0% found this document useful (0 votes)
57 views1 page

A-02-004 - Right Elevation

The document is a detailed architectural drawing for a proposed residential villa located in Dubai, including various floor plans, dimensions, and design notes. It outlines responsibilities for contractors and consultants, along with general notes on construction practices and coordination. The drawing is intended for building permit purposes and includes contact information for the involved parties.

Uploaded by

urbanartllcae
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views1 page

A-02-004 - Right Elevation

The document is a detailed architectural drawing for a proposed residential villa located in Dubai, including various floor plans, dimensions, and design notes. It outlines responsibilities for contractors and consultants, along with general notes on construction practices and coordination. The drawing is intended for building permit purposes and includes contact information for the involved parties.

Uploaded by

urbanartllcae
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PREVIOUS AUTHORITY APPROVAL / STAMP

A B C D E F G H
Keyplan: PLOT LIMIT
1950 1750

3
5300

1450
4075

1475 1375
E 494969.997
N 2784436.302
A B
BACKYARD PLOT LIMIT
ENTRY
E 494954.252
N 2784455.049
S. SEATING
S. POOL S. POOL

4920
FFL +0.15

3865
1 UP
2
3 SHADED
TEPPANYAKI
DN DN
FFL -0.60 FFL -0.30 FFL +0.30 FFL +0.60 FFL +0.00

5 4 3 2 1 1 2 3

Planter Planter
GF-13
FFL +0.15
OUTDOOR SEATING
6.50 x 3.60m

2350
FFL+0.60

3600
Deck

SHOWER
3025
1

1250
2

FIRST FLOOR PROJECTION


GF-03
SHOW KITCHEN
7.00 x 6.00m
FFL+0.60

3000

CONSOLE

CONSOLE
D D

6250
SETBACK GF-02 KITCHEN ISLAND

LIVING AREA
8.75 x 6.00m

BENCH

SHOW KITCHEN
FFL+0.60
TREADMILL TREADMILL

ELLIPTICAL

3 D04
MEP D06
D07
SHAFT 3000
C C

2000
GF-04 S.ENTRY
LIFT POWDER 4 SETBACK

BAR/WINE CABINET
1.70 x 1.75m 2.3 x 1.75m 3

FRIDGE
FFL+0.60 2
GF-06
4 KITCHEN
1

2 D05 3.70 x 3.50m UP

(SERVICES)
FFL+0.60
GF-05

1750
GF-11 FFL +0.00

DUCT
STAIRCASE WASH
3.45 x 5.70m 1.55 x 1.50m
FFL+0.60 DN GF-01 FFL+0.60
52 1 UP

5 FFL -2.80
27
28
2
51
50
ENTERTAINMENT AREA
5.30 x 7.95m
FFL+0.60
FFL -2.80

17 29 49 17
3
16 30 48 16
4
15 31 47 GF-08 GF-09 15
5
NEIGHBOURING 14 32 COURTYARD
46
WALK-IN BATHROOM 01 14
6 3.60 x 1.90m D03
3.00 x 1.90m SIKKA
PLOT 13 33 45 13

4200
7 FFL+0.60 FFL+0.60
12 34 44 12
8
11 35 43 11
9
10 36 42 10
10 16 D02
9 37 38 39 40 41 9
11 12 13 14 15 GF-07
8 8

1100
BEDROOM 01
7 7
5.27 x 3.00m
6 6
D01 FFL+0.60 GF-10

6 1005 5 TERRACE 5
4 1.47 x 3.15m 4
FFL+0.60
3 FOYER 3
2 2.1 X 1.5 m 2

7 1

4
1

DN DN
3
PLANTER
FFL +0.00 FFL +0.00
2

8 7150 1
3005

1300
FFL +0.00

8265
SHADED PARKING SHADED PARKING

6965

6965
SETBACK
3000
PEDESTRIAN ENTRY

PLANTER VEHICULAR ENTRY PLANTER UTILITY

PLOT LIMIT PLOT LIMIT

Q
E 494993.216 E 494976.550
N 2784459.288 N 2784476.540
A 1 B

ROAD 22.42

N
GATE LEVEL:

Notes:
1. This Drawing is copyright protected
2. Do not scale from the drawing
3. All dimensions shown are in millimeter, and do not take into account applied finishes,
unless specifically indicated otherwise. Any omissions or discrepancies found shall be reported to
the Architect/Engineer immediately.
4. Levels are given in millimeters to three decimal places above survey datum.
5. This drawing should be read in conjunction with approved drawings and other relevant sections of
specifications. Any discrepancies shall be reported to the engineer prior to the commencement of
the work.
6. The contractor is responsible for confirming and correlating all quantities, dimensions, fabrication
progress and techniques of construction and coordinating his work with that of all other trades and
performing his work in a safe and satisfactory manner.

General Notes:
1. These drawings are not to be scaled. Only written dimensions are to be followed.
Any discrepany must be advised to the engineer.
2. All dimensions are metric unless otherwise indicated.
3. The walls are dimensioned to the unfinished face of masonry and / or concrete unless otherwise
noted.
4. Exact dimensions of structural elements to be extracted from structural details.
5. All drawings are to be read in conjunction with other relevant drawings of the same & other
disciplines.
6. Final coordination of construction is the responsibility of the contractor.

Revision:

Rev ID Issue Date Issue Description Approved by

Client:

MR. SHAYAN KHOSHSEPEHR

Architectural Consultants:
Concept by SOWE
Website: www.conceptbysowe.com
Email: [email protected]
Tel: +971 527113740

Structural Consultant & AOR (Architect-Of-Record):


PLANQUADRAT MIDDLE EAST
ARCHITECTS AND ENGINEERS
P.O.Box 117880, Dubai U.A.E.
Tel: + 971 4 261800 / Fax: + 971 4 261 8101

Main Contractor:
ECC FIT-OUT & CONSTRUCTION
P.O.Box 62393, Dubai U.A.E.
Tel: + 971 4 3736777
Fax: + 971 4 3237772

MEP Consultant:
DYNAMIC ENGINEERING CONSULTANT
P.O.Box 825293, Dubai U.A.E.
Tel: + 971 4 2662399
Fax: + 971 4 2662398

Project Title:

PROPOSED B+G+1+R
RESIDENTIAL VILLA

Project Location: Waterfront Type B, District One, Dubai


Plot No.: PP02.026
Design Stage: Concept Design

Drawing Title:

PERSPECTIVE

Drawn by: Checked by: Approved by:


CBS

Purpose of Issue Scale: Date:


BUILDING PERMIT N.T.S. 01/10/2024

Sheet Size: Project No: Drawing No: Revision:


A1 087 A-02-004 -

RIGHT PERSPECTIVE