Vaginal tightening LASER SYSTEM

(User’s Manual)
Contents
Chapter 1 Product structure
Chapter 2 Accessories list
Chapter 3 Product informaion
Chapter 4 Direction of use
Chapter 5 Operation
Chapter 1 Product structure

Labels:

Laser danger

CE Label
Chapter 2 Accessories list

CO2 main unit Guide light arm Power cord

Key Foot switch Fractional laser head

Vaginal tightening head pulse head


Chapter 3 Product information
1. Principle:

Vaginal tightening laser is the use of water uptake 10600nm gold standard laser,
using a three-dimensional lattice technology and 360-degree circular emission
perfect combination of technology, to produce 50-70 degrees Celsius in a controlled
depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn
fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as
to achieve vaginal wall thickening and tighteningof the vagina so that firmness,
sensitivity enhancement, vagina tight as ever.
Vaginal tightening laser does not produce skin burns due to high temperature, each
capable of Homogeneous heat, acting on a few hundred nanometers thickness
Mucosa organization.

2. Application
thermal radiation make Mucosa tissue contraction and collagen fibers thereby
improving and restructuring vaginal tightening.
1. Shrink vagina: rapid tightening, constriction, lasting firmness.
2. Beautify vagina: dilute pigment, pink labia.
3. Moist vagina: increase secretion, eliminate dryness.
4. Maintenance vagina: deep rejuvenation, prevent aging.
5. To improve sensitivity.
6. Private health, balance PH, improve the internal environment.

3. Specification
Wavelength: 10600nm
Laser apparatus: Sealed off laser device simulated by direct current
Optical beam quality: TEM00
Output power: 60w
Spot size: 0.02~0.05mm2
Aiming beam: Red semiconductor laser (635nm, less than 5mw)
Beam transport device: Articulated arm with 7-joint and balance weight
Working mode: Continuous operation
Output Mode: Continuous, single pulse, interval pulse and super pulse
Scan scope: Max 20mmx20mm
Scan graphics: Circle, triangle, square, rectangle,hexagon, ellipse, line
Scanning Mode: Random , Normal and Midsplit scan
Scanning speed: More than 10m/s
Energy: 1- 60W
Distance: 0.1-2.6mm
Cooling system: air circulation
Weight: 60kg
Dimension: 65*48*117cm
Power: 220V/110V

Chapter 4 Direction for Use


1. Every parts name.
1
2

6
1. joints of seven light guide arm
By seven joint light guide arm to complete the laser beam transmission.
The light guide arm is the role of the laser transmission to patients to operation
site (target).
2. scanner
Graphics scanner can scan output, rectangular, round, hexagonal, triangular and
other graphics, the largest area of about 20 * 20mm2 scanning;
3. Main unit
It includes a high voltage power supply, a low-voltage power supply, control
system, cooling system, laser system and blowing system.
4. touch display panel
Mainly used for parameter setting
[Link] switch
A key into the key switch, go to the "open" position, the instrument power on, go
to the "off” position to cut the power, turn off the instrument.
6. Wheels
2. Installation
1) Checking

1. Check the packing box before open, if no abnormal, you can open it. Becase the
machine is equipped with laser tube and precision optical system, forbid pound and
collision when open the box.
2. Take out the packing list after opening the box, then take out the host and spare parts
according to the packing list, check every spare parts, wire connections, confirmed no
abnormal or troubleshooting before installation, if have any problem, please contact
manufacturer timely, so that resolve the problem Quickly.

2) Fill distilled water

1. Press the stainless steel sheet at the above of the overflow hole, pull the water tube
into the hole.
2. Put the tube into the affusion hole, do like as above said, fill distilled water, it's ok when
the water overflow the overflow hole; after turn on the machine for 3 minutes, the
machine need fill water again.
Attention: you can't pull out the tube from the affusion hole when using the machine. You
need to change the water in every 60 days.
3) Installation of guide light arm

Guide light system was made up of guide light arm and connection seat .connection
seat has fixed into the top of the shell. After check the guide light arm, connect it to
connection seat, then fix the screws firmly.
Attention: guide light arm only can move to the arrow direction.

Move B 180 degree according to C, then press A according to the Arrow. Then insert B
to the hole on main unit, then screw D, fix the guide light arm firmly.
4) Installation of the scan head
1. Whirl the scan head to clockwise direction.

2. Installation of control wire on the scan head, insert the control wire, then fix the screws
firmly.

5) Installation of power cord and foot switch


1. Insert the power cord to the connector on the back of the machine, then check if firmly.
2. Connect the foot switch, aim at the gap, whirl to the clockwise direction, check if firmly.
6) change water
Put “add water” and ”run off water” connect, ventage plug connect run off water, then add
water again.

3. Direction for use and Operating procedure


1) Turn on the power of device
2) Appear to be the main screen as below when key switch is ON.

3) Select a mode and range of adjustment when the main screen comes up.
4) Operate it by stepping FOOT SWITCH after completing every procedure.
5) Detail instructions of each mode are as follows

4. Instruction

4.1 face treatment

Press this button, enter the treatment interface, you can adjust every parameter.
1) Touch “LASER POWER “ box, then press” ” or “ ” ,the energy will increase or
decrease.
* Range of Adjustment: 1-30W.

