0% found this document useful (0 votes)
456 views23 pages

GONSIN TC-902/904/906/908 User Manual

The document provides information on the TC-902/904/906/908 infrared simultaneous interpretation system. It includes a 3-page general description of the system components including the infrared transmitter, infrared radiator, infrared receiver, and interpreter console. It then provides detailed specifications and descriptions of the interpreter console over 4 pages covering its main features, technical data, function keys, and operation for direct and relay interpretation.

Uploaded by

maka153
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
456 views23 pages

GONSIN TC-902/904/906/908 User Manual

The document provides information on the TC-902/904/906/908 infrared simultaneous interpretation system. It includes a 3-page general description of the system components including the infrared transmitter, infrared radiator, infrared receiver, and interpreter console. It then provides detailed specifications and descriptions of the interpreter console over 4 pages covering its main features, technical data, function keys, and operation for direct and relay interpretation.

Uploaded by

maka153
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TC-902/904/906/908 Infrared Simultaneous Interpretation System

User Manual

TC-902/904/906/908 IR SYSTEM

USER MANUAL

TABLE OF CONTENTS
Safety Instructions p3 General Description p4 Interpreter Console p5 Infrared Transmitter p10 Infrared Radiator p12 Infrared Receiver p14 Interpreter Headset p18 Delegate Earphone -- p18 Receiver Lanyard p18 Receiver Carrycase p18 Radiator Bracket p19 Radiator Tripod p19 Interpreter Cable p19 Radiator Cable p19 Radiator Mounting p20 Configuration Diagram p21 System Connection p22 System Testing p22 Limited Warranty p23

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Important Safety Instructions


1. Follow all instructions. 2. Do not block any ventilation openings. 3. Do not place the apparatus on an unstable surface, near water or heat source. 4. Use only the power cord that comes with the apparatus. or electric shock. 5. Use only the type of power source indicated on the apparatus and always supply power directly from a standard domestic electric outlet with the AC power cord that meets the relevant local safety standards. 6. Connect all equipment to properly grounded power outlets. Avoid using outlets on the same Use of another cord may result in fire

circuit as photocopiers or air control systems that regularly switch on and off. 7. Protect the power cord from being walked on or pinched. 8. Unplug the apparatus during lightning storms or when unused for long periods of time. 9. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has

been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the unit, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

TC-902/904/906/908 IR SYSTEM

USER MANUAL

General Description
GONSIN TC-902/904/906/908 infrared system is designed to offer simultaneous interpretation and wireless audio distribution for up to 1, 3, 5 or 7 different languages plus the floor language using the proven, state-of-the-art infrared light transmission technology.

As the central element of the system, the infrared transmitter interfaces with either analog or digital discussion system, connects to the interpreter consoles and the infrared radiators which transmit audio signals to wireless multi-channel receivers for the delegates to hear the language of their choice via personal earphones.

The system operates in the higher 2 MHz to 6 MHz frequency band, immune to distortion from hall lighting and free from outside radio frequency interference.

As infrared signals do not pass through walls and ceilings, the system is secure to use. applications can run simultaneous in different rooms without interfering with one another.

Multiple

The system complies with the relevant ISO, IEC, CE standards/requirements and is ideally suited for use in business and government conferences, international conventions and other multilingual applications.

Typical Applications

Convention centers Boardrooms Auditoriums

Parliament chambers City councils Theatres

Courtrooms Classrooms Churches

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Interpreter Console
Model No. TC-F06/16

Main Features:
Digitally-controlled unit for single interpreter. Designed to comply with IEC60914/CE standards & requirements. Handles simultaneous interpretation for 6/16 different languages. Supports direct interpretation and relay interpretation. Function keys with corresponding LED indicators. LCD screen to display the following information: 1) Specific settings for the interpreter unit. 2) Incoming/outgoing language channel number. 3) All the occupied language channels. 4) The language channel occupied by the present unit. 5) Interpretation time from the beginning to the end. 3 incoming languages can be preset, with pre-select A/B/C keys. FLOOR key can be pushed to return to the incoming floor/original channel setting. Left/Right < > keys for incoming channel selection. Left/Right < > keys for outgoing channel selection. Two different types of microphone can be used: 1) Highly directional electret condenser, pluggable microphone with red ring luminant to

