OIL & GAS
MODEL 170/270/370 QX
HIGH-PRESSURE HIGH TEMPERATURE (HPHT)
WECO® UNION PRESSURE TRANSMITTER
SHOWN w/ 1/2" NPT(M) CONDUIT,
OTHER OPTIONS AVAILABLE
STANDARD WIRING #10-32 EXTERNAL
GROUND SCREW
MODEL MODEL MODEL
WIRE
170QX 270QX 370QX
A/1/RED +EXC +EXC +EXC/SIG
B/2/BLK -EXC -EXC -EXC/SIG 316 SST HOUSING
C/3/BLU +SIG +SIG +SHUNT (ALT) WITH 90 COOLING FINS
D/4/WHT -SIG -SIG N/C
E/5/ORG +SHUNT (OPT) +SHUNT (OPT) +SHUNT (OPT)
6.75
F/6/BRN -SHUNT (OPT) -SHUNT (OPT) -SHUNT (OPT) [171.45]
G/7/GRN CASE GND CASE GND CASE GND
Ø3.25 [82.55]
1.75
[44.45]
Ø2.67 [67.79]
Ø3.69 [93.68]
Inches (mm)
Standard configurations shown.
Please consult factory for other options.
PRODUCT OVERVIEW: FEATURES:
GP:50’s Model 370-QX series is designed for High • 2”-1502, 2002 and 2202 WECO® Union
Pressure High Temperature (HPHT) well applications. compatible
This series is designed to fit the standard WECO® • Process temperature rated to +350 °F (+177 °C)
2”- 1502 or 2”- 2002/2202 unions and operates at • 0 to 5K thru 0 to 20K PSI (345 thru 1,379 BAR)
a continuous process temperature to +350 °F (+177 • Corrosion resistant materials
°C). It offers reliable service in high shock and vibration • Optional improved accuracy specifications
applications such as cementing, fracturing and drilling • Hazardous area location approvals
mud pressure measurement.
APPLICATIONS: OPTIONS:
• High-pressure, high-temperature (HPHT) wells • FM, CSA ATEX, IEC*
• Choke and kill manifolds • WECO® 2” 1502 or 2” 2002 wing union fitting
• Blowout preventer (BOP) • Stainless steel or Inconel X750/ X718 construction
• Hydraulic fracturing • Shunt calibration signal
• 3 mV/V, 0 to 5 Vdc, 4-20 mA or CANbus output
• Comprehensive list of electrical connections
including shipboard rated cable
*For details on available approvals go to:
https://www.gp50.com/certifications
© 2014 GP:50 NY Ltd. | 2770 Long Road, Grand Island, NY 14072 USA
A5SL-044
Tel: +1.716.773.9300 Fax: +1.716.773.5019 Email: [email protected] Web: www.gp50.com REV-A
GP:50 MODEL 170/270/370 QX
REFERENCE SPECIFICATIONS (Standard configurations shown, consult factory for other options)
ELECTRICAL MECHANICAL
(170) 3 mV/V Process Connection: WECO® 2” - 1502 or 2002/2202
(270) 0 to 5 Vdc
Output Signal: Electrical Connection: Bendix PTO2E-106P standard
(370) 4-20 mA
(570) CANbus / SAE J1939 Proof Pressure: 1.5X FSO
(170) 15 Vdc max Burst Pressure: 3.0X FSO
(270) 9 to 36 Vdc
Excitation Voltage:
(370) 9 to 36 Vdc Ingress Protection IP67 (some options may affect rating)
(10 to 28 Vdc for GI/AI/I approvals)
Approximate Weight: 6 lb (2.72k)
Model 170 >100K Ω
Load Resistance:
Model 270 >10K Ω
Input Current:
(Model 170) 1 mA PRESSURE RANGES
(Model 270) 8 mA
0 to 5000 PSI thru 0 to 20K PSI (69 thru 1,379 BAR)
Circuit Protection: RFI, EMI and reverse polarity
(Model 170/270) 100% FSO by shorting 2
Shunt Calibration:
pins, non-isolated versions
THERMAL SPECIFICATIONS
Operating Range: -50 °F to +360 °F (-45 °C to +182 °C)
MATERIALS OF CONSTRUCTION Compensated Range: -40 °F to +350 °F (-40 °C to +177 °C)
Standard: 17-4 PH (H1025) SST for ≤10K PSI Storage Ambient: -60 °F to 190 °F (-51 °C to +87 °C)
Sensor: Wetted and Inconel 718 NACE for ≥ 15K PSI
Material Selectable
Optional Inconel X750 or 718 Effect on Zero/Span: ±2.0% FSO/100 °F
GAS
Housing: 300 Series Stainless Steel Improved or expanded temperature compensation available
ACCURACY (RSS): Hysteresis, Non-Linearity & Repeatability @ +70 °F) APPROVALS (370 SERIES ONLY)
Standard: ≤±0.25% FSO FM/CSA/ATEX/IEC Intrinsic Safety
&
Zero & Span Balance: <±1.0% FSO/100 °F FM/CSA/ATEX/IEC Zone 2
CE Marked
OIL
All specifications are for reference purposes only. In the interests of
© 2014 GP:50 NY Ltd. | 2770 Long Rd, Grand Island, NY 14072 USA continuous product improvement, all specifications are subject to change
Tel: +1.716.773.9300 Email:
[email protected] Web: www.gp50.com without notice. Please contact GP:50 for assistance with your application.