, PoE+, or PoE++)?

It will be as Per the new design but the 802.3af, 15.4W/port) is sufficient (no need for
PoE+/PoE++)

Uplink speed, media type (Multimode or Single mode), and transceiver connector type?
Based on the site area, I recommend using Multimode SFP in the three branches.

Number of IDF locations per building


Lusail : 13 IDF
Legtaifiya:3 IDF
Hilal :1 IDF

Number of switches planned per IDF ?

As we don’t have the correct floor plan where of users and PoE devises connected to IDFs, we
will stick to same number of switches per IDF that they provided, later on changes can be made
depending on the Clint need and use and budget

Requirement for redundant power supplies?

As it depends on the design, 2 power supplies are recommended