TC-902/904/906/908 IR SYSTEM

USER MANUAL

identify the active unit. 2) Combined headset microphone which can be adjustable for comfortable wearing. Built-in loudspeaker with volume level control. The selected incoming language channel is heard when the microphone is switched off. Automatic channel interlocking function prevents the interpreters from using the same outgoing channel. MUTE (cough cut) key for muting the microphone to prevent any unwanted sound/noise such as cough. SLOW key to alert the current speaker to speak slowly. When the key is pushed, a message will be sent to the speaker and the red ring luminant will flash. 3.5mm REC output jacks on both sides to connect the recording device. Multiple interpreter consoles can be connected in a daisy-chain to the IR transmitter or control unit.

Technical Data:
Frequency response: 50Hz-18kHz Distortion at 1 kHz: <0.1% Channel separation: >85 dB Signal-to-noise ratio: >90 Db Max. input power level: 7.5V Input impedance: 2k ohms Operating voltage: 24V Standard microphone stem length: 425 mm 128x64 graphic backlit LCD screen 3m/5m/10m cable with DB25 connectors 6 x 3.5mm jacks for microphone, recorder, headphone ABS base dimensions: 247X145X95mm (WDH)

TC-902/904/906/908 IR SYSTEM

USER MANUAL

22 21 20 19 18 17 16 15 14

2 1 3 4 5 6 7 8 9 10

13 12 11

Descriptions for the function keys and indicators


1) 2) 3) 4) 5) 6) A/B/C monitoring channel switch keys for a pre-select incoming language. LED indicators for the pre-select A/B/C monitoring language channel. Left/Right < > keys to select the incoming language channel for relay interpretation. LED indicator for the relay interpretation channel. LED indicator for the floor/original interpretation channel. FLOOR key for the floor/original language channel. pushed to access the floor signal. 7) MUTE key: holding down the key to enable a brief muting of the microphone which will be
7

The indicator will light up when the key is

TC-902/904/906/908 IR SYSTEM

USER MANUAL

active again when the key is released. 8) 9) LED indicator for MUTE function MIC on/off key: when the key is pushed to switch on the microphone, the mic indicator and the red ring luminant on the pluggable microphone will light up. When the key is pushed to switch off the microphone, all the delegate receivers will be automatically switched to original language channel. 10) SLOW key to alert the current speaker to speak slowly. When the key is pushed, a message

will be sent to the speaker and the microphone red ring luminant will flash for some seconds. 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) Headphone output jack (3.5mm) on both sides Microphone input jack (3.5mm) on both sides REC output jack (3.5mm) to connect an audio recorder Rotary switch for master/headphone volume level control LED indicator for SLOW function LED indicator for microphone on/off Left/Right < > keys to select an outgoing channel XLR connector for pluggable microphone LCD screen LED indicator for the left MIC jack. used. 21) MIC input key, which can be pushed to select the use of pluggable microphone or left/right MIC input jacks. 22) LED indicator for the right MIC jack. jack is used. The indicator will light up when the right MIC output The indicator will light up when the left MIC input jack is

Setting an Outgoing Channel


Only one outgoing channel can be selected for interpreted language. Push the Left/Right < > keys to select an outgoing channel. The selected channel number will flash on the LCD for 3 seconds. selected.
Displays outgoing channel; displays the selected channel; displays the occupied channel.

Any occupied channel will be bypassed automatically when it is

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Direct Interpretation & Relay Interpretation


When the FLOOR key is pushed to monitor the floor language channel for direct interpretation, Left / Right < > keys are invalid.

