0% found this document useful (0 votes)
59 views5 pages

API 650 Storage Tank Design Checklist

Uploaded by

Haseeb Sardar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views5 pages

API 650 Storage Tank Design Checklist

Uploaded by

Haseeb Sardar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

API 650 Storage Tank Design Checklist

1. General Requirements

- Determine applicable edition and addenda of API 650.

- Define tank service: product stored, temperature, pressure, and volatility.

- Confirm tank type: atmospheric pressure (<=2.5 psig).

- Check if additional standards apply (e.g., API 620, ASME, AWWA, UL).

2. Design Data

- Tank diameter and height

- Design liquid level (including freeboard)

- Specific gravity of stored product

- Design temperature range

- Corrosion allowance

- Seismic zone classification

- Wind load data

- Snow/ice load (if applicable)

- Foundation type and soil bearing capacity

3. Materials Selection

- Select materials per API 650, Table 4-1 to 4-6 (Group I, II, III).
API 650 Storage Tank Design Checklist

- Shell plate material and thickness

- Bottom plate material

- Roof plate and framing material

- Nozzle and manway materials

- Ensure material compatibility with stored fluid

4. Bottom Design

- Bottom plate thickness and layout

- Annular plate ring (if required per 5.5)

- Sketch of bottom weld layout

- Slope (typically 1:120 minimum for drainage)

5. Shell Design

- Calculate minimum shell thickness using 1-Foot method or Variable Design Point Method

- Verify minimum thickness per API Table 5-2

- Wind girders and shell stiffeners (if required)

- Shell courses layout and welding sequence

6. Roof Design

- Determine roof type: Cone, Dome, or Floating roof


API 650 Storage Tank Design Checklist

- Roof plate thickness

- Roof support structure (rafters, girders, columns)

- Check design for snow and wind load

- Roof-to-shell junction design (welded or bolted)

7. Nozzles, Manways, and Appurtenances

- Sizes and locations of nozzles (inlet, outlet, overflow, vent, drain)

- Reinforcement pads as per Section 5.7

- Manways and access hatches

- Shell and roof penetrations

- Anti-vortex plates, ladders, platforms

8. Design for External Forces

- Wind load design (Section 5.11)

- Seismic design per Appendix E

- Settlement and soil bearing capacity

- Anchoring requirements (if uplift occurs)

- Overturning and sliding checks

9. Welding and Inspection


API 650 Storage Tank Design Checklist

- Weld types and details per Section 3

- Inspection requirements (RT, UT, MT, VT) - Section 8

- Hydrostatic test requirements - Section 7.3

- Weld maps and procedure qualifications

10. Corrosion Protection and Coatings

- Corrosion allowance per service

- Cathodic protection (if required)

- Internal and external coating/lining

- Paint system specifications

11. Ventilation and Pressure Relief

- Design of venting per API 2000

- Emergency venting (overpressure/vacuum protection)

- Flame arrestors (if required)

12. Drawings and Documentation

- General arrangement drawing (GAD)

- Tank fabrication drawing (shell courses, roof, bottom layout)

- Nozzle schedule and details


API 650 Storage Tank Design Checklist

- Welding procedure specifications (WPS)

- Material test certificates (MTC)

- Inspection & Test Plan (ITP)

- Hydrotest report

13. Optional Features

- Foam chambers / fire protection systems

- Internal floating roof seals

- Liquid level gauges

- Water draw-off nozzles

- Roof drainage system