inhemeter Old
issue hexing version Inhemeter New version clou
balance inquiry 801 003 C501 07
Total units consumed
to date 800 002 5052 01
meter number 804 000 4200 65
maximum demand 810 009 160 02
cancel alarm 812 017 12
tarrif index 809 078 C7210 36
meter status 807 14 C51
Instantaneous power 808 006 ( 106) 170 31
relay off reason 806 95
token entered times 59 C150
commissioning 865 [enter] 1275 4194 1448
code( to close relay) 865[enter] 6450 5970 1275 4194 1448 6450 5970 auto
just pair with
decommisioning code 18075773902
5969 8686 0000 0000 0000
5969 8686 0000 0000 0000 next meter #
pairing meter to CIU Meter # 59698686+ meter number59698686+ meter number 1593570***
Display temper state
Supply Group Code 805 079 C605 70
Power Limit Level 810 015 21350 13
Power Fail Count 065 C70 52
Last date of topup 815 CL401 11( last time)
830,831...839(
Last Credit Voucher to the 10th last 80,79...76( to the
ID token) CL401 5th last tocken)
last units quantity 49, 50...58(identity, 85, 84..81( to 5th
topped up 817 time, date, units) CL401 tocken juiced)
Load Trip Test
004 (100, 101, 102
Voltage for 3 phase) 3270 86,87,88
005 ( 103, 104, 105
Current for 3 phase) 3170 89,90,91
Tocken Entered Times 048 C150
Alarm Threshold 066 C5112 12
Cover Open Times 064 C154 40
45,44,43,42,41( a
Time for last cover s u check the nth
opening CL 63n opening time)
last 24 hrs 082, 083..088( for
consumption 813 7days) E8201 08
Current 24 hrs
consumption 800 081 E820 08
820,821...825) 19, 20...30 ) this
this increase increases for
Previous 30 day for subsequent 024, 025...029 for subsequent
consumption month 6th month 1591 month
Current 30 day
consumption 814 001 1590 18
Last Time for
Recharging 816 CL401 11
last time of power cut 066 CL61n 57
Overvoltage
detections
Undervoltage
deections
times for overload
trip C530 46
59 - 63( for nth
time when a
time for phase off phase went off)
Code of meter wch
CIU is linked to 75
code for wrong data
entry reject reject 1 reject error 6
47,48...51(for the
nth overload
time for overload trip trip)
load switch opens
when
cummulative energy
juiced C5061 06
overload off times 090 C530 046
test all functions
reverse energy
detections
CLOU
Hexing
00 CREDIT 01
04,05,06,07,OD,OC TAMPER OB
Itron relay disconnect reason
No credit 1
Over power 2
Tamper 9
Memory failure 10
Over voltage 12
Undervoltage 13
Load Switch failure 22
Errors
20, 21 comms error
92, 99 CIU error
OOOOO Old tocken
UUUUU Used Tocken
XXXXX Key Expired
Overflow , Re-enter later after
EEEEE04 switching off
COMMON
PROMBLEMS
INHEMETER NEW
VERSION
landis sts Itron Iskra EDMI
002 009 9 3
003/61 004 248
100/9004(
when not
conected to
0 meter) 91
14
58 006 6 5
31
0000000000
44 2920
001 8064 050 50 9
031 250 8 6
auto auto Auto
long press i,
456 then 017777777(
0000000000 recomende
0 d easy) 755204
0000000000 enter meter
0*(meter #) # 0meter #0meter# meter #
0000000000
2281728512
60 030 30 92
0000000000
014 4429208064 007 bit 14
50
054 200 11 to 30
280,
281...295(1
5th last
55 tocken) 200 11 to 30
200,202,
204..n+2,
(up to 15th
56 entry)
0000000000
0150997584 001 1 1
070
073
270
33 refer to code 6
007 080
006 079
009 081
008 080
53
256 refer to code 008
257
happy and
sad face,
whilst eeee 13, 14,
beeping 7 sad face plus error number n-no-no
tamper,
decomission
ing, power
lockout
31 to 50
000
255
112.07
0.0999999999999943
NO CREDIT
PRESS 865
TWICE
