DAIKIN UK PRODUCT CATALOGUE
1ST FEBRUARY 2009
[Link]
09
N
FO E
R W
20
FBQ-C / FXSQ-P
FCQH-D
5 2AGE
High COP Roundow Cassette
Increased COP/EER
All Roundow cassettes now available with white
louvers
4 4AGE
Air Curtains for Sky Air
CMSQ-A + FMDQ-B - FMCQ-A
Multi system for light commercial applications
Indoors: asymmetric combination and individually
controlled
2-storey application possible
Maximum piping length up to 165m.
6 6AGE
Connects to Super Inverter
Rectier technology with
European Patent
Payback time of less than 2.5
years
70AGE
DC ducted with inverter driven fan
Reduction of power consumption
Automatic air ow adjustment
Improved comfort with 3-step air ow
Hydraulic parts encased in
outdoor unit.
H2O piping between outdoor/
indoor heating appliances
Connectable to underoor
heating, low temp radiators and
fan coils.
Freeze protection of hydraulic
parts
1 4AGE
ALTHERMA MONOBLOC
Ururu Multi
REYHQ-P
VRVIII Inverter Heat Recovery High COP combination
Top energy efciency - redesigned 8HP modular unit
and new 12HP high COP modular unit.
Continuous heating (higher integrated heating
capacity)
PA
13 AGE
0
8 6 GE
RWEYQ-P(R)
Air Curtains for VRV
Connects to entire VRVIII range
Constant Air Velocity technology with European
Patent
Rectier technology with European Patent
Extended Mini-Chiller range
Extended exibility with 1 and 3
phase models
Increased efciency with top
ESEER at part load conditions
Reduced sound pressure levels
Inverter technology
Water-cooled condenserless screw chillers
Ururu Air Purier
22 AGE
0
Cooling range: 161-526kW
DX shell & tube evaporator - one pass refrigerant side
Optimised for use with R-134a refrigerant
Electronic expansion device as standard
Humidication and air purication in one
Deodorising function thanks to the ash streamer
technology
Low noise level ideal for use at night
16 AGE
4
5 air ow volumes - 1750 m3/hr to 9000 m/3hr all
capable of 250 pa external static.
3 distinct groups all available in both Internally
mounted plant room and externally mounted weatherproofed types.
18 AGE
6
EWAQ-AC / EWYQ-AC
Air Handling Units
15 AGE
0
13 AGE
4
Water-Cooled VRVIII
New 8HP unit: 9 combination possibilities upto 30HP
Wide range of connectable indoor units
Improved comfort with new BS-box
Geothermal application possible
22 AGE
8
Maintains comfortable humidity level without
separate water supply
Fresh air supply
Two indoor units connectible and individually
controlled
FOREWORD
DAIKIN the leader in manufacturing quality and customer service
Daikin was founded in 1924 in Osaka, Japan. The company we now know as Daikin Industries Ltd (DIL) is the parent
company of Daikin Europe N.V. (DENV) which was established in Ostend, Belgium in 1972.
Daikin Europe is continuously updating and expanding its manufacturing facilities, to a point where they are now
acknowledged as the most advanced in their eld in Europe. This is backed by zero defect production, efcient supply
chain management and unrivalled research and development support from DIL.
These substantial production facilities are underpinned by a network of wholly owned afliate companies in the UK,
France, Germany, Italy, Spain, Portugal, Poland, Greece, Belgium, Holland and Central Europe. There are also numerous
independent distributors throughout Europe, Africa and the Middle East.
With more than 50 years experience in the production of heat pumps now manufacturing over a million units a year,
Daikin has been at the forefront of the drive for energy efcient heat pump technology. The systems are manufactured
entirely in-house in Daikins state of the art factories this includes the all important energy efcient inverter driven
compressor unit.
As one of many wholly owned afliate companies, Daikin UK is a leading supplier of heating,
cooling and refrigeration solutions for commercial, residential and industrial applications.
Our product portfolio comprises a wide range of highly energy efcient climate control
systems which provides the public and private sectors with the right product for any
application and requirement.