For relay interpretation, A/B/C monitoring channel switch keys and Left / Right < > keys can be used to select a language other than the floor language. The RELAY indicator will light up when the relay interpretation is operated.

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Interpretation Time
displays the total time for the present interpretation displays the total time for the previous interpretation

Infrared Transmitter
Model No. TC-Z902V/904V/906B/908

The TC-Z902V/904V/906B/908 infrared transmitter is a microprocessor based central unit which is designed to modulate and transmit 2, 4, 6 or 8 sound channels to different carrier frequencies. It features built-in IR test diodes for audio monitoring and testing of receivers, built-in automatic level control (ALC) to ensure comfortable listening levels, independent channel output level LED indicators, and independent channel audio output sockets for sound recording. frequency tone for each input/channel. Test mode produces a different Two BNC sockets can link up infrared radiators in two lines.

Modulation mode: FM Frequency synthesis: digital PLL Frequency band: 2.0 MHz - 6.0MHz Frequency response: 100HZ-14KHZ Frequency stability: 10ppm Pre-emphasis: 75 Sec. 10

RF output impedance: 55-75 ohms Input impedance: 18k ohms Max. input power level: 7.5V AGC range: 30dB S/N ratio: >75dB Power consumption: 40W

TC-902/904/906/908 IR SYSTEM Peak deviation: 7.5kHz Distortion at 1 kHz: <0.5% Channel separation: >70dB RF output power level: 700mV

USER MANUAL Power requirement: 110/220VAC, 50/60Hz 19" rack mountable case Dimensions: 43099325 mm (WHD) Weight: 7.6 kg

FRONT PANEL 1 2 POWER LEVEL INDICATORS Power ON/OFF switch and indicator Output level LED indicators for each audio channel

REAR PANEL 3 4 5 6 7 8 AUDIO IN TEST INTERPRETER UNIT AUDIO OUT SIGNAL OUT POWER INPUT Unbalanced RCA audio input sockets (CH 0,1,2,3,4,5) ON/OFF switch for channel signal testing of receivers. Female DB25 port to connect male DB25 port on interpreters units rear panel. Unbalanced RCA audio output sockets (CH 0,1,2,3,4,5) RF output BNC socket to connect the radiator AC power input socket (110/220V, 50/60Hz)

11

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Infrared Radiator
Model No. TC-H15/25

The TC-H15/25 high-power infrared radiator is able to produce an average transmission output of 15watts/25watts and can be switchable to 50% low power, making it suitable for use in larger halls and smaller rooms. The radiators integrated power supply unit is automatically switched on and off by the carrier signals from the transmitter by means of a high frequency sensor. The radiator is equipped with automatic gain control to ensure the infrared diodes function with maximum efficiency, and is naturally convection cooled for totally silent and maintenance-free continuous operation. It can be ceiling or wall mounted for permanent installation, or set up on an optional tripod for portable application. Multiple radiators can easily be daisy-chained together to expand coverage. The unit is easy to maintain and clean, with IR emitting diodes protected by the cover plate.

Frequency band: 2.0 MHz - 6.0 MHz IR output power: 15W/25W Switchable output level: Low/High (50%/100%) Coverage range: up to 20 meters(15W) and 30 meters(25W) RF output impedance: 55-75 ohms RF input voltage: 100-2000mV

Power consumption: 55W / Stand-by 8W Power Supply: 110/220VAC, 50/60Hz Operating temperature: 0-40 Cable: 75-4 coax, BNC connectors Dimensions: 450 211 82 mm (WHD) Weight: 3.8 kg

12

TC-902/904/906/908 IR SYSTEM

USER MANUAL

1 2 3 4 5 6

OUTPUT LEVEL SWITCH TRIPOD HOLE SIGNAL IN SIGNAL OUT POWER SWITCH POWER INPUT

Slide switch for adjusting output level (HIGH 100% / LOW 50%) For mounting radiator on a tripod for portable use RF input BNC socket to connect the transmitter or the last radiator RF output BNC socket to connect the next radiator Power on/off switch and indicator AC power input socket (110/220V, 50/60Hz )