l and G meter state( status) register
Power limit
lockout(30
1xxx xxxx M)
reverse
x1xx xxxx energy
power trip
xxxx x1xx 30s
xxxx xx1x no credit
xxxx xxx1 tamper
REASON FOR LAST REALY DISCONNECTION
After input the OBIS code for checking the last time the meter Relay disconnceted , The LCD in the CIU
will show in sequence as follows
1. Disconncetion time and date
2. Reconnection time and date
3. Disconncetion Meter state 1
[Link] Meter state 2
[Link] Meter state 3
Disconnection Meter Sate 1:
S/N Running Status code defination Remarks
0 No balance credit (balance is 0) 0: Not this reason
1: Yes
1 Warning status 0: NO
1: Yes
2 over powerlimit 0:No
1:Yes
3 Over Current 0:No
1:Yes
4 Unactivated meter 0:No
1:Yes
5 Remote control 1:Yes
0:No
6 Meter self checking fault 1:Yes
0:No
Rerserve
Reserved
7 d
Disconnection Meter Sate 2:
S/N Running Status code defination Remarks
0 over voltage 0: NO
1: Yes
1 Low voltage 0: NO
1: Yes
2 Reserve 0: NO
1: Yes
3 Terminal cover opened 0: NO
1: Yes
4 Reserved 0: NO
1: Yes
5 By-Pass 0: NO
1: Yes
6 Reserved Reserved
7 Reserved Reserved
Disconnection Meter Sate 3:
S/N Running Status code defination Remarks
0 Over temperature 0: NO
1: Yes
1 Magnet Detection 0: NO
1: Yes
2 Reserved Reserved
3 Reserved Reserved
4 Reserved Reserved
5 Reserved Reserved
6 Reserved Reserved
7 Reserved Reserved
he LCD in the CIU
issue hexing inhemeter clou landis sts Itron
balance inquiry 801 003 07 002 009
Total units consumed to
date 800 002 01 003/61 004
100/9004(
when not
conected
meter number 804 000 65 0 to meter)
maximum demand 810 009 02 14
cancel alarm 812 017 12
tarrif index 809 078 36 58 006
meter status 807 14 31
0000000000
44 2920
Instantaneous power 808 006 ( 106) 31 001 8064 050
relay off reason 806 95 031
token entered times 59
0000000000
Display temper state 2281728512
Supply Group Code 805 079 70 60 030
0000000000
Power Limit Level 810 015 13 014 4429208064 007
Power Fail Count 065 52 50
Last date of topup 815 11( last time) 054
280,
830,831...839( 80,79...76( to 281...295(
to the 10th last the 5th last 15th last
Last Credit Voucher ID token) tocken) 55 tocken)
200,202,
49, 204..n+2,
50...58(iden 85, 84..81( to (up to
last units quantity topped tity, time, 5th tocken 15th
up 817 date, units) juiced) 56 entry)
004 (100,
101, 102 for
Voltage 3 phase) 86,87,88 070
005 ( 103,
104, 105 for
Current 3 phase) 89,90,91 073
Tocken Entered Times 048 270
Alarm Threshold 066 12
Cover Open Times 064 40
45,44,43,42,4
1( as u check
Time for last cover the nth
opening opening time)
082,
previous 24 hrs 083..088( fo
consumption 813 r 7days) 08 007
Current 24 hrs
consumption 800 081 08 006
19, 20...30 )
820,821...825) 024, this increases
this increase 025...029 for
Previous 30 day for subsequent for 6th subsequent
consumption month month month 009
Current 30 day
consumption 814 001 18 008
Last Time for Recharging 816 11 53
last time of power cut 066 57
Overvoltage detections 256
Undervoltage deections 257
times for overload trip 46
59 - 63( for
nth time
when a phase
time for phase off went off)
Code of meter wch CIU is
linked to 75
code for wrong data entry reject error 6 eeee 13
47,48...51(for
the nth
time for overload trip overload trip)
tamper,
decomissioning
load switch opens when , power lockout
cummulative energy
juiced 06
overload off times 090 046
test all functions 000
reverse energy detections 255