Heat Recovery Steam Generators for
large combined cycle plants (250 MWe
GT output): experiences with different
design options and promising
improvements by once-through
technology development
1
1. ABSTRACT
Ansaldo Caldaie has gained extensive experience in designing, manufacturing and installing
HRSGs for gas turbine sizes ranging from 40 MWe to 250 MWe. The purpose of this paper is
to focus on large size HRSG units suitable for Siemens GT V94.3A or GE 9FA with 250 MWe
output. These HRSG units are designed under our proprietary technology based on two design
options: horizontal gas flow with natural circulation and vertical gas flow with assisted
circulation. Most of the units have been successfully tested and entered into commercial
operation during the last five years. The most relevant projects of these types of units are herein
presented and described along with their distinguishing features; specifically, the vertical
HRSG design suitable for insertion into the existing steel structure of old fired boilers in
repowered power stations is described. A comparison between the horizontal and vertical
design options is provided on the basis of functional, constructive and operating data collected
from a combined cycle power plant where two units with the same operating characteristics
and output, but with different configuration (horizontal and vertical), have been delivered.
Following a market trend towards extensive cycling operation and combined cycles of
increasing size with gas turbines of improved technology having higher exhaust gas
temperatures and flowrates, a new design option has become interesting in the recent years and
has been taken into account as a possible advancement for the HRSG technology: oncethrough
mode in the high pressure levels of the unit. For this design option, we, - as Siemens licensee
for Benson Once Through HRSG technology – have developed our own standard project. This
paper describes the main features of this project and highlights the most relevant advantages
that HRSG units based on this concept offer compared to Drum Type units.
2. INTRODUCTION
The current trend in the power generation industry is of rising demand for combined cycles
with improved efficiency and reduced delivery time. Improved efficiency reduces the fuel
related cost and, at the same time, contributes to the resolution of the greenhouse effect. Heat
Recovery Steam Generators are key components in the combined cycle. Starting from the early
90’s, we began developing our proprietary HRSG design for:
- Horizontal gas path, natural circulation, cold casing and top supported HRSG.
- Vertical gas path and assisted circulation HRSG.
2
A standard design has been developed in order to meet the main requirements of modern
combined cycles: short delivery time, high quality standards, fast site construction, proven
performance, elevated operating flexibility and easy maintenance and repair.
In the last decade, the majority of horizontal and vertical HRSGs, has been mainly based on
unfired triple pressure with reheater cycles downstream 250 MWe gas turbines. Also
supplementary fired HRSGs with one or two post firing (up to 280 MWth) have been designed.
Most of the units have been successfully tested and entered into commercial operation during
the last five years.
In order to meet recent market requirements in terms of extensive cycling operation and fast
start-up and to be ready for the next generation of high efficiency combined cycles based on
high pressure and temperature steam requirements, we, as others did, acquired HRSG Benson
Once Through technology from Siemens in 2003.
3. HORIZONTAL HRSG VS VERTICAL HRSG COMPARISON
4.1 Introduction
An intense HRSG re-powering of the old fired power stations units is currently underway in
Italy starting from the second half of the last decade. Two different options are available:
complete demolition of the existing boiler or insertion of the HRSG in the existing steel
structure, like Ostiglia Power Station. This plant consists of three triple pressure levels with
reheater HRSG's dowstream of a 250 MWe GE PG9351. Two are installed inside the existing
steel structure of old 320 MWe Utility Boilers supplied by us in the Sixties. Because of stack
height requirements for emission control, it was mandatory to install the third unit in horizontal
configuration by applying a stack height of 150 m, higher than the maximum height sustainable
from the existing structure. This uncommon plant configuration provides for a direct
comparison of both vertical and horizontal HRSG having the same boundary conditions in
terms of required HRSG design and performance.
4.2 Main HRSG characteristics comparison
Below Fig 1 shows the comparison of the two HRSG installed at the Ostiglia Power Station.