State of the art direct expansion air conditioning
Heat pump residential and light commercial heating, domestic hot water and cooling
Applied central cooling and heating
Medium to low temperature refrigeration.
RESPECT FOR THE ENVIRONMENT
Daikin has an enviable record in concern for environmental
issues and applies it to all areas of the business, implementing
and in many cases pre-empting, international and local
environmental protective legislation.
This commitment is reected in three areas:
1. Reducing waste in manufacturing and operations,
2. Recycling materials and equipment,
3. Designing and producing energy-efcient climate control equipment.
Reducing waste and recycling
At the Factory
s 7ASTEWATER IS TREATED BEFORE BEING DISCHARGED INTO THE CITY DRAINAGE SYSTEM
with the recovered sludge being a useful ingredient in cement manufacturing.
s /THER WASTE IS ALSO CAREFULLY SORTED AND RECYCLED SUPPORTED BY A CONTINUALLY
evolving factory layout that encourages the optimum use of resources.
s 2ETURNABLE PACKAGING IS INVESTED IN WHERE POSSIBLE
s )3/ APPROVED FOR QUALITY MANAGEMENT
s )3/ APPROVED FOR ENVIRONMENTAL MANAGEMENT
In the UK
s )3/ APPROVED FOR QUALITY MANAGEMENT
s )3/ APPROVED FOR ENVIRONMENTAL MANAGEMENT
s !LL PRINTED SALES LITERATURE IS MADE USING RECYCLED &3# CERTIlED PAPER AND PRINTERS
Recycling Equipment
Daikin UKs unique recycling service takes this commitment to the environment one step
further. Despite the WEEE directive 2002/96/EC not currently including xed air conditioning,
when installing Daikin equipment you can arrange for up to 95% of the redundant equipment
to be reprocessed by an authorised WEEE recycler.
Once collected from site, the end of life air conditioning equipment will be transported
to a recycling facility, where it is dismantled in such a way that any hazardous substances
are destroyed or reprocessed. This service is available to all installers of Daikin equipment,
regardless of the manufacturer of the redundant units.
Energy efcient climate control equipment
Our products reect the concept of combining maximising energy efciency with maximum respect for the environment.
Their utilisation of heat pump technology for example, results in far lower energy consumption and in the case of heating,
drastically lower CO2 emissions are achievable than with fossil fuel burning systems. Also their incorporation of numerous
detailed features such as inverter control, heat recovery, economy operating modes, movement sensors among others,
enhance user comfort without compromise to either efciency or the environment.
W Ofce locations
W Training Centre locations
London Head Office
Birmingham Office
Glasgow Office
Daikin Airconditioning UK Limited
The Heights, Brooklands, Weybridge,
Surrey KT13 0NY
Tel 0845 6419300
Daikin Airconditioning UK Limited
Unit 8, Holly Park, Spitfire Road,
Birmingham, West Midlands B24 9PB
Tel 0845 6419370
Daikin Airconditioning UK Limited
Unit 2, Glasgow Airport Business Park
Marchburn Drive, Paisley PA3 2SJ
Tel 0845 6419330
Bristol Office
Manchester Office
South Coast Office
Daikin Airconditioning UK Limited
Maple House, Brotherswood Court,
Great Park Road, Almondsbury,
Bristol BS32 4QW
Tel 0845 6419320
Daikin Airconditioning UK Limited
Quay Plaza, Unit G35, Salford Quays,
Manchester M50 3AG
Tel 0845 6419340
Daikin Airconditioning UK Limited
7 Tabernacle Walk, Blandford,
Dorset DT11 7DL
Tel 0845 6419380
Daikin UK, Weybridge Head Ofce
TABLE OF CONTENTS
Energy Labelling
HEATING
Altherma
Altherma Monobloc
9
14
REFRIGERATION
Conveni-pack
17
AIR CONDITIONING
Air Curtain
Connection to VRV
150
Ventilation
HRV - Heat reclaim ventilation
Outdoor air processing unit
Air Handling applications
158
160
162
Control Systems
Individual control systems
Centralised control systems
Network Solutions
176
177
178
APPLIED SYSTEMS
Residential & Commercial
Wall mounted units
Flexi type units
Floor standing units
Concealed ceiling units
Cassette units
4-Way blow ceiling suspended cassette
Ceiling suspended units
Rooftop
24
36
38
42
50
59
60
65
Air Curtain
Connection to Super Inverters
66
Ururu air purier
Photocatalytic air purier
Commercial Multi System
Commercial Multi System (CMS)
70
OTHER
Twin, Triple, Double Twin
& Multi Application
Twin, Triple, Double Twin applications
Multi model applications
80
86
VRV
VRV 25 years
VRVIII air-cooled outdoor units
VRV-WII water-cooled outdoor units
Indoor units
122
124
132
136
Air-cooled / Remote evaporator
Water-cooled
Remote condenser / Condenserless
D.I.C.N. (Daikin Integrated Chiller Network)
EHMC
Fan coil units
186
209
219
223
224
226
AIR PURIFIER
Power Supply
Measuring Conditions
Explanation of the pictogrammes
229
230
232
232
233
ENERGY LABELLING
Energy labelling is part of a wider European Climate Change program that targets energy
efciency as one method of reducing CO2 emissions in order to meet the targets of the
Kyoto protocol. By this means the European Commission hopes that improved awareness
will result in customers purchasing the most economical (ecological) answer to their needs.