13

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Infrared Receiver with LCD


Model No. TC-J902/904/906LB/908L

The portable TC-J902/4/906LB/908L infrared receiver is designed to receive up to 2, 4, 6 or 8 audio channels. The unit is powered by a more environment-friendly rechargeable Lithium-ion battery pack. The selected channel number and battery level can be displayed on LCD screen. through a thumbwheel switch for comfortable listening. The user may listen to any selected language on a personal earphone. Volume level can be adjusted Any number of receivers can be used within the radiators effective coverage range in an installation.
Modulation mode: FM Frequency synthesis: digital PLL Frequency range: 2 6 MHz Frequency response: 100Hz-14kHz De-emphasis: 75 Sec. Peak deviation: 7.5kHz Distortion at 1 kHz: <1% Signal-to-noise ratio: >55dB Channel separation: >55dBA Frequency stability: 10ppm Power consumption: 50mW Slide switch for power on/off Thumbwheel switch for volume control 3.5mm phone output jack Up/down push buttons for channel selection LCD display for channel number & battery level Pocket clip and lanyard for easy-wearing Integrated charging electronics and contacts Battery: 3.7V rechargeable Lithium-ion LCD screen size: 33 x17mm Dimensions: 1335723 mm (WHD) Weight: 0.15 kg

14

TC-902/904/906/908 IR SYSTEM

USER MANUAL

1 2 3 4 5 6 7 8

OPTICAL LENS LCD SCREEN POCKET CLIP CHARGING CONTACT PHONE JACK VOLUME CONTROL POWER ON/OFF CHANNEL SELECTOR

Infrared light focusing device inside the plastic shield LCD display for selected channel number & battery level Integrated pocket clip for easy-wearing Battery charging contact 3.5mm mini earphone jack Thumbwheel switch for volume control Slide switch for power on/off Up/down push buttons for channel selection

15

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Infrared Receiver without LCD


Model No. TC-J902/904/906B/908

The portable TC-J902/904/906B/908 infrared receiver is designed to receive up to 2, 4, 6 or 8 audio channels. The optical lens offers a wider receiving angle to pick up the infrared light signal. delegate may listen to any selected language on a headphone/earphone. an installation. The Volume level can be

adjusted through the volume control for comfortable listening. Any number of receivers can be used in

Modulation mode: FM Frequency synthesis: digital PLL Carrier frequencies: 2.0 MHz - 6.0MHz Frequency response: 100HZ-14HKZ De-emphasis: 75 Sec. Peak deviation: 7.5kHz Distortion at 1 kHz: <1% S/N ratio: >55dB Frequency stability: 10ppm

Operating voltage: 2.3V-3.6V Power consumption: 50mW Slide switch for channel selection Thumbwheel switch for power on/off & volume control 3.5mm output phone jack Battery type: 2 x AAA alkaline or rechargeable Pocket clip and lanyard for easy-wearing Dimensions: 1405830 mm (L x W x D) Weight: 130g (excluding batteries)

16

TC-902/904/906/908 IR SYSTEM

USER MANUAL

1 2 3 4 5 6

POWER ON INDICATOR OPTICAL LENS PHONE JACK POCKET CLIP POWER / VOLUME CHANNEL SELECTOR

LED indicator will light up when the receiver is turned on. Infrared light focusing device inside the plastic shield 3.5mm mini earphone jack. Integrated pocket clip for easy-wearing Thumbwheel switch for power on/off and volume control Slide switch for channel selection (Ch 0,1,2,3,4,5)

17

TC-902/904/906/908 IR SYSTEM

USER MANUAL

TC-D2 Interpreter Headset


Closed-ear stereo headset with mic and vol control Connectors: 3.5mm stereo plugs Impedance: 6015% Frequency response: 20Hz to 20KHz Input power: 30-50mW Sensitivity (1 kHz): -582dB Microphone type: Omni-directional dynamic Microphone sensitivity (1 kHz): -582dB Cord length: 2 meters