2) Touch “ RESIDENCE” box, press “ ” or “ ” to adjust.


* Range of Adjustment: 0.1-10.0ms

3) Touch “POINTS” box, press “ ” or” ” to adjust.


* Range of Adjustment: 1-5000ms

4) Touch “ROW SPACING” box, press” ” or “ ” to adjust.


* Range of Adjustment: 0.1mm ~ 2.6mm

5)Touch “SCAN MODE” box, press “ ” or “ ” to adjust.


* Range of Adjustment: Midsplit, Sequence,Disorder.

6)Touch “SCAN TIMES” box, press “ ” or “ ” to adjust.


* Range of Adjustment: 1-5th.

7)Touch ,you can change different shape,like Square, round,


triangular, hexagonal, straight.

8) Touch “ “ or “ “,you can change the shape size , And preview if the size
and shape is suitable when press “preview”.

9) After adjust suitable parameters, press “ ”,then press the foot


switch,the machine will shoot laser beam, turn to Main screen when touch “BACK”
box at the top right corner of screen.
4.2 Instruction of 3D mode
The treatment screen of PULSE MODE appears when selecting 3D box at the Main
Screen.

1) Touch “POWER “ box, then press” ” or “ ” ,the energy will increase or decrease.
* Range of Adjustment: 1-30W.

2) Touch “ MODE” box, press” ” or “ ”, adjust impulse, continue, single etc.


* Range of Adjustment:

3) Touch “POINT STAY” box, press” ” or “ ” to adjust.


* Range of Adjustment: 1-5000ms

4) Touch “PULSE WIDTH” box, press” ” or “ ”to adjust.


* Range of Adjustment: 1-10ms.

5)Touch “INTERVAL” box, press” ” or “ ” to adjust.


* Range of Adjustment: 1-10ms.

4.3 Instruction of 4D mode


1) Touch “LASER POWER “ box, then press” ” or “ ” ,the energy will increase or
decrease.
* Range of Adjustment: 1-30W.

2) Touch “ RESIDENCE” box, press “ ” or “ ” to adjust.


* Range of Adjustment: 0.1-10.0ms

3) Touch “POINTS” box, press “ ” or” ” to adjust.


* Range of Adjustment: 1-5000ms

4) Touch “ROW SPACING” box, press” ” or “ ” to adjust.


* Range of Adjustment: 0.1mm ~ 2.6mm

5)Touch “SCAN MODE” box, press “ ” or “ ” to adjust.


* Range of Adjustment: Midsplit, Sequence,Disorder.

6)Touch “SCAN TIMES” box, press “ ” or “ ” to adjust.


* Range of Adjustment: 1-5th.

7)Touch ,you can change different shape,like Square, round.

8) Touch “ “ or “ “,you can change the shape size , And preview if the size
and shape is suitable when press “preview”.

9) After adjust suitable parameters, press “ ”,then press the foot


switch,the machine will shoot laser beam, turn to Main screen when touch “BACK”
box at the top right corner of screen.

6. Instruction of private mode


1) Touch “LASER POWER “ box, then press” ” or “ ” ,the energy will increase or
decrease.
* Range of Adjustment: 1-30W.

2) Touch “ RESIDENCE” box, press “ ” or “ ” to adjust.


* Range of Adjustment: 0.1-10.0ms

3) Touch “POINTS” box, press “ ” or” ” to adjust.


* Range of Adjustment: 1-5000ms

4) Touch “ROW SPACING” box, press” ” or “ ” to adjust.


* Range of Adjustment: 0.1mm ~ 2.6mm

5)Touch “SCAN MODE” box, press “ ” or “ ” to adjust.


* Range of Adjustment: Midsplit, Sequence,Disorder.

6)Touch “SCAN TIMES” box, press “ ” or “ ” to adjust.


* Range of Adjustment: 1-5th.

7)Touch ,you can change different shape,like Square, round,


triangular, hexagonal, straight.

8) Touch “ “ or “ “,you can change the shape size , And preview if the size
and shape is suitable when press “preview”.
9) After adjust suitable parameters, press “ ”,then press the foot
switch,the machine will shoot laser beam, turn to Main screen when touch “BACK”
box at the top right corner of screen.

Chapter 5 Operation
1. Preparation:
Alcohol, cotton ball, sterile treatment head.

2. Operation:
3. Treatment:
3.1 Face treatment

These parameters are for the face, adjust the shape to square, and
biggest(20*20mm), then adjust same parameters, press GET READY, stating
the treatment. You can increase or decrease the POWER according to the
customer’s skin.

3.2 stretch mark treatment:

These parameters are for stretch mark. You can increase or decrease the
POWER according to the customer’s skin.

3.3 vagina treatment:


Insert the support to the vagina, then insert the 360 degree
head to the bottom of the support, pay attention to the number on
the 360 degree head, press the foot switch, then pull out 0.5cm,
press the foot switch again, then pull our 0.5cm again, press the
foot switch again, do again, after the 360 degree head reach vulva,
insert to the bottom of the support again, and do like the first time,
total 3 times.

3.4 vulva treatment:

Use the head for vulva, and make the distance 5cm, treat
vulva, press the foot switch for many times, until vulva tighten up.

3. Postoperative care and Notes:


1). Pay attention to the genital health after surgery.
2). More attention to rest.
3). Prohibitive life within a week.