What?
The energy label provides information on the energy
consumption of the unit. Air conditioning units (with cooling
capacity 12kW) are classied in seven different categories
(A to G), according to their energy consumption and color
coded according to the category to which they belong.
The most energy efcient units will be included in the A
category, indicated by a green arrow on the label less
efcient units will belong in G class, indicated by a red arrow
on the label. The end user can easily compare the efciency
of equal types of units from different brands.
Energy
Manufacturer
Outside unit
Inside unit
0RUHHIFLHQW
A
B
C
D
E
The label?
What is mentioned on the label?
Logo and name of manufacturer; name of indoor and
outdoor unit (*)
G
/HVVHIFLHQW
$QQXDOHQHUJ\FRQVXPSWLRQ
N:KLQFRROLQJPRGH
Energy efciency class of the unit
in cooling mode:
(Actual consumption will
depend on how the apliance is used
and climate)
&RROLQJRXWSXW
Energy eIFLHQF\ ratio
EER > 3.20
_ EER > 3.00
3.20 >
_ EER > 2.80
3.00 >
_ EER > 2.60
2.80 >
_ EER > 2.40
2.60 >
_ EER > 2.20
2.40 >
_ EER
2.20 >
N:
Full load (the higher the better)
7\SH
Cooling only
Cooling + Heating
Air cooled
Water cooled
+HDWRXWSXW
N:
+HDWLQJSHUIRUPDQFH
A: higher
G: lower
Noise
(dB(A) re 1 pW)
Further information is contained
in product brochures
Air-conditioner
Energy Label Directive 2002/31/EC
Indicated annual energy consumption
This gure indicates the approximate amount of energy consumed per year by the unit, based on a standard household
model. The annual consumption is calculated by multiplying the total power input by an average of 500 hr per year
IN COOLING MODE AT FULL LOAD.
In order to calculate the cost of annual energy consumption, you merely multiply this gure by your electricity tariff.
Cooling output
Cooling output is dened as the cooling capacity in kW of the appliance, operating in cooling mode at full load. It is
important to choose an air conditioning unit with a rated output sufcient for your cooling/heating requirements. An
oversized unit can result in frequent on/off cycling, which shortens its service life - an undersized unit will not provide
adequate cooling/heating. To determine the appropriate output, contact the manufacturer or your local dealer/installer.
Energy Efciency Ratio (EER)
This is the cooling output of the unit divided by the amount of electricity the unit requires to deliver it (total power input).
In other words, the higher the EER, the greater the energy efciency.
Type
TYPE OF UNIT: it indicates if the unit is a cooling only or cooling/heating system
COOLING MODE: it indicates if the unit is air cooled or water cooled
Heating output
Heating output is dened as the heating capacity in kW of the appliance, operating in heating mode at full load.