TC-D1 Delegate Earphone


Type: dynamic 40mm 360 swivel clip-on hanger Frequency response: 7Hz to 24KHz Sensitivity: 102dB3dB Impedance: 4010% Input power: 8-50mW 120 cm cord with 3.5mm plug Full range enhance system Super bass frequency technology

RY-123 Receiver Lanyard


Designed for receiver unit s easy wearing Length: 40 cm

GX-48 Receiver Carrycase


Handy locking aluminum/plastic suitcase Designed for carrying/storage of receivers 48 positions with pre-cut foam Dimensions: 503320cm

18

TC-902/904/906/908 IR SYSTEM

USER MANUAL

UA-203 Radiator Bracket


Swivel bracket for wall/ceiling mounting Adjustable angle

GX-315 Radiator Tripod


Type: floor standing, foldable 3-way pan tripod Height: 60cm to 150cm

DB25 Interpreter Cable


25-p male/female parallel cable Length: 3m/5m/10m

75-4-128 Radiator Coaxial Cable


Connectors: BNC type, 2 x male Length: 10 meters

19

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Radiator Mounting

1. Wall mounting routing cables upward

2. Wall mounting routing cables downward

3. Ceiling mounting

4. Floor-standing tripod mounting

20

TC-902/904/906/908 IR SYSTEM

USER MANUAL

System Configuration Diagram

21

TC-902/904/906/908 IR SYSTEM

USER MANUAL

System Connection
CONNECTION
1 2 3 4 Conference System Central Unit Transmitter External Sound System Transmitter Transmitter Interpreter Console Transmitter Radiator

SOCKETS
Audio output AUDIO IN (CH 0) Audio output AUDIO IN (CH 1-5) socket INTERPRETER UNIT port INPUT port SIGNAL OUT (SIGNAL) IN

CABLE
Audio cable Audio cable DB25 shielded cable 75-4 coaxial cable

System Testing
After all the system components are connected, make sure the TEST switch is OFF on the transmitters rear panel. Turn on power for the transmitter and radiators, and then turn on the TEST switch. level indicators on the transmitters front panel will light up. via an infrared receiver. Walk about the conference venue. radiators mounting angle or HIGH/LOW output level. switch to OFF position. The

Listen to the test signal for every channel If there is any blind area, adjust the

After the testing is finished, turn the TEST

Turn on the interpreter microphone, conference system central unit and other audio equipment, and then choose an output channel to see if the signal can be heard via the receiver. Please note: 1) The receivers should be used at least 5 meters away from any radiator. 2) The floor

signal should be connected to the CH0 input socket on the transmitter rear panel. and the radiators should use an external power supply with a ground.

3) The transmitter

22

TC-902/904/906/908 IR SYSTEM

USER MANUAL

Limited Warranty
GONSIN warrants that the hardware products it manufactures will be free from defects in materials and workmanship. The warranty term, beginning on the date of invoice, is one year for parts replacement, two years for parts repair and six months on accessories.

This warranty does not cover damage or failure caused by alterations, mishandling, abuse, misuse, neglect, accident or resulting from any cause other than a product defect.

In case of defects in material and workmanship under normal use and conditions, GONSIN will replace or repair products covered under this limited warranty that are returned to GONSINs facility.

To request warranty service, you must contact GONSIN international sales team within the warranty period, ship the products back to GONSIN in their original or equivalent packaging (freight prepaid). If GONSIN repairs or replaces a product, its warranty term is not extended.

Guangdong Gonsin Digital Equipment Corporation


Factory: 40 Shunxiang Road, Fengxiang Industrial Park, Shunde, Foshan, Guangdong 528300, China. Tel: 86-757-22360969 Fax: 86-757-2238-2370 Email: sales@[Link]