3
Fig. 1.1: Horizontal HRSG isometric view Fig. 1.2: Vertical HRSG isometric View
Common characteristics for both configurations are:
- Three pressure levels with reheater
- Intermediate desuperheating on high pressure superheater and reheater
- Integrated deareator on low pressure steam drum
- Drum level control valves downstream economisers to prevent steaming effect -
Serrated fin tubes in staggered arrangement.
- Standardised modular design to ease transportation and to reduce erection period at
site.
Main characteristics of horizontal HRSG design are:
- Top supported tube elements to allow free downward thermal expansion
- Cold casing design
- Natural circulation evaporators with small diameter tubes to reduce drum level
fluctuations.
Main characteristics of vertical HRSG design characteristics are:
- Top supported heating surfaces to the existing steel structure
- Cold casing (inner insulated) for the hot section and hot casing for the cold one -
4
Assisted circulation with 2x100% pumps for each pressure level.
From the geometrical point of view, Tab. 1
summarises the main vertical HRSG data Vert. vs.
differences compared to the horizontal ones. The Horiz.
difference in tube length is due to the geometrical
constraints of the existing steel structures. The Tube Length -9%
vertical HRSG has a higher
Max Parallel tubes Nr. +9%
Transversal tubes Nr. +5%
Total Tubes Nr. +14%
Surface -23%
number of tubes and, therefore, a smaller Tab. 1:
Main differences of Vertical HRSG heating surface than the horizontal one due to geometrical
data compared to the the geometrical constraints of vertical HRSG Horizontal HRSG ones
design.
4.3 Performance and operational comparison
Both HRSGs have been successfully tested and was found that the vertical one had a larger
over-performance in terms of power to the steam turbine. A detailed analysis of performance
test results indicated that this was due to:
- the peculiar HRSG design adopted for this critical project since Ostiglia was one of our
first application of vertical HRSG downstream large combined cycle plants
- a better overall performance of the vertical HRSG compared to the expected one; as an
example Fig. 2 shows low pressure evaporators pinch diagrams comparison for the two
configurations. It can be seen how multiple passage horizontal tube arrangement
ensures a more uniform heat transfer along the evaporator.
5
Fig. 2.1: Horizontal HRSG pinch diagram Fig.
LPEVA arrangement and 2.2: Vertical HRSG LPEVA
arrangement and
pinch diagram
Another positive outcome of the vertical arrangement is the hot gas buoyancy effect, in the
range of 8% credit of maximum guaranteed gas pressure loss value.
From the operational point of view the two plant configuration are equivalent even if vertical
HRSG could be difficult drainable but has an easier heating surface accessibility.
As far as auxiliary power consumption is concerned, total consumption of vertical HRSG is
about 4 times greater than the horizontal configuration, due to the three circulation pumps.
4.4 Weight comparison
Below Fig 3 shows the comparison of the total weight of the two different HRSG
configurations as a percentage of the total horizontal HRSG weight.
6
Fig. 3: HRSG Weight Comparison
Since Ostiglia vertical HRSG uses an existing steel structure, for the sake of comparison the
weight of vertical HRSG steel structure has been estimated as a “new structure”, to eliminate
any unwanted influence due to the re-utilization of the existing steel structure. A green field
vertical HRSG should be optimised with regard to lay-out and general arrangement in order
to minimise weights and costs. weight of vertical HRSG heat
It is possible to see how the vertical steel exchangers is reduced compared
structure performs a huge effect on total to the horizontal one, due to a
weights. This is partly due to vertical HRSG better evaporator performance
design characteristics and partly to the non of horizontal tube assisted
optimised lay-out imposed by the geometrical circulation evaporators.
constraints of the existing steel structure, as
shown on Fig. 4, where an example of Ostiglia
intricate piping arrangement is presented. The
7
Fig. 4: Vertical HRSG intricate piping arrangement
sample.
Since the high pressure evaporator is the main critical item in HRSGs, Fig. 5 below shows the
comparison of the weight of the two different HRSG HP evaporators as a percentage of the
total horizontal HRSG HP evaporator weight.