Energy efciency class of the unit in heating mode:
A
COP > 3.60
_ COP > 3.40
3.60 >
_ COP > 3.20
3.40 >
_ COP > 2.80
3.20 >
_ COP > 2.60
2.80 >
_ COP > 2.40
2.60 >
_ COP
2.40 >
Noise level: only for portable units.
(*): For multi-models Daikin chooses only to mention 1 outdoor unit with a maximum of 2 indoor units
(wall mounted type) - for other units we refer to the multi brochure.
Air Source Heat Pump
ALTHERMA... Tomorrows Solution Today!
Altherma is safe, reliable, highly efcient and a true low carbon, low cost solution for home heating and hot water. Altherma
heats up to 5 times more efciently than a traditional heating system based on fossil fuels or electricity. By making use of the
heat in the outside air it uses much less energy, whilst still providing year round comfort.
Altherma is a split system consisting of an outdoor unit and an indoor hydro-box that can be connected to all standard low
temperature radiators and underoor heating systems. As maintenance requirements are minimal, running costs are low.
Inverter technology means energy savings are even greater.
COP (Coefcient of Performance)
The COP is dened as the ratio of output energy in Kilo
Watts (kW) and the input energy Kilo Watts (kW). The higher
the COP is, the more efcient the system. The Altherma
heat pump boiler has a COP of 3 to 5, which means that the
pump delivers 3 to 5 times more energy than it uses. From
1 kilowatt of electricity Altherma produces 3 to 5 kilowatts of
available heat.
Flexible congurations
Altherma can be congured for use in both new and
refurbishment applications and connects to standard low
temperature radiators, under oor heating or fan coil units.
If you already have a heating system, you dont need to
change everything.
Complete comfort for the family
Altherma not only satises heating and domestic hot water
requirements, it also comes with a cooling option.
Minimal installation cost
Altherma takes heat from the air. No digging or excavation
works are required. Both the outdoor and indoor units are
compact. The external unit can be located easily outside any
building, including apartments. Without ames or fumes,
there is no need for a chimney or constant ventilation in the
room, where Althermas indoor unit is installed.
Absolutely safe
Altherma doesnt need oil, gas or other hazardous substances.
Moreover, you dont need a gas connection or a fuel tank.
No risk of intoxication, smell or pollution from leaking tanks.
HOW THE SYSTEM WORKS
1
The heat pump extracts heat
from the outside air
Altherma uses a natural, renewable source of
energy air.
The system raises this heat
to a higher temperature
The indoor hydro unit heats the water that
circulates through your low temperature radiators,
floor heating systems or fan coil units and provides
you with domestic hot water.
The outdoor unit derives heat from the surrounding
air and raises its temperature until it is high enough
to heat a home. This heat is then transmitted to the
indoor unit through heat transfer fluid.
The compact outdoor unit is easily installed and can
also be used in properties without a garden.
If the user opts for the combination of heating and
cooling, then the indoor unit can also decrease
the water temperature to distribute a refreshing
coolness.
3
3
2
4
4
10
This heat is then distributed
throughout the home via
heating units...
Underfloor heating
...and to the bath, shower
and sinks
A purpose built stainless steel water tank,
constructed to maintain the highest levels of energy
efficiency, is available to meet domestic hot water
needs. The combination of an electric booster heater
in the upper part of the tank and a heat pump
exchanger in the lower part ensures the lowest
possible energy consumption with rapid water
heating. In addition, a built in function raises the
water temperature to 70C or higher at least once a
week to remove any possibility of legionella growth.
Underfloor heating is possibly the best solution for
new installations. It provides the following benefits:
s Maximum comfort due to radiated heat
s Maximum efficiency compared to other
heat emitters
s Unobtrusive i.e. no wall space required
s Water flow temperatures typically 35 to 40C.
s Seasonal COP typically 3.5 to 4.5
Radiators
Traditionally used as the costs are relatively
inexpensive compared to other systems. The main
benefits for the radiator system are:
s Traditional heating solution
s Low capital cost
s Water temp typically 50C with heat pumps
(radiators must be sized accordingly)
s Seasonal COP with weather compensation
typically 3.0 to 3.5
Optional Solar Kit
The Altherma System can be perfectly combined
with solar collectors to produce hot water. The sun
provides 30 to 70% of the energy required for our
hot water needs. Altherma, your total solution,
thinks of the future.
Fan coils
These systems are more diverse in that they can
provide both heating and cooling if required.
Benefits include:
s
s
s
s
Able to heat and cool
Cased or concealed units
Individual control
Water flow temperatures typically 35C heating
7C for cooling option
s Seasonal COP heating typically 3.5 to 4.5
11
ALTHERMA CONTROLS
Smart temperature regulator
The control system which operates Altherma is built into the casing of the indoor unit and is very
simple to use. With this integrated control, it is possible to regulate the heating according to
the needs of the user. It is easy to set up a full weekly programme and in this way, temperature
is reduced automatically at night or during holidays and increased when the user gets up or
returns home.
The system can also be combined with additional temperature regulating systems with separate
thermostats for living rooms, bedrooms, etc.
Weather compensation
Whatever the temperature outside Altherma optimises the temperature inside. Altherma has
weather compensation built into its integrated control system, allowing it to minimise energy
input to achieve optimum temperature conditions. Compared to most systems Altherma
will be more efcient and will cost less to use. Altherma has weather compensation built in
as standard.
Room Thermostat
With the wired or wireless room thermostat, the ideal temperature can be easily, quickly and
conveniently regulated. As an option to the wireless room thermostat, an external sensor
(EKRTETS) can also be placed between the under oor heating and the oor. It allows for more
precise measurement and can regulate the comfort level of your customer even more optimally
and energy efciently.
EKRTW: wired wall-mounting room thermostat
EKRTR: wireless room thermostat.
EKHBH(X)-A*
INDOOR UNIT (HYDRO BOX)
&UNCTION
4O USE WITH
$IMENSIONS
,EAVING 7ATER
4EMPERATURE 2ANGE
(X7X$
HEATING
COOLING
MM
#
#
EKHBH008AA***
EKHBX008AA***
(EATING ONLY
2EVERSIBLE
%2(1^!$
XX
XX
^
^
EKHBH016AB***
(EATING ONLY
XX
9ES
%POXY POLYESTER PAINTED GALVANIZED STEEL
2!, NEUTRAL WHITE
$RAIN VALVE
-ATERIAL
#OLOUR
EKHBX016AB***
2EVERSIBLE
%2(1^!!
XX
^
*** Hydro Box with Factory Mounted Electric Heater
FACTORY MOUNTED ELECTRIC HEATER
Power supply
Capacity steps
Heating Only
%+("(!!6
%+("(!!6
%+("(!!7.
6 3INGLE 0HASE
6 3INGLE 0HASE
6 4HREE 0HASE AND .EUTRAL
K7 STEP
K7 STEP
K7 STEP
Reversible
%+("8!!6
%+("8!!6
%+("8!!7.
6 3INGLE 0HASE
6 3INGLE 0HASE
6 4HREE 0HASE AND .EUTRAL
K7 STEP
K7 STEP
K7 STEP
12
ERHQ-AD
ERHQ-A
OUTDOOR UNIT
ERHQ006AD
ERHQ007AD
ERHQ008AD
ERHQ011A
ERHQ016A
ERHQ011AW1 ERHQ014AW1 ERHQ016AW1
(X7X$
MM
.OMINAL CAPACITY
(EATING
K7
#OOLING
K7
.OMINAL INPUT
XX
ERHQ014A
$IMENSIONS
XX
XX
(EATING
K7
#OOLING
K7
#/0
%%2
/PERATION RANGE
(EATING
^
^
^
#OOLING
^
^
^
(OT WATER
^
3OUND 0RESSURE LEVEL (EATING
D"!
#OOLING
D"!
7EIGHT
2EFRIGERANT CHARGE
2
!
KG
KG
0OWER 3UPPLY
^ 6(Z
2ECOMMENDED FUSES
Nominal Capacity and Power Input based on the following conditions:
Heating Ambient 7 oCDB/6 oCWB / Leaving Water Temp. 35 oC (DT 5 oC)
^6(Z
Cooling Ambient 35 oC / Leaving Water Temp. 7 oC (DT 5 oC)
OPTIONS
%+("$0