Fig. 5: High Pressure Evaporator Weight Comparison
4. NATURAL CIRCULATION HRSG VS BENSON ONCE THROUGH HRSG
COMPARISON
4.1 Introduction
As a matter of information, we have been Siemens Benson licensee for Utility Boiler for a
decade.
8
In order to meet recent market requirements in terms of:
- increased combined cycle performances (higher gas temperatures and higher steam
pressures and temperatures)
- extensive cycling operation (increasing number of cycles and fast start-up) we decided to
acquire Siemens HRSG Benson license in year 2003.
Such technology has been successfully proven at Cottam power plant in England, (to a
triplepressure HRSG downstream Siemens V94.3A gas turbine), as described in Modern Power
Systems, September 1999, pp.40-43 and Modern Power Systems, July 2000, pp 33-35.
We have recently undertaken an intense development activity with the purpose of best suiting
the constructive and functional characteristics of our horizontal HRSGs to the functional
requirements of Siemens Benson technology. At the end of last year such effort resulted in the
acquisition of the Multiple Purchase Agreement (MPA) with Siemens. According to this
agreement, the two companies intend to closely co-operate in the development, tendering,
processing, standardization and total cost reduction for the delivery of both Benson type and
drum type HRSGs for the next three years.
The main standard MPA HRSG characteristics are as follows:
GT: Siemens V94.3A4
HRSG design: Triple pressure with reheater. HP Benson Type (Drum type as an option) having
the following main steam parameters
Flow [kg/s] Pressure [bar] Temperature [°C]
HP Steam 77.3 129.9 566.5
RH Steam 91.1 30.7 565.1
LP Steam 10.6 4.4 234.6
Tab 2: Siemens Standard MPA SP3 main steam parameters
4.2 Main HRSG configuration comparison
At present the standard project of both Drum type and Benson type HRSG has reached
completion. In order to reduce the differences between the two projects, the design of both
HRSGs has been developed by applying a modification only to the HP evaporator module.
9
The main differences are:
- Drum in natural circulation HRSG and separator in Benson type one
- Different HP Evaporator internal and external piping
- Additional superheater in drum type HRSG design since Benson design steam temperature
at evaporator outlet is 75 °C superheated, as described in the following paragraph.
4.3 Once Through Evaporator Arrangement
Below Fig. 6 shows HP Evaporator flow diagram and HP Evaporator arrangement developed for
MPA Standard design.
Fig. 6: Benson type evaporator: Top view and flow diagram
11
The HP evaporator consists of two partial sections (EVA1 and EVA2), connected in series on
the exhaust gas side. Flow in each stage is in upward cross-flow arrangement. Wet steam flow
leaving EVA1 is collected through risers and downcomers to the star distributors placed on the
bottom of the evaporator, then it is distributed into the second evaporator stage EVA2. Flow at
EVA2 outlet is about 75 °C superheated in order to have a sufficient range for a main steam
temperature control by feedwater mass flow only during part loads and at varying ambient
conditions. A piping system collects the steam to the separator and then to high pressure
superheater. During start-up and at very low load condition flow at EVA2 outlet is wet steam
and the separator splits steam from water which can be recirculated from the water collecting
vessel to EVA1 through the start-up recirculation line.
Below Fig 7 shows the isometric view of MPA Benson type high pressure evaporator.
12
4.4 Thermal Performance comparison
Below Fig 8 shows drum type HP Evaporator main thermal performance data.
13
Fig. 8: Drum Type HP Evaporator Thermal Performance Diagram
Below Fig 9 shows Benson Type HP Evaporator main thermal performance data.
Fig. 9: Benson Type HP Evaporator Thermal Performance Diagram
EVA1 static head and friction loss bar chart shows how hydrostatic pressure drop decreases in
the hottest tubes due to the increased steam fraction. In order to maintain the same overall
pressure drop in all parallel circuits, steam water mixture flow increases in these tubes until
frictional loss and static head sum is equal in all circuits. This is the basis of Siemens Benson
technology, which ensures higher mass flow in the hottest tubes and lower mass flow in the
coldest one and as a result steam quality at tube outlet is quite uniform along all parallel tubes.
No individual orifice in the single tubes or tube rows is necessary.
Below Fig 10 shows high pressure evaporators pinch diagrams for both configurations.
SUPERHEATED STEAM
14
Fig. 10.1: Drum Type HRSG Fig. 10.2: Benson Type HRSG HPEVA arrangement
HPEVA arrangement ad pinch diagram and pinch diagram
4.5 Cycling behaviour comparison
The most interesting feature of Benson Once Through technology is surely the possibility to
operate HRSG with elevated start-ups and the shutdowns gradients, which means fast start-up
and short load variation time. This is due to the absence of high pressure drum that, because of
the elevated wall thickness, strongly limits temperature gradients. The stresses induced by
temperature gradients during start-up and shutdown cycles are in fact responsible of thick
components fatigue life consumption.
A fatigue analysis has been carried out in order to optimise start-up time in consideration of the
overall plant life consumption. To simplify the comparison only start-up and shutdown cycles
15
has been taken into consideration without take into account load variations and abnormal cases
like gas turbine trip.
The fatigue analysis and start-up optimisation has been carried out for three cases
- Drum type normal: typical start-up for drum type HRSG
- Drum type fast: drum type HRSG temperature gradient has been optimised during startup
in order to control fatigue life consumption.
- Benson type.
Fig. 11 shows the number of cycles taken into consideration, Fig. 12 shows the fatigue life
consumption due to these cycles. Comparison of these figures shows how Benson type HRSG
life consumption has been reduced up to more than 60% compared to drum type HRSG
allowing higher number of cycles than those considered.
Number of cycles 50
1250
5000
Cold Start-up Warm Start-up Hot Start-up
Fig. 11: Number of cycles considered
Life Consumption (*)
30%
Cold Start-up
Warm Start-up
25%
Hot Start-up
20%
15%
10%
5%
0%
Drum Type HRSG Benson Type HRSG
HP Drum HP Separator (*) According to EN 12952-3
Fig. 12: Fatigue life consumption
16
Start-up curves of the above cases are presented in Fig. 13 (time for steam turbine warming has
not been taken into consideration).
Fig. 13: Cold start-up curves comparison
It can be seen how the total start-up time has been reduced up to about 20% for drum type fast,
and about 60% for Benson type.
4.6 Weight comparison
Below Fig 14 shows the comparison of drum type HP evaporator weights versus the Benson type
one. This comparison is based on our standard design applied to Benson technology; other
HRSG suppliers design could lead to different figures. It should be also pointed out that new
Benson technology has not already been optimised as well known and consolidate drum type
technology.
Main differences are:
- Absence of steam drum in Benson type HP evaporator system
- In Benson type, higher evaporator connecting piping weight due to the more complex
internal piping.
- In Benson type, higher fin weight. Since mass flow in evaporators tubes is equal to steam
production, our HP evaporator has been designed with the minimum number of parallel
17
tubes in order to obtain the maximum flow. This involves the installation of maximum fin
surface obtainable on a given number of tube rows.
Fig. 14: High Pressure Evaporator Weight Comparison
5. CONCLUSION
An attempt to compare the Horizontal and Vertical HRSG designs has been carried out on the
base of our experience. The vertical HRSG design presents some attractive advantages mainly
connected with the possibility of inserting a HRSG in an existing utility boiler steel structure
for re-powering. However, in case of green field applications, the overall weight of the vertical
HRSG design remains well above the weight of the horizontal HRSG due to steel structure.
Natural circulation and Benson Once Through circulation have been compared on the base of
the design activities up to now performed in the frame of the Siemens Benson technology. We
have developed our own project for the OT HRSG and have dedicated special efforts to this
design to meet important supply requests. The outcome of our Project confirms the features
that are at the base of this technology allowing reduction of weights and optimum cycling
performance.
18